首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
We present a sensitive method for simultaneous determination of bisphenol A (BPA), benzophenone-3 (BP-3), 4-tert-octylphenol (t-OP), ortho-phenylphenol (OPP), four parabens (methyl, ethyl, propyl, butyl parabens) and five chlorophenols (2,4-dichlorophenol (2,4-DCP), 2,5-dichlorophenol (2,5-DCP), 2,4,5-trichlorophenol (2,4,5-triclorophenol), 2,4,6-trichlorophenol (2,4,6-TCP), and triclosan (TCS)), in human urine by high-pressure liquid chromatography (HPLC) mass spectrometry (MS). Samples were processed using enzymatic deconjugation of glucuronides followed by solid phase extraction (SPE) on a C18 cartridge and the eluate was concentrated. Analytes were separated by reversed-phase HPLC and then detected by atmospheric pressure chemical ionisation (APCI) MS and quantified by isotope dilution method. We describe details for optimisation of each step of the procedure. The sample treatment steps are straightforward and not labour-intensive and, therefore, permit a high sample throughput with excellent prospects for automation. This method shows low inter-day variation, and detection limits for most of the compounds are below 1 ng/mL in 1 mL of urine. The method accuracy was also verified by the analysis of proficiency testing urine samples.  相似文献   

3.
4.
In this study, we established a method for simultaneously determining twelve biogenic amines in serum by using reversed phase high performance liquid chromatography (RP-HPLC). The biogenic amines were first extracted from human serum by perchloric acid solution and derivatized by dansyl chloride. An ODS column was selected as separation column at 40 °C. The mobile phase solutions were consisted of A, 0.1 mol/L ammonium acetate and B, acetonitrile. A gradient elution was carried out with a flow rate at 1.0 ml/ml. The results show that the detection limit for twelve biogenic amines ranged between 0.0621 and 0.628 μg/L. All the correlation coefficients were above 0.999. The linearity was over the range from 0.001 to 20 mg/L depending on individual biogenic amine. The intra-day and inter-day coefficients of variations were from 0.53% to 7.50%,and from 1.10% to 7.25% respectively. The average analytical recovery in serum was from 92.02% to 107.65%. Moreover, the serum concentrations of tryptamine, tyramine and histamine in healthy females were found lower than that in healthy males significantly. The method is sensitive, convenient, and reliable, and suitable for simultaneous analysis of multiple biogenic amines in the clinical diagnosis and drug discovery.  相似文献   

5.
A new simple cloud point extraction/preconcentration method was developed for the HPLCMS/MS determination of disulfiram in synthetic urine. Some parameters with an effect on the extraction, such as the concentration of Triton X-114, pH influence, incubation time, equilibration temperature and centrifuging parameters, were studied and optimised. The method proposed for the HPLC-MS/MS determination of disulfiram in synthetic urine with preliminary cloud point extraction was validated. The calibration curve was linear in the range of 0.025–15.4 ng mL?1. The limits of detection (3σ) and quantification (10σ) were 0.008 ng mL?1 and 0.025 ng mL?1, respectively. The matrix effect (96 %), recovery of the extraction procedure (95 %) and overall “process efficiency” (91 %) were also estimated. The results show that the sensitivity, metrological characteristics, ecological safety, simplicity and convenience of the suggested procedure exceed its analogues based on extraction using organic solvents.  相似文献   

6.
A liquid chromatographic (LC) derivatization method for simple and selective determination of catecholamines and indoleamines in human urine has been developed. This method uses "fluorous interaction" in which perfluoroalkyl compounds show affinity with each other. The amino groups of native fluorescent analytes are precolumn derivatized with a non-fluorescent fluorous isocyanate, 2-(perfluorooctyl)ethyl isocyanate, and the fluorous-labeled analytes are retained in the fluorous LC column, whereas underivatized substances are not. Only the retained fluorous-fluorescent analytes are detected fluorometrically at appropriate retention times, and retained amines without fluorophores are not detected. In this study, 3,4-dihydroxyphenylalanine, dopamine, norepinephrine, epinephrine, and metanephrine were used as the representative of catecholamines. Tryptophan, 5-hydroxytryptophan, and 5-hydroxytryptamine were used as the representative indoleamines. This method was applied to determine eight biogenic amines in urine from healthy humans. The fluorous-labeled amines could be separated by fluorous LC column under conditions of isocratic elution within 35 min and simultaneously determined without interference from contaminants in biological samples. The detection limits for eight biogenic amines were 31-640 fmol on column. Calibration curves of them were linear over the range of at least 10-100 nmol/mL urine (r2 > 0.9989) with good repeatability.  相似文献   

