首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A new method for the simultaneous determination of five heavy metal ions, tin, nickel, lead, cadmium and mercury ions as metal‐tetra‐(2‐aminophenyl)‐porphyrin (T2APP) chelates was developed using reversed‐phase high performance liquid chromatography (RP‐HPLC) equipped with a photodiode array detector and combined with an on‐line enrichment technique. The tin, nickel, lead, cadmium and mercury ions were pre‐column derivatized with T2APP to form color chelates. The Sn‐T2APP, Ni‐T2APP, Hg‐T2APP, Cd‐T2‐APP and Pb‐T2APP chelates can be absorbed onto the front of the enrichment column when they are injected into the injector and sent to the enrichment column [Waters Xterra? RP18(5μ, 3.9 × 20 mm)] with a buffer solution of 0.05 mol/L pyrrolidine‐acetic acid (pH = 10.0) as mobile phase. After the enrichment had finished, by switching the six‐port switching valves, the retained chelates were back‐flushed by mobile phase and traveling towards the analytical column. These chelates separation on the analytical column [Waters Xterra? RP18 (5μ, 3.9 × 150 mm)] was satisfactory by gradient elution with methanol (containing 0.05 mol/L pyrrolidine‐acetic acid buffer salt, pH = 10.0) and acetone (containing 0.05 mol/L pyrrolidine‐acetic acid buffer salt, pH = 10.0) as mobile phase. The linearity range is 0.01?120 μg/L for each metal ion. The detection limits (S/N = 3) of tin, nickel, lead, cadmium and mercury are 4.0 ng/L, 3.5 ng/L, 2.5 ng/L, 3.0 ng/L and 3.0 ng/L, respectively. This method was applied to the determination of tin, nickel, lead, cadmium and mercury ions in tobacco and tobacco additives with good results.  相似文献   

2.
Hu Q  Yang G  Yin J  Yao Y 《Talanta》2002,57(4):751-756
This paper reports the utilization of tetra-(4-bromophenyl)-porphyrin (T(4)BPP) as a chelating reagent using Waters Xterratrade mark RP(18) column for the on-line column enrichment and the separation of trace lead, cadmium and mercury ions by reversed-phase high-performance liquid chromatography (RP-HPLC) with photodiode array detector. When the Hg-T(4)BPP, Pb-T(4)BPP and Cd-T(4)BPP chelates were injected into the injector and sent to the enrichment column with 0.05 mol l(-1) of pH 10.0 pyrrolidine-phosphoric acid buffer solution (containing 10% of tetrahydrofuran (THF)) as mobile phase. The chelates were retained on the top of the enrichment column. After the enrichment is finished, by switching the valve of six-ports switching valve, the retained metal-T(4)BPP chelates will be eluted by mobile phase in reverse direction and will travel towards analytical column. With THF (containing 0.05 mol l(-1), pH 10.0 pyrrolidine-phosphoric acid buffer salt) and 0.05 mol l(-1), pH 10.0 pyrrolidine-phosphoric acid buffer solution (containinging 10% THF) gradient elution as mobile phase, the chelates separation on the analytical column was satisfactory. The linearity ranges are 0.01-120 mug l(-1) for each metal ion. The detection limits (S/N=3) of lead, cadmium and mercury are 1.0, 0.5 and 1.0 ng l(-1), respectively. This method can be applied to the determination (mug l(-1)) level of lead, cadmium and mercury in drinking water with satisfactory results.  相似文献   

3.
A new method for the simultaneous determination of lead, cadmium, and mercury ions as metal tetra-(4-chlorophenyl)-porphyrin (T4CPP) chelates was developed using reversed-phase-high performance liquid chromatography (RP-HPLC) and combined with on-line enrichment technique. When the Hg-T4CPP, Pb-T4CPP, and Cd-T4CPP chelates were injected into the injector and sent to the enrichment column with 0.05 mol/L of pH = 10 pyrrolidine-acetic acid buffer solutions (containing 10% of THF) as mobile phase, they were absorbed onto the tip of the enrichment column. By switching the six ports switching valve, the retained chelates can be back-flushed by mobile phase and travel towards the analytical column. With 0.05 mol/L of pH = 10 pyrrolidine-acetic acid buffer solution (containing 10% of THF) and tetrahydrofuran (THF) (containing 0.05 mol/L pH = 10.0 pyrrolidine-acetic acid buffer salt) gradient elution as mobile phase, the separation of chelates on the analytical column was satisfactory. The linearity ranges are 0.01 ± 120 g/L for each metal chelate. The detection limits (S/N = 3) of lead, cadmium, and mercury are 2.0, 1.5, and 2.0 ng/L, respectively. This method was applied to the determination of the g/L level of lead, cadmium, and mercury ions in a water sample with good results.  相似文献   

