首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Complexation of aluminium(III) with the fluorogenic ligand chromotropic acid (4,5-dihydroxynaphthalene-2,7-disulfonic acid) has been revisited with the aim of using enhancement of the fluorescence intensity as an analytical tool. Complexation at the optimum pH4 was shown to lead to a 1:1 complex with a stability constant log 110=18.4±0.7. The fluorogenic effect was thoroughly investigated. Nearly selective excitation of the chelate rather than the ligand could be achieved at wavelengths longer than 360 nm. For analytical purposes the main interfering ion was Ga3+. The strongest competing ligand was shown to be citric acid. Competitive complexation by acetate or formate ions can also make their use in a buffer at the usual concentration, 0.2 mol L–1, questionable, whereas a 10–2 mol L–1 formic acid buffer was shown to be a good alternative. The calibration plot showed that the dependence of response on Al(III) concentration was linear up to 500 g L–1; the detection limit was 0.65 g L–1 (3SD blank, n=10, SD=±1.4% at 10 g L–1 and ±0.8% at 100 g L–1). The analytical procedure was successfully applied to several samples of tap water and the results were in good agreement with those from AAS determination.  相似文献   

2.
Procedures for trace cobalt determinations by adsorptive stripping voltammetry at in situ and ex situ plated bismuth film electrodes are presented. These exploit the enhancement of the cobalt peak obtained by using the Co(II)–dimethylglyoxime–cetyltrimethylammonium bromide–piperazine-N,N-bis(2-ethanesulfonic acid) system. The calibration graph for an accumulation time of 120 s was linear from 2 × 10–10 to 2 × 10–8 mol L–1. The relative standard deviation from five determinations of cobalt at a concentration of 5 × 10–9 mol L–1 was 5.2%. The detection limit for an accumulation time of 300 s was 1.8 × 10–11 mol L–1. The proposed procedure was applied to cobalt determination in certified reference materials and in tap and river water samples.  相似文献   

3.
In this study, UV–visible spectrophotometry (UV–Vis) and high-performance liquid chromatography (HPLC) were used for simultaneous analysis of chelating agents diethylenetriamine pentaacetic acid (DTPA), ethylenediamine tetraacetic acid (EDTA), and nitrilotriacetic acid (NTA), as their metal chelates in dishwashing detergents, natural waters, and pulp mill water. The total amounts of the chelating agents in dishwashing detergents were verified by potentiometric titration with Fe(III) solution. Nickel(II) chelates were determined by UV–Vis and iron(III)chelates by HPLC and titration. Recoveries of DTPA, EDTA, and NTA from a standard mixture of analytes by UV–Vis were 107±7, 101±12 and 94±13%, respectively, and the recovery of the total amount of complexing agents was 99±4%. The limits of detection for DTPA, EDTA, and NTA were 667, 324, and 739 mol L–1, respectively. In HPLC measurements the optimized mobile phase contained 0.03 mol L–1 sodium acetate, 0.002 mol L–1 tetrabutylammonium bromide, and 5% methanol at pH 3.15 and the detection was by UV–Vis detection at 254 nm. All three complexing agents could be separated from each other in a simultaneous analysis in less than 5 min. The limits of detection were 0.34, 0.27, and 0.62 mol L–1 for DTPA, EDTA, and NTA, respectively. The total amounts of the analytes measured in the dishwashing detergents by the three techniques were found to be highly comparable (ANOVA: F=0.04, P=0.96). R2 values were 0.99 for EDTA, 0.99 for NTA, and 0.99 for all the results when UV–Vis and HPLC determinations were compared using regression lines. The UV–Vis and HPLC methods were proved to be viable also for analyses of natural and pulp mill waters. The absence of matrix interferences was verified by the standard addition technique.  相似文献   

4.
Summary The kinetics of formation and dissociation of the binuclear complex of Be2+ with 3-nitrosalicylatopentaamminecobalt(III) have been investigated in the 20–40 and 25–40 °C ranges (I = 0.3 mol dm –3), respectively. At 25 °C the rate and activation parameters for the formation of the binuclear species are: k f = 26.9 × 102 dm3mol–1s–1, H = 104 ± 7kJ mol–1 S = 91 ± 22JK–1mor–1.The rate constant, activation enthalpy and activation entropy for the acid-catalysed dissociation of the binuclear species are: 1.25 ± 0.08dm3mol –1 at 25 °C, 53 ± 3kJ mol–1 and - 67 ± 9 J K –1 mol–1, respectively. The formation of the binuclear species is chelation controlled while the dechelation is acid catalysed.  相似文献   

