首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 953 毫秒
1.
A simple and reliable solid-phase extraction (SPE) method has been developed to synthesise two new sorbents: 6-propyl-2-thiouracil and 5,6-diamino-2-thiouracil physically loaded onto alumina surface, phases I and II, respectively. The synthesis of these new phases has been confirmed by IR-spectroscopy. The surface concentrations of the organic moieties were determined to be 0.182 and 0.562 mmol g?1 for phases I and II, respectively. The evaluation of the selectivity and metal uptake properties incorporated in these two alumina phases were also studied and discussed for 10 different metal ions: Ca(II), Fe(III), Co(II), Ni(II), Cu(II), Zn(II), Cd(II), Hg(II), Pb(II) and Ag(I) under different controlling factors. The data obtained clearly indicated that the new SP-extractors have the highest affinity for retention of Hg(II) ions. Selective separation of Hg(II) from Ag(I) as one of the most interfering ion, in addition to the other eight coexisting metal ions under investigation, was achieved successfully using the new sorbents at pH = 9.0 under static conditions. Therefore, Hg(II) exhibits major retention percentage (100.0%) using phase I or II. However, Ag(I) exhibits minor retention percentage equal to 1.33% using phase I and 0.67% using phase II. On the other hand, the retention percentage of the other eight metal ions ranged (0.0–3.08%) using phase I and (0.0–1.54%) using phase II at the same pH. The new phases were applied for separation and determination of trace amounts of Hg(II) and Ag(I) spiked natural water samples using cold vapour atomic absorption spectroscopy and atomic absorption spectroscopy with no matrix interference. The high recovery values of Hg(II) and Ag(I) obtained using phases I and II were ranged 98.9 ± 0.1–99.2 ± 0.05% along with a good precision (RSD% 0.01–0.502%, N = 3) demonstrate the accuracy and validity of the new sorbents for separation and determination of Hg(II) and Ag(I).  相似文献   

2.
The modified sorbents with dithizone and zinc dithizonate adsorbed on the silica surface were obtained. The adsorption of heavy metal ions from aqueous solutions onto loaded silicas was studied. Color scales for Ag(I), Hg(II) and Pb(II) visual test detection were worked out. The modified silica gels were established to be applicable to semi-quantitative determination of these metal ions in buttermilk, natural, mineral and waste water.  相似文献   

3.
A simple, rapid, and sensitive method has been developed for the simultaneous determination of trace amounts of copper and silver using 1-phenyl-1,2-propanedione-2-oximethiosemicarbazone (PPDOT) as a chromogenic reagent. The proposed method was based on retention and preconcentration of the complexes Cu(III)-PPDOT and Ag(I)-PPDOT on a solid phase in acid medium. The complexes were quantitatively retained in the cation exchanger SP Sephadex C25, and the analytical measurements were executed directly in the solid phase by derivative spectrophotometry. In this simultaneous determination, the second derivative and the zero crossing method were used. The determination of copper and silver was carried out to 321.0 and 427.0 nm, respectively. In order to obtain quantitative recoveries of the metal ions, various experimental analytical parameters, such as pH, stirring time, volume, and amount of solid phase, were optimized. The effect of interfering ions on the determination was described. The recovery values for Cu(II) and Ag(I) were found to be > 98%, and the relative standard deviation was < or = 2%. The detection limits (3sigma criterion) for Cu(II) and Ag(I) were found to be 0.9 x 10(-8) and 13 x 10(-8) M, respectively. The developed method was utilized for preconcentration and determination of Cu(II) and Ag(I) in industrial effluents and natural water samples. The results were consistent with those provided by inductively coupled plasma/mass spectrometry.  相似文献   

