首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Applications of affinity interactions in capillary electrophoresis   总被引:2,自引:0,他引:2  
Heegaard NH 《Electrophoresis》2003,24(22-23):3879-3891
Capillary electrophoresis (CE) has proven useful for the study of reversible molecular interactions. This is because highly efficient and reproducible separations take place in an environment where molecular interactions may contribute to selectivity without being inhibited by adverse buffer conditions. Affinity CE may be used to estimate quantitative binding data (binding constants and in some cases binding stoichiometries and rate constants) for various molecular interactions. Specific binding interactions (e.g., based on antibodies or aptamers) may also be utilized to quantitatively measure specific analytes using CE. Applications within these areas are here reviewed with focus on the last three years and with emphasis on novel concepts as well as innovative methodology and technology. It is concluded that the affinity CE approach is of growing versatility and will continue to play an integral role in discovering, characterizing, and exploiting biomolecular interactions.  相似文献   

2.
Recent applications of affinity interactions in capillary electrophoresis   总被引:1,自引:0,他引:1  
Systems biology depends on a comprehensive assignment and characterization of the interactions of proteins and polypeptides (functional proteomics) and of other classes of biomolecules in a given organism. High-capacity screening methods are in place for ligand capture and interaction screening, but a detailed dynamic characterization of molecular interactions under physiological conditions in efficiently separated mixtures with minimal sample consumption is presently provided only by electrophoretic interaction analysis in capillaries, affinity CE (ACE). This has been realized in different fields of biology and analytical chemistry, and the resulting advances and uses of ACE during the last 2.5 years are covered in this review. Dealing with anything from small divalent metal ions to large supramolecular assemblies, the applications of ACE span from low-affinity binding of broad specificity being exploited in optimizing selectivity, e.g., in enantiomer analysis to miniaturized affinity technologies, e.g., for fast processing immunoassay. Also, approaches that provide detailed quantitative characterization of analyte-ligand interaction for drug, immunoassay, and aptamer development are increasingly important, but various approaches to ACE are more and more generally applied in biological research. In addition, the present overview emphasizes that distinct challenges regarding sensitivity, parallel processing, information-rich detection, interfacing with MS, analyte recovery, and preparative capabilities remain. This will be addressed by future technological improvements that will ensure continuing new applications of ACE in the years to come.  相似文献   

3.
When modeling analyte-additive interactions in capillary electrophoresis (CE), it is necessary to correct for all changes in the apparent electrophoretic mobility of an analyte that are not due to specific binding. Current models based on dynamic complexation have corrected for bulk viscosity changes in the background electrolyte (BGE) when additives are used, while assuming negligible changes in the dielectric constant and other physicochemical properties of the solution. In this report, a study of weak interactions between deoxyribonucleotides and hydroxypropyl-beta-cyclodextrin (HP-beta-CD) revealed significant nonideality in binding isotherms. Changes in the dielectric properties of the solution due to the addition of high concentrations of HP-beta-CD to the BGE was observed to alter the electrophoretic mobility of analytes. A relative dielectric correction factor was required to normalize analyte mobilities to a reference state of zero additive concentration. The use of both a relative dielectric factor and a viscosity correction factor was found to increase the accuracy of the model, reflected by a higher degree of correlation between predicted and measured analyte mobilities. This type of correction is particularly relevant when studying weak analyte binding interactions or when using high concentrations of additive in the BGE. This work is vital for accurate determination of weak binding constants and mobility values, as well as providing a deeper understanding of the fundamental parameters influencing a separation in CE.  相似文献   

