首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Dol I  Knochen M 《Talanta》2004,64(5):1233-1236
A flow-injection method is proposed for the determination of salbutamol. The method involves the condensation of salbutamol with 4-aminoantipyrine in the presence of hexacyanoferrate (III) in alkaline medium, producing a coloured quinoneimide that was detected absorptiometrically at 500 nm.

The values of four variables (two reactor lengths and two reagent concentrations) were optimised by means of the sequential simplex method and their influence studied in univariant way.

The method was validated and compared with the HPLC method established in the United States Pharmacopeia (USP). Linearity was demonstrated in the range 0–74.1 mg/L of salbutamol sulfate (r2 = 0.9999). Commercial samples of pharmaceuticals containing salbutamol sulfate (tablets and oral solutions) were analysed and the results obtained with the proposed method agreed with the USP method in less than 1.6%, with precision similar to the HPLC method (1%–2% R.S.D.). The sampling frequency was 75 samples/hour.  相似文献   


2.
基于沙拉沙星对Ag(III)络合物-H2SO4体系化学发光信号的增敏作用,提出了一种流动注射-化学发光测定沙拉沙星的新方法。考察和优化了影响化学发光强度的条件。沙拉沙星在2.0×10-7~1.0×10-5g/mL范围内,其校准曲线具有良好的线性。方法的检出限为1.2×10-7g/mL,相对标准偏差0.5%~1.2%。该方法已用于沙拉沙星兽药制剂的质量检测,回收率为83.3%~96.3%。通过比较其荧光光谱和化学发光光谱,讨论了该体系的化学发光机理。  相似文献   

3.
Khaled E 《Talanta》2008,75(5):1167-1174
A simple, rapid and accurate method for the spectrophotometric determination of terfenadine has been developed. The proposed method based on the charge-transfer reactions of terfenadine, as n-electron donor, with 7,7,8,8-tetracyanoquinodimethane (TCNQ), tetracyanoethylene (TCNE), 2,3-dichloro-5,6-dicyano-1,4-benzoquinone (DDQ) or 2,5-dichloro-3,6-dihydroxy-1,4-benzoquinone (chloranilic acid, p-CLA) as π-acceptors to give highly colored complexes. The experimental conditions such as reagent concentration, reaction solvent and time have been carefully optimized to achieve the highest sensitivity. Beer's law is obeyed over the concentration ranges of 3–72, 3–96, 12–168 and 24–240 μg mL−1 terfenadine using TCNQ, TCNE, DDQ and p-CLA, respectively, with correlation coefficients 0.9999, 0.9974, 0.9997 and 0.9979 and detection limits 0.3, 0.4, 2.6 and 12.3 μg mL−1, for the reagents in the same order. DDQ and p-CLA react spontaneously with terfenadine to give colored complexes that can be applied for the flow injection analysis of terfenadine in the concentration ranges 2.4–120 and 24–240 μg with correlation coefficients 0.9990 and 0.9985 and detection limits 0.8 and 2.7 μg for DDQ and p-CLA, respectively, in addition to the high sampling through output of 40 sample h−1.  相似文献   

4.
A flow-injection system for detection of alkaline phosphatase (ALP) activity in human serum samples has been developed. As a specific and inexpensive ALP substrate for this kinetic assay monofluorophosphate (MFP) was applied. For detection of fluoride ions, generated in the course of the biocatalytic hydrolysis of MFP, conventional fluoride ion-selective electrode based on LaF3-crystalline membrane was applied. After optimization the system allows analysis of human serum with high selectivity and relatively short time of analysis (5–6 samples h−1). Volume of serum required for analysis is 0.05 mL. The system is useful for determination of the enzyme activity in human serum samples at physiological and pathological levels as well as for detection of isoenzymatic forms of ALP.  相似文献   