5.
Precise and accurate determination of hexavalent chromium in different types of solid environmental sample is regarded as a technical challenge with significant potential error if historically accepted methods are used. Microwave-assisted alkaline extraction (0.5 mol L–1 NaOH+0.28 mol L–1 Na2CO3) followed by anion-exchange chromatographic separation and inductively coupled plasma mass spectrophotometric detection has been shown to provide accurate and precise results. To obtain a better understanding of potential species conversion during and/or after extraction steps, speciated isotope-dilution mass spectrometry (SIDMS) (EPA Method 6800) metrology has been successfully applied as a diagnostic tool with the modified accompanying extraction version of EPA Method 3060A. In our study, aggregate materials distributed over a large area of a major western US state were found to contain a high concentration of total chromium (195±13 to 709±19 g g–1) and significant amounts of Cr6+ (141±6 to 341±29 g g–1) which are at least three orders of magnitude higher than the US EPA threshold limit (0.5 g g–1). Sediment samples from a major western US state, studied independently, were found to contain less (1.77±0.34 g g–1) or no Cr6+ in the presence of significant total chromium.  相似文献   

6.
The regularities of vapor-phase nitration of cellulose with HNO3 under conditions of natural convection and hindered heat removal in the absence of air were studied using the nonisothermal kinetic method. It was established that the nitration rate at the depth of conversion of 0.08 to 0.7 is described by the kinetic law d/dt =k 1 p/(1+), wherek 1 = 104.49±0.6 exp(–A/RT) s–1 atm–1, = 10–35.5±15.7exp(B/RT),A = 36.6±3.8 kl mol–1, andB = 203±88 kJ mol–1. The diffusion mechanism of vapor-phase nitration of cellulose, which explains the high value of activation energies, is discussed. The effective diffusion coefficient of HNO3 in cellulose at 25 °3.7 · 10–7 cm2 s–1) and the activation energy of diffusion (38.3±4.2 kJ mol–1) were estimated.For Part 1, see Ref. l.Translated fromIzvestiya Akademii Nauk. Seriya Khimicheskaya, No. 8, pp. 1981–1985, August, 1996.  相似文献   

7.
A rapid high-performance liquid chromatography (HPLC) method using a monolithic column with UV detection at 238 nm was developed for the determination of fenpropathrin, betacyfluthrin, deltamethrin, and permethrin (cis and trans isomers) in whole urine. The method is based on the use of a monolithic chromatographic column and a restricted access material (RAM) cartridge for sample preparation. The mobile phase was water/acetonitrile (42:58 v/v), the flow rate was 3 mL min–1, and chromatographic separation was carried out in 10 min. The separation of cis and trans isomers of permethrin was also possible under the above-mentioned conditions. Detection limits in reconstituted whole urine samples were between 0.9 g L–1 for betacyfluthrin and 4.4 g L–1 for fenpropathrin and trans-permethrin. Recoveries for urine samples spiked with different amounts of pyrethroids (between 19 g L–1 and 75 g L–1) were in the 70±6 to 90±7% range.  相似文献   

8.
New books     
Summary Micromolar analyses of the nitrogen species NH3, NO 2 , and NO 3 in soil and other samples are usually accomplished by extracting several samples and testing each for a different species. This procedure is not viable when the quantity of the initial sample is limited. An improved method of separating and analysing for ammonia NH3(aq), nitrite NO 2 (aq), and nitrate NO 3 (aq) from a single small sample with concentrations of 0–50 mol/l is reported. No interferences or carryovers among the three nitrogen containing species were found. Uncertainties were ±2–5 mol/l and accuracies with respect to standards were ±3 mol/l.  相似文献   