4.
余方志  章大鹏  袁征  赵强  汪海林 《色谱》2020,38(10):1133-1142
蛋白质-DNA的相互作用在决定细胞命运的许多过程中发挥重要作用,对蛋白质-DNA相互作用的分子机制研究有利于对基本生命过程的理解,为相关疾病的临床治疗及药物筛选提供理论指导。另一方面,利用一些已知的蛋白质-DNA相互作用可以帮助开发先进的生物工程和生命分析技术,为相关研究提供有力的技术支持。因此,建立灵敏、快速的分析方法用于表征蛋白质-DNA的相互作用十分重要。高效毛细管电泳(capillary electrophoresis, CE)技术因其超高的分离效率、极低的样品消耗与较短的分析时间等优势被广泛应用于化学、生命科学和环境科学等多个研究领域。其中,亲和毛细管电泳(affinity capillary electrophoresis, ACE)技术已经成为考察分子间相互作用的重要研究工具。这篇文章综述了亲和毛细管电泳技术自建立以来在蛋白质-DNA相互作用分析方面的研究进展,并对经典的研究工作进行了着重介绍,主要包括三方面的内容:(1)亲和毛细管电泳技术简介;(2)利用亲和毛细管电泳技术进行蛋白质-DNA相互作用的基础分子机制研究;(3)利用已知的蛋白质-DNA相互作用发展针对目标分子...  相似文献   

5.
Partial-filling affinity capillary electrophoresis (PFACE) is used to examine the binding interactions between two model biological systems: D-Ala-D-Ala terminus peptides to the glycopeptide antibiotic vancomycin (Van) from Streptomyces orientalis, and arylsulfonamides to carbonic anhydrase B (CAB, EC 4.2.1.1, bovine erythrocytes). Using these two systems, modifications in the PFACE technique are demonstrated including flow-through PFACE (FTPFACE), competitive flow-through PFACE (CFTPFACE), on-column ligand synthesis PFACE (OCLSPFACE), and multiple-step ligand injection PFACE (MSLIPFACE). In PFACE small plugs of sample are injected into the capillary column and an equilibrium is established between receptor and ligand during electrophoresis. Binding constants are then obtained by Scatchard analysis using changes in the migration time of the receptor/ligand on changing the concentration of the ligand/receptor. Data demonstrating the quantitative potential of these methods are presented. This review focuses on the unique capabilities of the different PFACE techniques as applied to two model biological systems.  相似文献   

6.
《Electrophoresis》2018,39(4):569-580
A fast and precise affinity capillary electrophoresis (ACE) method has been applied to investigate the interactions between two serum albumins (HSA and BSA) and heparinoids. Furthermore, different free flow electrophoresis methods were developed to separate the species which appears owing to interaction of albumins with pentosan polysulfate sodium (PPS) under different experimental conditions. For ACE experiments, the normalized mobility ratios (∆R/Rf), which provided information about the binding strength and the overall charge of the protein‐ligand complex, were used to evaluate the binding affinities. ACE experiments were performed at two different temperatures (23 and 37°C). Both BSA and HSA interact more strongly with PPS than with unfractionated and low molecular weight heparins. For PPS, the interactions can already be observed at low mg/L concentrations (3 mg/L), and saturation is already obtained at approximately 20 mg/L. Unfractionated heparin showed almost no interactions with BSA at 23°C, but weak interactions at 37°C at higher heparin concentrations. The additional signals also appeared at higher concentrations at 37°C. Nevertheless, in most cases the binding data were similar at both temperatures. Furthermore, HSA showed a characteristic splitting in two peaks especially after interacting with PPS, which is probably attributable to the formation of two species or conformational change of HSA after interacting with PPS. The free flow electrophoresis methods have confirmed and completed the ACE experiments.  相似文献   

7.
Affinity capillary electrophoresis using mobility-shift analysis was utilized to characterize the binding of peptide ligands to cyclophilins, which are members of the enzyme family of peptidyl-prolyl cis/trans isomerases. Peptides derived from the human immunodeficiency virus capsid protein p24 exhibited different affinities to the isoenzymes cyclophilin18 and cyclophilin20. For the interaction of the peptide hormone bradykinin with cyclophilin18, a dissociation constant of 1.4 +/- 0.1 mM was determined. Finally, the affinity of cyclophilin20 to peptides from a cellulose-bound peptide library scanning the sequence of Drosophila melanogaster protein cappuccino was investigated. The affinities of selected peptides to cyclophilin20 and a green fluorescent fusion protein with cyclophilin20 were compared.  相似文献   