4.
A new method for the simultaneous determination of tin, lead, cadmium, and mercury in tobacco and tobacco additive by reversed-phase high-performance liquid chromatography combined with microwave digestion and an online enrichment technique is developed. The tin, lead, cadmium, and mercury ions are precolumn derivatized with tetra-(4-dimethylaminophenyl)-porphyrin (T(4)-DMAPP) to form color chelates. The Sn-T(4)-DMAPP, Hg-T(4)-DMAPP, Cd-T(4)-DMAPP, and Pb-T(4)-DMAPP chelates are absorbed onto the front of the enrichment column using a buffer solution of 0.05 mol/L pyrrolidine-acetic acid (pH = 10.0) as the mobile phase. After the concentration is finished (by switching the six-port switching valve) the retained chelates are back-flushed by the mobile phase and move to the analytical column. The chelate separation on the analytical column is satisfactory using gradient elution with methanol (containing 0.05 mol/L pyrrolidine-acetic acid buffer salt, pH = 10.0) and tetrahydrofuran (containing 0.05 mol/L pyrrolidine-acetic acid buffer salt, pH = 10.0). The linearity range is 0.01-120 micro g/L for each metal ion. The detection limits (S/N = 3) of tin, lead, cadmium, and mercury are 0.6, 0.8, 0.5, and 0.6 ng/L, respectively. This method is applied to the determination of tin, lead, cadmium, and mercury in tobacco and it's additive with good results.  相似文献   

5.
A new method for the simultaneous determination of seven heavy metal ions in water by solid-phase extraction and reversed-phase high-performance liquid chromatography (RP-HPLC) was developed. The copper, nickel, cobalt, silver, lead, cadmium, and mercury ions were pre-column derivatized with tetra( m-aminophenyl)porphyrin (T m-APP) to form colored chelates. The metal-T m-APP chelates in 100 mL of sample were preconcentrated to 1 mL by solid-phase extraction with a C(18 )cartridge; an enrichment factor of 100 was achieved. The chelates were separated on a Waters Xterra()RP(18) column by gradient elution with methanol (containing 0.05 mol L(-1) pyrrolidine-acetic acid buffer salt, pH 10.0) and acetone (containing 0.05 mol L(-1) pyrrolidine-acetic acid buffer salt, pH 10.0) as mobile phase at a flow rate of 1.0 mL min(-1) and detected with a photodiode array detector. The detection limits of copper, cobalt, nickel, silver, lead, cadmium, and mercury are 2, 2, 3, 4, 3, 3, and 3 ng L(-1), respectively, in the original sample. The method was also applied to the determination of these metals in water with good results.  相似文献   

6.
Li Z  Li X  Hu Q  Yin J  Chzn J  Yang G 《Annali di chimica》2006,96(5-6):355-363
In this paper, a new method for the simultaneous determination of palladium, platinum and rhodium ions was developed using a rapid column high performance liquid chromatography equipped with on-line enrichment technique. The palladium, platinum and rhodium ions were pre-column derivatized with DHAR to form colored chelates. The Pb-DHAR, Pt-DHAR and Rh-DHAR chelates could be absorbed onto the front of the enrichment column when they were injected into the injector and sent to the enrichment column [ZORBAX Stable Bound, 4.6 x 10 mm, 1.8 microm] with a 0.05 mol L(-1) of phosphoric acid solution as mobile phase. After enrichment, and by switching the six ports switching valve, the retained chelates were back-flushed by mobile phase and traveling towards the analytical column. The separation of these chelates on the analytical column [ZORBAX Stable Bound, 4.6 x 50 mm, 1.8 microm] was satisfactory with 54% acetonitrile (containing 0.05 mol L(-1) of phosphoric acid and 0.1% of tritonX-100) as mobile phase. Palladium, platinum and rhodium were separated completely within 2 min. By on-line enrichment technique, the enrichment factor of 100 was achieved, and the detection limits (S/N = 3) of palladium, platinum and rhodium reaches 1.4 ng L(-1), 1.6 ng L(-1) and 2.0 ng L(-1), respectively. This method was applied to the determination of palladium, platinum and rhodium in water, urine and soil samples with good results.  相似文献   

