首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Headspace solid-phase microextraction and gas chromatography/mass spectrometry (HS-SPMEGC/MS) method combined with XCMS Online was tentatively applied to characterize the dysregulated volatile organic metabolites (VOMs) in benign and malignant pleural effusions. A total of 9 dysregulated feature groups were isolated from metabolic features in 35 pleural effusion samples (20 benign effusions and 15 malignant ones from lung cancer patients). Principle component analysis, partial least squares discriminant analysis (PLS-DA) and orthogonal PLS-DA were built to separate benign from malignant pleural effusion groups and to find dysregulated metabolites in significantly different amounts between the two groups. Four dysregulated VOMs such as 2-ethyl-1-hexanol, cyclohexanone, 1,2,4,5-tetramethylbenzene and naphthalene were selected according to the variable influence on the projection value. The concentration of the four dysregulated VOMs in benign and malignant effusions were further determined by external standard method. The median concentrations of 4 VOMs in malignant effusion samples were from 4.7 to 91,121.9 nM, whereas their median levels were only 1.9–318.3 nM in benign ones. The results show that the proposed SPMEGC/MS-based metabolomic approach combined with XCMS Online data processing is a simple, rapid and available method for the characterization of dysregulated VOMs in malignant and benign pleural effusions.  相似文献   

2.
Free fatty acids (FFAs), major cellular metabolites, play an important role during tumor pathogenesis. Enhanced de novo fatty acid synthesis in tissues is a characteristic feature of cancer. Therefore, measurement of FFA concentration in biological samples is beneficial for cancer research and clinical diagnosis. Herein, a rapid, stable, and sensitive detection methodology was established to simultaneously quantify 22 FFAs using high-performance liquid chromatography/electrospray ionization tandem mass spectrometry (HPLC/ESI–MS/MS). The HPLCMS/MS system was run in negative ion mode for 15 min using multiple reaction monitoring. The lipids were extracted from colon tissues of colon cancer patients and then injected into the HPLCMS/MS system for analysis. Colon samples were analyzed by inter-day repeatability and intra-day repeatability, with less than 5 % deviation for most fatty acids. This approach is successful to determine low picogram concentrations of each FFA molecule using milligrams of tissue, and provides a promising method for FFA microanalysis in clinical samples.  相似文献   

3.
4.
The therapeutic importance of platinum (Pt) compounds, the growing accessibility of gas chromatography/mass spectrometry (GC/MS) systems in clinical laboratories, and the lack of a mass spectrometric method for the determination of Pt in biological samples motivated us to develop an isotope dilution GC/MS assay for Pt. The method is based on the use of lithium bis(trifluoroethyl) dithiocarbamate, Li(FDEDTC), as a chelating agent and enriched 192Pt for isotope dilution. Conditions were optimized for the precise and accurate determination of isotope ratios of Pt by using a 10-m DB-l fused silica capillary column and a reverse-geometry double-focusing mass spectrometer with selected ion monitoring. An overall precision of 1% was obtained by combining within-run precision and between-run precision at the 10-ng level. No appreciable memory effect was observed when samples with different isotope ratios were analyzed sequentially. The method was validated by the quantitation of Pt in National Institute of Standards and Technology freeze-dried urine sample SRM 2670. A concentration value of 125 ± 6 /Lg/L (n = 6) was obtained by using four different sets of isotope ratios in the molecular ion and supports the National Institute of Standards and Technology recommended value of 120 ± ? μg/L. Limits-of-quantitation, estimated at 3 μg/L, are made possible by the high sensitivity of the method and the low blank value for Pt.  相似文献   

5.
This study evaluates solid-phase micro-extraction (SPME) coupled with gas chromatography–mass spectrometry (GC–MS) to determine trace levels of bis-phenol A in water and leached from plastic containers. In our study, we used very thin composite membranes prepared in the laboratory. The extraction using headspace post-derivatization with bis(trimethylsilyl) trifluoroacetamide (BSTFA), containing 1 % trimethylchlorosilane (TMCS) vapor, following SPME was compared with extraction without derivatization. The SPME experimental procedures to extract bis-phenol A in water were optimized with a relatively polar polyacrylate (PA)-coated fiber, an extraction time of 50 min, and desorption at 300 °C for 2 min. Headspace derivatization following SPME was performed using 7 μL of BSTFA with 1 % TMCS at 65 °C for 30 s. The precision was 5.2 % without derivatization and 9.0 % headspace derivatization. The detection limit was determined to be at the nanogram per liter level. When SPME was used following headspace derivatization, the detection limit was one order of magnitude better than that achieved without derivatization. The results of this study reveal the adequacy of the SPME–GC–MS method for analyzing bisphenol A leached from plastic containers. The concentrations of bisphenol A leached from plastic containers into water ranged from 0.7 to 78.5 μg L?1.  相似文献   

