首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
2.
Glycosylation is one of the most common posttranslational modifications (PTMs) of proteins, the characterization of which is commonly achieved through proteomic protocol, involving trypsin digestion followed by liquid chromatography/tandem mass spectrometry (LC/MS/MS). However, it is often not possible to characterize all glycopeptides in a complex sample because of the high complexity of glycoproteomic samples, and the relative lower abundances of glycopeptides in comparison to the unmodified peptides. We present here a targeted MS/MS analysis approach, which utilizes a previously developed computational tool, GlyPID, to guide multiple experiments, thus permitting a complete characterization of all N‐glycosylation sites of glycoproteins present in a complex sample. We have tested our approach using model glycoproteins analyzed by high‐resolution LTQ‐FT MS. The results demonstrate a potential use of our method for a high‐throughput characterization of complex mixtures of glycosylated proteins. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

3.
4.
High-throughput chiral liquid chromatography/tandem mass spectrometry   总被引:3,自引:0,他引:3  
Chiral liquid chromatography is a well-established area of bioanalytical chemistry and is often used during the processes of drug discovery and development. The development and use of a chiral drug require the understanding of the pharmacokinetic characteristics of each of the enantiomers, including potential differences in their absorption, distribution, metabolism, and excretion. Chromatographic techniques coupled to atmospheric pressure ionization-tandem mass spectrometry have shown potential as sensitive and robust tools in the quantitative and qualitative determination of enantiomers in biologic fluids and tissue extracts. However, development of a chiral liquid chromatography method requires time-consuming procedures that are devised empirically. Clearly, there is an incentive to design chromatographic approaches that are easy to use, compatible with mass spectrometry ionization interface conditions, exhibit relatively short run times without compromising sensitivity, and offer a broad analyte specificity. For these reasons, the present paper explores the feasibility of the bonded macrocyclic glycopeptide phases (teicoplanin and vancomycin) for analysis by chiral liquid chromatography/tandem mass spectrometry. Ritalinic acid, pindolol, fluoxetine, oxazepam, propranolol, terbutaline, metoprolol, and nicardipine were tested in this study. Furthermore, an example of a simultaneous chiral LC/MS/MS detection (chromatographic run time approximately 10 min) of four pharmaceutical products resulting in baseline resolutions of all four pairs of enantiomers is presented. Methanol, an MS-compatible mobile phase, was utilized in all the experiments.  相似文献   

5.
The development of LC-MS/MS instruments and related applications improved the large-scale analyses of proteins and peptides in complex biological mixtures. The historical factor limiting these types of studies was the lack of sensitivity and reproducibility. However, the capacity of these analyses to detect proteins and peptides was significantly enhanced to a point where they are routinely performed in specialized laboratories in support to drug development programs as well as prognostic and diagnostic investigations. The analytical strategy used in peptidomic analyses needs to minimize the fluctuation in data measurements that might mask or reduce the precision of the determinations and consequently reduce the sensitivity of the assay. Inherently, it outlines the importance of careful standardization to reduce technical and instrumental variation. Therefore, this review will focus on the strengths and the limitations of the different experimental approaches used for the integration of internal standards in peptidomic studies. This review will examine a wide variety of methods, reagents, instrumentations and data analysis tools available to design peptidomic experiments. Moreover, this review will focus on the importance of precision and accuracy in order to adequately establish analysis threshold to detect peptide expression differences.  相似文献   