7.
A simple and fast method for preconcentration and determination of ultra trace amounts of lead(II), mercury(II) and cadmium(II) in water samples is presented. Lead, mercury and cadmium adsorbed quantitatively during passage of water samples (pH?=?7, flow rate?=?20 mL min?1) through octadecyl silica membrane disks modified with 5,5′-dithiobis(2-nitrobenzoic acid). The retained lead, mercury and cadmium are then stripped from the disk with a minimal amount of 1 M hydrochloric acid solution as eluent, and determined by atomic absorption spectrometry. The influence of flow rates of the eluent and sample solution, the amount of ligand, type and least amount of eluent, pH of sample, effect of other ions and breakthrough volume are determined. The breakthrough volume of the method is greater than 2000 mL for lead and greater than 1500 mL for mercury and cadmium, which results in an enrichment factor of 200 for lead and an enrichment factor of 150 for both mercury and cadmium. The limit of detection of the proposed method is 177, 2 and 13 ng l?1 for lead, mercury and cadmium, respectively.  相似文献   

8.
In this paper, 5-(2-hydroxy-5-nitrophenylazo)thiorhodanine (HNATR) was synthesized. A new method for the simultaneous determination of palladium, platinum, rhodium and gold ions as metal-HNATR chelates was developed using a rapid analysis column high performance liquid chromatography equipped with on-line solid phase extraction technique. The samples (Water, human urine, geological samples and soil) were digested by microwave acid-digestion. The palladium, platinum, rhodium and gold ions in the digested samples were pre-column derivatized with HNATR to form colored chelates. The Pd-HNATR, Pt-HNATR, Rh-HNATR and Au-HNATR chelates can be absorbed onto the front of the enrichment column when they were injected into the injector and sent to the enrichment column [Zorbax Stable Bound, 10 mm x 4.6 mm, 1.8 microm] with a buffer solution of 0.05 mol L(-1) phosphoric acid as mobile phase. After the enrichment had finished, by switching the six ports switching valve, the retained chelates were back-flushed by mobile phase and travelling towards the analytical column. These chelates separation on the analytical column [Zorbax Stable Bound, 10 mm x 4.6 mm, 1.8 microm] was satisfactory with 72% acetonitrile (containing 0.05 mol L(-1) of phosphoric acid and 0.1% of Triton X-100) as mobile phase. The palladium, platinum, rhodium and gold chelates were separated completely within 2.5 min. Compared to the routine chromatographic method, more then 80% of separation time was shortened. By on-line solid phase extraction system, a large volume of sample (10 mL) can be injected, and the sensitivity of the method was greatly improved. The detection limits (S/N=3, the sample injection volume is 10 mL) of palladium, platinum, rhodium and gold in the original samples reaches 1.4, 1.8, 2.0 and 1.2 ng L(-1), respectively. The relative standard deviations for five replicate samples were 2.4-3.6%. The standard recoveries were 88-95%. This method was applied to the determination of palladium, platinum, rhodium and gold in human urine, water and geological samples with good results.  相似文献   

9.
A new method for the simultaneous determination of heavy-metal ions in tobacco and tobacco additive by microwave digestion and reversed-phase high-performance liquid chromatography (RP-HPLC) was developed. The tobacco and tobacco additive samples were digested by microwave digestion. The lead, cadmium, mercury, nickel, copper, and tin ions in the digested samples were precolumn derivated with tetra-(4-aminophenyl)-porphyrin (T4-APP) to form color chelates; the Hg-T4-APP, Cd-T4-APP, Pb-T4-APP, Ni-T4-APP, Cu-T4-APP, and Sn-T4-APP chelates were then enriched by solid-phase extraction with C18 disks and the retained chelates were eluted from the disks using tetrahydrofuran (THF). The chelates were separated on a Waters Xterra RP18 column by gradient using methanol (containing 0.05 mol/L pyrrolidine-acetic acid buffer salt, pH 10.0) and acetone (containing 0.05 mol/L pyrrolidine-acetic acid buffer salt, pH 10.0) as a mobile phase at a flow rate of 0.5 mL/min and detected with a photodiode array detector in the range 350–600 nm. The detection limits of lead, cadmium, mercury, nickel, copper, and tin were 5, 4, 2.5, 5, 8, and 4 ng/L, respectively, in the original samples. The method was applied to the determination of lead, cadmium, mercury, nickel, copper, and tin in tobacco and tobacco additive with good results.__________From Zhurnal Analiticheskoi Khimii, Vol. 60, No. 5, 2005, pp. 542–548.Original English Text Copyright © 2005 by Yang, Li, Shi, Wang.This article was submitted by the authors in English.  相似文献   

