首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 328 毫秒
1.
A bootstrapped fuzzy rule-building expert system (FuRES) and a bootstrapped t-statistical weight feature selection method were individually used to select informative features from gas chromatography/mass spectrometry (GC/MS) chemical profiles of basil plants cultivated by organic and conventional farming practices. Feature subsets were selected from two-way GC/MS data objects, total ion chromatograms, and total mass spectra, separately. Four economic classifiers based on the bootstrapped FuRES approach, i.e., fuzzy optimal associative memory (e-FOAM), e-FuRES, partial least-squares–discriminant analysis (e-PLS-DA), and soft independent modeling by class analogy (e-SIMCA), and four economic classifiers based on the bootstrapped t-weight approach, i.e., e-PLS-DA-t, e-FOAM-t, e-FuRES-t, and e-SIMCA-t, were constructed thereafter to be compared with full-size classifiers obtained from the entire GC/MS data objects (i.e., FOAM, FuRES, PLS-DA, and SIMCA). By using three features selected from two-way data objects, the average classification rates with e-FOAM, e-FuRES, e-PLS-DA, and e-SIMCA were 95.3?±?0.5 %, 100 %, 100 %, and 91.8?±?0.2 %, respectively. The established economic classifiers were used to classify a new validation set collected 2.5 months later with no parametric change to experimental procedure. Classification rates with e-FOAM, e-FuRES, e-PLS-DA, and e-SIMCA were 96.7 %, 100 %, 100 %, and 96.7 %, respectively. Characteristic components in basil extracts corresponding to highest-ranked useful features were putatively identified. The feature subset may prove valuable as a rapid approach for organic basil authentication.  相似文献   

2.
The purpose of this study is to determine whether gas chromatography (GC)-atomic emission detection (AED) can be used in a low-resolution mode for rapid, accurate determinations of total sulfur in fuels at trace levels to complement other popular methods of total sulfur analysis. A method for the rapid determination of total sulfur in fuels (called "fast GC-AED") is developed. The method is tested on gasoline, jet fuel, kerosene, and diesel fuel with sulfur concentrations ranging from 125 mg/L down to 2.5 mg/L. Fast GC-AED shows better performance than traditional GC-AED for total sulfur determinations, especially for complex mixtures containing many different sulfur-containing compounds at trace levels. This method also shows that GC-AED can be used for both rapid determinations of total sulfur and traditional determinations of speciated sulfur without requiring equipment changes. Fast GC-AED is competitive with other popular methods for sulfur analysis. The 5-min program that is developed for fast GC-AED is comparable with the time scale of other methods, such as wavelength dispersive X-ray fluorescence and UV-fluorescence (2 to 5 min). Fast GC-AED also compares favorably with UV-fluorescence for trace sulfur determinations, demonstrating accuracy down to 2.5-mg/L sulfur.  相似文献   

3.
There is a great demand for simple, fast and accurate methods for quantification of volatile organic contaminants in soil samples. Solid-phase microextraction (SPME) has a huge potential for this purpose, but its application is limited by insufficient accuracy caused by a matrix effect. The aim of this research was to develop the method for BTEX quantification in soil using combined standard addition (SA) and internal standard (IS) calibration. Deuterated benzene (benzene-d6) was used as the internal standard for all analytes. The optimized method includes spiking replicate samples with different concentrations of BTEX standards and the same concentration of benzene-d6, equilibration of soil samples at 40 °C during 2 h, and SPME–GC–MS analysis. Precision and accuracy of IS and SA methods were compared on different soil matrices. Combined SA + IS method provided more precise calibration plots compared to the conventional SA calibration. The SA + IS calibration provided more precise and accurate results compared with a reference method based on solvent extraction followed by GC–MS when applied to BTEX quantification in real soil samples (spiked with diesel fuel and aged). Recoveries of BTEX from soil samples spiked with known concentrations of analytes using the developed method were in the range of 73–130% with RSD values less than 15% for all BTEX. The proposed simultaneous standard addition and internal standard approach can be advantageous and adopted for improved quantification of other toxic VOCs in soil.  相似文献   