8.
Recent advances in affinity capillary electrophoresis   总被引:2,自引:0,他引:2  
Use of the specificity of (bio)interactions can effectively overcome the selectivity limitation faced in capillary electrophoresis (CE), and the resulting technique usually is referred to as affinity capillary electrophoresis (ACE). Despite the high selectivity of ACE, several important problems still need to be addressed. A major issue in all CE separations, including ACE, is the concentration detection limit. Using UV detection, this is usually in the order of 10(-6) M whereas laser-induced fluorescence (LIF) detection can provide detection limits down to the sub-10(-10) M range. However, a marked disadvantage of LIF is that labeling of the analytes is usually required, which might change the interaction behavior of the solutes under investigation. Additionally, labeling reactions at sub-10(-10) M concentration levels are certainly not trivial and often difficult to perform quantitatively. Alternative and universal detection approaches, particularly mass spectrometric (MS) detection, look very promising but (A) CE-MS techniques are still far from routine application. Important future progress in sensitive detection strategies is likely to increase the use of ACE in the future.  相似文献   

9.
A computer-simulated model of affinity capillary electrophoresis is developed. Unlike existing models, it is able to describe the situation where the concentrations of sample molecules and ligand molecules are commensurable, or even the situation where the zones occupied by these molecules are not mixed initially. The model permits to study the dependence of the spatial and temporal distributions of sample molecules on various parameters such as reaction rate constants, concentrations of sample and reagent, electromigration velocities of sample and reagent and sample injection volume. A collection of peak shapes for different values of parameters is presented. The dependence of peak variance on the ratio of the time of analysis to the characteristic time of reaction is studied.  相似文献   

10.
Lagu AL 《Electrophoresis》1999,20(15-16):3145-3155
Capillary electrophoresis (CE)-related techniques are increasingly being used as a matter of routine practice in the biotechnology discipline. Since recombinant DNA-derived proteins and the antisense oligonucleotides constitute a large portion of the applications of these techniques, they have been emphasized in this review. Analyses by CE of Escherichia coli-derived proteins and glycosylated proteins derived from mammalian cell cultures are summarized, as well as those of the carbohydrate chains that have been enzymatically removed from the protein. Applications of CE in the analysis of the antisense oligonucleotides for the determination of purity and the analytical studies on the metabolism of these modified oligonucleotides, by CE are reviewed. The literature mainly covers the period from 1996.  相似文献   

11.
Chemiluminescence detection was used in capillary electrophoresis integrated on a microchip. Quartz microchips have two main channels and four reservoirs. Dansyl-lysine and -glycine were separated and detected with bis[(2-(3,6,9-trioxadecanyloxycarbony)-4-nitrophenyl]oxalate as peroxyoxalate chemiluminescent reagent. These dansyl amino acids came into contact with the chemiluminescence reagent to produce visible light at the interface between the separation channel and chemiluminescence reagent-containing reservoir. The detection limit (S/N = 3) for dansyl-lysine was 1 x 10(-5) M, which corresponded to the very small mass detection limit of ca. 0.4 fmol. However, the concentration sensitivity in the present system was approximately two orders of magnitude lower than that in the conventional capillary electrophoresis-chemiluminescence detection system. The relative standard deviations of migration time and peak height for dansyl-lysine were 4.2 and 4.5%, respectively. A channel conditioning before every run and an appropriate control of voltages were needed for the reproducible results. The present system had advantages in rapid separation time (within 40 s), small (several 10 pI) and accurate sample injection method using a cross-shaped injector, and simplification and miniaturization of the detection device.  相似文献   