4.
Two novel azocalix[4]pyrrole Amberlite XAD-2 polymeric chelating resins were synthesized by covalently linking diazotized Amberlite XAD-2 with calix[4]pyrrole macrocycles. The chelating resins were used for extraction, preconcentration and sequential separation of metal ions such as Cu(II), Zn(II) and Cd(II) by column chromatography prior to their determination by UV/vis spectrophotometry or flame atomic absorption spectrophotometry (FAAS) or inductively coupled plasma atomic emission spectroscopy (ICP-AES). Various parameters such as effect of pH on absorption, concentration of eluting agents, flow rate, total sorption capacity, exchange kinetics, preconcentration factor, distribution coefficient, breakthrough capacity and resin stability, were optimized for effective separation and preconcentration. The resin showed good ability for the separation of metal ions from binary and ternary mixture on the basis of pH of absorption and concentration of eluting agents. The newly synthesized resins showed good potential for trace enrichment of Cu(II), Zn(II) and Cd(II) metal ions, especially for Cu(II), as compared to the earlier reported resins. The synthesized resins were recycled at least 8-10 times without much affecting column sorption capacity. The presented method was successfully applied for determination of Cu(II), Zn(II) and Cd(II) in natural and ground water samples.  相似文献   

5.
A new adsorbent is synthesized on the basis of silica consecutively modified by polyhexamethylene guanidine and 4,5-dihydroxy-1,3-benzenedisulfonic acid (Tiron) for the group preconcentration of Fe(III), Al(III), Cu(II), Pb(II), Zn(II), and Mn(II) followed by determination by inductively coupled plasma atomic emission spectrometry. The adsorbent in the batch mode quantitatively (recovery 98?99%) extracts Fe(III), Al(III) and Cu(II) ions at pH 4.0 and Fe(III), Al(III), Cu(II), Pb(II), Zn(II), and Mn(II) ions at pH 7.0; the time of attainment of an adsorption equilibrium does not exceed 10 min. Consecutive preconcentration at pH 4.0 and 7.0 in the batch and dynamic modes ensures the quantitative separation of Fe(III), Al(III), and Cu(II) from Pb(II), Zn(II), and Mn(II) and their separate determination. The quantitative desorption of metals was attained with 0.5?1.0 M HNO3 (5 or 10 mL). In preconcentration from 200 mL of solution with 5 mL of a desorbing solution, the preconcentration coefficient was equal to 40. The developed procedure was used for the determination of metal ions in river waters of Krasnoyarsk Krai. The results obtained were verified by the added?found method.  相似文献   

6.
Mahmoud ME 《Talanta》1997,45(2):309-315
The immobilization of silica gel surface with Eriochrome black-T indicator (ERT) for the formation of silica-ERT phase is described. The surface coverage of silica gel, based on carbon and nitrogen analysis of the modified silica gel phase, is 0.38 mmol g(-1). The stability towards hydrolysis of silica-ERT phase in different buffer solutions (pH 1-10) is studied and evaluated. The applicability of silica-ERT as a solid phase extractor for Zn(II), Mg(II) and Ca(II) is studied by the batch equilibrium technique and found to show an order similar to the formation constant values of these three metal ions with the indicator. The selectivity of silica-ERT phase towards the extraction of a certain metal ion from a mixture containing only two metal ions is studied by the batch equilibrium technique and exhibited good discrimination orders for Zn(II) and Mg(II) in presence of Ca(II). The results of the column separation and preconcentration studies are consistent with the selectivity behaviour of silica-ERT phase, thus affording reasonable separation of the three studied metal ions.  相似文献   

7.
We describe a solid phase extractor for selective separation and preconcentration of Hg(II) ion. It was prepared by immobilizing the adduct of diethylenetriamine and thiourea on silica gel. The effects of solution acidity, preconcentration time, sample flow rate and volume were optimized. The results show that Hg(II) can be selectively extracted from acidic solutions and in presence of common other metal ions. The adsorbent is stable, can be reused more than 10 times, and the maximum adsorption capacity is 23 mg g?1. Hg(II) was quantified by inductively coupled plasma optical emission spectrometry. The method has a detection limit of 23 ng L?1, and the relative standard deviation is <2 %. The procedure was validated by analyzing two standard materials (river sediment and hair powder), and was successfully applied to the preconcentration of Hg(II) in real samples.
Figure
A solid phase extractor was firstly prepared by immobilizing DETA-TU (equimolar adduct of diethylenetriamine and thiourea) on the silica gel, which was applied to selectively separate/preconcentrate trace Hg(II) from real samples  相似文献   