4.
A bootstrap method for point-based detection of candidate biomarker peaks has been developed from pattern classifiers. Point-based detection methods are advantageous in comparison to peak-based methods. Peak determination and selection are problematic when spectral peaks are not baseline resolved or on a varying baseline. The benefit of point-based detection is that peaks can be globally determined from the characteristic features of the entire data set (i.e., subsets of candidate points) as opposed to the traditional method of selecting peaks from individual spectra and then combining the peak list into a data set. The point-based method is demonstrated to be more effective and efficient using a synthetic data set when compared to using Mahalanobis distance for feature selection. In addition, probabilities that characterize the uniqueness of the peaks are determined.This method was applied for detecting peaks that characterize age-specific patterns of protein expression of developing and adult mouse cerebella from matrix assisted laser desorption/ionization (MALDI) mass spectrometry (MS) data. The mice comprised three age groups: 42 adults, 19 14-day-old pups, and 16 7-day-old pups. Three sequential spectra were obtained from each tissue section to yield 126, 57 and 48 spectra for adult, 14-day-old pup, and 7-day-old pup spectra, respectively. Each spectrum comprised 71,879 mass measurements in a range of 3.5-50 kDa. A previous study revealed that 846 unique peaks were detected that were consistent for 50% of the mice in each age group (C. Laurent, D.F. Levinson, S.A. Schwartz, P.B. Harrington, S.P. Markey, R.M. Caprioli, P. Levitt, Direct profiling of the cerebellum by MALDI MS: a methodological study in postnatal and adult mouse, J. Neurosci. Res. 81 (2005) 613-621.).A fuzzy rule-building expert system (FuRES) was applied to investigate the correlation of age with features in the MS data. FuRES detected two outlier pup-14 spectra. Prediction was evaluated using 100 bootstrap samples of 2 Latin-partitions (i.e., 50:50 split between training and prediction set) of the mice. The spectra without the outliers yielded classification rates of 99.1 ± 0.1%, 90.1 ± 0.8%, and 97.0 ± 0.6% for adults, 14-day-old pups, and 7-day-old pups, respectively. At a 95% level of significance, 100 bootstrap samples disclosed 35 adult and 21 pup distinguishing peaks for separating adults from pups; and 8 14-day-old and 15 7-day-old predictive peaks for separating 14-day-old pup from 7-day-old pup spectra. A compressed matrix comprising 40,393 points that were outside the 95% confidence intervals of one of the two FuRES discriminants was evaluated and the classification improved significantly for all classes. When peaks that satisfied a quality criterion were integrated, the 55 integrated peak areas furnished significantly improved classification for all classes: the selected peak areas furnished classification rates of 100%, 97.3 ± 0.6%, and 97.4 ± 0.3% for adult, 14-day-old pups, and 7-day-old pups using 100 bootstrap Latin partitions evaluations with the predictions averaged. When the bootstrap size was increased to 1000 samples, the results were not significantly affected. The FuRES predictions were consistent with those obtained by discriminant partial least squares (DPLS) classifications.  相似文献   

5.
Comprehensive, two-dimensional gas chromatography (GC x GC) is used in conjunction with trilinear partial least squares (Tri-PLS) to quantify the percent weight of naphthalenes (two-ring aromatic compounds) in jet fuel samples. The increased peak capacity and selectivity of GC x GC makes the technique attractive for the rapid, and possibly less tedious analysis of jet fuel. The analysis of complex mixtures by GC x GC is further enhanced through the use of chemometric techniques, including those designed for use on 2-D data such as Tri-PLS. Unfortunately, retention time variation, unless corrected, can be an impediment to chemometric analysis. Previous work has demonstrated that the effects of retention time variation can be mitigated in sub-regions of GC x GC chromatograms through the application of an objective retention time alignment algorithm based on rank minimization. Building upon this previous work, it is demonstrated here that the effects of retention time variation can be mitigated throughout an entire GC x GC chromatogram with an objective retention time alignment algorithm based on windowed rank minimization alignment. A significant decrease in calibration error is observed when the algorithm is applied to chromatograms prior to construction of Tri-PLS models. Fourteen jet fuel samples with known weight percentages of naphthalenes (ASTM D1840) were obtained. Each sample was subjected to five replicate five-minute GC x GC separations over a period of two days. A subset of nine samples spanning the range of weight percentages of naphthalenes was chosen as a calibration set and Tri-PLS calibration models were subsequently developed in order to predict the naphthalene content of the samples from the GC x GC chromatograms of the remaining five samples. Calibration models constructed from GC x GC chromatograms that were retention time corrected are shown to exhibit a root mean square error of prediction of roughly half that of calibration models constructed from uncorrected chromatograms. The error of prediction is lowered further to a value that nearly matches the uncertainty in the standard percent weight values (ca. 1% of the median percent volume value) when the aligned chromatograms are truncated to include only regions of the chromatogram populated by naphthalenes and compounds of similar polarity and boiling point.  相似文献   