6.
Iralukast (CGP 45715A) is a potent peptido-leukotriene antagonist that is active in various in vitro and animal models for the treatment of asthma. An analytical challenge was to develop a sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method with a lower limit of quantitation (LLOQ) of 10 pg/mL for the analysis of iralukast when administered at low doses during clinical trials. Several issues had to be addressed in order to devise a LC/MS/MS assay for the above compound. First, iralukast appeared to be light sensitive and unstable at room temperature under acidic conditions. Second, a LLOQ of 10 pg/mL was needed to support several clinical trials. Third, positive electrospray ionization of iralukast did not yield the necessary sensitivity required for studies in humans. Consequently, LC/MS/MS conditions were optimized for the negative ion mode of detection. Fourth, sample preparation steps proved to be critical to reduce the possibility of microbore HPLC column (50 mm x 1.0 mm i.d.) obstruction, chromatographic deterioration, and matrix-mediated electrospray ion suppression. While our validated method addressed the above challenges, its major drawback was limited sample throughput capability. Nonetheless, plasma concentration-time profiles for patients with moderate asthma after oral administration of 200, 500, 1000, and 5000 microgram/kg/day of iralukast were successfully obtained.  相似文献   

7.
The potential of liquid chromatography combined with tandem mass spectrometry (LC/MS/MS) for the determination of pesticide metabolites in human urine at the sub-ppb level is explored. Metabolites from two organophosphorous pesticides, 4-nitrophenol (from parathion and parathion-methyl) and 3-methyl-4-nitrophenol (from fenitrothion), are taken as model analytes to conduct this study. After direct injection of the urine sample (10 microL), different approaches were evaluated in order to achieve correct quantitation of analytes using an electrospray ionisation (ESI) interface. Thus, the feasibility of using external calibration was checked versus the use of different isotope-labeled internal standards. The advantages of applying coupled-column liquid chromatography (LC/LC) as an efficient clean-up without any type of sample manipulation are also discussed. The combination of LC/LC with ESI-MS/MS allows the direct analysis of free metabolites in urine, as the automated clean-up performed by the coupled-column technique is sufficient for the removal of interferences that suppress the ionisation of analytes in the ESI source. Using this procedure with external calibration, good precision and recoveries, and detection limits below 1 ng/mL are reached with analysis run times of around 8 min. The hyphenated technique LC/LC/ESI-MS/MS is proved to be a powerful analytical tool, allowing the rapid, sensitive and selective determination of 4-nitrophenol and 3-methyl-4-nitrophenol in human urine without any sample treatment.  相似文献   

8.
A high-performance liquid chromatography/electrospray ionization tandem mass spectrometry method was developed and validated for the quantification of pramipexole in human plasma. Following liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a reverse-phase column and analyzed by MS/MS in the multiple reaction monitoring mode using the respective [M + H](+) ions, m/z 212/152 for pramipexole and m/z 409/228 for the IS. The method exhibited a linear dynamic range of 200-8000 pg/mL for pramipexole in human plasma. The lower limit of quantification was 200 pg/mL with a relative standard deviation of less than 8%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. A run time of 3.5 min for each sample made it possible to analyze more than 200 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies.  相似文献   

9.
10.
11.
12.
13.
A multi‐mycotoxin method was developed for the simultaneous determination of trichothecenes (nivalenol, deoxynivalenol, 3‐acetyldeoxynivalenol, 15‐acetyldeoxynivalenol, neosolaniol, fusarenon‐X, diacetoxyscirpenol, HT‐2 toxin, T‐2 toxin), aflatoxins (aflatoxin‐B1, aflatoxin‐B2, aflatoxin‐G1 and aflatoxin‐G2), Alternaria toxins (alternariol, alternariol methyl ether and altenuene), fumonisins (fumonisin‐B1, fumonisin‐B2 and fumonisin‐B3), ochratoxin A, zearalenone, beauvericin and sterigmatocystin in sweet pepper. Sweet pepper was extracted with ethyl acetate/formic acid (99:1, v/v). After splitting up the extract, two‐thirds of the extract was cleaned up using an aminopropyl column followed by an octadecyl column. The remaining part was cleaned up using a strong anion‐exchange column. After recombination of both cleaned parts of the sample extract, the combined solvents were evaporated and the residue was dissolved in mobile phase; 20 µL was injected into the chromatographic system, so only one run was used to separate and detect the mycotoxins in positive electrospray ionization using selected reaction monitoring. The samples were analyzed with a Micromass Quattro Micro triple quadrupole mass spectrometer (Waters, Milford, MA, USA). The mobile phase consisted of variable mixtures of water and methanol, 1% acetic acid and 5 mM ammonium acetate. The limits of detection of the multi‐mycotoxin method varied from 0.32 µg.kg?1 to 42.48 µg.kg?1. The multi‐mycotoxin liquid chromatography/tandem mass spectrometry (LC/MS/MS) method fulfilled the method performance criteria required by the Commission Regulation (EC) No 401/2006. Sweet peppers inoculated by Fusarium species were analyzed using the developed method. Beauvericin (9–484 µg.kg?1) and fumonisins (fumonisin‐B1 up to 4330 µg.kg?1, fumonisin‐B2 up to 4900 µg.kg?1, and fumonisin‐B3 up to 299 µg.kg?1) were detected. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