10.
A comparative study of three mercury chelate forming reagents [diethyldithiocarbamate, pyrrolidin-1-yldithioformate and diphenylthiocarbazone (dithizone)] has been carried out for the preconcentration of ultratrace amounts of inorganic mercury and methylmercury in silica C(18) minicolumns as the solid sorbent. Sample flow injection in-line sorbent extraction was coupled with continuous cold vapour atomic absorption spectrometry (CVAAS) for detection. Results showed the superiority of the carbamate type reagents over the dithizone for the on-line formation and preconcentration of the corresponding mercury chelates. Using diethyldithiocarbamate (DDC) as reagent, aqueous sample volumes of 100 ml can be preconcentrated with 100% efficiency for both inorganic mercury and methylmercury. Quantitative release of the retained DDC chelates was obtained for volumes of eluent (ethanol) of 50 microl. Following the proposed procedure, detection limits of 16 ng/l. of mercury were achieved for sample volumes of 25 ml. The relative standard deviation was +/- 3.4% at 0.5 microg/l. Hg(II) levels. The method has been successfully applied to the determination of low levels of mercury in sea-water.  相似文献   

11.
In this paper, a new method for the simultaneous determination of palladium and platinum ions was developed using a rapid column high performance liquid chromatograph equipped with an on‐line enrichment technique. The palladium and platinum ions were pre‐column derivatized with 5‐(p‐aminobenzylidene)‐thiorhodanine (ABTR) to form colored chelates. The Pd‐ABTR, Pt‐ABTR chelates can be absorbed onto the front of an enrichment column when they were injected into the injector and sent to the enrichment column [ZORBAX Stable Bound, 4.6 × 10 mm, 1.8 μm] with a buffer solution of 0.05 mol/L sodium acetate‐acetic acid buffer solution (pH 3.5) as mobile phase. After the enrichment had finished, by switching the six‐ports switching valve, the retained chelates were back‐flushed by mobile phase and traveled towards the analytical column. These chelates separation on the analytical column [ZORBAX Stable Bound, 4.6 × 50 mm, 1.8 μm] was satisfactory with 65% methanol (containing 0.05 mol/L of pH 3.5 sodium acetate‐acetic acid buffer salt and 0.01 mol/L of tritonX‐100) as mobile phase. The palladium and platinum were separated completely within 2 min. The detection limits (S/N = 3) of palladium and platinum are 1.4 ng/L and 1.6 ng/L, respectively. This method was applied to the determination of palladium and platinum in water and urine samples with good results.  相似文献   

12.
A simple and cost-effective method for speciation analysis of trace mercury in seafood was developed by on-line coupling flow injection microcolumn displacement sorption preconcentration to high-performance liquid chromatography (HPLC) with UV detection. The methodology involved the presorption of the Cu-PDC (pyrrolidine dithiocarbamate) chelate onto a microcolumn packed with a cigarette filter sorbent, simultaneous preconcentration of Hg(II), methylmercury (MeHg), ethylmercury (EtHg), and phenylmercury (PhHg) onto the microcolumn through a displacement reaction with the presorbed Cu-PDC, and their subsequent elution from the microcolumn for on-line HPLC separation. Interferences from heavy metal ions with lower stability of their PDC chelates relative to Cu-PDC were minimized without the need of any masking agents. With the consumption of 4.0 ml of sample solution, the enrichment factors were about 80. The detection limits were 10-25 ng g(-1) (as Hg) in fresh tissue. Precision (R.S.D. (%), n = 5) ranged from 2 to 3% at the 500 microg l(-1) (as Hg) level. The developed technique was validated by analyzing a certified reference material (DORM-2, dogfish-muscle), and was shown to be useful for mercury speciation in real seafood samples.  相似文献   