8.
Amidino-thiourea immobilized glass beads (AGB I) were prepared and used as the microcolumn packing for the flow injection (FI) on-line separation and preconcentration of Ag(I) coupled with atomic absorption spectrometry (AAS) determination. Base metal ions and anions with a concentration of 2.0 mg mL(-1) had no interference with the determination of Ag(I). The limit of detection (LOD) of Ag(I) for a preconcentration time of 60 s with a sampling flow rate of 5.0 mL min(-1) for 40.0 ng mL(-1) of Ag(I) were 0.50 ng mL(-1) with the peak-height absorbance mode and 1.26 ng mL(-1) with the peak-area absorbance mode, respectively. The relative standard deviations (RSD) of 7 replicate determinations were 0.9% and 0.7% for the peak-height absorbance (H) and the peak-area absorbance (A), respectively. The method was successfully applied to the determination of Ag(I) in ore samples.  相似文献   

9.
Preconcentration/separation of Co(II), Fe(III), Pb(II), Cr(III), Cu(II) and Cd(II) ions using bis(5‐bromo‐2‐hydroxy‐benzaldehyde)‐2‐methyl‐1,5‐pentane diimine (BBHBPDI) on SDS coated alumina has been reported. The influences of the analytical parameters including pH, ligand and SDS amount, type and concentration of eluent and sample volume on metal ions recoveries were investigated. At optimum values of all variables the relative standard deviation are between 2.5–2.7 and preconcentration factor was 375, while recoveries for all understudy metal ions are higher than 95%, determination limits are between 1.5–2.7. The method has been successfully applied to determination of Co(II), Fe(III), Pb(II), Cr(III), Cu(II) and Cd(II) ions content in some real samples.  相似文献   

10.
Silica gel was firstly functionalised with aminopropyltrimethoxysilane obtaining the aminopropylsilica gel (APSG). The APSG was reacted subsequently with morin yielding morin-bonded silica gel (morin-APSG). The structure was investigated and confirmed by elemental and thermogravimetric analyses, IR and (13)C NMR spectral studies. Morin-APSG was found to be highly stable in common organic solvents, acidic medium (<2molL(-1) HCl, HNO(3)) or alkaline medium up to pH 8. The separation and preconcentration of Ag(I), Au(III), Pd(II), Pt(II) and Rh(III) from aqueous medium using morin-APSG was studied. The optimum pH values for the separation of Ag(I), Au(III), Pd(II), Pt(II) and Rh(III) on the sorbent are 5.7, 2.2, 3.7, 3.7 and 6.8, giving rise to separation efficiencies of 43.9, 85.9, 97.7, 60.9 and 91.0%, respectively, where the activity was found to be >90% in the presence of acetate ion. The ion sorption capacity of morin-APSG towards Cu(II) at pH 5.5 was found to be 0.249mmolg(-1) where the sorption capacities of Ag(I) and Pd(II) were 0.087 and 0.121mmolg(-1) and 0.222 and 0.241mmolg(-1) at pH 2.2 and 5.7, respectively. This indicates a 1:1 and 1:2 morin/metal ratios at pH 2.2 and 5.7, respectively. Complete elution of the sorbed metal ions was carried out using 10mL (0.5molL(-1) HCl+0.01molL(-1) thiourea) in case of Au(III), Pd(II), Pt(II) and Rh(III) and 10mL 0.5molL(-1) HNO(3) in case of Ag(I). Morin-APSG was successfully employed in the separation and preconcentration of the investigated precious metal ions from some spiking water samples yielding 100-folds concentration factor. The relative standard deviation (R.S.D.) and the T-test (|t|(1)) were calculated.  相似文献   

11.
A solid phase extraction method for simultaneous preconcentration and separation of trace amounts of copper, cobalt and silver in different samples, using a column packed with modified Amberlyst®15 resin is developed. Amberlyst®15 resin was modified with 5-(4-dimethylaminobenzylidene)rhodanine and then the modified resin was used as a support material for the solid phase extraction and preconcentration of Cu(II), Co(II) and Ag(I) ions from aqueous solution in the pH range 3.5–4.5. The adsorbed metal ions on the column were quantitatively eluted with a 7% thiourea solution prepared in 2?mol?L?1 HNO3, which were detected by flame atomic absorption spectrometry. The effects of analytical parameters including pH of the solution, eluent type, flow rate of samples, eluent and matrix ions were investigated for optimization of the presented procedure. The detection limits were 2.1, 0.9 and 0.9?ng?mL?1 for Cu(II), Co(II) and Ag(I) ions, respectively based on the three times the standard deviations of the blanks. The preconcentration factor was 112.5. The calibration graphs were obtained in the ranges of 0.05 to 10.0, 0.03 to 13.0 and 0.04 to 9.0?µg?mL?1 for Cu(II), Co(II) and Ag(I) ions concentrations, respectively. Relative standard deviations (n?=?7) for Cu(II), Co(II) and Ag(I) ions were found ±2.5 %, ±0.84% and ±3.8% respectively. The method was applied to the determination of mentioned ions in well water, waste water and lettuce sample.  相似文献   

