首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Retention and separation of achiral compounds in supercritical fluid chromatography (SFC) depend on numerous parameters: some of these parameters are identical to those encountered in HPLC, such as the mobile phase polarity, while others are specific to SFC, as the density changes of the fluid, due to temperature and/or pressure variations. Additional effects are also related to the fluid compressibility, leading to unusual retention changes in SFC, for instance when flow rate or column length is varied. These additional effects can be minimised by working at lower temperatures in the subcritical domain, simplifying the understanding of retention behaviours. In these subcritical conditions, varied modifiers can be mixed to carbon dioxide, from hexane to methanol, allowing tuning the mobile phase polarity. With nonpolar modifiers, polar stationary phases are classically used. These chromatographic conditions are close to the ones of normal-phase LC. The addition of polar modifiers such as methanol or ACN increases the mobile phase polarity, allowing working with less polar stationary phases. In this case, despite the absence of water, retention behaviours generally follow the rules of RP LC. Moreover, because identical mobile phases can be used with all stationary phase types, from polar silica to nonpolar C18-bonded silica, the classical domains, RP and normal-phase, are easily brought together in SFC. A unified classification method based on the solvation parameter model is proposed to compare the stationary phase properties used with the same subcritical mobile phase.  相似文献   

2.
Whereas the retention rules of achiral compounds are well defined in high-performance liquid chromatography, on the basis of the nature of the stationary phase, some difficulties appear in super/subcritical fluid chromatography on packed columns. This is mainly due to the supposed effect of volatility on retention behaviours in supercritical fluid chromatography (SFC) and to the nature of carbon dioxide, which is not polar, thus SFC is classified as a normal-phase separation technique. Moreover, additional effects are not well known and described. They are mainly related to density changes of the mobile phase or to adsorption of fluid on the stationary phase causing a modification of its surface. It is admitted that pressure or temperature modifications induce variation in the eluotropic strength of the mobile phase, but effects of flow rate or column length on retention factor changes are more surprising. Nevertheless, the retention behaviour in SFC first depends on the stationary phase nature. Working with polar stationary phases induces normal-phase retention behaviour, whereas using non-polar bonded phases induces reversed-phase retention behaviour. These rules are verified for most carbon dioxide-based mobile phases in common use (CO(2)/MeOH, CO(2)/acetonitrile or CO(2)/EtOH). Moreover, the absence of water in the mobile phase favours the interactions between the compounds and the stationary phase, compared to what occurs in hydro-organic liquids. Other stationary phases such as aromatic phases and polymers display intermediate behaviours. In this paper, all these behaviours are discussed, mainly by using log k-log k plots, which allow a simple comparison of stationary phase properties. Some examples are presented to illustrate these retention properties.  相似文献   

3.
4.
In this third paper, varied types of polar stationary phases, namely silica gel (SI), cyano (CN)- and amino-propyl (NH2)-bonded silica, propanediol-bonded silica (DIOL), poly(ethylene glycol) (PEG) and poly(vinyl alcohol) (PVA), were investigated in subcritical fluid mobile phase. This study was performed to provide a greater knowledge of the properties of these phases in SFC, and to allow a more rapid and efficient choice of polar stationary phase in regard of the chemical nature of the solutes to be separated. The effect of the nature of the stationary phase on interactions between solute and stationary phases and between solute and carbon dioxide-modifier mobile phases was studied by the use of a linear solvation energy relationship (LSER), the solvation parameter model. The retention behaviour observed with sub/supercritical fluid with carbon dioxide-methanol is close to the one reported in normal-phase liquid chromatography with hexane. The hydrogen bond acidity and basicity, and the polarity/polarizability favour the solute retention when the molar volume of the solute reduces it. As with non-polar phases, the absence of water in the subcritical fluid allows the solute/stationary phase interactions to play a greater part in the retention behaviour. As expected, the DIOL phase and the bare silica display a similar behaviour towards acidic and basic solutes, when interactions with basic compounds are lower with the NH2 phase. On the CN phase, all interactions (hydrogen bonding, dipole-dipole and charge transfer) have a nearly equivalent weight on the retention. The polymeric phases, PEG and PVA, provide the most accurate models, possibly due to their better surface homogeneity.  相似文献   

5.
In order to obtain a selection of optimal chromatographic columns for the separation of chlorotriazine pesticides in packed column supercritical fluid chromatography (pSFC), a multi-criteria approach is applied. For this purpose, prediction of the separations is carried out, based on quantitative structure–retention relationships, then Derringer's desirability function is proposed to determine the stationary phase that will result in the most desirable separation. The best SFC separation obtained was then optimized using a mobile phase gradient. Besides, the accuracy of the solvation parameter model as SFC retention predictive model is assessed.  相似文献   

