首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The effect of methanol, acetone and acetonitrile on the sensitivity, selectivity and the detection limits (LODs) of the determination of chromium species by ion chromatography was investigated. A collinear dual-beam thermal lens spectrometer was used for the direct detection of chromium complexes [pre-column derivatized Cr(III)–pyridine-2,6-dicarboxylic acid, and post-column derivatized Cr(VI)–1,5-diphenylcarbazide] following the ion chromatographic separation on a Dionex HPIC-CS5A solvent compatible column. Different amounts of organic solvents were added directly to the eluent (up to 30%) and to the post-column reagent (up to 60%) to improve the thermooptical properties of the solvents. Consequently, the sensitivity of the technique was increased by a factor of 2–3 and LODs of 0.1 and 10 μg dm−3 were achieved for Cr(VI) and Cr(III), respectively, when the eluent reaching the detector contained 30% of acetonitrile. The addition of organic solvents also resulted in significant changes in retention times, which improved the Cr(III)/Cr(VI) separation.  相似文献   

2.
In the absence of any special luminescent reagents, a weakly chemiluminescent emission was observed during the decomposition of hydrogen peroxide, catalyzed by transition-metal ions, such as Cu(II) and Co(II), in basic aqueous solution. The chemiluminescent intensity was significantly enhanced by the addition of ethyldimethylcetylammonium bromide and uranine. The signal-to-noise ratio (S/N) was proportional to the concentrations of Cu(II) and Co(II). Based on these phenomena, a flow-injection chemiluminescent method for the simultaneous separation and determination of Cu(II) and Co(II) was developed. The detection limits of the present chemiluminescent method for Cu(II) and Co(II) were 7.5 and 0.01 ng/ml, respectively. After ion chromatographic separation of Cu(II) and Co(II) by an IonPac CS5A column with oxalic acid and lithium hydroxide monohydrate as the eluent, the present chemiluminescent system was used as a post-column detector for these two transition metal ions in natural water samples.  相似文献   

3.
This paper describes an indirect method for the quantification of the toxic military agent O-ethyl S-(2-diisopropylaminoethyl) methylphosphonothioate (VX) in the vapor state in air or other similar gases at ng/m3 levels. The method begins with the passage of a gaseous sample through a filter impregnated with silver fluoride to convert the VX vapor to ethyl methylphosphonofluoridate. The latter compound is then trapped on a bed of Chromosorb 106, transferred to a smaller bed of the same sorbent, and desorbed thermally into a gas chromatograph equipped with a flame-photometric detector. The method is comparable in sensitivity to the principal alternative method, which is based on cholinesterase inhibition, and it is less subject to interference from common organic solvents and other cholinesterase inhibitors. The detection limit was found to be limited by, and therefore dependent on, the nature and extent of any background substances that produced a significant chromatographic signal or response at the retention time of the analyte. In the absence of such substances, the instrument provided a response to 0.19 ng of VX that was thirty times larger than the peak-to-peak noise amplitude on the chromatographic base line. Moreover, the method bias (i.e., 100% minus the percent VX recovery) was found to depend on VX concentration, with estimates of agent recovery ranging from 83% at a VX concentration of 0.67 ng/m3 to 104% at a concentration of 0.084 ng/m3. The relative standard deviation varied with VX concentration and with the nature of the test that was performed to estimate it. It ranged from 2.1% in one VX vapor-challenge test to 17% in an experiment involving spiked sampling tubes, and it was generally lower at the higher VX test concentrations.  相似文献   

4.
A. Mandl  W. Lindner 《Chromatographia》1996,43(5-6):327-330
Summary An improved, reversed-phase, high-performance liquid chromatography (HPLC) method with dual UV-fluorescence detection for simultaneous determination of the antifolate methotrexate, the folate leucovorin and their two main metabolites 7-hydroxymethotrexate and 5-methyltetrahydrofolate, respectively is presented. The fluorescence intensity of leucovorin could be significantly increased by on-line, post-column irradiation with UV at 254 nm thus lowering the limit of detection for leucovorin to 0.2 ng absolute at a signal-to-noise ratio 31.  相似文献   