12.
The silica gel with 1-(2-thiasolylazo)-2-naphthol adsorbed was obtained. The adsorption of Cu(II) and Zn(II) from an aqueous solution onto loaded silica gel was studied. The capabilities of 1-(2-thiasolylazo)-2-naphthol immobilized for Cu(II) and Zn(II) preconcentration, visual and diffusion reflectance spectroscopic detection was evaluated. The detection limits were 10 and 15 microg.l(-1), respectively. Visual test scales for metal ions determination in the range 0.65-13 microg per sample were worked out. The developed methods were applied to Cu(II) and Zn(II) determination in natural and tap water. The obtained results agreed well with the reported value.  相似文献   

13.
The use of the chemically modified silica gel N-(3-propyl)-O-phenylenediamine (SiG-NPPDA) adsorbent, for the preconcentration and separation of trace heavy metals, was described. SiG-NPPDA sorbs quantitatively (90-100% recovery) trace amounts of nine heavy metals, viz., Cd(II), Zn(II), Fe(III), Cu(II), Pb(II), Mn(II), Cr(III), Co(II) and Ni(II) at pH 7-8. The sorption capacity varies from 350 to 450 micromol g(-1). Desorption was found to be quantitative with 1-2 M HNO3 or 0.05 M Na2EDTA. The distribution coefficient, Kd and the percentage concentration of the investigated metal ions on the adsorbent at equilibrium, C(M,eqm)% (Recovery, R%), were studied as a function of experimental parameters. The logarithmic values of the distribution coefficient, log Kd, ranges between 4.0 and 6.4. Some foreign ions caused little interference in the preconcentration and determination of the investigated nine metals by flame atomic absorption spectrometry (AAS). The adsorbent and its formed metal chelates were characterized by IR (absorbance and/or reflectance), potentiometric titrations and thermogravimetric analysis (TGA and DTG). The mode of chelation between the SiG-NPPDA adsorbent and the investigated metal ions is proposed to be due to the reaction of the investigated metal ions with the two nitrogen atoms of the SiG-NPPDA adsorbent. The present adsorbent coupled with flame AAS has been used to enrich and determine the nine metal ions in natural aqueous systems and in certified reference materials (RSD < or = 5%). The copper, iron, manganese and zinc present in some pharmaceutical vitamin samples were also preconcentrated on SiG-NPPDA adsorbent and determined by flame AAS (RSD < or = 4.2%). Nanogram concentrations (0.07-0.14 ng ml(-1)) of Cd(II), Zn(II), Fe(III), Pb(II), Cr(III), Mn(II), Cu(II), Co(II) and Ni(II) can be determined reliably with a preconcentration factor of 100.  相似文献   