7.
液相色谱-串联质谱法同时检测饲料中多种抗氧化剂   总被引:1,自引:0,他引:1  
饲料中添加抗氧化剂能够阻止或延缓饲料中某些营养物质氧化,延长饲料贮存期,从而提高饲料利用率.  相似文献   

8.
采用液相色谱-质谱联用法建立了同时测定化妆品中14种禁用着色剂(吖啶黄、酸性紫49、溶剂红49、溶剂蓝35、氯化四甲基副玫瑰苯胺、氯化五甲基副玫瑰苯胺、氯化六甲基副玫瑰苯胺、颜料橙5、颜料红53、苏丹红Ⅰ、苏丹红Ⅱ、苏丹红Ⅳ、罗丹明B、分散黄3)的分析方法。待测样品经四氢呋喃分散,并对目标物进行提取后,用含有醋酸铵的甲醇-水混合溶液将基质析出,提取液离心过滤后,以10 mmol/L醋酸铵-乙腈作为流动相在Agilent poroshell 120 EC-C18(2.7μm,3.0 mm×50 mm)色谱柱上梯度洗脱进行分离,以色谱峰的峰面积用标准曲线外标法进行定量。在优化条件下,各目标物的线性范围为0.01~1.0μg/m L,相关系数均大于0.999。14种禁用着色剂的定量下限为0.05~0.5μg/g。在低、中、高3个加标水平下,各目标物的回收率为85.4%~106.3%,相对标准偏差(RSD)均低于10%。方法准确、简便、灵敏、可靠,可用于化妆品中此14种禁用着色剂的定量测定。  相似文献   

9.
建立了利用淋洗液自动发生梯度淋洗的离子交换色谱法同时测定水产品中酪胺、5-羟色胺、腐胺、尸胺、组胺、庚二胺、苯乙胺、亚精胺、精胺、色胺等10种生物胺的方法。样品经处理后用Ionpac CS17分离柱和Ionpac CG17型保护柱分离,以EG40自动淋洗液发生器生成的5.0~55 mmol/L的MSA为淋洗液梯度洗脱,脉冲积分安培检测器检测。对梯度进行优化,10种生物胺都能基线分离,并且浓度和峰面积在一定范围内呈良好的线性关系。检出限在0.04 mg/kg以下,回收率在91.2%~102.5%之间,样品的RSD(n=6)小于5%。方法可用于水产品的检测。  相似文献   

10.
11.
建立了液相色谱串联质谱(HPLC-MS/MS)同时对蜂蜜中链霉素和双氢链霉素残留量进行分析的方法。采用磷酸溶液提取,苯磺酸固相萃取柱和C18固相萃取柱串联净化,液相色谱串联质谱测定。链霉素的检出限为0.002 mg/kg,线性范围为0.005~0.100 mg/kg,相关系数为0.9992;双氢链霉素检出限为0.001mg/kg,线性范围为0.002~0.050 mg/kg,相关系数为0.9924。方法回收率为78%~95%,相对标准偏差为2.6%~4.9%。该法实用、准确、快捷,可应用于蜂蜜样品中链霉素和双氢链霉素的同时检测。  相似文献   

12.
An analytical procedure for the simultaneous determination in human serum of 43 common drugs of abuse and their metabolites belonging to the different chemical and toxicological classes of amphetamines, benzodiazepines, dibenzazepines, cocaine, lysergic acid diethylamide, opioids, phencyclidine, tricyclic antidepressants, and zolpidem, using 33 deuterated standards, is presented. The sample treatment was developed to be a very simple protein precipitation and filtration. All analyses were performed with a high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry in positive ionization mode. All analytes were calibrated up to 550 μg/L. The limit of detection ranged from 0.6 ng/mL (EDDP) to 13.7 ng/mL (flunitrazepam). The method has been validated according to the guidelines of the Gesellschaft für Toxikologische und Forensische Chemie, using three multiple reaction mode (MRM) transitions and retention time for positive compound identification, instead of two MRMs, in anticipation of the new guidelines for January 2011.  相似文献   