5.
Patel BM  Moye HA  Weinberger R 《Talanta》1991,38(8):913-922
The ultraviolet (UV) photolysis of several classes of nitrogenous pesticides was examined with a view to photo-induced fluorescence detection in flow-injection analysis (FIA) and liquid chromatography. The solvents evaluated as typical reversed-phase mobile phases included water, methanol, and 1:1 mixtures of methanol/water and acetonitrile/water, and methanol/acetonitrilelwater mixtures. Acetone, acetophenone, the surfactant triton X-100, and the photocatalyst titanium dioxide were assessed as photosensitizers to enhance the UV photolysis and fluorescence responses. FIA and liquid chromatographic separations of several pesticides were followed by post-column UV photolysis for the fluorescence detection. Ultraviolet photolysis produces some fluorescent products. The type of photolytic solvent seems to play a significant role. The presence of photosensitizers also affects the fluorescence response of some pesticides. The photochemical transformation products of some of the pesticides are suggested. Analytical figures of merit were evaluated for determination of several pesticides in ground water. The post-column UV photolysis approach for fluorescence detection in liquid chromatography was assessed for several nitrogenous pesticides in ground water samples at ng/g concentrations.  相似文献   

6.
An ion chromatography method for the simultaneous determination of trace iodate, chlorite, chlorate, bromide, bromate and nitrite in drinking water has been developed using an anion-exchange column and the suppressed conductivity detector, followed by post-column addition of reagent to enhance visible absorbance detection of ions. A high capacity anion exchange Ion Pac9-HC column (250 mm x 4 mm I.D.) was used. Eight millimole per liter sodium carbonate was used as eluent, an auto-suppression external water mode was selected, 0.5 g/l o-dianisidine.2HCl (ODA)+4.5 g/l KBr+25% methanel+5.6% nitric acid was used as post-column reagent. The post-column reaction (PCR) temperature was at 60 degrees C, and the visible absorbance detected wavelength at 450 nm. The sample's pH and coexist anions had no influence on determination. The method enjoyed a wide linear range and a good linear correlation coefficient (r>0.999). The method detection limits were between 0.023 and 2.0 microg/l. The average recoveries ranged from 87.5 to 110.0%, and the relative standard deviations (RSD) were in the range of 1.1-4.6%. The analytical results by the method of post-column addition of reagent to enhance visible absorbance detection of anions was compared with that of the suppressed conductivity detection, and the former was proved to be better in sensitivity and selectivity. The results showed that this method was accurate, sensitive and might be good for application and suitable for trace analysis at the level of mug/l.  相似文献   

7.
Atmospheric pressure photoionization mass spectrometric (APPI-MS) study on three types of polyisobutylene derivatives is reported. Two of the polyisobutylenes investigated were polyisobutylene with dihydroxy and diolefinic end-groups derived from aromatic moieties [dicumyl chloride, 1,4-bis(2-chloro-2-propyl)benzene], and the third contained no aromatic moieties with a monohydroxy end-group. All three polyisobutylene derivatives (PIBs) had an average molecular weight (M(n)) of approximately 2000 g/mol, with a polydispersity lower than 1.2. In the positive ion APPI mode, protonated PIB molecules were formed, but the molecular weights obtained were considerably lower than those expected, indicating fragmentation of the PIB chains. In the negative APPI mode, using solvents such as tetrahydrofuran and toluene as dopants, no signal was obtained. However, in chlorinated solvents, such as CCl(4), CHCl(3), and CH(2)Cl(2), in the presence of toluene dopant, PIB adducts with chloride ions were formed with relatively high signal intensity. In the case of CH(2)Cl(2), no dopant (toluene) was necessary to generate chlorinated adduct ions, albeit increasing the toluene concentration in the flow increased the PIB signal intensity. The effect of the toluene concentration on PIB signal intensity was studied and models that include (1) photoionization of toluene, (2) formation of chloride ions from the chlorinated solvents by dissociative electron capture, (3) formation of chlorinated adduct ions and charge recombination reactions between the toluene radical cation, (4) chloride ions, and (5) chlorinated adduct ions are proposed based on the experimental results.  相似文献   

