首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Super‐atmospheric pressure chemical ionization (APCI) mass spectrometry was performed using a commercial mass spectrometer by pressurizing the ion source with compressed air up to 7 atm. Similar to typical APCI source, reactant ions in the experiment were generated with corona discharge using a needle electrode. Although a higher needle potential was necessary to initiate the corona discharge, discharge current and detected ion signal were stable at all tested pressures. A Roots booster pump with variable pumping speed was installed between the evacuation port of the mass spectrometer and the original rough pumps to maintain a same pressure in the first pumping stage of the mass spectrometer regardless of ion source pressure. Measurement of gaseous methamphetamine and research department explosive showed an increase in ion intensity with the ion source pressure until an optimum pressure at around 4–5 atm. Beyond 5 atm, the ion intensity decreased with further increase of pressure, likely due to greater ion losses inside the ion transport capillary. For benzene, it was found that besides molecular ion and protonated species, ion due to [M + 2H]+ which was not so common in APCI, was also observed with high ion abundance under super‐atmospheric pressure condition. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

2.
3.
4.
5.
6.
Atmospheric pressure chemical ionization (APCI)-mass spectrometry (MS) for fluorinated phenols (C6H5-xFxOH Where x = 0-5) in nitrogen with Cl- as the reagent ion yielded product ions of M Cl- through ion associations or (M-H)- through proton abstractions. Proton abstraction was controllable by potentials on the orifice and first lens, suggesting that some proton abstraction occurs through collision induced dissociation (CID) in the interface region. This was proven using CID of adduct ions (M Cl-) with Q2 studies where adduct ions were dissociated to Cl- or proton abstracted to (M-H)-. The extent of proton abstraction depended upon ion energy and structure in order of calculated acidities: pentafluorophenol > tetrafluorophenol > trifluorophenol > difluorophenol. Little or no proton abstraction occurred for fluorophenol, phenol, or benzyl alcohol analogs. Ion mobility spectrometry was used to determine if proton abstraction reactions passed through an adduct intermediate with thermalized ions and mobility spectra for all chemicals were obtained from 25 to 200 degrees C. Proton abstraction from M Cl- was not observed at any temperature for phenol, monofluorophenol, or difluorophenol. Mobility spectra for trifluorophenol revealed the kinetic transformations to (M-H)- either from M Cl- or from M2 Cl- directly. Proton abstraction was the predominant reaction for tetra- and penta-fluorophenols. Consequently, the evidence suggests that proton abstraction occurs from an adduct ion where the reaction barrier is reduced with increasing acidity of the O-H bond in C6H5-xFxOH.  相似文献   

7.
The use of high-performance liquid chromatography combined with chloride-enhanced atmospheric pressure chemical ionization for the determination of polychlorinated n-alkanes (PCAs, also called chlorinated paraffins or CPs) is described as an alternative to gas chromatographic methods. Atmospheric pressure chemical ionization in the negative ion mode formed exclusively [M+Cl](-) adduct ions and suppressed fragmentation when a chlorinated solvent was added. Limits of detection were 1-2 ng/microL for technical PCA mixtures. Response factors for single short-chain PCA homologues with different degrees of chlorination varied by not more than a factor of 6.5. The developed method was applied for the determination of the composition of technical PCA mixtures as well as for the analysis of PCAs in household commodities. Medium-chain PCAs were found in paint samples at concentrations of 8.2-11.5% (w/w), compared with 7.4-11.5% obtained by gas chromatography combined with electron ionization tandem mass spectrometry.  相似文献   