5.
Abbas MN  Radwan AA 《Talanta》2008,74(5):1113-1121
A potentiometric lipoate-selective sensor based on mercuric lipoate ion-pair as a membrane carrier is reported. The electrode was prepared by coating the membrane solution containing PVC, plasticizer, and carrier on the surface of graphite electrode. Influences of the membrane composition, pH, and possible interfering anions were investigated on the response properties of the electrode. The sensor exhibits significantly enhanced response toward lipoate ions over the concentration range 1 × 10−7 mol L−1 to 1 × 10−2 mol L−1 with a lower detection limit of (LDL) of 9 × 10−8 mol L−1 and a slope of −29.4 mV decade−1, with S.D. of the slope is 0.214 mV. Fast and stable response, good reproducibility, long-term stability, applicability over a pH range of 8.0–9.5 is demonstrated. The sensor has a response time of ≤12 s and can be used for at least 6 weeks without any considerable divergence in its potential response. The proposed electrode shows good discrimination of lipoate from several inorganic and organic anions. The CGE was used in flow injection potentiometry (FIP) and resulted in well defined peaks for lipoate ions with stable baseline, excellent reproducibility and reasonable sampling rate of 30 injections per hour. The proposed sensor has been applied for the direct and FI potentiometric determination of LA in pharmaceutical preparations and urine; and has been also utilized as an indicator electrode for the potentiometric titration of LA.  相似文献   

6.
An automatic flow-injection (FI) system including on-line separation by microdistillation and spectrophotometric detection has been developed for the determination of trace amounts of fluoride. This ion was separated from sample matrix by distillation in the presence of sulfuric and phosphoric acids, and was subsequently determined with spectrophotometry based on the mixed-ligand complex of lanthanum(III)-fluoride-alizarin complexone. The proposed FI system has high sampling frequency (20 samples h−1), small sample size (600 μl) and the dynamic range of 0.05-15 mg l−1 with relative standard deviations of below 1.2%. Interfering ions such as aluminum(III) and iron(III) was effectively eliminated. The method was successfully applied to the determination of fluoride in industrial drainage after water treatment.  相似文献   

7.
Melchert WR  Rocha FR 《Talanta》2005,65(2):461-465
Nitrate determination in waters is generally carried out with cadmium filings and carcinogenic reagents or by reaction with phenolic compounds in highly concentrated sulfuric acid medium. In this work, it was developed a green analytical procedure for nitrate determination in natural waters based on direct spectrophotometric measurements in ultraviolet, using a flow-injection system with an anion-exchange column for separation of nitrate from interfering species. The proposed method employs only one reagent (HClO4) in a minimum amount (equivalent to 18 μL concentrated acid per determination), and allowed nitrate determination within 0.50-25.0 mg L−1, without interference of up to 200.0 mg L−1 humic acid; 1.0 mg L−1 NO2; 200.0 mg L−1 PO43−; 75.0 mg L−1 Cl; 50.0 mg L−1 SO42− and 15.0 mg L−1 Fe3+. The detection limit (99.7% confidence level) and the coefficient of variation (n = 20) were estimated as 0.1 mg L−1 and 0.7%, respectively. The results obtained for natural water samples were in agreement with those achieved by the reference method based on nitrate reduction with copperized cadmium at the 95% confidence level.  相似文献   

8.
流动注射化学发光法测定盐酸羟苄唑   总被引:1,自引:0,他引:1  
基于在碱性条件下盐酸羟苄唑能够与鲁米诺产生化学发光的现象,建立了流动注射化学发光测定盐酸羟苄唑的新方法。盐酸羟苄唑的浓度在8×10-7~1×10-4mol/L范围内与化学发光强度呈良好的线性关系,方法的(3σ)检出限为3×10-7mol/L,对1×10-5mol/L的盐酸羟苄唑连续11次测定的相对标准偏差为1.7%,回收率为96%~103%。已用于滴眼液中盐酸羟苄唑的测定。  相似文献   