6.
Qiu Y  Lu X  Pang T  Ma C  Li X  Xu G 《Journal of separation science》2008,31(19):3451-3457
Comprehensive 2-D GC (GC x GC) coupled with TOF MS or flame ionization detector (FID) was employed to characterize and quantify the chemical composition of volatile oil in the radixes of Panax ginseng C. A. Mey. (ginseng) at different ages. Thirty-six terpenoids were tentatively identified based on the MS library search and retention index in a ginseng sample at the age of 3 years. An obvious group-type separation was obtained in the GC x GC-TOF MS chromatogram. The data collected by GC x GC-FID were processed using a principal component analysis (PCA) method to classify the samples at different ages. The compounds responsible for the significant differentiation among samples were defined. It was found that the relative abundances of alpha-cadinol, alpha-bisabolol, thujopsene, and n-hexadecanoic acid significantly rise with the increase in age.  相似文献   

7.
Fully synthetic jet fuel (FSJF) produced via Fischer-Tropsch (FT) technology was recently approved by the international aviation fuel authorities. To receive approval, comparison of FSJF and crude-derived fuel and blends on their qualitative and quantitative hydrocarbon composition was of utmost importance. This was performed by comprehensive two-dimensional gas chromatography (GC×GC) in the reversed phase mode. The hydrocarbon composition of synthetic and crude-derived jet fuels is very similar and all compounds detected in the synthetic product are also present in crude-derived fuels. Quantitatively, the synthetic fuel consists of a higher degree of aliphatic branching with less than half the aromatic content of the crude-derived fuel. GC×GC analyses also indicated the presence of trace levels of hetero-atomic impurities in the crude-derived product that were absent in the synthetic product. While clay-treatment removed some of the impurities and improved the fuel stability, the crude-derived product still contained traces of cyclic and aromatic S-containing compounds afterwards. Lower level of aromatics and the absence of sulphur are some of the factors that contribute to the better fuel stability and environmental properties of the synthetic fuel. GC×GC was further applied for the analysis of products during Jet Fuel Thermal Oxidation Testing (JFTOT), which measures deposit formation of a fuel under simulated engine conditions. JFTOT showed the synthetic fuel to be much more stable than the crude-derived fuel.  相似文献   

8.
This work presents the potential application of organic-resistant screen-printed graphitic electrodes (SPGEs) for fuel analysis. The required analysis of the antioxidant 2,6-di-tert-butylphenol (2,6-DTBP) in biodiesel and jet fuel is demonstrated as a proof-of-concept. The screen-printing of graphite, Ag/AgCl and insulator inks on a polyester substrate (250 μm thickness) resulted in SPGEs highly compatible with liquid fuels. SPGEs were placed on a batch-injection analysis (BIA) cell, which was filled with a hydroethanolic solution containing 99% v/v ethanol and 0.1 mol L−1 HClO4 (electrolyte). An electronic micropipette was connected to the cell to perform injections (100 μL) of sample or standard solutions. Over 200 injections can be injected continuously without replacing electrolyte and SPGE strip. Amperometric detection (+1.1 V vs. Ag/AgCl) of 2,6-DTBP provided fast (around 8 s) and precise (RSD = 0.7%, n = 12) determinations using an external calibration curve. The method was applied for the analysis of biodiesel and aviation jet fuel samples and comparable results with liquid and gas chromatographic analyses, typically required for biodiesel and jet fuel samples, were obtained. Hence, these SPGE strips are completely compatible with organic samples and their combination with the BIA cell shows great promise for routine and portable analysis of fuels and other organic liquid samples without requiring sophisticated sample treatments.  相似文献   