9.
The first and second molal dissociation quotients of malonic acid were measured potentiometrically in a concentration cell fitted with hydrogen electrodes. The hydrogen ion molality of malonic acid/bimalonate solutions was measured relative to a standard aqueous HCl solution from 0 to 100°C over 25° intervals at five ionic strengths ranging from 0.1 to 5.0 molal (NaCl). The molal dissociation quotients and available literature data were treated in the all anionic form by a seven-term equation. This treatment yielded the following thermodynamic quantities for the first acid dissociation equilibrium at 25°C: logK 1a =-2.852±0.003, H 1a /o =0.1±0.3 kJ-mol–1, S 1a o =–54.4±1.0 J-mol–1-K–1, and C p,1a o =–185±20 J-mol–1-K–1. Measurements of the bimalonate/malonate system were made over the same intervals of temperature and ionic strength. A similar regression of the present and previously published equilibrium quotients using a seven-term equation yielded the following values for the second acid dissociation equilibrium at 25°C: logK2a=–5.697±0.001, H 2a o =–5.13±0.11 kJ-mol–1, S 2a o =–126.3±0.4 J-mol–1-K–1, and C p,2a o =–250+10 J-mol–1-K–1.Presented at the Second International Symposium on Chemistry in High Temperature Water, Provo, UT, August 1991.  相似文献   

10.
The products of ascorbic acid oxidation in the presence of cobalt octa-4,5-carboxy-phthalocyanine sodium salt (TPH) were identified. These include the ascorbate radical (A·), hydroxyl radical (OH·), and hydrogen peroxide (H2O2). The kinetics of accumulation and consumption of the reaction products was studied. For the concentration ranges of ascorbic acid = 0–2.5 ⋅ 10−3 mol L−1 and the catalyst C TPH = 0–3.5 ⋅ 10−5 mol L−1, the the highest possible concentration of the ascorbate radical is ∼10−7 mol L−1, the concentration of H2O2 is 7 ⋅ 10−4 (30% of the starting concentration of ascorbic acid) and the concentration of the hydroxyl radical is at most 10−6 mol L−1.__________Published in Russian in Izvestiya Akademii Nauk. Seriya Khimicheskaya, No. 10, pp. 2224–2228, October, 2004.  相似文献   

11.
A potentiometric ion-selective electrode based on new compound, as a carrier, has been successfully developed for detection of perchlorate anion in aqueous solution. Within the perchlorate ion concentration range 1.0×10–6 to 1.0 mol L–1 the electrode had a linear response with a Nernstian slope of 60.6±1.0 mV per decade . The limit of detection as determined from the intersection of the extrapolated linear segments of the calibration plot was 8.0×10–7 mol L–1. The proposed electrode has fairly a good discriminating ability towards ClO4 ion in comparison to other anions. The sensor has a response time of 10 s and can be used for at least 2 months without substantial divergence in potential. It was successfully applied to direct determination of perchlorate in urine and water.  相似文献   

12.
The mechanism of the radiation-induced conversion of ammonia to nitrites and nitrates in aerated aqueous solutions has been studied. The formation of the pernitrite ion, O=N-O-O, was detected at pH 10.5. The kinetics of its formation and decay were studied, andk form was estimated at (2.3±0.2)·107 L mol–1 s–1. The course of decay obeys first-order kinetics; the rate constant decreases at higher pH. Radiochemical yields of pernitrite, nitrite and nitrate at various pH and initial NH3 concentrations were determined. A mechanism of ammonia oxidation in aqueous solution is proposed.Translated fromIzyestiya Akademii Nauk. Seriya Khimicheskaya, No. 2, pp. 280–283, February, 1993.  相似文献   

13.
This work describes an electroanalytical investigation of dopamine using cyclic voltammetry (CV) and the graphite–polyurethane composite electrode (GPU). In CV studies, well-defined redox peaks characterize the oxidation process at the GPU electrode, which is indicative of electrocatalytic effects associated with active sites on the GPU electrode surface. A new analytical methodology was developed using the GPU electrode and square wave voltammetry (SWV) in BR buffer solution (0.1 mol L–1; pH 7.4). Analytical curves were constructed under optimized conditions (f=60s–1, Ea=50 mV, EI=2 mV) and detection and quantification limits of 6.4×10–8 mol L–1 (12.1 g L–1) and 5.2×10–6 mol L–1 (0.9 mg L–1), respectively, were achieved. The precision of the method was checked by performing ten successive measurements for a 9.9×10–6 mol L–1 dopamine solution. For intra-assay and inter-assay precisions, the relative standard deviations were 1.9 and 2.3%, respectively. In order to evaluate the developed methodology, the determination of dopamine was performed with good sensitivity and selectivity, without the interference of ascorbic acid in synthetic cerebrospinal fluid, which indicates that the new methodology enables reliable analysis of dopamine.  相似文献   