14.
Two new 4-aminoantipyrene chemically-immobilized silica gel phases: ii (N,N-donor) and iii (N,O-donor), were synthesized and characterized by IR and surface coverage determination. The latter was accomplished by thermal desorption and metal probe methods, giving 0.300 and 0.312 mmol g(-1) for ii and 0.220 and 0.250 mmol g(-1) for iii. Moreover, potentiometric titration provided a surface coverage of 0.323 mmol g(-1) for ii. The metal capacity values in mmol g(-1) of ii, iii and the active silica gel phase i for a series of di- and trivalent metal ions were determined at pH 1.0 - 6.7. Phase i showed the lowest values, while ii and iii reflected higher affinity toward most of the metal ions. The highest values were 0.300 for Hg(II)-ii and 0.220 mmol g(-1) for Cd(II)-iii. Distribution coefficients (log Kd) were in the range of 3.57 - 4.76 for ii and 2.32 - 3.46 for iii, thus confirming certain selectivity characters of the solid extractors. The application of the phases as solid extractors and preconcentrators for some heavy metal ions is presented. Good percentage extraction and removal of 94 - 98 +/- 4 - 6% of the spiked 1.000 microg ml(-1) of Hg(II), Cd(II), Pb(II), Cu(II) and Zn(II) and good percentage recovery of 94 - 99 +/- 3 - 6% of 50 ng ml(-1) of these ions from tap water samples were obtained. Stability constants of H(I) and Cu(II) with ii for the two-phase mixture at 25 degrees C and I = 0.1 (KCI) were determined potentiometrically. The pKa of ii are 5.6 and 8.4, while the log K values for CuHL and CuL (L = ii) are 6.3 and 5.8, respectively, leading to the determination of several analytical data for Cu(II)-ii.  相似文献   

15.
A new polychelatogen, AXAD-16-1,2-diphenylethanolamine, was developed by chemically modifying Amberlite XAD-16 with 1,2-diphenylethanolamine to produce an effective metal-chelating functionality for the preconcentration of Mn(II), Ni(II), Cu(II), Zn(II), Cd(II), and Pb(II) and their determination by flame atomic absorption spectrometry. Various physiochemical parameters that influence the quantitative preconcentration and recovery of metal were optimized by both static and dynamic techniques. The resin showed superior extraction efficiency with high-metal loading capacity values of 0.73, 0.80, 0.77, 0.87, 0.74, and 0.81 mmol/g for Mn(II), Ni(II), Cu(II), Zn(II), Cd(II), and Pb(II), respectively. The system also showed rapid metal-ion extraction and stripping, with complete saturation in the sorbent phase within 15 min for all the metal ions. The optimum condition for effective metal-ion extraction was found to be a neutral pH, which is a great advantage in the preconcentration of trace metal ions from natural water samples without any chemical pretreatment of the sample. The resin also demonstrated exclusive ion selectivity toward targeted metal ions by showing greater resistivity to various complexing species and more common metal ions during analyte concentration, which ultimately led to high preconcentration factors of 700 for Cu(II); 600 for Mn(II), Ni(II), and Zn(II); and 500 for Cd(II) and Pb(II), arising from a larger sample breakthrough volume. The lower limits of metal-ion detection were 7 ng/mL for Mn(II) and Ni(II); 5 ng/mL for Cu(II), Zn(II), and Cd(II), and 10 ng/mL for Pb(II). The developed resin was successful in preconcentrating metal ions from synthetic and real water samples, multivitamin-multimineral tablets, and curry leaves (Murraya koenigii) with relative standard deviations of < or = 3.0% for all analytical measurements, which demonstrated its practical utility.  相似文献   

16.
This work assesses the use of modified natural natrolite zeolite as an adsorptive material for the separation and preconcentration of trace amounts of ions. In this work we investigated the potential of modified natural natrolite zeolite for the simultaneous separation and preconcentration of trace amounts of copper and zinc ions. We have developed a simple, rapid, selective, sensitive and economical method for the simultaneous separation and preconcentration of trace amounts of copper and zinc in an aqueous medium using 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP) as an analytical reagent. The sorption was quantitative in the pH range 7.5 - 9.5, whereas quantitative desorption occurred instantaneously with 5.0 mL of 2 mol L(-1) nitric acid. Linearity was maintained between 0.05 - 6.0 microg mL(-1) for copper and 0.02 - 1.5 microg mL(-1) for zinc in the final solution. Ten replicate determinations of 1.0 microg mL(-1) copper and 0.5 microg mL(-1) zinc in a mixture gave mean absorbances of 0.1687 and 0.2788 with relative standard deviations of +/-1.2% and +/-1.3%, respectively. The detection limits were 0.03 ng mL(-1) for Cu(II) and 0.006 ng mL(-1) for Zn(II) in the original solution (3 sigma(bl)/m). Different parameters, such as the effect of the pH, flow rate, breakthrough volume and interference of a large number of anions and cations, were studied and the proposed method was used for the determination of these metal ions in water as well as standard samples (e.g. Nippon Keikinzoku Kogyo (NKK) CRM, No. 916 and No. 920 aluminum alloy, National Institute for Environment Studies (NIES) No. 1 pepperbush and NIES No. 2 pond sediment). The determination of these metal ions in standard samples showed that the proposed method has good accuracy (recovery > 97%).  相似文献   