9.
A fast and environment-friendly analytical method was implemented to determine multiclass pesticides in river sediments. Twenty-three pesticides—organochlorine pesticides, organophosphorus pesticides, and triazines—were extracted via matrix solid-phase dispersion (MSPD) and analyzed by gas chromatography–tandem mass spectrometry (GC–MS/MS). Florisil demonstrated excellent analytes uptake capability as the extractant phase, with suitable selectivity for treating complex sediment samples. Under defined extraction conditions, the MSPD–GC–MS/MS method demonstrated robustness in the n inter-day analysis of sediments from different sources, providing limit of quantifications (LOQs) between 5 and 15 ng/g, linear responses in the range between LOQs and 150 ng/g, extraction recoveries of 71%–106%, and precision, assessed as relative standard deviation below 20%. The MSPD significantly reduced samples and solvents’ consumption, providing critical environmental gains compared to traditional extraction methods like Soxhlet. Finally, the method was applied to analyze sediment samples from three different collection areas of the Subachoque River (Cundinamarca, Colombia), demonstrating a fast, efficient, confident, and profitable analytical tool for pollution control and monitoring in environmental samples. The method allowed us to determine the current use in Colombia of banned pesticides under the 2001 Stockholm Convention.  相似文献   

10.
Boyong Wan 《Analytical letters》2019,52(14):2251-2265
Wavelet analysis was evaluated as a data preprocessing tool in the construction of automated classifiers for the detection of volatile organic compounds from passive Fourier transform infrared remote sensing data collected in a downward-looking mode from an aircraft platform. The discrete wavelet transform was applied to single-beam spectra and patterns were formed with either the wavelet coefficients directly or with spectra reconstructed with selected resolution levels of the wavelet decomposition. Automated classifiers were constructed with support vector machines (SVM) and used to detect releases of methanol from an industrial site. A key issue in this work was the desire to use data collected during controlled experiments on the ground to train the SVM classifiers. Spectral backgrounds in these ground-collected data are different than those encountered as the aircraft flies, however, and the development of successful classification models requires spectral preprocessing to suppress background signatures. Biorthogonal wavelets were used to generate patterns and resulted in SVM models that produced no missed methanol detections and false detection rates of less than 0.1% when applied to prediction data not used in the development of the model. The SVM classifiers constructed with wavelet processing were compared to one based on unprocessed spectra and also to one computed with spectra preprocessed with Butterworth high-pass digital filters.  相似文献   

11.
The aim of the present study was to set‐up a Fast gas chromatography/mass spectrometry method for the analysis of cholesterol oxidation products (COPs). A silylated mixture of seven oxysterol standards was injected into a Fast GC/MS system. A capillary GC column (10 m×0.1 mm internal diameter×0.1 μm film thickness) coated with 95% dimethyl‐ and 5% diphenyl‐polysiloxane, was used. The method gave a fast (total analysis time=3.5 min) and satisfactory resolution (R>1.2) of the COPs standards, with a good repeatability and sensitivity, similar to those of conventional GC/MS; recoveries were tested on mice liver. Fast GC/MS method suitability for COPs analysis in food was also tested on an oxidized sardine fillet, which had been previously saponified and purified by NH2 solid‐phase extraction (SPE); a good repeatability and sensitivity was also obtained. The analytical performance of the Fast GC/MS method for the determination of COPs, together with the consequent significant reduction of the analysis time and consumables, demonstrates that Fast GC/MS represents a valid alternative to conventional GC/MS and evinces the great potential of such an analytical technique, which could be applied for both food and biological samples.  相似文献   