14.
A rapid and sensitive method was developed to determine, with a single dilution, the concentration of 33 major and trace elements (Na, Mg, Si, K, Ca, Li, Al, P, S, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Sr, Mo, Cd, In, Sn, Sb, Cs, Ba, Re, Hg, Pb, Bi, U) in groundwater. The method relies on high-resolution inductively coupled plasma mass spectrometry (HR ICP-MS) and works across nine orders of magnitude of concentrations. For most elements, detection limits for this method are considerably lower than methods based on quadrupole ICP-MS. Precision was within or close to ±3% (1) for all elements analyzed, with the exception of Se (±10%) and Al (±6%). The usefulness of the method is demonstrated with a set of 629 groundwater samples collected from tube wells in Bangladesh (Northeast Araiharzar). The results show that a majority of tube well samples in this area exceed the WHO guideline for As of 10 g L–1, and that those As-safe wells frequently do not meet the guideline for Mn of 500 µg L–1 and U of 2 µg L–1.  相似文献   

15.
A new, simple, sensitive and selective fluorometric method for the determination of nitrite has been developed. The reaction of nitrite with hydralazine in acidic medium, heated on a boiling water-bath for 15 min, produced a tetrazolo (5,1-a) phthalazine (Tetra-P). The product formed was measured at ex = 274 nm and em = 345 nm. The fluorescence intensity was valid over a nitrite concentration range 0.067–60.3 ng mL–1, with a detection limit of 0.0091 ng mL–1. The reproducibility of the proposed method was determined by running a different concentration of nitrite, 13.4, 33.5, and 46.9 ng mL–1. The % recoveries and the relative standard deviations were found to be 100.6 ± 0.9, 99.9 ± 0.5, and 99.4 ± 1.1%, respectively. The proposed method was applied successfully to the determination of nitrogen dioxide sampled from the atmosphere using the liquid droplet method. The nitrogen dioxide our wind tunnel was controlled by an NO x analyzer based on a chemiluminescence analyzer detector (CLAD 1000). A linear graph was obtained for the nitrogen dioxide in the wind tunnel vs. NO2 sampled by the liquid droplet method. The effect of interference substances in the determination showed that cations and anions did not disturb the process. The results obtained were satisfactory when compared with the reference method.  相似文献   

16.
A method involving solid-phase micro extraction (SPME) and gas chromatography with electron capture detection (SPME–GC–ECD) has been optimised for identification and quantification of 2,4,6-trichloroanisole (TCA) at ng L–1 concentrations in disinfected (chlorinated) water samples. A central composite design was used for factorial analysis of four factors, three factors related to the SPME (PDMS fibre) procedure (adsorption time, temperature of the sample during headspace sampling, and desorption time) and one related to the GC operation (the rate of increase of the temperature of the GC oven). Good linearity (linear correlation coefficient greater than 0.999) was observed for TCA concentrations up to 50 ng L–1, limits of detection and quantification of 0.7 and 2.3 ng L–1, respectively, and good precision (relative standard deviation 2.8% and 3.4% for 5 and 30 ng L–1 of TCA, respectively). Besides TCA, this system also enables the detection and quantification of the four trihalomethanes in the g L–1 concentration range with limits of detection and quantification of approximately 0.3 g L–1 and 1 g L–1, respectively.  相似文献   