17.
Gong B 《Talanta》2002,57(1):89-95
A novel polyacrylaminoimidazole chelating fiber is synthesized simply and rapidly from nitrilon (an acrylonitrile-based synthetic fiber) and used for the preconcentration and separation of trace Au(III), Hg(II) and Pd(IV) ions from solution samples. The analyzed ions can be quantitatively concentrated by the fiber up to a flow rate of 15.0 mlmin(-1) at pH 3 and can also be desorbed with 15 ml of 4 M HCl+3% thiourea from the fiber column, with recoveries of 96.5-100%. The chelating fiber is reused ten times; the recoveries of these ions are still over 92%, and 100-1000 times of excess of Fe(III), Al(III), Ca(II), Mg(II), Ni(II), Mn(II), Cu(II), Zn(II) and Cd(II) causes no interference in the determination of these ions by inductively coupled plasma atomic emission spectrometry. The capacities of the fiber for the analytes are in the range of 1.56-2.92 mmolg(-1). The results show that the relative standard deviations for the determination of 50.0 ngml(-1) each of Au(III), Hg(IV) and Pd(IV) are in the range of 0.7-2.1%. The recoveries of a standard added in real solution samples are between 97 and 99%, and the concentration of each ion in powder sample detected by the method is in good agreement with the certified value.  相似文献   

18.
In this work,we reported a simultaneous determination approach for Pb(II),Cd(II)and Zn(II)atμg L 1concentration levels using differential pulse stripping voltammetry on a bismuth film electrode(BiFE).The BiFE could be prepared in situ when the sample solution contained a suitable amount of Bi(NO)3,and its analytical performance was evaluated for the simultaneous determination of Pb(II),Cd(II)and Zn(II)in solutions.The determination limits were found to be 0.19μg L 1for Zn(II),and0.28μg L 1for Pb(II)and Cd(II),with a preconcentration time of 300 s.The BiFE approach was successfully applied to determine Pb(II),Cd(II)and Zn(II)in tea leaf and infusion samples,and the results were in agreement with those obtained using an atomic absorption spectrometry approach.Without Hg usage,the in situ preparation for BiFE supplied a green and acceptability sensitive method for the determination of the heavy metal ions.  相似文献   

19.
Duolite GT-73 resin was used for the preconcentration of Hg(II) from hydrochloric acid media as well as separation of the analyte from diversity of the co-existing metal ions (Al, Ca, Cd, Co, Cr, Cu, Fe, Mg, Mn, Ni, Pb and Zn) in off-line column operation. Due to the high affinity of the resin to the transition metals, Hg was adsorbed alongside with the foreign metals investigated. A complete release of the concomitant metals from the resin without the desorption of Hg was carried out using solutions of HCl and HNO3. A quantitative recovery of Hg was obtained by digestion of the resin using a H2SO4 and H2O2 mixture in an open-vessel system. An enrichment factor of 40 was achieved. The devised procedure was applied for the determination of Hg(II) in tap-water samples.  相似文献   

20.
Extractive separation, preconcentration, and determination of gold as an ion associate (IA) with 2-[2-(4-methoxyphenylamino)vinyl]-1,3,3-trimethyl-3H-indolium chloride in extracts by spectrophotometry and atomic absorption spectrometry were studied. The optimal conditions were found for the extraction of IA with aromatic hydrocarbons and acetate esters. The main chemical analytical properties of the ion associate were determined. The formation of IA enables extractive separation of gold from Al, Cr, Mn, Fe, Co, Ni, Zn, Cu, Cd, Pt, Hg, Bi, Ag, Pb, and Pd. By varying the volume ratio of the aqueous and organic phases in the range of (1–40): 1, one can combine extractive separation and the preconcentration of gold and decrease the detection limit for gold to 0.031 mg/L (extraction-spectrophotometric determination) or 0.084 μg/L (direct determination in extracts by electrothermal atomic absorption spectrometry). Procedures were developed for the determination of trace amounts of gold, and their performance characteristics were calculated.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号