共查询到20条相似文献,搜索用时 15 毫秒
3.
JPC – Journal of Planar Chromatography – Modern TLC - A successful attempt has been made to develop and validate a stability-indicating high-performance thin-layer chromatography... 相似文献
4.
Liquid chromatography–ion trap mass spectrometry was employed to investigate the metabolism of linarin in rats. Identification and structural elucidation of the metabolites were performed by comparing the differences in molecular masses, retention times, and full scan MS n spectra between linarin and its metabolites. Six metabolites (acacetin, apigenin, acacetin glucuronide, apigenin glucuronide, acacetin sulfate, apigenin sulfate) were detected in rat urine after oral administration of linarin at the dose of 50 mg kg ?1. Furthermore, a selective and sensitive liquid chromatography–triple quadruple mass spectrometry assay was developed and validated for the simultaneous determination of linarin and acacetin (the major metabolite of linarin) in rat urine. Chromatographic separation was carried out on a C 18 column, and mass spectrometric detection was performed using a triple-quadrupole mass spectrometer coupled with an electrospray ionization source in the positive ion mode. Quantitation of linarin and acacetin was performed using selected reaction monitoring of precursor–product ion transitions at m/z 593 → 285 for linarin, 285 → 242 for acacetin, and 303 → 153 for hesperitin (internal standard), respectively. The assay exhibited good linearity ( r > 0.9900) for both linarin and acacetin. The intra- and inter-day precisions were <13.4 % and the accuracy was between ?8.1 and 3.1 %. The method was successfully applied to the urinary excretion study of linarin in rats after oral administration of linarin. 相似文献
5.
A simple, fast and sensitive LC–MS/MS method was developed and validated for the simultaneous determination of the concentrations of temsirolimus and its major metabolite, sirolimus, in human whole blood. The blood sample (100 μL) after adding temsirolimus-d7 and sirolimus-d3 internal standards was precipitated with 0.200 mL of methanol/0.300 M zinc sulfate (70/30, v/v), then analyzed by a Shimatzu LC system coupled to a Sciex API-5000 mass spectrometer. The chromatographic separation was carried out on a BDS Hypersil C8 column (50 × 3.0 mm, 5 μm) at 50 °C with a mobile phase composed of methanol/water/formic acid (72/28/0.1) (v/v/v) containing 2.50 mM ammonium acetate. Mass spectrometric detection was performed using electrospray positive ionization with multiple reaction monitoring mode. This method was validated from 0.250 to 100 ng mL−1 for temsirolimus and 0.100 to 40.0 ng mL−1 for sirolimus. The lower limits of quantitation were 0.25 ng mL−1 for temsirolimus and 0.1 ng mL−1 for sirolimus. The intra-day and inter-day precisions (CV %) of spiked quality control (QC) samples were less than 10.4 and 9.6 %, respectively. The accuracies as determined by the relative error for QC samples were less than 12.1 % for intra-day and 7.3 % for inter-day. No significant matrix effect was observed. This method has been successfully applied to analyze clinical pharmacokinetic study samples. The assay reproducibility was also demonstrated by using incurred samples. 相似文献
6.
A simple, fast and sensitive LC?CMS/MS method was developed and validated for the simultaneous determination of the concentrations of temsirolimus and its major metabolite, sirolimus, in human whole blood. The blood sample (100???L) after adding temsirolimus- d7 and sirolimus- d3 internal standards was precipitated with 0.200?mL of methanol/0.300?M zinc sulfate (70/30, v/v), then analyzed by a Shimatzu LC system coupled to a Sciex API-5000 mass spectrometer. The chromatographic separation was carried out on a BDS Hypersil C8 column (50?×?3.0?mm, 5???m) at 50?°C with a mobile phase composed of methanol/water/formic acid (72/28/0.1) (v/v/v) containing 2.50?mM ammonium acetate. Mass spectrometric detection was performed using electrospray positive ionization with multiple reaction monitoring mode. This method was validated from 0.250 to 100?ng?mL ?1 for temsirolimus and 0.100 to 40.0?ng?mL ?1 for sirolimus. The lower limits of quantitation were 0.25?ng?mL ?1 for temsirolimus and 0.1?ng?mL ?1 for sirolimus. The intra-day and inter-day precisions (CV?%) of spiked quality control (QC) samples were less than 10.4 and 9.6?%, respectively. The accuracies as determined by the relative error for QC samples were less than 12.1?% for intra-day and 7.3?% for inter-day. No significant matrix effect was observed. This method has been successfully applied to analyze clinical pharmacokinetic study samples. The assay reproducibility was also demonstrated by using incurred samples. 相似文献
9.