13.
《Analytical letters》2012,45(14):2463-2474
Abstract

In this paper, 2‐carboxyl‐1‐naphthalthiorhodamine (CNTR) was synthesized, and a new method for the simultaneous determination of palladium, platinum, and rhodium ions as metal‐CNTR chelates was developed using rapid column high performance liquid chromatography combined with on‐line enrichment. The palladium, platinum, and rhodium ions were precolumn derivatized with CNTR to form colored chelates. The Pb‐CNTR, Pt‐CNTR, and Rh‐CNTR chelates could be absorbed onto the front of the enrichment column when they were injected into the injector and sent to the enrichment column (ZORBAX Stable Bound, 4.6×10 mm, 1.8 µm) with a buffer solution of 0.05 mol/L sodium acetate–acetic acid buffer solution (pH 3.5) as mobile phase. After enrichment, and by switching the six ports switching valve, the retained chelates were back‐flushed by mobile phase and traveling towards the analytical column. The separation of these chelates on the analytical column (ZORBAX Stable Bound, 4.6×50 mm, 1.8 µm) was satisfactory with 54% methanol (v/v) in 0.05 mol/L sodium acetate buffer (pH 3.5) containing 1 g/L Triton X‐100 as mobile phase. Palladium, platinum, and rhodium were separated completely within 2 min. The detection limits (S/N=3) of palladium, platinum, and rhodium are 1.4 ng/L, 1.2 ng/L, and 1.8 ng/L, respectively. This method was applied to the determination of palladium, platinum, and rhodium in water, urine, and soil samples with good results.  相似文献   

14.
The well‐known method for the determination of mercury(II), which is based on the anodic stripping voltammetry of mercury(II), has been adapted for applications at the thin film poly(3‐hexylthiophene) polymer electrode. Halide ions have been found to increase the sensitivity of the mercury response and shift it more positive potentials. This behavior is explained by formation of mercuric halide which can be easily deposited and stripped from the polymer electrode surface. The procedure was optimized for mercury determination. For 120 s accumulation time, detection limit of 5 ng mL?1 mercury(II) has been observed. The relative standard deviation is 1.3% at 40 ng mL?1 mercury(II). The performance of the polymer film studied in this work was evaluated in the presence of surfactants and some potential interfering metal ions such as cadmium, lead, copper and nickel.  相似文献   

15.
Sakai Y  Kawano N  Nakamura H  Takagi M 《Talanta》1986,33(5):407-410
N,N'-Bis(2-hydroxy-5-nitrobenzyl)cryptand-22 (22-Koshland) forms yellow complexes with bivalent metal ions, and these are extractable into 1,2-dichloroethane. The overall extraction constants have been estimated for lead (10(-5.4)), copper (10(-5.6)), mercury (10(-5.8)) and cadmium (10(-8.4)). The result obtained has been applied to extraction and photometric determination of lead. The molar absorptivity at the absorption maximum (406 nm) is 4.47 x 10(4) l.mole(-1).cm(-1). The interferences from copper and mercury can be eliminated by the addition of sodium thiosulphate and the interference from cadmium can be eliminated by calculation from the absorbances at 406 and 391 nm (the cadmium complex with 22-Koshland has its absorption maximum at 391 nm). The method has been successfully applied to the determination of lead in zinc powder.  相似文献   

16.
A new method for the simultaneous determination of five transition metal ions in water and food by rapid high‐performance liquid chromatography was developed. The cobalt, nickel, copper, zinc and vanadium ions were pre‐column derivatized with 2‐(2‐quinolinylazo)‐4‐methyl‐1,3‐dihydroxidebenzene (QAMDHB) to form colored chelates, then the Co‐QAMDHB, Ni‐QAMDHB, Cu‐QAMDHB, Zn‐QAMDHB and V‐QAMDHB chelates were enriched by solid phase extraction with a C18 cartridge. The enrichment factor of 50 was achieved by eluting the retained chelates from the cartridge with tetrahydrofuran (THF). These chelates were separated on a ZORBAX Stable Bound rapid analysis column (4.6 × 50 mm, 1.8 um) with 68% methanol (containing 0.1% of acetic acid and 0.1% of CTMAB) as mobile phase at a flow rate of 2.0 mL/min and detected with a photodiode array detector from 450?600 nm. The Co‐QAMDHB, Ni‐QAMDHB, Cu‐QAMDHB, Zn‐QAMDHB and V‐QAMDHB chelates were separated completely within 2.0 min. The detection limits of cobalt, nickel, copper, zinc and vanadium are 2 ng/L, 1.5 ng/L, 2 ng/L, 3 ng/L, and 3 ng/L, respectively, in the original samples. This method was applied to the determination of the five transition metal ions in water and food samples with good results.  相似文献   