8.
9.
10.
We have demonstrated that, with simple pH adjustment, volatile drugs such as methamphetamine, amphetamine, 3,4‐methylenedioxymethamphetamine (MDMA), ketamine, and valproic acid could be analyzed rapidly from raw biofluid samples (e.g. urine and serum) without dilution, or extraction, using atmospheric pressure ionization. The ion source was a variant type of atmospheric pressure chemical ionization (APCI) that used a dielectric barrier discharge (DBD) to generate the metastable helium gas and reagent ions. The sample solution was loaded in a disposable glass pipette, and the volatile compounds were purged by nitrogen gas to be reacted with the metastable helium gas. The electrodes of the DBD were arranged in such a way that the generated glow discharge was confined within the discharge tube and was not exposed to the analytes. A needle held at 100–500 V was placed between the ion‐sampling orifice and the discharge tube to guide the analyte ions into the mass spectrometer. After pH adjustment of the biofluid sample, the amphiphilic drugs were in the form of a water‐insoluble oil, which could be concentrated on the liquid surface. By gentle heating of the sample to increase the evaporation rate, rapid and sensitive detection of these drugs in raw urine and serum samples could be achieved in less than 2 min for each sample. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

11.
12.
N‐Oxides are known to undergo three main thermal degradation reactions, namely deoxygenation, Cope elimination (for N‐oxides containing a β‐hydrogen) and Meisenheimer rearrangement, in atmospheric pressure chemical ionization mass spectrometry (APCI‐MS). The ions corresponding to these thermal degradants observed in the ensuing APCI mass spectra have been used to identify N‐oxides as well as to determine the N‐oxidation site when the analyte contains multiple tertiary amine groups. In this paper, we report a thermally induced oxygen migration from one N‐oxide amine to another tert‐amine group present in the same molecule through a six‐membered ring transition state during APCI‐MS analysis. The observed intramolecular oxygen migration resulted in the formation of a new isomeric N‐oxide, rendering the results of the APCI‐MS analysis more difficult to interpret and potentially misleading. In addition, we observed novel degradation behavior that happened after the Meisenheimer rearrangement of the newly formed N‐oxide: a homolytic cleavage of the N? O bond instead of elimination of an aldehyde or a ketone that usually follows the rearrangement. Understanding of these unusual degradation pathways, which have not been reported previously, should facilitate structural elucidation of N‐oxides using APCI‐MS analysis. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

13.
The behavior in atmospheric pressure chemical ionization of selected model polycyclic aromatic compounds, pyrene, dibenzothiophene, carbazole, and fluorenone, was studied in the solvents acetonitrile, methanol, and toluene. Relative ionization efficiency and sensitivity were highest in toluene and lowest in methanol, a mixture of molecular ions and protonated molecules was observed in most instances, and interferences between analytes were detected at higher concentrations. Such interferences were assumed to be caused by a competition among analyte molecules for a limited number of reagent ions in the plasma. The presence of both molecular ions and protonated analyte molecules can be attributed to charge-transfer from solvent radical cations and proton transfer from protonated solvent molecules, respectively. The order of ionization efficiency could be explained by incorporating the effect of solvation in the ionization reactions. Thermodynamic data, both experimental and calculated theoretically, are presented to support the proposed ionization mechanisms. The analytical implications of the results are that using acetonitrile (compared with methanol) as solvent will provide better sensitivity with fewer interferences (at low concentrations), except for analytes having high gas-phase basicities.  相似文献   

14.
Use of optimized instrument parameters that result from statistical experimentation revealed that the sensitivity of atmospheric pressure chemical ionization (APCI) liquid chromatography-mass spectrometry (LC/MS) is greater than the sensitivity of an optimized Thermabeam? LC/MS interface by about 3 orders of magnitude, when tested on aromatic compounds. APCI is one of the few LC/MS techniques in which the chromatogram is directly comparable with liquid chromatographs that use ultraviolet detection. The optimum instrument parameters for a Finnigan SSQ-7000 APCI LC/MS interface were found at low flow rates (e. g., 0. 1 mL/min), relatively low capillary heat (e. g., 225 °C), and high sheath-gas pressure (e. g., 60 lb/in2). The optimization was achieved by monitoring the responses of sensitivity, fragmentation, and cluster ion formation. The fine tuning for high sensitivity calls for a high percentage of water in the mobile phase. In contrast, a high percentage of organic content in the mobile phase is required to obtain abundant protonated molecular ions with respect to fragmentation and clustering. This is an important consideration for analyses of unknowns.  相似文献   