12.
The aim of this study was to develop and validate fast and easily applicable GC/MS assay for the quantification of the substance that increases cetane number in diesel fuel (2-ethylhexylnitrate, 2-EHN). These requirements were fulfilled best by a headspace GC-MS assay with negative chemical ionization with methane (HS-GC/MS). Chromatographic separation is achieved using a DB5-MS capillary column after the addition of known amount of internal standard (o-nitrotoluene). The limit of detection was 0.009% v/v for 2-EHN and the limit of quantification was 0.03% v/v. The HS-GC/MS method was applied for the quantification of cetane improver in spiked diesel fuel and real diesel fuel. The method is linear over the studied range (0.03-0.3%, v/v), with satisfactory intra- and inter-assay precision, and the relative standard deviations are lower than 10%. Good accuracy is achieved with bias <10% at all levels tested.  相似文献   

13.
Correct prediction of the fission products inventory in irradiated nuclear fuels is essential for accurate estimation of fuel burnup, establishing proper requirements for spent fuel transportation and storage, materials accountability and nuclear forensics. Such prediction is impossible without accurate knowledge of neutron induced fission yields. The uncertainty of the fission yields reported in the ENDF/B-VII.0 library is not uniform across all of the data and much of the improvement is desired for certain fissioning isotopes and fission products. We discuss our measurements of cumulative fission yields in nuclear fuels irradiated in thermal and fast reactor spectra using Inductively Coupled Plasma Mass Spectrometry.  相似文献   

14.
This study describes the use of spectral fingerprints acquired by flow injection(FI)-MS and multivariate analysis to differentiate three Panax species: P. ginseng, P. quinquefolius, and P. notoginseng. Data were acquired using both high resolution and unit resolution MS, and were processed using principal component analysis (PCA), soft independent modeling of class analogy (SIMCA), partial least squares-discriminant analysis (PLS-DA), and a fuzzy rule-building expert system (FuRES). Both high and unit resolution MS allowed discrimination among the three Panax species. PLS-DA and FuRES provided classification with 100% accuracy while SIMCA provided classification accuracies of 77 and 88% by high- and low-resolution MS, respectively. The method does not quantify any of the sample components. With FI-MS, the analysis time was less than 2 min.  相似文献   

15.
A method for fast determination of the component in complex samples by using gas chromatography‐mass spectrometry (GC‐MS) was developed and used for quantitative analysis of phenanthrene in soils. In the method, window independent component analysis (WICA) was used for resolving the mass spectrum and non‐negative immune algorithm (NNIA) was employed for obtaining the chromatographic profile. Therefore, spectral and chromatographic information of a specific component can be obtained from the measured GC‐MS data of overlapping and high background. Six soil samples collected from different places were analyzed. The tedious pretreatments in preparing the samples and the elution in the separation were simplified for speeding up the analysis. Due to the complexity of the matrix, standard addition method was adopted for the final quantification. The applicability of the method was validated with a spiked sample and the results of the six samples are reasonable.  相似文献   

16.
Keshet  Uri  Fialkov  Alexander B.  Alon  Tal  Amirav  Aviv 《Chromatographia》2016,79(11):741-754

We designed and operated a new system of pulsed flow modulation (PFM) two dimensional comprehensive gas chromatography (GC × GC) mass spectrometry (MS). This system is based on the combination of PFM–GC × GC with a quadrupole mass spectrometer of GC–MS via a supersonic molecular beams interface and its fly-through Cold EI ion source and applied this system for the analysis of JP8 jet fuel. PFM is a simple GC × GC modulator that does not consume cryogenic gases while providing tunable second GC × GC column injection time for enabling the use of quadrupole based mass spectrometry regardless its limited scanning speed. We analyzed JP8 jet fuel with our new PFM–GC × GC–MS with Cold EI system and found that as the second dimension GC elution time is increased the observed molecular ion mass is reduced. This unique observation that helped in improved sample compounds identification under co-elution conditions was enabled via having abundant molecular ions in Cold EI for all the fuel compounds. We named this type of analysis as PFM–GC × GC × MS. We found and discuss in this paper that PFM–GC × GC–MS with Cold EI combines improved separation of GC × GC with Cold EI benefits of tailing-free ultra-fast ion source response time and enhanced molecular ions and mass spectral isomer and isotope information for the provision of increased sample identification information.