6.
A sensitive and ultra-fast method utilizing the laser diode thermal desorption ion source using atmospheric pressure chemical ionization coupled to tandem mass spectrometry (LDTD-APCI-MS/MS) was developed for the quantitative analysis of BKM120, an investigational anticancer drug in human plasma. Samples originating from protein precipitation (PP) followed by salting-out assisted liquid-liquid extraction (SALLE) were spotted onto the LazWell? plate prior to their thermal desorption and detection by tandem mass spectrometry in positive mode. The validated method described in this paper presents a high absolute extraction recovery (>90 %) for BKM120 and its internal standard (ISTD) [D8]BKM120, with precision and accuracy meeting the acceptance criteria. Standard curves were linear over the range of 5.00 to 2000 ng mL?1 with a coefficient of determination (R 2) >0.995. The method specificity was demonstrated in six different batches of human plasma. Intra- and inter-run precision as well as accuracy within ±20 % at the lower limit of quantification (LLOQ) and ±15 % (other levels) were achieved during a three-run validation for quality control (QC) samples. The post-preparative stability on the LazWell? plate at room temperature was 72 h and a 200-fold dilution of spiked samples was demonstrated. The method was applied successfully to three clinical studies (n?=?847) and cross-checked with the validated LC-ESI-MS/MS reference method. The sample analysis run time was 10 s as compared to 4.5 min for the current validated LC-ESI-MS/MS method. The resultant data were in agreement with the results obtained using the validated reference LC-ESI-MS/MS assay and the same pharmacokinetic (PK) parameters were calculated for both analytical assays. This work demonstrates that LDTD-APCI-MS/MS is a reliable method for the ultra-fast quantitative analysis of BKM120 which can be used to speed-up and support its bioanalysis in the frame of the clinical trials.  相似文献   

7.
β-phase polyvinylidene fluoride (PVDF)–BaTiO3 nanocomposite samples have been prepared by solution mixing method. XRD data represent that the crystallinity of PVDF decreases with increase in loading level of BaTiO3 nanoparticles. DSC curve represents that the melting point of PVDF is lightly affected by loading concentration of BaTiO3. The morphology and microstructure of PVDF and PVDF embedded by BaTiO3 nanofillers were investigated by using inverted contrast microscopy (ICM) and scanning electron microscopy (SEM). FTIR interferrometry is proven that PVDF and BaTiO3 are not chemically interacting; therefore, interaction of BaTiO3 is van der Waals type of interaction. The thermally stimulated discharge current (TSDC) of PVDF and PVDF–BaTiO3 nanocomposites sample was characterized by single peak. The observed TSDC peak is discussed on the basis of dipolar and interfacial polarization.  相似文献   

8.
The 4-POBN[α-(4-pyridyl-l-oxide)-N-tert-butyl-nitrone] radical adducts of ethyl and pentyl radicals were determined by a combination of high performance liquid chromatography (HPLC) combined with electron paramagnetic resonance (EPR) with HPLC-electrospray (ESI)-mass spectrometry and HPLC-thermospray (TSP)-MS. The identifIcation of the peak corresponding to the spin-trapped radical was done by performing HPLC-EPR under the same chromatographic conditions as the HPLC-MS. The radical adducts could be determined by both techniques, even though for ESI only 12 μL/min of the total 1 mL/min HPLC flow rate could be directed into the ion source.  相似文献   

9.
High-resolution mass spectrometry (HRMS), hybrid tandem mass spectrometry (MS/MS) (EBqQ), and photoelectron-photoion coincidence (PEPICO) experiments were conducted to examine a possible ortho-ortho effect resulting in a novel [M - 35]+ fragment ion in 2-alkyl-4, 6-dinitrophenols. For compounds having ethyl or larger alkyl substituents, [M35]+ was observed only when [M - 18]+ ions were present, with the ortho nitro group being involved in the reaction to [M- 35]+. For [M - 18]+ and [M - 35]+, HRMS results were consistent with losses of H2O and H2O + OH, respectively, whereas MS/MS results indicated a sequential reaction due to metastable dissociations. The appearance energy determined by PEPICO for [M - 35]+ was found to be greater than the appearance energy for [M - 18]+, thus supporting a sequential reaction. 69–75).  相似文献   