6.
To understand the chromatographic process as a whole, whether it be for gas chromatography (GC), liquid chromatography (LC), or supercritical fluid chromatography (SFC), one needs to know the chemical and physical nature of the mobile and stationary phases and also the interactions that take place between analytes (solutes) and the two phases. An approach towards Investigating the ways that stationary and mobile phases contribute to chromatographic retention Involves exploring the effects of solvent polarity on the strength of the mobile phase. In SFC this could involve determining the polarity of several different modifier/carbon dioxide mobile phases. In this paper, the use of a solvatochromic indicator to learn more about the effects of SFC modifier/mobile phase polarity will be investigated and discussed using several different modifiers and a diolmodified silica column.  相似文献   

7.
A relatively new stationary phase containing a polar group embedded in a hydrophobic backbone (i.e., ACE ® C18‐amide) was evaluated for use in supercritical fluid chromatography. The amide‐based column was compared with columns packed with bare silica, C18 silica, and a terminal‐amide silica phase. The system was held at supercritical pressure and temperature with a mobile phase composition of CO2 and methanol as cosolvent. The linear solvation energy relationship model was used to evaluate the behavior of these stationary phases, relating the retention factor of selected probes to specific chromatographic interactions. A five‐component test mixture, consisting of a group of drug‐like molecules was separated isocratically. The results show that the C18‐amide stationary phase provided a combination of interactions contributing to the retention of the probe compounds. The hydrophobic interactions are favorable; however, the electron donating ability of the embedded amide group shows a large positive interaction. Under the chromatographic conditions used, the C18‐amide column was able to provide baseline resolution of all the drug‐like probe compounds in a text mixture, while the other columns tested did not.  相似文献   

8.
Hydrophilic interaction chromatography (HILIC) is described as a useful alternative to reversed-phase chromatography for applications involving polar compounds. In the HILIC mode, an aqueous-organic mobile phase is used with a polar stationary phase to provide normal-phase retention behavior. Silica and amino columns with aqueous-acetonitrile mobile phases offer potential for use in the HILIC mode. An examination of the retention and separation of several pyrimidines, purines, and amides on silica and amino columns from three manufacturers revealed that mobile phases should contain a buffer or acid for pH control to achieve similar and reproducible results among columns from different sources. Amino columns may also be used in an anion-exchange mode, which provides an advantage for some applications. In some cases, silica can provide different selectivity and better separation than an amino column. Example applications include: low-molecular-mass organic acids and amides as impurities in non-polar drug substances, 5-fluorouracil in 5-fluorocytosine, guanine in acyclovir, and different selectivity for polar basic compounds compared to an ion-pairing system.  相似文献   

9.
Hydrophilic interaction chromatography (HILIC) is valuable alternative to reversed-phase liquid chromatography separations of polar, weakly acidic or basic samples. In principle, this separation mode can be characterized as normal-phase chromatography on polar columns in aqueous-organic mobile phases rich in organic solvents (usually acetonitrile). Highly organic HILIC mobile phases usually enhance ionization in the electrospray ion source of a mass spectrometer, in comparison to mobile phases with higher concentrations of water generally used in reversed-phase (RP) LC separations of polar or ionic compounds, which is another reason for increasing popularity of this technique. Various columns can be used in the HILIC mode for separations of peptides, proteins, oligosaccharides, drugs, metabolites and various natural compounds: bare silica gel, silica-based amino-, amido-, cyano-, carbamate-, diol-, polyol-, zwitterionic sulfobetaine, or poly(2-sulphoethyl aspartamide) and other polar stationary phases chemically bonded on silica gel support, but also ion exchangers or zwitterionic materials showing combined HILIC-ion interaction retention mechanism. Some stationary phases are designed to enhance the mixed-mode retention character. Many polar columns show some contributions of reversed phase (hydrophobic) separation mechanism, depending on the composition of the mobile phase, which can be tuned to suit specific separation problems. Because the separation selectivity in the HILIC mode is complementary to that in reversed-phase and other modes, combinations of the HILIC, RP and other systems are attractive for two-dimensional applications. This review deals with recent advances in the development of HILIC phase separation systems with special attention to the properties of stationary phases. The effects of the mobile phase, of sample structure and of temperature on separation are addressed, too.  相似文献   