13.
A reliable method was proposed for the simultaneous determination of five fluoroquinolones (FQs) and two tetracyclines (TCs) in sewage sludge using ultrasonic-assisted extraction (USE) followed by SPE cleanup and high-performance liquid chromatography-mass spectrometry (HPLC-MS)/MS analysis with electrospray ionisation (ESI) in a positive mode. The USE conditions (e.g. extraction solvent, pH, and extraction cycles) and high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) parameters were optimised. Quantification was performed by internal standard calibration in multiple reaction monitoring mode. Recoveries of the antibacterials ranged from 41 to 123%, with relative standard deviations within 17%. The sample-based limits of quantification were 10–63?ng?g?1 dry weight (dw) for FQs (ciprofloxacin, enrofloxacin, lomefloxacin, norfloxacin, and ofloxacin) and 250–500?ng?g?1 dw for TCs (tetracycline and oxytetracycline). The method was applied to determine the antibacterials in sewage sludge and sediment samples were collected from the Pearl River Delta, China. Ciprofloxacin, norfloxacin, and ofloxacin were frequently detected, ranging from 1052 to 17740?ng?g?1 dw in dewatered sludge samples, 585–3545?ng?g?1 dw in untreated solids, and 98–258?ng?g?1 dw in an urban stream sediment sample, respectively. Lomefloxacin and enrofloxacin were also occasionally detected.  相似文献   

14.
In order to monitor biogenic amines in human urine, a method based on field‐amplified sample injection combined with capillary electrophoresis and direct UV absorption detection was developed. Dopamine, tyramine, tryptamine, serotonin and epinephrine were effectively separated and identified in human urine samples, and detection limits were 0.072, 0.010, 0.027, 0.010 and 0.120 µmol/L, respectively. Detection limits comparable to laser‐induced fluorescence detection or solid phase extraction combined with capillary electrophoresis were achieved. Parameters affecting electrophoretic system detection sensitivity were investigated. Optimal separation conditions were obtained using as background electrolyte a pH 6.5 mixture of 2‐(morpholino)ethanesulfonic acid 20 mmol/L and 30 mmol/L phosphate buffer, containing 0.05% hydroxypropylcellulose and 10% v/v methanol. Injections of the sample solution were performed by applying a voltage of 12 kV for 50 s. Recovery and accuracy ranged between 89.4 and 94.9%, and 89 and 112%, respectively. The method was successfully applied on actual urine samples (from a healthy volunteer): target bioamine content was consistent with endogenous levels reported in the literature. The proposed method is simple, fast and inexpensive and can be conveniently employed in work‐related stress studies. The affordability and noninvasive sampling of the method allow epidemiological studies on large number of exposed persons to be performed. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

15.
Qualitative screening procedures have been developed for the rapid detection and identification of the metabolites of nerve agents in the urine samples and extracts using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The combination of negative electrospray ionization (ESI) using a C18 column and water-methanol mobile phase modified with ammonium formate provides a rapid screening procedure for nerve agent degradation products with limit of detection of 1 ng/mL in the precursor-ion analysis. Also, determination of the alkyl methylphosphonic acids was carried out by the SRM scan mode with the limit of detection of 0.1 ng/mL. These procedures will be applicable to the trace analysis of metabolites of nerve agents in human urine matrices in the Organisation for the Prohibition of Chemical Weapons (OPCW) proficiency test.  相似文献   