12.
Poor sensitivity and low phase ratio are the main drawbacks of open tubular capillary electrochromatography (OTCEC). The poor sensitivity results from the use of narrow bore size capillary, whereas the low phase ratio, which limits the separation capability, is caused by the limited surface area of conventional capillary. Two strategies may be useful to overcome these disadvantages. First, an extended light path (ELP) capillary, which has a bubble cell at the detection point, is used to improve the sensitivity. Secondly, an etched capillary of a 1,000-fold increased surface area is used to enhance the phase ratio. In this work, use of an ELP capillary and an etched capillary in OTCEC was evaluated with a chiral stationary phase of avidin prepared with the physical adsorption method. With a 20 microm I.D. ELP capillary with a 150 microm bubble cell, the peak height was enhanced by 4-10-fold and the corrected peak area was increased by 12-fold relative to a 20 microm I.D. conventional capillary. However, the peak efficiency and resolution decreased noticeably. The phase ratio on the etched capillary was slightly enhanced, by a factor of 1.64 relative to an unetched capillary. Consequently, the separation capability was slightly improved. The increase in the phase ratio was much lower than that expected from the increase in surface area, the reason for which is probably the reduced density of surface silanol group and the generation of nitrogen-containing groups due to the etching process.  相似文献   

13.
Chitosan is a biopolymer of increasing significance, as well as a renewable and sustainable material. Its main molecular characteristics are molar mass and degree of acetylation (composition). Precise average degrees of acetylation were measured by quantitative 1H solution-state NMR spectroscopy. While number-average degrees of acetylation had already been determined by 1H NMR spectroscopy, weight-average degrees of acetylation are also determined and may be more relevant for some properties, such as mechanical properties. We report the first separation of chitosan according to its degree of acetylation using free solution capillary electrophoresis. Capillary electrophoresis separates chitosan in the ‘critical conditions’: the molar mass plays little role and the separation is by the degree of acetylation. It characterises the heterogeneity of chitosan samples in terms of composition (dispersity of the distribution of degrees of acetylation). This heterogeneity (broad distribution of degrees of acetylation) cannot be neglected contrary to a common assumption found in the literature. This fast and easy separation will allow establishing a structure–property relationships.
Figure
Separation of chitosan molecules by their composition with free solution capillary electrophoresis  相似文献   

14.
Capillary zone electrophoresis has been used for the separation of arsenite, arsenate, monomethylarsonic acid (MMA), dimethylarsinic acid (DMA) and phenylarsonic acid. The separation was achieved using a fused silica capillary filled with a phosphate buffer. The on-column U.V. detector was operated at 190 nm. The influence of voltage and injected volume, reproducibility of calibration and recovery from a drinking water sample were studied. Using the calibration plot method and phenylarsonic acid as internal standard the mean recoveries for arsenate, MMA and DMA were 104%, 97% and 97% respectively.  相似文献   

15.
Fluorescence polarization detection for affinity capillary electrophoresis   总被引:1,自引:0,他引:1  
Le XC  Wan QH  Lam MT 《Electrophoresis》2002,23(6):903-908
Affinity capillary electrophoresis (ACE) with laser-induced fluorescence polarization (LIFP) detection is described, with examples of affinity interaction studies. Because fluorescence polarization is sensitive to changes in the rotational motion arising from molecular association or dissociation, ACE-LIFP is capable of providing information on the formation of affinity complexes prior to or during CE separation. Unbound, small fluorescent probes generally have little fluorescence polarization because of rapid rotation of the molecule in solution. When the small fluorescent probe is bound to a larger affinity agent, such as an antibody, the fluorescence polarization (and anisotropy) increases due to slower motion of the much larger complex molecule in the solution. Fluorescence polarization results are obtained by simultaneously measuring fluorescence intensities of vertical and horizontal polarization planes. Applications of CE-LIFP to both strong and weak binding systems are discussed with antibody-antigen and DNA-protein binding as examples. For strong affinity binding, such as between cyclosporine and its antibody, complexes are formed prior to CE-LIFP analysis. For weaker binding, such as between single-stranded DNA and its binding protein, the single-stranded DNA binding protein is added to the CE separation buffer to enhance dynamic formation of affinity complexes. Both fluorescence polarization (and anisotropy) and mobility shift results are complementary and are useful for immunoassays and binding studies.  相似文献   