8.
The compatibility of liquid chromatography solvents with oxidizing reagents frequently employed in direct chemiluminescence reactions is examined in this study. Various oxidizing reagents were examined for their response in hydro-organic and micellar mobile phases in both isocratic and gradient elution modes. Mild oxidants like hydrogen peroxide, periodate, cerium and hypochlorite were found to be completely compatible with common reversed phase HPLC solvents posing as no threat to the detection procedure. On the other hand, stronger oxidants like acidic permanganate were found to oxidize organic solvents towards the production of an intense light signal. Although several analytical applications can emerge from this finding, the conjunction of this system with reversed phase HPLC is impractical owing to a significant baseline increase which deteriorates the sensitivity of the analysis. A convenient solution to this problem is proposed based on the regulated on-line post-column pre-oxidation of the organic solvent (SPOC) with mild oxidants that have no influence on the final signal. The analytical utility of this new approach in the determination of organic compounds after chromatographic separation is demonstrated.  相似文献   

9.
Separative method of lipid classes from the stratum corneum was developed with packed silica and supercritical CO2 containing 10% of methanol at 15 degrees C, 15 MPa and 3 ml min(-1). The elution order of lipid classes was first esterified cholesterol, triglycerides, squalene co-eluted in a single peak, then free fatty acids, free cholesterol, ceramides and finally glycosylceramides. The ceramides were eluted in several fractions which depended on the number of hydroxyl groups in the molecule, i.e. more hydroxyl groups were contained in ceramides, more important was the retention. Moreover, the retention was not altered by the presence of carbon double bond and variation of the alkyl chain length. The ceramide response with the evaporative light scattering detector was improved by turning the influence of the solvent nature on the response to advantage. Therefore, addition of various solvents with or without triethylamine and formic acid were tested in post-column due to the incompatibility of such modifiers with silica stationary phase. Thereby the solvent conditions for the separation and the detection can be adjusted almost independently. The response was greatly increased by post-column addition of 1% (v/v) triethylamine and its equivalent amount of formic acid in dichloromethane introduced at 0.1 ml min(-1) into the mobile phase. This device had allowed the detection of 400 ng of ceramide with a S/N = 21, whereas no peak was observed in absence of the post-column addition. Finally, the method was applied to the treatment of skin sample which led to highly enriched ceramide fraction.  相似文献   

10.
A solid-phase microextraction (SPME) and gas chromatography-mass spectrometry (GC-MS) sampling and analysis method was developed for bis(diisopropylaminoethyl)disulfide (a degradation product of the nerve agent VX) in soil. A 30-min sampling time with a polydimethylsiloxane-coated fiber and high temperature alkaline hydrolysis allowed detection with 1.0 microg of VX spiked per g of agricultural soil. The method was successfully used in the field with portable GC-MS instrumentation. This method is relatively rapid (less than 1 h), avoids the use of complex preparation steps, and enhances analyst safety through limited use of solvents and decontamination of the soil before sampling.  相似文献   

11.
A novel technique, "segmented post-column analyte addition", is proposed to visualize and compensate signal suppression/enhancement effects in electrospray ionization tandem mass spectrometry (ESI-MS/MS). Instead of delivering a constant flow of analyte solution between the liquid chromatography (LC) column exit and the ESI interface into the eluent resulting from LC separation of analyte-free matrix in order to determine retention time widows in which suppression/enhancement is unimportant (King et al., J. Am. Soc. Mass Spectrom. 2000; 11: 942), segmented packets of analyte-containing solvent and analyte-free solvent were infused into an LC eluent resulting from separation of an analyte-containing sample. The obtained, superimposed, periodic spikes are much narrower than the analyte peak eluting from the column. The height of the spikes is affected by signal suppression phenomena to the same extent as the analyte signal, and hence variations of the spike height can be used to correct the peak area of analyte peaks affected by signal suppression/enhancement.  相似文献   

12.
A rapid analytical procedure was developed and tested for routine identification and quantification of methylbenzoquate in feeds by liquid chromatography (LC). The ground feed samples were extracted using methanol-water (80 + 20, v/v) at 65 degrees-70 degrees C in a water bath for premixes and in dichloromethane at 45 degrees C in a water bath for final feeds, respectively. The extract of final feeds was cleaned using solid-phase extraction on silica columns. Both the final feed and premix extracts were analyzed by reversed-phase LC on a NovaPak C18 column (3.9 x 150 mm; 4 microm) with methanol-acetonitrile-water-phosphoric acid (340 + 350 + 308 + 2, v/v) as mobile phase. Fluorescence detection was performed at excitation and emission wavelengths of 265 and 390 nm, respectively. Alternatively, post-column addition of sulfuric acid solution was used to decrease the determination limit. The recovery of methylbenzoquate, in a concentration range of 0.5-10 mg/kg, was 105.0 +/- 7.3%. The limit of quantitation, based on a signal-to-noise ratio of 10:1, was 48 microg/kg. The developed LC method was tested in an interlaboratory study. The interlaboratory repeatibility for both samples ranged from 7.1 to 10.6%; the interlaboratory reproducibility ranged from 11.7 to 15.2%. With the post-column addition of sulfuric acid, the limit of quantification was decreased by a factor of 50. Overall, the developed method is highly selective and can be used in routine analysis.  相似文献   