10.
Polychlorinated biphenyls (PCBs) are among the most ubiquitous pollutants in the environment, and their metabolism leads to the formation of hydroxylated PCBs (OH-PCBs) and methyl sulfone PCBs (MeSO2-PCBs). These metabolites are generally more hydrophilic than the parent compound, and therefore are more easily eliminated from the body. However, some congeners have been shown to be strongly retained in human blood, binding to transthyretin with an affinity that is, in general, greater than that of the natural ligand thyroxin itself, which could result in toxicological effects, particularly on the thyroid system. Currently available analytical methods require, in general, extensive sample preparation, which includes a series of time-consuming and low-throughput liquid–liquid and back extractions, evaporations, several cleanup steps, and in some cases, derivatization prior to analysis by gas chromatography (GC) or liquid chromatography (LC) coupled with mass spectrometry (MS). Recent developments in the use of LC coupled with tandem MS (MS/MS) have brought some improvements in terms of sample preparation for the determination of PCB metabolites in blood, although there are still possibilities for continued development. The selected literature has evidenced few studies of LC–MS/MS-based methods, a lack of analytical standards, nonassessment of lower-chlorinated OH-PCBs, and scarce attention to MeSO2-PCBs in blood. This review aims to evaluate critically the currently available analytical methods for determination of OH-PCBs and MeSO2-PCBs in blood.  相似文献   

11.
p-Aminothiophenol (pATP) functionalized multi-walled carbon nanotubes (MWCNTs) have been demonstrated as an efficient pH sensor for living cells. The proposed sensor employs gold/silver core-shell nanoparticles (Au@Ag NPs) functionalized MWCNTs hybrid structure as the surface-enhanced Raman scattering (SERS) substrate and pATP molecules as the SERS reporters, which possess a pH-dependent SERS performance. By using MWCNTs as the substrate to be in a state of aggregation, the pH sensing range could be extended to pH 3.0~14.0, which is much wider than that using unaggregated Au@Ag NPs without MWCNTs. Furthermore, the pH-sensitive performance was well retained in living cells with a low cytotoxicity. The developed SERS-active MWCNTs-based nanocomposite is expected to be an efficient intracellular pH sensor for bio-applications.  相似文献   

12.
Nonsteroidal anti-inflammatory drugs (NSAIDs) are the group of drugs having the therapeutic efficacy of analgesic and antipyretic. To detect health-threatening residues of NSAIDs, a fast and easy multiresidue method based on liquid chromatography tandem mass spectrometry (LC-MS/MS) was described. Ten NSAIDs were extracted from the tissues using 2 mL of acetonitrile and 0.1 mL of 2 mM ammonium formate in distilled water. After clean-up using C18 sorbent, it was evaporated under nitrogen, reconstituted with 1 mL distilled water and analyzed by LC-MS/MS. The method was validated based on guideline for residue testing laboratory. Furthermore, the method has also been applied successfully to detect ten NSAIDs from bovine, porcine, and chicken liver tissues. In a total of 315 liver samples tested, acetylic salicylic acid was detected from 28 porcine and 2 chicken liver tissues at levels of 13?~?576 and 50?~?53 ng/g, respectively. Subsequently, paracetamol was detected in 15 porcine liver tissues with a detection levels of 28?~?381 ng/g. Phenylbutazone and its metabolite, oxyphenylbutazone, were detected at 247 and 15 ng/g range in one of the bovine liver tissue, respectively.  相似文献   

13.
A new nanoparticle formulation has been developed by using dimethyl-β-cyclodextrin (DM-β-CD) with raloxifene HCl or tamoxifene citrate. Both drugs are insoluble in water and represent as low bioavailibilities when given orally. Tamoxifen has an FDA approval for breast cancer prevention and the treatment. Raloxifene is approved for osteoprosis treatment. Both drugs were selected as a model drug antitumoural activity and MMP-2 inhibition studies were evaluated on breast cancer cell lines MCF-7 and MDA-MB 231. MMP-2 is known to be responsible for tumour invasion and initation the of angiogenesis. DM-β-CD and sodium taurocholate (NaTC) have been used as absorption enhancers to increase penetration effect of raloxifene/tamoxifen on the tumour cells and aimed to provide high antitumoral activity and MMP-2 inhibition results by developed nanoparticle formulations. The effects of two absorption enhancers were compared. The highest antitumoral activity was observed for DM-β-CD—raloxifene HCl nanoparticle formulation and also MMP-2 enzyme inhibit effectively.  相似文献   