9.
Burakham R  Oshima M  Grudpan K  Motomizu S 《Talanta》2004,64(5):1259-1265
A novel spectrophotometric reaction system was developed for the determination of nitrite as well as nitrate in water samples, and was applied to a flow-injection analysis (FIA). The spectrophotometric flow-injection system coupled with a copperised cadmium reductor column was proposed. The detection was based on the nitrosation reaction between nitrite ion and phloroglucinol (1,3,5-trihydroxybenzene), a commercially available phenolic compound. Sample injected into a carrier stream was split into two streams at the Y-shaped connector. One of the streams merged directly and reacted with the reagent stream: nitrite ion in the samples was detected. The other stream was passed through the copperised cadmium reductor column, where the reduction of nitrate to nitrite occurred, and the sample zone was then mixed with the reagent stream and passed through the detector: the sum of nitrate and nitrite was detected. The optimised conditions allow a linear calibration range of 0.03–0.30 μg NO2-N ml−1 and 0.10–1.00 μg NO3-N ml−1. The detection limits for nitrite and nitrate, defined as three times the standard deviation of measured blanks are 2.9 ng NO2-N ml−1 and 2.3 ng NO3-N ml−1, respectively. Up to 20 samples can be analyzed per hour with a relative standard deviation of less than 1.5%. The proposed method could be applied successfully to the simultaneous determination of nitrite and nitrate in water samples.  相似文献   

10.
A simple, fast chemiluminescence (CL) flow-injection (FI) method based on the reaction of luminol with KMnO4 in alkaline medium has been described for the direct determination of carbofuran. The method is based on the enhancing effect in the emission light from the oxidation of luminol produced in presence of carbofuran. The optimisation of instrumental and chemical variables influencing the CL response of the method has been carried out by applying experimental design, using the proposed flow-injection manifold. Under the optimal conditions, the CL intensity was linear for a carbofuran concentration over the range of 0.06-0.5 μg ml−1, with a detection limit of 0.02 μg ml−1. The method has been successfully applied to the determination of carbofuran residues in spiked water and lettuce samples.  相似文献   

11.
Vanadium(V) is determined by a simple bead injection spectroscopy–flow-injection analysis (BIS–FIA) system with spectrofluorimetric detection using a commercially available flow cell (Hellma 176-QS). The 500 μl of a homogeneous bead suspension of an anionic resin (Sephadex QAE A-25) previously loaded with the fluorogenic reagent 1,2-dihydroxyanthraquinone-3-sulfonic acid (Alizarin Red S) was injected to fill the flow cell. Next, V(V) is injected into the carrier and reacts with the immobilized reagent on the active solid support placed in the flow cell to form a fluorescent chelate in the absence of surfactant agents. The complex is so strongly retained on the beads that the regeneration of the solid support becomes extraordinarily difficult, so needing the renovation of the sensing surface which is achieved by means of bead injection. At the end of the analysis, beads are automatically discarded from the flow cell and transported out of the system by reversing the flow.

The measurement of fluorescence is continuously performed at an excitation wavelength of 521 nm and an emission wavelength of 617 nm. Using a low sample volume of 800 μl, the analytical signal showed a very good linearity in the range 2–60 ng ml−1, with a detection limit of 0.45 ng ml−1 and a R.S.D. (%) of 4.22 for 50 ng ml−1 of V(V) concentration (n = 10). The sensor showed both a good selectivity, which could also be increased by the addition of EDTA and F as masking agents, and applicability to the determination of V(V) in waters, physiological samples (serum and urine) and mussel tissues.  相似文献   


12.
A simple, sensitive and specific flow-injection spectrofluorimetric method has been developed for the determination of folic acid in pharmaceuticals. The method is based on use of a lead dioxide solid-phase reactor for on-line oxidation of folic acid into a strongly fluorescent compound with a maximum excitation wavelength of 281 nm and an emission wavelength of 450 nm. Under optimum conditions the fluorescence intensity of oxidation product is proportional to the concentration of folic acid over the range 0.008–2.5 g mL–1. The detection limit is 0.0001 g mL–1, the relative standard deviation is 0.85% for 11 replicate determinations of 0.05 g mL–1 folic acid, and the sample throughput is 20 h–1. In combination with an on-line filter and dilution, an automated drug-dissolution system was established. The proposed method has been successfully applied to the determination of folic acid in pharmaceutical preparations and dissolution testing.  相似文献   

13.
A flow-injection immunoassay (FI-IA) method with amperometric detection for aflatoxin M1 (AFM1) determination in milk has been developed. The first step consists in an incubation of the sample containing AFM1 (Ag) with fixed amounts of anti-AFM1 antibody (Ab) and of the tracer (Ag*, AFM1 covalently coupled to HRP) until equilibrium is reached. In this mixture a competition occurs between Ag and Ag* for the Ab. The mixture is then injected into a flow system where the separation of the free tracer (Ag*) and the antibody-bound tracer (AbAg*) is performed in a column with immobilized Protein G. The antigen–antibody complexes are retained in the column due to the high affinity of the Protein G for the antibody. The activity of the eluted enzyme label is then amperometrically detected.