10.
Adopting a stationary phase convention circumvents problematic definition of the boundary between the stationary and the mobile phase in the liquid chromatography, resulting in thermodynamically consistent and reproducible chromatographic data. Three stationary phase definition conventions provide different retention data, but equal selectivity: (i) the complete solid phase moiety; (ii) the solid porous part carrying the active interaction centers; (iii) the volume of the inner column pores. The selective uptake of water from the bulk aqueous‐organic mobile phase significantly affects the volume and the properties of polar stationary phases. Some polar stationary phases provide dual‐mode retention mechanism in aqueous‐organic mobile phases, reversed‐phase in the water‐rich range, and normal‐phase at high concentrations of the organic solvent in water. The linear solvation energy relationship model characterizes the structural contributions of the non‐selective and selective polar interactions both in the water‐rich and organic solvent‐rich mobile phases. The inner‐pore convention provides a single hold‐up volume value for the retention prediction on the dual‐mode columns over the full mobile phase range. Using the dual‐mode monolithic polymethacrylate zwitterionic micro‐columns alternatively in each mode in the first dimension of two‐dimensional liquid chromatography, in combination with a short reversed‐phase column in the second dimension, provides enhanced sample information.  相似文献   

11.
In a recent paper published by Mitchell et al. in this journal, some results obtained in supercritical fluid chromatography and interpreted with the solvation parameter model to characterize interactions for “novel stationary phases” were surprising to us. Indeed, we had already published results for most of the stationary phases reported, but, except for polar phases, our results were not in agreement with those, despite the use of identical mobile phases in both studies. These data were disturbing because they suggest that supercritical fluid chromatography is always a normal‐phase mode, while we have shown that it is a reversed‐phase mode when working with non‐polar stationary phases. In the process of establishing the reason for the differences between our works, we examined several different factors. This paper deals with practice of linear solvation energy relationships: choice of dead‐volume marker, choice of test‐solutes to adequately probe the possible interactions and appropriate column length for characterization of chromatographic systems with highly eluting mobile phases are discussed. The importance of control experiments to validate retention models and confirm their accordance with the chromatographer's experience is evidenced. Recommendations for good linear solvation energy relationship practice are suggested in order to avoid the publication of results leading to erroneous conclusions.  相似文献   

12.
Alkylphenol polyethoxylates (APEs) are a widely used group of nonionic surfactants in commercial production. Characterization of the composition of APE mixtures can be exploited for the determination of their most effective uses. In this study sample mixtures contain nonylphenol polyethoxylates and octylphenol polyethoxylates. The separation of individual alkylphenols by ethoxylate units is performed by supercritical fluid chromatography (SFC)-UV as well as normal-phase high-performance liquid chromatographic (HPLC)-UV employing packed columns. The stationary phase and column length are varied in the SFC setup to produce the most favorable separation conditions. Additionally, combinations of packed columns of different stationary phases are tested. The combination of a diol and a cyano column is found to produce optimal results. An advantage of using packed columns instead of capillary columns is the ability to inject large amounts of sample and thus collect eluted fractions. In this regard, fractions from SFC runs are collected and analyzed by flow injection analysis-electrospray ionization-mass spectroscopy in order to positively identify the composition of the fractions. In comparing the separation of APE mixtures by SFC and HPLC, it is found that SFC provides shorter retention times with similar resolution. In addition, less solvent waste is produced using SFC.  相似文献   

13.
In this paper, we present a combination of a key-solute test based on retention and separation factors of large probe solutes (carotenoid pigments) and a quantitative structure-retention relationship analysis based on the retention factors of small probe solutes (aromatic compounds), both performed in supercritical fluid chromatography, to investigate the different chromatographic behaviour of octadecylsiloxane-bonded stationary phases of all sorts: classical, protected against silanophilic interactions or not, containing polar groups (endcapping groups or embedded groups). The results indicate that the two approaches chosen (carotenoid test and solvation parameter model) are complementary and provide precise information on the chromatographic behaviour of ODS phases. The applicability of the classification to the selection of stationary phases is evidenced with some examples of separations.  相似文献   

14.
15.
This work aims to evaluate for the enantiomeric separations of three agrochemical toxins: haloxyfop-methyl, fenoxaprop-p-ethyl and indoxacarb on crystalline degradation products-chiral stationary phase (CDP-CSP) of high-performance liquid chromatography (HPLC) under normal and polar organic phases. In the normal phase, the mobile phase was n-hexane with alcohols including methanol and isopropanol as polar modifiers. In the polar organic phase mode, the mobile phase was methanol with different percentages of triethylammunium acetate. The influence of flow rate (0.3-0.9 mL/min), analyte concentration and silica gel particle sizes (10, 15 and 30 microm) was investigated. This new chiral stationary phase showed excellent stereoselectivity for the two enantiomers of haloxyfop-methyl and fenoxaprop-p-ethyl and chiral recognition for indoxacarb under normal-phase mode. However, under polar organic phase, only indoxacarb was separated (alpha < 1.5). The chromatographic results were compared with commercial chiral columns.  相似文献   