13.
采用电喷雾萃取电离质谱(EESI-MS)分析致癌性环境有机污染物多环芳烃(PAHs)生物标志物1-羟基芘(1-OHP),探究1-OHP在EESI源中电离的可行性,考察ESI溶剂和样品溶液组成对方法灵敏度的影响,初步建立I-OHP的EESI MS半定量分析方法.结果表明,溶液中1-OHP能够在EES1源中有效电离,生成准分子离子[M-H]- (m/z 217),并得到其二级质谱特征碎片离子[M- H- CO]- (m/z 189);水、甲醇、乙醇、正丙醇和正丁醇5种ESI溶剂中,使用甲醇时,离子峰m/z 217信噪比最大.样品溶液中甲醇含量越高,离子峰m/z 217强度越强.离子峰m/z 217强度与1-OHP浓度在10~200 μg/L内的线性相关性相对最好;相关系数(R)0.982;相对标准偏差(RSD)为3.4%~14.0%(n=5);定量下限约为10 μg/L(S/N=10);单次检测时间小于0.5 min.  相似文献   

14.
Methyl cellulose (MC) was partially depolymerised and the oligomers thus obtained were studied by matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOFMS). The depolymerisation was either enzymatic or acidic. Fractions of enzymatically depolymerised MC were collected from size-exclusion chromatography and subjected to a sample preparation investigation. Several MALDI matrices and solvents were evaluated. The results showed that the solvent choice had a significant effect on the measured degree of substitution (DS). Aprotic solvents produced higher DS values, which was most likely due to poor solubility of species with low DS. The obtained signal intensity, however, did not correlate with the solubility but seemed to be more dependent on certain matrix/solvent combinations. All the matrices attempted produced mass spectra with sufficient signal intensity for accurate peak area calculation. The choice of matrix did not have any significant effect on the measured DS. Sample spots obtained from organic solvents had a more homogeneous distribution of the analyte and smaller crystals than those obtained from water. This increased both the reproducibility and peak resolution and in addition the analysis time was shorter. DS measurements were performed on two acidically depolymerised MCs with different nominal DS values. It was easy to distinguish between the two MCs, and the measured DS values agreed well with the values supplied by the manufacturers.  相似文献   

15.
Cysteine sulfonic acid-containing peptides, being typical acidic peptides, exhibit low response in matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. In this study, matrix conditions and the effect of diammonium hydrogencitrate (DAHC) as additive were investigated for ionization of cysteine sulfonic acid-containing peptides in MALDI. A matrix-free ionization method, desorption/ionization on porous silicon (DIOS), was also utilized to evaluate the effect of DAHC. When equimolar three-component mixtures of peptides carrying free cysteine, cysteine sulfonic acid, and carbamidomethyl cysteine were measured by MALDI using a common matrix, alpha-cyano-4-hydroxycinnamic acid (CHCA), no signal corresponding to cysteine sulfonic acid-containing peptide could be observed in the mass spectrum. However, by addition of DAHC to CHCA, the peaks of cysteine sulfonic acid-containing peptides were successfully observed, as well as when using 2,4,6-trihydroxyacetophenone (THAP) and 2,6-dihydroxyacetophenone with DAHC. In the DIOS mass spectra of these analytes, the use of DAHC also enhanced the peak intensity of the cysteine sulfonic acid-containing peptides. On the basis of studies with these model peptides, tryptic digests of oxidized peroxiredoxin 6 were examined as a complex peptide mixture by MALDI and DIOS. In MALDI, the peaks of cysteine sulfonic acid-containing peptides were observed when using THAP/DAHC as the matrix, but this was not so with CHCA. In DIOS, the signal from cysteine sulfonic acid-containing peptides was suppressed; however, the use of DAHC significantly enhanced the signal intensity with an increase in the number of observed peptides and increased signal-to-noise ratio in the DIOS spectra. The results show that DAHC in the matrix or on the DIOS chip decreases discrimination and suppression effects in addition to suppressing alkali-adduct ions, which leads to a beneficial effect on protonation of peptides containing cysteine sulfonic acid.  相似文献   