17.
The aim of the study was to develop an inductively coupled plasma mass spectrometry (ICPMS) method for robust and simple routine determination of selenium in serum. Polyatomic interferences on 76Se, 77Se, and 78Se were removed by applying an octopole reaction system ICPMS with the reaction cell pressurized with H2 gas. We developed a novel simple optimization routine for the H2 gas flow based on a signal-to-noise ratio (SNR) calculation of the selenium signal measured in a single selenium standard. The optimum H2 flow was 2.9 mL min–1. The selenium content in serum was determined after a 50-fold dilution with 0.16 M HNO3 and quantified by using addition calibration and gallium as an internal standard. The method detection limit was 0.10 g L–1 for 76Se and 78Se and 0.13 g L–1 for 77Se. Human serum samples from a case-control study investigating if selenium was associated with risk of colorectal adenoma were analyzed. The average selenium concentration for the control group (n=768) was 137.1 g L–1 and the range was 73.4–305.5 g L–1. The within-batch repeatability (a batch is ten samples) estimated from 182 replicate analyses was 6.3% coefficient of variation (CV), whereas the between-batch repeatability was 7.4% CV estimated from 361 replicates between batches. The method accuracy was evaluated by analysis of a human serum certified reference material (Seronorm Serum level II, Sero A/S, Norway). There was a fairly good agreement between the measured average of 145±3 g L–1 (n=36) and the certified value of 136±9 g L–1. In addition the method was successfully applied for analysis of zinc serum concentrations without further optimization. For the Seronorm certified reference material a value of 911±75 g L–1 (n=31) for zinc was obtained, which corresponds well to the certified zinc value of 920±60 g L–1.  相似文献   

18.
The first and second molal dissociation quotients of oxalic acid were measured potentiometrically in a concentration cell fitted with hydrogen electrodes. The emf of oxalic acid-bioxalate solutions was measured relative to an HCl standard solution from 25 to 125°C over 25o intervals at nine ionic strengths ranging from 0.1 to 5.0 molal (NaCl). The molal dissociation quotients and available literature data were treated in the all anionic form by a five-term equation that yielded the following thermodynamic quantities at infinite dilution and 25°C: logK1a=–1.277±0.010, H 1a o =–4.1±1.1 kJ-mol–1, S 1a o =38±4 J-K–1-mol–1, and C p,1a o =–168±41 J-K–1-mol–1. Similar measurements of the bioxalate-oxalate system were made at 25o intervals from 0 to 175°C at seven ionic strengths from 0.1 to 5.0m. A similar regression of the experimentally-derived and published equilibrium quotients using a seven-term equation yielded the following values at infinite dilution and 25°C: logK2a=–4.275±0.006, H 2a o =–6.8±0.5 kJ-mol–1, S 2a o =–105±2 J-K–1-mol–1, and C p,2a o =–261±12 J-K–1-mol–1.  相似文献   

19.
A method for sensitive determination of the anti-cancer agent oxaliplatin in human plasma and human plasma ultrafiltrate (pUF) is presented. The method is based on the quantification of platinum by graphite-furnace atomic-absorption spectrometry, with Zeeman correction and an atomisation temperature of 2,700°C. Sample pretreatment involves dilution of the samples with a solution containing 0.15 mol L–1 NaCl and 0.20 mol L–1 HCl in water. Validation was performed in accordance with the most recent FDA guidelines for bioanalytical method validation. All results were within requirements. The validated ranges of quantification were 0.10–400 mol L–1 for human pUF and 0.50–400 mol L–1 for plasma. The assay is now successfully used to support pharmacokinetic studies of cancer patients treated with oxaliplatin.  相似文献   

20.
A reliable and reproducible method, capillary zone electrophoresis with amperometric detection (CZE–AD), has been developed for separation and quantification of levodopa methyl ester (LDME) and its biotransformation products levodopa (L-DOPA) and dopamine (DA) in rat serum. A carbon-disk electrode was used as working electrode. The optimum conditions for CZE detection were 50 mmol L–1 phosphate solution at pH 7.0 as running buffer, 17 kV as separation voltage, 1.0 V (vs Ag/AgCl, 3.0 mol L–1) as detection potential, and sample injection for 8 s at 17 kV. The linear ranges were from 2.4×10–2 to 2.2 g mL–1 for LDME, 2.9×10–1 to 49.5 g mL–1 for L-DOPA, and 1.4×10–2 to 1.5 g mL–1 for DA with correlation coefficients of 0.9997, 0.9994, and 0.9999, respectively. The detection limits for LDME, L-DOPA, and DA were 14.6, 98.0, and 9.7 ng mL–1, respectively. Recoveries were 80.3% for LDME, 93.5% for L-DOPA, and 86.5% for DA. This method was applied to serum samples after intravenous injection of LDME and L-DOPA to rats.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号