  相似文献   

17.
利用气相色谱-飞行时间质谱,对安息香膏的挥发性成分进行分析,并用峰面积归一化法计算各成分相对含量。利用在两种不同极性色谱柱上的比较试验,确定了适合安息香膏分析的色谱柱条件。在最适合安息香膏分离的色谱条件下对4种不同批次安息香膏的微差样品进行分析。通过质谱库检索,辅助英文版精油库(ES02006版)比对,解析并确定出精油中的24种组分,主要成分是苯甲酸苄酯(25.52%)、苯甲酸(23.12%)、乙基香兰素(14.93%)、苯甲醇(14.50%)、肉桂酸肉桂酯(13.41%)、肉桂酸苄酯(7.54%)等。用主成分投影分析法对4种微差样品进行分类区分,结果证明,用主成分分析法辅助GC—TOF/MS能较快速准确地对微差样品进行区分。该方法可用于安息香膏的产品开发及其品质控书1。  相似文献   

18.
A method for the fast analysis of a specific component in complex samples by GC–MS was developed and used for the quantitative determination of prometryn in hair samples. In this method, the tedious and time‐consuming sample pretreatment for purification was avoided, and a short capillary column and fast temperature program were employed to speed up the analysis. Although the measured total ion chromatogram is composed of overlapping peaks with interference and background noise, the signal of prometryn can be extracted by chemometric methods. Window‐independent component analysis was used to extract the mass spectrum and a non‐negative immune algorithm was employed to obtain the chromatographic profile of the interesting component from the measured data. Due to the complexity of the matrix, a standard addition method was adopted for the quantification. The applicability of the method was validated with spiked samples, and the recoveries were in the range of 99–105%.  相似文献   

19.
A simple, rapid, and reliable liquid–liquid extraction coupled to GC–MS method was developed and validated for the quantification of 22 phthalate esters (PAEs) in honey and royal jelly. Instrument parameters for GC–MS were tested to obtain the satisfactory separation between 22 PAEs with high sensitivity. The extraction procedure was optimized in order to achieve the best recovery. The following criteria were used to validate the developed method: linearity, LOD, lower LOQ, precision, accuracy, matrix effect and carry‐over. Correlation coefficients were >0.999 by applying the linear regression model based on the least‐squares method with a weighting factor (1/x). The intra‐ and interday precision were within 12.7% in terms of RSD, and the accuracy was within ?11.8% in terms of relative error. The mean extraction recoveries ranged between 80.1 and 110.9% for honey and royal jelly. No significant matrix effect and carry‐over for PAEs were observed for the analysis of honey and royal jelly samples. A total of 20 real samples were analyzed for a mini‐survey using the developed method. Seven PAEs in honey samples and five PAEs in royal jelly samples were found, indicating potential contamination with several PAEs.  相似文献   

20.
Polycyclic aromatic hydrocarbons (PAHs) are frequently measured in the atmosphere for air quality assessment, in biological tissues for health-effects monitoring, in sediments and mollusks for environmental monitoring, and in foodstuffs for safety reasons. In contemporary analysis of these complex matrices, gas chromatography (GC), rather than liquid chromatography (LC), is often the preferred approach for separation, identification, and quantification of PAHs, largely because GC generally affords greater selectivity, resolution, and sensitivity than LC. This article reviews modern-day GC and state-of-the-art GC techniques used for the determination of PAHs in environmental samples. Standard test methods are discussed. GC separations of PAHs on a variety of capillary columns are examined, and the properties and uses of selected mass spectrometric (MS) techniques are presented. PAH literature on GC with MS techniques, including chemical ionization, ion-trap MS, time-of-flight MS (TOF-MS), and isotope-ratio mass spectrometry (IRMS), is reviewed. Enhancements to GC, for example large-volume injection, thermal desorption, fast GC, and coupling of GC to LC, are also discussed with regard to the determination of PAHs in an effort to demonstrate the vigor and robustness GC continues to achieve in the analytical sciences.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号