The immunoassay was optimised relative to conditions for antibody–antigen incubation (pH, incubation time, ionic strength, temperature) and enzymatic label detection. This method showed a dynamic concentration range between 20 and 500 ppt AFM1, a low detection limit (11 ppt), good reproducibility (RSD < 8%) and a high throughput (six samples per hour in triplicate). Different milk samples were analysed and the results were in good agreement with those obtained by HPLC using the AOAC 2000.08 method.  相似文献   


14.
A long-life capillary enzyme bioreactor was developed that determines glucose concentrations with high sensitivity and better stability than previous systems. The bioreactor was constructed by immobilizing glucose oxidase (GOx) onto the inner surface of a 0.53 mm i.d. fused-silica capillary that was part of a continuous-flow system. In the presence of oxygen, GOx converts glucose to gluconic acid and hydrogen peroxide (H2O2). Hydrogen peroxide detection was accomplished using an amperometric electrochemical detector. The integration of this capillary reactor into a flow-injection (FIA) system offered a larger surface-to-volume ratio, reduced band-broadening effects, and reduced reagent consumption compared to packed column in FIA or other settings. To obtain operational (at ambient temp) and storage (at 4 °C) stability for 20 weeks, the glucose biosensing system was prepared using an optimal GOx concentration (200 mg/mL). This exhibited an FIA peak response of 7 min and a detection limit of 10 μM (S/N = 3) with excellent reproducibility (coefficient of variation, CV < 0.75%). It also had a linear working range from 101 to 104 μM. The enzyme activity in this proposed capillary enzyme reactor was well maintained for 20 weeks. Furthermore, 20 serum samples were analyzed using this system, and these correlated favorably (correlation coefficient, r2 = 0.935) with results for the same samples obtained using a routine clinical method. The resulting biosensing system exhibited characteristics that make it suitable for in vivo application.  相似文献   

15.
In this work, flow-injection system with potentiometric detection was tested for determination of total carboxylic acid concentration. Detection part of the examined system consists of ion-selective electrodes (ISEs) with polymer membranes of different compositions. First electrode is based on Zr(IV)-tetraphenylporphyrin as ionophore selective towards carboxylic acid anions, the membrane of second one contains only liphophilic anion exchanger - tridodecylmethylammonium chloride. Final response of the system is a result of combination of EMF signals from both electrodes. Combination of two detectors enables significant decrease of differences between potentiometric signals induced by mixtures of studied anions of various concentrations as compared to results obtained only with metalloporphyrin-based ISE. The use of anion-exchanger based detector allows for elimination of the influence of aliphatic carboxylic acids lipophilicity.Proposed potentiometric flow-injection system was employed for determination of short-chain aliphatic carboxylic acids (so-called VFA - volatile fatty acids) in samples originating from an anaerobic digester. Results obtained for these relatively complicated samples are in good agreement with results obtained with the use of reference colorimetric method.Linear response towards carboxylic acids was observed in the concentration range of 10−4 to 10−2 mol dm−3, with the slopes in the range of −110 to −150 mV dec−1 (for acetate and butyrate, respectively). System enables for determination of about 6 samples per hour. Life time of ISEs average about 2 months.  相似文献   

16.
A high sensitive flow-injection chemiluminescence method for determination of calf thymus DNA and herring sperm DNA has been developed. The method is based on the chemiluminescence reaction of Rhodamine B-cerium(IV)-thermally denatured DNAs in sulfuric acid media. The proposed procedure allows quantitation of DNAs in the range 2.6×10−5 to 0.26 μg ml−1 for calf thymus DNA and 5.0×10−8 to 5.0×10−5 μg ml−1 for herring sperm DNA with correlation coefficients 0.9998 and 0.9996 (both n=11), respectively. The detection limits (3σ) are 6.5×10−6 μg ml−1 for calf thymus DNA and 4.3×10−8 μg ml−1 for herring sperm DNA. The possible mechanism of chemiluminescence in the system is discussed.  相似文献   