16.
HPLC-MS法同时测定5种抗癫痫药的血药浓度   总被引:1,自引:0,他引:1  
癫痫是神经系统的一种常见病,不少患者需长期同时服用两种或两种以上抗癫痫药物.本研究采用高效液相色谱-电喷雾离子化质谱法同时测定5种常用抗癫痫药物卡马西平、氯硝西泮、阿普唑仑、艾司唑仑和苯妥英钠的血药浓度,色谱条件为以地西泮作为内标,Zorbax SB-C18(30mm×2.1mm,3.5μm)为色谱柱,甲醇-25mM的乙酸铵水溶液梯度洗脱,样品采用无水乙醚萃取.样品分析以离子阱质谱作为检测器,采用多重反应监测模式(MRM),选择MS2离子提高方法的专属性,5种抗癫痫药物在50~5000ng/mL浓度范围内均具有良好的线性关系,其日内、日间精密度均小于10%,方法回收率均大于90%.研究表明,本方法专属性强,灵敏度高,线性关系良好,适用于这5种抗癫痫药物的血药浓度监测、个体化给药方案的制定、药物滥用监测以及药代动力学研究.关键词高效液相色谱质谱抗癫痫药血药浓度药物分析  相似文献   

17.
高效液相色谱-串联质谱法检测人血液中常见毒品残留量   总被引:2,自引:0,他引:2  
对人血液中鸦片类、苯丙胺类、可卡因类等26种毒品的提取方法、净化方法、色谱条件及质谱条件进行了研究,建立了液相色谱-串联质谱法检测人血液中26种常见毒品的检测方法.方法检测限为1~2 μg/kg.在2~200μg/kg范围内,相关系数为0.9771 ~0.9995.在5~50 μg/kg范围内,26种常见毒品的回收率在...  相似文献   

18.
海河底泥中12种抗生素残留的液相色谱串联质谱同时检测   总被引:5,自引:0,他引:5  
建立了同时检测河流底泥中12种抗生素(4种磺胺类、3种喹诺酮类、2种四环素类、2种大环内酯类、甲氧苄啶)残留的高效液相色谱串联质谱检测方法(HPLC-MS/MS)。样品提取过程中以NaF为离子交换剂,经2种提取液逐次提取,合并提取液,正己烷脱脂,萃取物经SAX-HLB固相萃取系统净化浓缩,氮吹,定容。以乙腈和0.3%甲酸为流动相,采用梯度洗脱进行液相色谱分离,以Simatone为内标物,用质谱检测器进行定性和定量分析。12种目标物的检出限为1.0~5.0 ng/g,回收率为65%~91%,相对标准偏差为0.6%~5.1%(n=4)。  相似文献   

19.
Calcineurin inhibitor nephrotoxicity, especially for the widely used tacrolimus, has become a major concern in post‐transplant immunosuppression. Multiparametric amino acid metabolomics is useful for biomarker identification of tacrolimus nephrotoxicity, for which specific quantitative methods are highlighted as a premise. This article presents a targeted metabolomic assay to quantify 33 amino acids and biogenic amines in human urine by high‐performance liquid chromatography coupled with tandem mass spectrometry. Chromatographic separation was carried out on an Agilent Zorbax SB‐C18 column (3.0 × 150 mm, 5 μm) with addition of an ion‐pairing agent in the mobile phase, and MS/MS detection was achieved in both the positive and negative multiple reaction monitoring modes. Good correlation coefficients (r2 > 0.98) were obtained for most analytes. Intra‐ and inter‐day precision, stability, carryover and incurred sample reanalysis met with the acceptance criteria of the guidance of the US Food and Drug Administration. Analysis on urine from healthy volunteers and renal transplantation patients with tacrolimus nephrotoxicity confirmed symmetric dimethylarginine and serine as biomarkers for kidney injury, with AUC values of 0.95 and 0.81 in receiver operating characteristic analysis, respectively. Additionally, symmetric dimethylarginine exhibited a tight correlation with serum creatinine, and was therefore indicative of renal function. The targeted metabolomic assay was time and cost prohibitive for amino acid analysis in human urine, facilitating the biomarker identification of tacrolimus nephrotoxicity.  相似文献   

20.
Tyramine, histamine, putrescine and cadaverine, the most common biogenic amines indicating the food quality, were studied in the transglutaminase-catalyzed reaction. Transglutaminase (protein-glutamine gamma-glutamyltransferase EC 2.3.2.13) catalyzes an acyl transfer reaction between a donor substrate and an acceptor substrate (e.g. biogenic amine) and forms a cross-linkage between substrates with a release of ammonia. The reaction can be monitored by measuring the ammonia produced in the reaction. The concentration of produced ammonia was found to be proportional to the concentration of biogenic amine and could hence be used to determination of biogenic amines in food matrixes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号