首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A sensitive and rapid liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS) method has been developed and validated for the determination of mizolastine in human plasma using dipyridamole as the internal standard (I.S.). Plasma samples were simply pretreated with methanol for deproteinization. Chromatographic separation was performed on an Agilent Zorbax C18 column with a mobile phase of 10 mM ammonium acetate buffer containing 0.1% formic acid–methanol (20:80, v/v) at a flow rate of 1 mL min−1. The electrospray ionization (ESI) interface was employed in a single quadrupole mass spectrometer. The analytes were protonated in the positive ESI interface and detected in single ion monitoring (SIM) mode. Chromatographic separation was achieved in less than 3.5 min. The linearity was established over the range of 0.5–600 ng mL−1. The lower limited of quantification (LLOQ) of the method was 0.5 ng mL−1. The intra- and inter-run standard deviations were both less than 11.2%. The method was applied to study the pharmacokinetics of the mizolastine sustained-release tablets in healthy volunteers.  相似文献   

2.
3.
A new type of capillary column for gas chromatography was proposed. A sorbent layer (for example, stationary liquid phase) is supported on the internal capillary surface, and the internal (interstitial) volume is packed with nonporous large particles of a sorbent (particle diameter is 0.1—0.6 of the capillary internal diameter). The external surface of the particles can also be coated with the sorbent layer (for example, stationary liquid phase). The specific separation efficiency (number of separation) on the new type column is by 1.6—2.3 times higher than that of the initial classical capillary column.  相似文献   

4.
Summary The criteria for the optimization of preparative chromatography are sample throughput and product purity. It is shown for column liquid chromatography that the throughput has been maximized for a given purity by column overloading and appropriate fractionation. The size and position of the fraction must be determined by chemical analysis, since overlapping peaks under overloading conditions are usually distorted compared to the peaks of the same amounts of pure compounds. With overloading of the column larger particles can be used as column packings without reduction of the separation effect.  相似文献   

5.
Poly(lauryl methacrylate-co-ethylene dimethacrylate) monoliths were in situ synthesized within the confines of a silicosteel tubing of 1.02 mm i.d. and 1/16" o.d. for microbore reversed-phase HPLC. In order to obtain practically useful monoliths with adequate column efficiency, low flow resistance, and good mechanical strength, some parameters such as total monomer concentration (%T), cross-linking degree (%C) and polymerization temperature were optimized. High-efficiency monoliths were successfully obtained by thermal polymerization of a monomer mixture (40%T, 10%C) with a binary porogenic solvent consisting of 1-propanol and 1,4-butandiol (7:4, v/v) at a high temperature of 90 °C. The morphology and porous structure of the resulting monoliths were assessed by scanning electron microscope (SEM) and inverse size exclusion chromatography (ISEC), while the column performance was evaluated through the separations of a series of alkylbenzenes in acetonitrile-water (50:50, v/v) eluent. At a normal flow rate of 50 μL/min (corresponding to 1.66 mm/s), the optimized monolithic columns typically exhibited theoretical plate numbers of 6000 plates/10 cm-long column for amylbenzene (k>40), and the pressure drop was always less than 1 MPa/10 cm. The monoliths, which were chemically anchored to the tube inner wall surface using a bifunctional silylation agent, exhibited adequate mechanical strength of up to 12-13 MPa, and were properly operated at 10 times higher flow rate than normal, reducing the separation time to one tenth. The lauryl methacrylate-based monolithic column was applied to a rapid and efficient separation of ten common proteins such as aprotinin, ribonuclease A, insulin, cytochrome c, trypsin, transferrin, conalbumin, myoglobin, β-amylase, and ovalbumin in the precipitation-redissolution mode. Using a linear CH(3)CN gradient elution at a flow rate of 500 μL/min (10-times higher flow rate), 10 proteins were baseline separated within 2 min.  相似文献   