14.
Ultraperformance convergence chromatography/tandem triple quadrupole mass spectrometry (UPC2-MS/MS) is a novel tool in separation science that combines the advantages of supercritical fluid chromatography with ultraperformance liquid chromatography/MS/MS technology. The use of nontoxic CO2 fluid and a postcolumn additive to complement MS/MS allows better control of analyte retention for chiral separation and high-sensitivity determination with different chiral stationary phases. This paper reports the stereoselective separation and determination of the chiral neonicotinoid sulfoxaflor in vegetables and soil by UPC2-MS/MS. Baseline resolution (Rs?≥?1.56) of and high selectivity (LOQ?≤?1.83 μg/kg) for the four stereoisomers were achieved by postcolumn addition of 1 % formic acid–methanol to a Chiralpak IA-3 using CO2/isopropanol/acetonitrile as the mobile phase at 40 °C, 2,500 psi, and for 6.5 min in electrospray ionization positive mode. Rearranged Van’t Hoff equations afforded the thermodynamic parameters ΔH ο and ΔS ο, which were analyzed to promote understanding of the enthalpy-driven separation of sulfoxaflor stereoisomers. The interday mean recovery, intraday repeatability, and interday reproducibility varied from 72.9 to 103.7 %, from 1.8 to 9.2 %, and from 3.1 to 9.4 %, respectively. The proposed method was used to study the pharmacokinetic dissipation of sulfoxaflor stereoisomers in soil under greenhouse conditions. The estimated half-life ranged from 5.59 to 6.03 d, and statistically nonsignificant enantioselective degradation was observed. This study not only demonstrates that the UPC2-MS/MS system is an efficient and sensitive method for sulfoxaflor stereoseparation, but also provides the first experimental evidence of the pharmacokinetic dissipation of sulfoxaflor stereoisomers in the environment. Graphical Abstract
Chemical structure and UPC2-MS/MS separation chromatogram of sulfoxaflor. (* stereogenic center)  相似文献   

15.
The ability of MALDI TOF MS (matrix-assisted laser desorption ionisation time-of-flight mass spectrometry) to identify cultivable microflora from two waste disposal sites from non-ferrous metal industry was analysed. Despite the harsh conditions (extreme pH values and heavy metal content in red mud disposal site from aluminium production or high heavy metal content in nickel sludge), relatively high numbers of bacteria were recovered. In both environments, the bacterial community was dominated by Gram-positive bacteria, especially by actinobacteria. High-quality MALDI TOF mass spectra were obtained but most of the bacteria isolates could be not identified using MALDI Biotyper software. The overall identification rate was lower than 20 %; in two of the environments tested identification rates were lower than 10 %. As a dominant bacterial species, Microbacterium spp. in drainage water from an aluminium red mud disposal site near ?iar nad Hronom, Bacillus spp. in red mud samples from the same site, and Arthrobacter spp. from nickel smelter sludge near Sereï were identified by a combination of the Biolog system and 16S rRNA sequence analysis. As the primary focus of the MALDI TOF MS-based methodology is directed towards medically important bacteria, reference database spectra expansion and refinement are needed to improve the ability of MALDI TOF MS to identify environmental bacteria, especially those from extreme environments.  相似文献   

16.
In the development of nanoparticle-based vaccine adjuvants, the interaction between nanoparticles (NPs) and the cells is a key factor. To control them, we focused on the relationship between the hydrophobicity of the side chains and the cell membrane. In this study, amphiphilic poly(γ-glutamic acid) (γ-PGA), using various types of hydrophobic side chains, was synthesized and used to prepare NPs for evaluating the membrane disruptive activity. When leucine ethyl ester (Leu), methionine ethyl ester (Met), or tryptophan ethyl ester (Trp) was grafted, each polymer formed monodispersed NPs at physiological conditions. Significantly, NPs composed of Leu and Trp showed a membrane disruptive activity at the endosomal environment (pH 5–6.5), while NPs composed of Met did not show. This might be due to the weak hydrophobicity of Met compared to that of Leu and Trp, which demonstrated that the interaction between NPs and cells could be controlled by designing the polymer compositions.  相似文献   