17.
The Amberlite XAD resins coated with dithiosemicarbazones were prepared and their collection behavior of metal ions from aqueous solution was investigated. Among the resins used, the reagent-loaded Amberlite XAD-7 was found to be superior for the collection of metal ions to other reagent-loaded resins used. The quantitative collection of mercury(II), palladium(II) and copper(II) was obtained from acidic medium, while cadmium(II) and lead(II) was obtained from neutral medium by the Amberlite XAD-7 resin coated with dimethylglyoxal bis(4-phenyl-3-thiosemicarbazone) (DMBS). These metal ions collected on the resin were easily eluted with a small volume of N,N-dimethylformamide as their DMBS chelates. This collection-elution method was applied to the determination of their metal ions by reversed-phase high performance liquid chromatography with a spectrophotometric detection.  相似文献   

18.
本文报道了流动注射在线柱预富集ICP光谱测定痕量金属的方法,以meso-四(4-磺基苯)卟啉为柱前衍生试剂,硅胶作固定相和盐酸作洗脱液,对痕量金属离子Cu、Mn、Ni、Fe、Pb、Cd进行在线预富集检测。在给定实验条件下,方法的富集倍数为9.3~11.3,检出限和测定的相对标准偏差(n=6)分别在0.32~26.8ng/ml和1.3%~3.0%范围内。方法用于小牛肝和西红柿叶样品分析,结果与参考值吻合。  相似文献   

19.
In the present work, 4-carboxylphenyl-thiorhodanine (CPTR) was synthesized. A new method for the simultaneous determination of palladium, platinum, and rhodium ions as metal-CPTR chelates was developed using rapid column high-performance liquid chromatography equipped with an online enrichment capability. Palladium, platinum, and rhodium ions were precolumn-derivatized with CPTR to form colored chelates. The Pd-CPTR, Pt-CPTR, and Rh-CPTR chelates can absorbed onto the front of the enrichment column (ZORBAX Stable Bound, 4.6 × 10 mm, 1.8 μm) when they are injected with a buffer solution of 0.05 M sodium acetate-acetic acid (pH 3.5) as mobile phase. After the enrichment had finished, by switching the six-port switching valve, the retained chelates were back-flushed by mobile phase and moved towards the analytical column. The chelate separation on the analytical column (ZORBAX Stable Bound, 4.6 × 50 mm, 1.8 μm) was achieved with 46% acetonitrile (containing 0.05 M of pH 3.5 sodium acetate-acetic acid buffer and 0.01 M tritonX-100) as mobile phase. The palladium, platinum, and rhodium were separated completely within 2 min. The detection limits (S/N = 3) of palladium, platinum, and rhodium are 1.4, 1.6, and 2.0 ng/L, respectively. The method was applied to the determination of palladium, platinum, and rhodium in water, urine, and soil samples with good results. The text was submitted by the authors in English.  相似文献   

20.
A simple and sensitive preconcentration analysis-atomic absorption spectrometric procedure is described for the determination of lead, cadmium and nickel. The method is based upon on-line preconcentration of metal ions on a minicolumn of Cibacron Blue F3-GA immobilized on poly(hydroxyethylmethacrylate), poly(HEMA). The enrichment factors obtained were 42 for lead, 52 for cadmium and 63 for nickel (sample volume 10 mL and sample flow rate 5 mL/min). The relative standard deviations (n = 10), in 10 mL sample solutions containing 100 microg/L Pb(2+), 10 microg/L Cd(2+) and 100 microg/L Ni(2+) were 8.9, 3.7 and 3.5%, respectively. The limits of detection (blank + 3s) (n = 10), were found to be 12.01 microg/L for Pb(2+), 1.34 microg/L for Cd(2+) and 28.73 microg/L for Ni(2+). The accuracy of the system was checked with certified and tap water samples spiked with known amounts of metal ions. No significant difference was found between the achieved results and the certified values.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号