6.
Solvent-assisted supercritical fluid extraction is superior to Soxhlet extraction, solvent extraction at reflux, and simultaneous setam distillation solvent extraction for the isolation of semivolatile compounds from the cinnamons of commerce. Optimized extraction conditions are described using carbon dioxide at 300 atm and 70°C to extract 0.5 g of powdered cinnamon mixed with 4.5 g of anhydrous sodium sulfate to which 1.0 ml of acetonitrile was added at the start of the sequential 30 min static and 30 min dynamic extraction. The semivolatile compounds were collected by solvent trapping in ethyl acetate and analyzed directly by series coupled-column gas chromatography after filtration and partial solvent evaporation. Twenty-one compounds identified by mass spectrometry were quantified in twenty-four samples of cinnamon and cassia purchased in Sri Lanka, Korea, United Kingdom, and the United States of America. True cinnamon is easily distinguished from cassia by the presence of eugenol, absence of δ-cadinene, much lower amounts of coumarin, and larger amounts of benzyl benzoate. Principal component analysis using the relative composition of the twelve major semivolatile compounds provides a clear distinction between true cinnamon and cassia as well as useful interspecies differences which can be used for further classification.  相似文献   

7.
A method has been developed for the isolation of strontium from human urine for subsequent determination in sample volumes as low as 5–20 mL. This method involves the acidification of the sample using methanesulfonic acid and its decolorization using charcoal, treatment of the filtrate with Diphonix® resin, and subsequent concentration of strontium on Sr resin. Data from retention model simulations provided the initial conditions which were then optimized by actual column separations. Diphonix® resin was shown to be effective at removing alkali metal ions from the urine matrix under conditions that retain higher valence ions. The suggested processing method provides 99% recovery of Sr2+, a concentration factor of 50, and an expected per sample processing time of less than 1 h.  相似文献   

8.
A method for the preparation of poly(N-vinylpyrrolidone-co-pentaerythritol triacrylate copolymerization)-based monolithic capillary column was reported for the separation of polar small molecular weight compounds with nano-liquid chromatography in hydrophilic interaction chromatography mode. The monolithic columns were prepared by in situ copolymerization of N-vinylpyrrolidone and a cross-linker pentaerythritol triacrylate in a binary porogenic agent consisting of methanol and water. The composition of the polymerization solution was systematically optimized in terms of column permeability, theoretical plate number, asymmetric factor, and retention factor. A typical hydrophilic chromatography retention mechanism was observed with a mobile phase composed of a high content of organic solvent. The preparation method is simple and robust, the precursor N-vinylpyrrolidone is chemically stable, cheap, and easily available. The N-vinylpyrrolidone-based hydrophilic interaction chromatography stationary phase displays satisfactory separation selectivity for a range of polar test analytes, including benzoic acid derivatives, nucleosides, and phenols.  相似文献   

9.
Summary The provitamin A content of some food samples was determined by methods involving MgO: Hyflosupercel gravityflow column chromatography (GFCC) and reversed phase high performance liquid chromatography (HPLC), the quantitation being done by external standardization (HPLC-ES) or internal standardization (HPLC-IS) with Sudan. The results obtained with - and -carotene in carrots, -carotene and -cryptoxanthin in papaya and -carotene in tomato and kale agreed well, showing that any of the these techniques can be used, provided the analysis is done under optimum conditions. Good separation of the different provitamins using GFCC depends on the analyst's skill and visual acuity. HPLC-ES required a constant supply of provitamin standards, thus the varying purity of commercially available standards and the high instability of these compounds could pose grave problems. Due to the stability of Sudan, HPLC-IS appeared to be the method of choice although passage of the extract through a MgO: Hyflosupercel minicolumn was required prior to injection to separate chlorophylls, dihydroxy- and polyoxycarotenoids which would otherwise elute with Sudan. Nonconformity of the Sudan structure to those of the provitamins did not effect the quantitative results. The chromatographic separation, identity and quantification of the provitamins could be more easily established by using HPLC-IS, complemented with GFCC.  相似文献   