16.
本研究采用紫外光离子源-高场不对称波形离子迁移谱(UV-FAIMS)快速检测环境中挥发性有机物.选取苯和对二甲苯为研究对象,并分析了分离电压、流速等因素对其分离识别的影响.实验结果表明:当分离电压值为0~1200 V时,苯和对二甲苯信号强度逐渐降低,而特征补偿电压值却逐渐增加.实验选取分离电压值为900 V,当载气流速为0~240 L/h时,苯和对二甲苯的特征离子峰信号强度逐渐增加,当载气流速为0~120 L/h时,苯和对二甲苯团簇峰信号强度增加,当载气流速为120~240 L/h时,苯的团簇峰信号强度增加,而对二甲苯的团簇峰信号强度降低.此外,对样品浓度、信号强度与噪声的比值进行探讨,获得UV-FAIMS检测苯的检测限为0.011mg/m3.  相似文献   

17.
The chemiluminescence reaction between an aryl oxalate, hydrogen peroxide and a fluorescent compound is well known for use in h.p.l.c. post-column reactors. Here, several aryl oxalates are evaluated for this purpose in terms of intensity, rate of chemiluminescence decay, solubility in different solvents, and stability in the presence of hydrogen peroxide. Five oxalates are selected for different pH ranges of column eluates: bis(pentafluorophenyl) oxalate for pH < 2, bis(2,4-dinitrophenyl) oxalate for pH 2–4, bis(2-nitrophenyl) oxalate for pH 4–6, bis(2,4,6-trichlorophenyl) oxalate for pH 6–8, and bis(2,4,5-trichlorophenyl-6-pentyloxycarbonyl) oxalate for pH > 8.  相似文献   

18.
Wenxu Lv 《Talanta》2010,80(3):1406-240
This study compares and evaluates the effect of various matrices on liquid chromatography (LC) coupled with tandem mass spectrometry (MS/MS) analysis. Permanent post-column infusion (PCI) was used to quantify matrix effects. In this way, the suppressed or enhanced signal of the target material resulting from different co-eluting matrix components could be assessed. Twenty-four biological samples from in vivo and in vitro experiments were selected for this study. In addition, 7 sample components were further analyzed after sample preparation by protein precipitation. Multiple regression analysis was used to investigate the collinear relationship between matrix effects and co-eluted components at different time intervals. We found that salt was the dominant factor which impacted changes in signal detection. In order to eliminate it, we used ammonium formate as a modifier of the mobile phase which resulted in charge-state redistribution profiles so that a homogeneous matrix formed. By employing pulse gradient chromatography in the presence of 5 mM ammonium formate, favorable improvements of enhanced signal intensity and reduced matrix effects were obtained. These experiments also indicated the feasibility of using analogue IS during bio-analysis which contributed to an overall faster assay that would be suitable for drug discovery and development purposes.  相似文献   

19.
Gadolinium is a paramagnetic relaxation enhancement (PRE) agent that accelerates the relaxation of metabolite nuclei. In this study, we noted the ability of gadolinium to improve the sensitivity of two-dimensional, non-uniform sampled NMR spectral data collected from metabolomics samples. In time-equivalent experiments, the addition of gadolinium increased the mean signal intensity measurement and the signal-to-noise ratio for metabolite resonances in both standard and plasma samples. Gadolinium led to highly linear intensity measurements that correlated with metabolite concentrations. In the presence of gadolinium, we were able to detect a broad array of metabolites with a lower limit of detection and quantification in the low micromolar range. We also observed an increase in the repeatability of intensity measurements upon the addition of gadolinium. The results of this study suggest that the addition of a gadolinium-based PRE agent to metabolite samples can improve NMR-based metabolomics.  相似文献   

20.
A number of papers have reported the potential advantages of adding water-mixed organic solvents into the analyte solution. It is essential that understanding of the analytical behavior of adding water-mixed organic compounds into the analyte solution in ICP-MS. The purpose of this work was to determine the effect of the addition of various types of water-mixed organic solvents on the signal intensity of different ionization potential elements by ICP-MS.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号