16.
CE on microchip is an emerging separation technique that has attracted wide attention and gained considerable popularity. Because of miniaturization of the separation format, CE on chip typically offers shorter analysis time and lower reagent consumption with potential development of portable analytical instrumentation. This review with 143 references is focused on proteins and peptides analysis, DNA separation including fragment sizing, genotyping, mutation detection and sequencing, and also the analysis of low-molecular-weight compounds, namely explosive residues and warfare agents, pharmaceuticals and drugs of abuse, and various small molecules in body fluids.  相似文献   

17.
To facilitate the implementation of affinity capillary electrophoresis into routine binding screening studies of proteins with metal ions, method acceleration, transfer and precision improvement were investigated. Affinity capillary electrophoresis was accelerated by using shorter capillaries, employing lower sample concentrations and smaller injection volumes. Intra‐ and inter‐instrument method transfers were investigated considering the temperature setting of the capillary cooling system. For intra‐instrument method transfer, similar results were obtained when transferring a method from a long (62 cm) to a short (31 cm) capillary. The analysis time was reduced from 9 to 4 min. In case of inter‐instrument method transfer, interaction results showed small variation on the capillary electrophoresis instrument with inefficient capillary cooling system. Binding measurement precision was enhanced by slightly pushing the sample above the beginning of the capillary. Changing the buffer vials after each 30 runs and employing extra flushing after each 60 subsequent runs further enhanced the precision. The use of 0.1 molar ethylenediaminetetraacetic acid in the rinsing solution successfully desorbs the remaining metal ions from the capillary wall. Excellent precision for apparent mobility ratio measurements was achieved for different protein–metal ion interactions (relative standard deviation of 0.16–0.89%, 15 series, 12 runs for each).  相似文献   

18.
Many analytical approaches are available to evaluate (bio)molecular interactions, all of which have their particular advantages and disadvantages. In recent years, two relatively new techniques have emerged that may be used by the bioanalytical community to evaluate such interactions, namely affinity capillary electrophoresis (ACE) and bioaffinity electrospray ionization-mass spectrometry (ESI-MS). In this paper, we describe and evaluate the use of both these techniques for the investigation of the interactions of glycopeptide antibiotics with peptides that mimic the bacterial cell wall binding site. We focus particularly on the effect of the sugar moieties attached to the antibiotic peptide backbone and on the noncovalent dimerization of these glycopeptide antibiotics.  相似文献   

19.
This review discusses selected aspects of selector-select and interactions in chiral capillary electrophoresis (CE). Studies performed using nuclear magnetic resonance (NMR) spectroscopy, mass spectrometry (MS) and X-ray crystallography for a better understanding of chiral recognition mechanisms in CE are summarized. The theoretical background of chiral CE in general, mathematical models, method development and optimization strategies, etc., are not covered. A general overview on the most recent developments in chiral CE is presented in this volume in the review paper by Bocek [1].  相似文献   

20.
In contrast to α-, β- and γ-cyclodextrins, little information is available on the isolation and separation of cycloamylose (CA) with degree of polymerization (DP) larger than 22. The objective of the current study was to develop a new iodine affinity capillary electrophoresis (CE) for separation of CA with DP of 22-42, which was based on the formation of CA-iodine inclusion complexes, CA with twisted conformations made complicated mobility behaviors on CE instead of merely size dependent. The influences of iodide/iodine ratio, iodine concentration, pH, ion strength of running phosphate buffer, voltage, and temperature on the peak resolution and electrophoretic mobility were further investigated. Our results suggest that iodine affinity capillary electrophoresis provides a versatile and selective tool for the isolation and analysis of CA with DP from 22 to 42.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号