A sensitive and selective liquid chromatography tandem mass spectrometry method for quantitative determination of lobeline hydrochloride in rabbit plasma was developed and validated. After addition of triazolam as internal standard, protein precipitation by acetonitrile was used as sample preparation. Chromatographic separation was achieved on a Zorbax SB-C18 column with acetonitrile-0.1% formic acid as mobile phase with gradient elution. Electrospray ionization source was applied and operated in positive ion mode; multiple reaction monitoring mode was used for quantification using target fragment ions m/z 338.1 → 315.8 for lobeline hydrochloride and m/z 342.9 → 308.0 for the IS. Calibration plots were linear over the range of 2–500 ng mL ?1 for lobeline hydrochloride in plasma. Lower limit of quantitation for lobeline hydrochloride was 2 ng mL ?1. Mean recovery of lobeline hydrochloride from plasma was in the range 97.5–102.3%. RSD of intra-day and inter-day precision were both <9%. This developed method is successfully used in pharmacokinetic study of lobeline hydrochloride in rabbit. 相似文献
12.
Nine impurities in amikacin sulfate made in China were separated and identified by HPLC–MSn for the further improvement of official monographs in pharmacopoeias. The mass fragmentation patterns and structural assignment of these impurities were studied. The column was Acchrom Click XIon (250 × 4.6 mm, 5 μm). The mobile phase was 250 m mol L−1 ammonium formate and 1.4 % formic acid aqueous solution–acetonitrile–water (30:48:22). In positive mode, full scan LC–MS was first performed in order to obtain the m/z value of the protonated molecules, LC–MS–MS was then carried out on the compounds of interest on AB SCIEX 4000 Q TRAP™ composite triple quadrupole/linear ion trap tandem mass spectrometer. The complete fragmentation patterns of nine impurities were studied and used to obtain information about the structure of these impurities. The structures of nine impurities in amikacin sulfate were deduced based on the HPLC–MSn data, in which three impurities were novel impurities. Three novel impurities were 1-N-(l-4-amino-2-hydroxybutyryl) derivative of 4-O-(6-AG)DS, 1-N-(l-4-amino-2-hydroxybutyryl) derivative of 6-O-(3-AG)DS and 1-N-(l-4-amino-2-hydroxybutyryl) derivative of kanamycin D. 相似文献
13.
A sensitive, high-throughput and economic liquid chromatographic method for determination of fenofibric acid in human plasma was developed and validated by ultraviolet detection and tandem mass spectrometry, then applied in pharmacokinetic study to investigate Lipanthyl™ 200 mg MC bioavailability under food and fasting conditions. Fenofibric acid with 2-chloro fenofibric acid-d6 (internal standard) was extracted from 100 µL of human plasma by acetonitrile in a single extraction step. 25 and 2 µL from supernatant were injected onto ACE column, 50 mm, 5 micron with 4.6 mm inner diameter for LC–UV and 2.1 mm for LC–MS/MS, and both systems were eluted isocratically by water:methanol:formic acid (35:65:0.1, v/v/v), with a constant flow rate of 1 mL min−1. The established calibration curve was linear between 0.05–20 µg mL−1, and the within- and between-day precisions were all below 13 % in both LC–MS/MS and LC–UV systems during validation, and accuracies ranged between 91 and 112 %. Twenty-eight healthy adult subjects participated in this clinical study, and the pharmacokinetic parameters including coefficient of variation were calculated and discussed. A dramatic decrease in C
max and AUC0-72 (3.63- and 1.85-fold, respectively) were observed for Lipanthyl™ MC under fasting conditions with more variable inter subject measurements comparing to the fed state. 相似文献
14.
In China the roots of Euphorbia kansui T.N. Liou ex T.P. Wang, known as ‘kansui’, have been used for centuries as a herbal remedy for edema, ascites, and asthma. Kansui, has inflammatory and tumor-promoting toxicity, and other side-effects, however, which have seriously restricted its clinical application. In the work discussed in this paper a simple and rapid LC–DAD–ESI-MS–MS method has been established for separation and characterization of the main compounds in the toxic fraction of E. kansui roots. Twelve diterpene derivatives were identified in the inflammatory fraction of kansui: kansuinine C, kansuinine B, kansuinine A, kansuinine D, 5- O-benzoyl-20-deoxyingenol, kansuinine E, kansuiphorin C, 3- O-benzoyl-20-deoxyingenol, 3- O-(2′ E,4′ Z-decadienoyl)-5- O-acetylingenol, 3- O-(2′ E,4′ Z-decadienoyl)-20-deoxyingenol, 20- O-(2′ E, 4′ E-decadienoyl)ingenol, and 3- O-(2′ E,4′ Z-decadienoyl)-20- O-acetylingenol. The inflammatory fraction was separated on a C 18 reversed-phase column with a mobile phase gradient. The proposed method is a scientific and technical platform enabling the herbal medicine industry to perform quality control and ensure the safety of preparations that contain this class of poisonous diterpenoids. 相似文献
15.