17.
To investigate the effect of surface functionality on the morphology of polymer/silica composite, poly(styrene-alt-maleic anhydride) (SMA) spheres prepared via precipitation polymerization method was employed. In water/ethanol solution, diethanolamine (DEA) was used to catalyze the hydrolysis reaction of tetraethoxysilane (TEOS), and rambutan-like poly(styrene-alt-maleic anhydride)/silica (SMA/SiO2) microspheres were synthesized through in situ sol–gel process. The obtained structure and morphology were characterized by FTIR, NMR, TEM, SEM, and TGA. The results showed that the hydrolyzed SMA chains on the surface was crucial to the nucleation and growth of silica, and the morphologies of SMA/SiO2 composite microspheres can be controlled by the amount of DEA and the ratio of SMA/TEOS. In addition, the SMA/SiO2 microspheres were used to prepare hierarchical structure of SMA/SiO2/Ag particles, which were utilized for the construction of surface-enhanced Raman scattering substrate (SERS).  相似文献   

18.
Tryptic digests were analyzed by means of online microbore liquid chromatography combined with mass spectrometry (LC/MS) for some common proteins. Following conventional enzymatic digestion with trypsin, the freeze-dried residues were dissolved in high-performance liquid chromatography (HPLC) eluent and subjected to gradient reversed-phase microbore HPLC separation with mass spectrometric detection. The latter was done in the full-scan single or tandem (MS/MS) mass spectrometry mode. The formation of gas-phase ions from dissolved analytes was accomplished at atmospheric pressure by pneumatically assisted electrospray (ion spray) ionization. This produced field-assisted ion evaporation of dissolved ions, which could then be mass-analyzed for molecular mass or structure. In the full-scan LC/MS mode, the masses for the peptide fragments in the tryptic digests can be determined as either their singly or multiply charged ions. When the molecular weights of the peptides lie outside the mass range of the mass spectrometer, the multiply charged feature of these experimental conditions still provides reliable molecular weight determinations. In addition, collision-activated dissociation (CAD) on selected peptide precursor ions provides online LC/MS/MS sequence information for the tryptic fragments. Results are shown for the tryptic digests of horse heart cytochrome c, bovine β-lactoglobulin A, and bovine β-lactoglobulin B.  相似文献   

19.
The poly(styrene-b-butadiene-b-styrene) (SBS) triblock copolymer and linear low-density polyethylene (LLDPE) were blended and irradiated by γ rays to prepare shape memory polymer (SMP). Different weight fractions of conductive carbon black (CB) were filled into SMP to form a novel electroactive shape memory CB/SBS/LLDPE composite. The CB reinforced radiation cross-linked SBS/LLDPE blends for the improvement of the mechanical weakness and conductivity of SBS/LLDPE bulk and for wide practical engineering uses. The electroactive shape memory CB/SBS/LLDPE composites were investigated by electrical properties, mechanical, dynamic mechanical analysis (DMA), differential scanning calorimetry (DSC), scanning electron microscopy (SEM), and electroactive shape memory effects. It is found that the tensile strength, storage modulus, and resistance against mechanical and thermal mechanical cycle loading in the developed composites increased due to the role of reinforcement of CB. The melting temperatures and volume resistance of the composites decreased with the increment of CB for excellent electrical conductivity of CB. The electroactive shape memory effects of developed CB/SBS/LLDPE composites were affected by CB weight fractions and applied voltage, while good shape recovery could be obtained in the shape recovery test. When the CB fraction is more than 5 wt%, full recovery can be observed after tens of seconds and shape recovery speed increased with CB fractions and voltage increasing. However, the shape recovery rate decreases slightly with increment of cycle times.  相似文献   

20.
We have simulated IR and pyrolysis gas chromatography mass spectrometry (Py-GCMS) spectra of six polymers (PE, PP, PS, PET, N6, PVDF) with the density-functional theory and quantum molecular dynamics calculations on model oligomers. In the former calculations, experimental harmonic frequencies of the polymers have been assigned from the simulated IR spectra. In the latter QMD calculations on thermal decomposition of polymer models, the approximated mass spectra of six (PE, PP, PS, PET, N6, PVDF) polymers were almost in good accordance with the experimental results in Py-GC/MS, although we adjusted the decomposition temperatures to 2240, 2520, and 2800 K as the average absolute deviation of 8%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号