16.
Supercritical fluid chromatography was utilized in combination with the Abraham model of linear solvation energy relationship to characterize 11 different HPLC stationary phases. System constants were determined at one supercritical fluid chromatography condition for each stationary phase. The results indicate that several types of silica columns, including type B silica, type C silica, and fused core silica, are very similar in their retention behavior. Several aromatic stationary phases were characterized and it was found that, in contrast to the other phases studied, all of the aromatic stationary phases had positive contributions from the dispersion/cavity (v) term of the linear solvation energy relationship. Several aliphatic phases were characterized and there were several linear solvation energy relationship constants that differentiated the phases from each other, mainly the polar terms (dipolarity and hydrogen bonding). One stationary phase, a fused core pentafluorophenyl (PFP) phase, had very poor regression quality. The column volume of this phase was lower than the others in the study, which may have had some impact on the results of the regression.  相似文献   

17.
This paper describes a new test designed in subcritical fluid chromatography (SFC) to compare the commercial C18 stationary phase properties. This test provides, from a single analysis of carotenoid pigments, the absolute hydrophobicity, the silanol activity and the steric separation factor of the ODS stationary phases. Both the choice of the analytical conditions and the validation of the information obtained from the chromatographic measurements are detailed. Correlations of the carotenoid test results with results obtained from other tests (Tanaka, Engelhard, Sander and Wise) performed both in SFC and HPLC are discussed. Two separation factors, calculated from the retention of carotenoid pigments used as probe, allowed to draw a first classification diagram. Columns, which present identical chromatographic behaviors are located in the same area on this diagram. This location can be related to the stationary phase properties: endcapping treatments, bonding density, linkage functionality, specific area or silica pore diameter. From the first classification, eight groups of columns are distinguished. One group of polymer coated silica, three groups of polymeric octadecyl phases, depending on the pore size and the endcapping treatment, and four groups of monomeric stationary phases. An additional classification of the four monomeric groups allows the comparison of these stationary phases inside each group by using the total hydrophobicity. One hundred and twenty-nine columns were analysed by this simple and rapid test, which allows a comparison of columns with the aim of helping along their choice in HPLC.  相似文献   

18.
The purpose of the present work was to systematically study the chromatographic behaviour of different aromatic stationary phases in a subcritical fluid mobile phase. We attempted to assess the chemical origin of the differences in retention characteristics between the different columns. Various types of aromatic stationary phases, all commercially available, were investigated. The effect of the nature of the aromatic bonding on interactions between solute and stationary phases and between solute and carbon dioxide-methanol mobile phase was studied by the use of a linear solvation energy relationship (LSER): the solvation parameter model. This study was performed to provide a greater knowledge of the properties of these phases in subcritical fluid chromatography, and to allow a more rapid and efficient choice of aromatic stationary phase in regard of the chemical nature of the solutes to be separated. Charge transfer interactions naturally contribute to the retention on all these stationary phases but are completed by various other types of interactions, depending on the nature of the aromatic group. The solvation vectors were used to compare the different phase properties. In particular, the similarities in the chromatographic behaviour of porous graphitic carbon (PGC), polystyrene-divinylbenzene (PS-DVB) and aromatic-bonded silica stationary phases are evidenced.  相似文献   

19.
Chromatography with a supercritical fluid as the mobile phase was suggested more than four decades ago (Klesper, E., Corwin, A. H., Turner, D. A., J. Org. Chem. 1962, 27, 700-701). Supercritical fluid chromatography (SFC) is basically a hybrid of GC and LC that eases the resolution of a mixture of compounds not conveniently resolved by either GC or LC. The mobile phases for SFC have low viscosities and high diffusion coefficients compared to those for HPLC and allow for high efficiency separations. SFC uses supercritical fluid as the mobile phase, polar organic solvents as the modifiers in conjunction with acidic/basic compounds as additives to run the chromatographic process like in HPLC. In many applications, SFC-based methods are advantageous over HPLC-based methods as a separation tool in terms of efficiency and economical impact perspectives. Today, the availability of commercial hardware and API interfaces with a mass spectrometer makes SFC even more widely applicable for chemical analysis in many research fields. This review summarizes a variety of novel SFC-MS methods for chemical analysis that have been reported in the peer-reviewed publications.  相似文献   

20.
Abstract

The retention data for 16 benzodiazepines was evaluated on different normal-phase HPLC columns using the Soczewinski-Snyder model. The slopes and intercepts of the linear relationships between log k' and the mobile phase composition have been discussed in relation to solute and stationary phase characteristics. The good correlation between substituent chromatographic contribution and substituent electronic constant showed that the benzodiazepine molecule acts as a proton donor towards the adsorbent sites of the stationary phases investigated.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号