10.
11.
This work reports a fast and simple liquid chromatographic method for the simultaneous determination of five banned fat-soluble synthetic colorants, namely Sudan I-IV and Para-Red, in spice samples. The analytes were successfully separated isocratically in less than 5 min on the new narrow bore monolithic column, FastGradient® Chromolith (50 mm × 2.0 mm i.d.) using a mobile phase of 0.1% (v/v) HCOOH/acetonitrile (35/65%, v/v) at a flow rate of 1.5 mL min−1. All colorants were detected at 506 nm. The main parameters (mobile phase composition, flow rate, injection volume) affecting the separation were studied. The proposed method was thoroughly validated in terms of linearity, LODs, precision and accuracy. The method was applied to the determination of the studied azo-dyes in various spices (paprika, chilli and mixed spice powders) after ultrasound-assisted extraction. Satisfactory recoveries, ranging from 92% to 109% were obtained.  相似文献   

12.
Yuwei Qiao  Bin Wang  Anping Deng 《Talanta》2009,80(1):98-5161
The preparation and characterization of an immunoaffinity chromatography (IAC) column for the specific extraction and enrichment of trace contraceptive drug levonorgestrel (LNG) from water samples were described. The IAC column was constructed by covalently coupling specific polyclonal antibody against LNG to CNBr-activated Sepharose 4B and packed into a common solid phase extraction (SPE) cartridge. The extraction conditions including loading, washing and eluting solutions, as well as the effect of flow rate on the extraction were carefully optimized. Pure water, 5% of methanol and 50% of methanol were respectively selected as loading, washing and eluting solutions, while the flow rates in the loading, washing and eluting steps were selected to be 1.0, 2.0 and 0.5 mL min−1, respectively. Under optimal conditions, the IAC column was characterized in terms of maximum capacity, extraction recovery and stability. It was found that, for IAC column packed with 0.2 g of solid support immobilized with antibody, the maximum capacity for LNG was about 260 ng. The extraction recoveries of the column for LNG at three different spiked concentrations were within 95.3-106.9%. After more than 35 times repeated usage, there was not significant loss of specific recognition. Using high performance liquid chromatography (HPLC) as an analytical tool, trace amount of LNG in the range of ng L−1 was found in river water and wastewater samples after 600-fold enrichment, demonstrated the feasibility of the prepared IAC column for LNG extraction.  相似文献   

13.
Cao X  Pei H  Huo L  Hu G  Ito Y 《Journal of separation science》2011,34(19):2611-2617
An improved type-J counter-current chromatography (CCC) planet centrifuge with two spiral tube columns (volume 2×15 mL, β value 0.3-0.7, tubing 0.8 mm id) was developed and evaluated for its retention ability of four typical different solvent systems including heptane-methanol (1:1, v/v) (A), hexane-ethyl acetate-methanol-water (1:1:1:1, v/v) (B), n-butanol-acetic acid-water (4:1:5, v/v) (C), PEG1000-K(2)HPO(4)-water (12.5:12.5:75, w/w) (D) under eight different operation modes. The results indicated that the spiral tube column could significantly increase the retention of four typical solvent systems compared with a traditional multilayer coil column with similar parameters (volume 35 mL, β value 0.3-0.7, tubing 0.8 mm id). The retention of stationary phase (S(f)) for the less polar system (A) and moderately polar solvent system (B) can be increased by about 10%, and for the polar system (C) and aqueous two-phase system (ATPS) (D) by 30-40%. The preliminary applications of this spiral tube column to the separation of small molecular compounds such as moderately polar theaflavins, polar anthocyanins and dipeptides were successful. Acceptable resolution can be obtained between cytochrome c and myoglobin, lysozyme and myoglobin when it was applied on protein separation; however, it still needs to be improved with regard to its column efficiency.  相似文献   