15.
16.
In sesame seeds, high concentrations of lignans are present. When these lignans are fermented in the human colon, a range of structurally different lignans is formed. A good liquid chromatography/mass spectrometry (LC/MS) protocol for the analysis of lignans in complex mixtures is lacking. In order to develop such a protocol, electrospray ionization (ESI)-MS and atmospheric pressure chemical ionization (APCI)-MS, both in the positive and negative ionization mode, were compared. An extract from defatted sesame meal was analyzed by APCI-MS and ESI-MS, before and after deglucosylation. APCI-MS was found to be a more generic method than ESI-MS because lignans, especially sesamolin, sesamin and pinoresinol, were better detected by APCI-MS than by ESI-MS. Positive and negative ionization modes had to be combined in order to detect all lignans in a bacterial culture grown on aglyconic, acid-treated lignans from sesame oil and defatted sesame meal. Lignans with methylenedioxy-bridged furanofuran structures mostly lack phenolic hydroxyl groups and were, therefore, optimally detected in positive ionization mode. Dibenzylbutadiene lignans, which were formed during fermentation, carry hydroxyl groups and were better detected in negative ionization mode.  相似文献   

17.
There is an increasing need to be able to conduct quantitative lipidomics analyses as a complement to proteomics studies. The highest specificity for proteomics analysis can be obtained using methodology based on electrospray ionization (ESI) or atmospheric pressure chemical ionization (APCI) coupled with liquid chromatography/tandem mass spectrometry (LC/MS/MS). For lipidomics analysis it is often necessary to be able to separate enantiomers and regioisomers. This can be very challenging when using methodology based on conventional reversed-phase chromatography. Normal-phase chromatography using chiral columns can provide dramatic improvements in the resolution of enantiomers and regioisomers. However, conventional ESI- and APCI-MS/MS has limited sensitivity, which makes it difficult to conduct studies in cell culture systems where only trace amounts of non-esterified bioactive lipids are present. The use of electron capture APCI-MS/MS overcomes this problem. Enantiomers and regioisomers of diverse bioactive lipids can be quantified using stable isotope dilution methodology coupled with normal-phase chiral chromatography and electron capture APCI-MS/MS. This methodology has allowed a lipidomics profile from rat epithelial cells maintained in culture to be delineated and allowed the effect of a non-selective lipoxygenase inhibitor to be assessed.  相似文献   

18.
A new continuous chromatographic process (VARICOL) has been presented recently. The basic principle of the new VARICOL process consists of an asynchronous shift of the inlet/outlet lines in a multi-column system on a recycle loop. This process has been used to perform the separation of the optical isomers of the SB-553261 racemate. In this paper, we illustrate that for this specific separation, the VARICOL process is more efficient than the well-known SMB process.  相似文献   

19.
A previously uncharacterized source of detection mass bias is shown to be associated with atmospheric pressure ionization mass spectrometry (APIMS), and is attributed to a mass dependence in the sampling of ions from the supersonic free jet expansion of gas emerging from the ion source. The halide ions Cl ?, Br?, and I? are shown to be transported from the ion source aperture to a quadrupole mass filter with efficiencies that increase linearly with increasing mass of the ion. While the polyatomic anions SF 6 - and C7F 14 - are detected with even greater efficiencies than would be expected for monatomic anions of the same mass, this additional sensitivity to the polyatomic anions is thought to be related to ion loss processes occurring within the ion source. The experimental conditions under which these mass bias effects can be minimized or enhanced in APIMS are described.  相似文献   

20.
We present the results of studying the effects of temperature and humidity of the reaction medium and the intensity of ultraviolet radiation on the atmospheric pressure chemical ionization of Penthrite. The peculiarities of the ion mobility spectra of this compound obtained by ion mobility spectrometry-tandem mass spectrometry are analyzed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号