A sensitive, selective, and simple liquid chromatography-tandem mass spectrometry method has been developed for the simultaneous separation and determination of isosorbide dinitrate and its active metabolite, isosorbide 5-mononitrate, in human plasma. Topiramate was used as the internal standard. Sample preparation consisted of a simple one-step liquid–liquid extraction with ethylacetate without pH adjustment. The method was fully validated with respect to linearity, sensitivity, specificity, recovery, accuracy, and precision. Isosorbide dinitrate and isosorbide 5-mononitrate were stable in standard solution and in plasma samples under storage and processing conditions. The assay was successfully applied to the pharmacokinetic study of isosorbide dinitrate and isosorbide 5-mononitrate in human plasma. 相似文献
16.
Acepromazine maleate (Sedalin®) was administered orally to six thoroughbred horses at a dose of 0.15 mg kg−1. Urine and blood samples were collected up to 412 h post-administration. Plasma and urine were hydrolysed; plasma samples were then processed using liquid–liquid extraction and urine samples using solid-phase extraction. A sensitive tandem mass spectrometric method was developed in this study, achieving a lower limit of quantification for acepromazine of 10 pg mL−1 in plasma and 100 pg mL−1 in urine. Acepromazine, hydroxyethylpromazine, hydroxyacepromazine, hydroxyethylpromazine sulphoxide, hydroxyethylhydroxypromazine, dihydroxyacepromazine and dihydroxyhydroxyethylpromazine were detected in the post-administration samples. The parent drug and its metabolites were identified using a combination of UPLC–MS/MS and accurate mass measurement. Separation of the structural isomers hydroxyethylpromazine sulphoxide and hydroxyethylhydroxypromazine was another significant outcome of this work and demonstrated the advantages to be gained from investing in chromatographic method development. 相似文献
17.
Acepromazine maleate (Sedalin ?) was administered orally to six thoroughbred horses at a dose of 0.15?mg?kg ?1. Urine and blood samples were collected up to 412?h post-administration. Plasma and urine were hydrolysed; plasma samples were then processed using liquid–liquid extraction and urine samples using solid-phase extraction. A sensitive tandem mass spectrometric method was developed in this study, achieving a lower limit of quantification for acepromazine of 10?pg?mL ?1 in plasma and 100?pg?mL ?1 in urine. Acepromazine, hydroxyethylpromazine, hydroxyacepromazine, hydroxyethylpromazine sulphoxide, hydroxyethylhydroxypromazine, dihydroxyacepromazine and dihydroxyhydroxyethylpromazine were detected in the post-administration samples. The parent drug and its metabolites were identified using a combination of UPLC–MS/MS and accurate mass measurement. Separation of the structural isomers hydroxyethylpromazine sulphoxide and hydroxyethylhydroxypromazine was another significant outcome of this work and demonstrated the advantages to be gained from investing in chromatographic method development. 相似文献
19.
A rapid and sensitive LC–MS–MS method was developed and validated for the determination of asiaticoside in rat plasma. Asiaticoside was extracted by protein precipitation with acetonitrile, and separated on a C 18 column. The total analytical time was relatively short (4 min), and the limit of quantification was 38 ng mL ?1 using 100 μL of rat plasma. Asiaticoside and the internal standard (felodipine) were monitored in the multi-reaction-monitoring mode as follows: m/z 957.4 → 469.3 and m/z 382.2 → 145.1, respectively. Calibration was linear over a concentration range from 38 to 7,600 ng mL ?1, and the correlation coefficient was greater than 0.998. The recoveries of asiaticoside from plasma were better than 85%, and RSDs of inter-day and intra-day assays were below 10.1%. The method is sensitive and specific, and suitable for pharmacokinetic studies of asiaticoside in rats. 相似文献
20.
A selective, rapid and sensitive liquid chromatography tandem mass spectrometry method has been developed for the simultaneous determination of ramipril and ramiprilat in human plasma using enalapril as the internal standard via one-step extraction with ethyl acetate under acidic condition. The analysis was carried out on a Diamonsil C 18 column (150 mm × 4.6 mm i.d., 5 μm) with a mobile phase consisting of 1% formic acid-acetonitrile (25:75, v/v) at a constant flow rate of 0.5 mL min ?1. The detection was performed on a triple-quadruple tandem mass spectrometer by selective reaction monitoring mode via electrospray ionization. Linear calibration curves of ramipril and ramiprilat were obtained in the concentration range of 0.107–107.0 and 0.262–105.0 ng mL ?1, respectively. The intra- and inter-day precision (RSD) values were below 8.2 and 4.8% for ramipril, 10.4 and 12.3% for ramiprilat, and accuracy (RE) were within ±5.5 and ±3.2%, respectively at all QC levels. The method was utilized to support clinical pharmacokinetic studies in healthy volunteers following oral administration of ramipril tablets. 相似文献
|