14.
A simple, easy and economical approach for the preparation of a hybrid carbon/silica monolithic capillary column was described for the first time by using silica monolith as framework in combination with hydrothermal carbonization at 180°C. During the preparation process, formamide was introduced to the reaction solutions to reduce the dissolution rate of monolithic silica skeleton and its optimal concentration was 1.5 M. Fourier transform infrared spectrometry, scanning electron microscopy, energy dispersive X‐ray spectrometry, and inverse size exclusion chromatography were carried out to characterize the as‐prepared column. The results demonstrated that carbon spheres ranging from 150 to 1000 nm were successfully attached to the surface of silica skeleton. The prepared hybrid carbon/silica column had a permeability of 4.4 × 10?14 m2. Chromatographic performance of the column was evaluated by separation of various compounds including alkylbenzenes, nucleosides and bases, and aromatic acids. The column exhibited an efficiency of 75 000 plates/m for butylbenzene at the optimal linear velocity of 0.23 mm/s. The successful separation of these compounds and the study on mechanism indicated that the column can be applied in mixed‐mode chromatography.  相似文献   

15.
An HETP equation for the capillary column is developed that takes into account the dependence of gaseous diffusion on pressure, the compressibility of the mobile phase, together with the unique relationship between mobile phase velocity, and the resistance to mass transfer in the stationary phase. The equation is used to develop a procedure for column optimization and expressions are derived that allow the optimum column radius and optimum column length to be calculated for a given fixed inlet pressure. It is shown that fast, simple separations are optimally achieved using relatively short small diameter columns. Conversely, optimum performance for the separation of complex mixtures requiring higher efficiencies requires the use of long columns with relatively large diameters.  相似文献   

16.
17.
A simple, safe, rapid and economical method was developed for the isolation of high-purity forskolin from Coleus forskohlii roots using activated charcoal as an adsorbent in a column. The elution was carried out under reduced pressure to make the process rapid. Activated charcoal acted as a reversed phase adsorbent and allowed elution of forskolin without much impurities. The residue, obtained from the eluate was purified and crystallized using different solvent mixtures to obtain pure forskolin. The forskolin isolated was analyzed and characterized by UV, IR, RP-HPLC, electrospray ionization MS, 1H NMR and 13C NMR. The yield was 0.097% w/w (RSD 5.6%). The purity was 96.9% w/w (RSD 0.3%) as determined by RP-HPLC. The present method enables researchers to produce high-purity forskolin in their labs by using common chemicals.  相似文献   

18.
Covadonga Alvarez 《Talanta》2009,79(2):280-283
A sensitive and specific and automated liquid chromatography-electrospray mass spectrometric (LC-ESI-MS) assay for the quantification of Cyclosporin A in human plasma was developed. Following a simple protein precipitation step, the supernatant was extracted on-line and directly injected into the system LC-ESI-MS. A relatively new type of monolithic column consisting of a silica rod with bimodal pore structure was used to achieve a retention time of 2.4 min with a very low backpressure at a flow rate of 1 ml/min. The assay was linear from 0.050 to 1.000 μg/ml. The mean recovery was 91%. The mean inter-day and intra-day precisions were 1.85% and 2.83%, respectively. The combination of the automated solid phase extraction and the low retention time achieved with this columns increase the throughput and decrease the time of analysis of each sample. This technology is useful in order to improve the efficiency of the bioanalytical studies.  相似文献   

19.
20.
A novel stationary phase triacontyl-functionalized monolithic silica capillary column was successfully prepared for reversed-phase capillary liquid chromatography. The performance of the monolithic silica capillary column coated with triacontyl chain for the separation of alkylbenzenes, xylene isomers, polycyclic aromatic hydrocarbons, and mixture of α- and β-carotenes was studied, which was compared to that using the monolithic silica capillary column coated with octadecyl chain. The comparison results showed that triacontyl-functionalized monolithic silica capillary column would be a promising media to be used for the separation of isomeric solutes with long chain in reversed-phase capillary liquid chromatography.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号