17.
Oguma K  Suzuki T  Saito K 《Talanta》2011,84(5):1209-1214
A flow injection method has been developed for the determination of uranium in seawater combining the on-line preconcentration with spectrophotometric detection. An aliquot (10 mL) of the seawater sample adjusted to pH 5.5 was injected into the analytical system and uranium was adsorbed on the column packed with styrene-divinylbenzene copolymer resin (Bio-Beads SM-2) modified with dodecylamidoxime which showed high selectivity to uranium. Uranium was then eluted with 0.01 M hydrochloric acid and detected spectrophotometrically after the reaction with Chlorophosphonazo III. Interference from calcium and strontium was masked with cyclohexanediaminetetraacetic acid added to the chromogenic reagent solution. The sample throughput, the detection limit (3σ), and the preconcentration factor were 23 per hour, 0.13 μg/L, and 20, respectively, when the sample injection volume was kept at 10 mL. The precision at the 2 μg/L level was less than 4% (RSD). The proposed method was applied to the determination of uranium in the seawater samples collected off the Boso peninsula, Japan and the uranium concentration was found to be ca. 3 μg/L, which is close to the literature data. The yield of the recovery test ranged from 95% to 99%.  相似文献   

18.
流动注射化学发光法测定兽药制剂中恩诺沙星   总被引:2,自引:0,他引:2  
建立了流动注射化学发光检测恩诺沙星的新方法.考察和优化了影响KMnO_4-Na_2S_2O_3-恩诺沙星体系化学发光强度的条件,通过比较荧光光谱和化学发光光谱探讨了化学发光机理.在3.0×10~(-7)~3.0×10~(-6) g/mL范围内,化学发光强度与恩诺沙星的浓度之间呈现良好的线性关系.检出限为1.1×10~(-7) g/mL,相对标准偏差为2.7%.本方法已用于兽药制剂中恩诺沙星含量的测定.  相似文献   

19.
Dissolved reactive phosphorus (DRP) was determined as orthophosphate (PO4-P) in fresh and saline water samples by flow-injection (FI) amperometry, without and with in-valve column preconcentration. Detection is based on reduction of the product formed from the reaction of DRP with acidic molybdate at a glassy carbon working electrode (GCE) at 220 mV versus the Ag/AgCl reference electrode. A 0.1 M potassium chloride solution was used as both supporting electrolyte and eluent in the preconcentration system. For the FI configuration without preconcentration, a detection limit of 3.4 μg P l−1 and sample throughput of 70 samples h−1 were achieved. The relative standard deviations for 50 and 500 μg P l−1 orthophosphate standards were 5.2 and 5.9%, respectively. By incorporating an ion exchange preconcentration column, a detection limit of 0.18 μg P l−1 was obtained for a 2-min preconcentration time (R.S.D.s for 0.1 and 1 μg P l−1 standards were 22 and 1.0%, respectively). Potential interference from silicate, sulfide, organic phosphates and sodium chloride were investigated. Both the systems were applied to the analysis of certified reference materials and water samples.  相似文献   

20.
A microfabricated device has been developed for fluorimetric detection of potassium ions without previous separation. It is based on use of a fluorescent molecular sensor, calix–bodipy, specially designed to be sensitive to and selective for the target ion. The device is essentially made of a Y-shape microchannel moulded in PDMS fixed on a glass substrate. A passive mixer is used for mixing the reactant and the analyte. The optical detection arrangement uses two optical fibres, one for excitation by a light-emitting diode, the other for collection of the fluorescence. This system enabled the flow-injection analysis of the concentration of potassium ions in aqueous solutions with a detection limit of 0.5 mmol L−1 and without interference with sodium ions. A calibration plot was constructed using potassium standard solutions in the range 0–16 mmol L−1, and was used for the determination of the potassium content of a pharmaceutical pill. Figure Photography of the microfluidic channel showing the ridges in the PDMS substrate at the top of the channel  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号