14.
15.
An ultra‐high‐performance liquid chromatography/electrospray ionisation tandem mass spectrometry system is described for the separation and characterisation of uroporphyrinogen, heptacarboxylic acid porphyrinogen, hexacarboxylic acid porphyrinogen, pentacarboxylic acid porphyrinogen and coproporphyrinogen. The separation was carried out on a 100 mm × 2.1 mm Thermo‐Hypersil BDS column (2.4 µm average particle size) by gradient elution with a mixture of acetonitrile, methanol and 1 mol/L aqueous ammonium acetate buffer, pH 5.16, as eluent. The fragmentation pattern of each compound was established by collision‐induced dissociation tandem mass spectrometry. The most characteristic fragmentation was ring opening at one of the four methylene bridges of the protonated porphyrinogen molecule followed by further cleavages of methylene bridges linking the four pyrrole rings at various points to give product ions with methylenepyrrolenine, methylene‐dipyrrolenine and methylene‐tripyrrolenine structures. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

16.
A quantitative Ultra Performance liquid chromatography/tandem mass spectrometry (UPL/MS/MS) protocol was developed for a five-compound mixture in rat plasma. A similar high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) quantification protocol was developed for comparison purposes. Among the five test compounds, three preferred positive electrospray ionization (ESI) and two preferred negative ESI. As a result, both UPLC/MS/MS and HPLC/MS/MS analyses were performed by having the mass spectrometer collecting ESI multiple reaction monitoring (MRM) data in both positive and negative ion modes during a single injection. Peak widths for most standards were 4.8 s for the HPLC analysis and 2.4 s for the UPLC analysis. There were 17 to 20 data points obtained for each of the LC peaks. Compared with the HPLC/MS/MS method, the UPLC/MS/MS method offered 3-fold decrease in retention time, up to 10-fold increase in detected peak height, with 2-fold decrease in peak width. Limits of quantification (LOQs) for both HPLC and UPLC methods were evaluated. For UPLC/MS/MS analysis, a linear range up to four orders of magnitude was obtained with r2 values ranging from 0.991 to 0.998. The LOQs for the five analytes ranged from 0.08 to 9.85 ng/mL. Three levels of quality control (QC) samples were analyzed. For the UPLC/MS/MS protocol, the percent relative standard deviation (RSD%) for low QC (2 ng/mL) ranged from 3.42 to 8.67% (N = 18). The carryover of the UPLC/MS/MS protocol was negligible and the robustness of the UPLC/MS/MS system was evaluated with up to 963 QC injections.  相似文献   

17.
Tanreqing capsule (TRQC) is a formulation frequently used in traditional Chinese medicine to treat pyrexia, cough, expectoration and pharyngalgia. Since the pharmacological action of traditional Chinese medicines is closely related to their complex and diverse constituents, understanding the exact composition of TRQC is important to elucidate its clinical effectiveness and mechanism of action as well as to establish quality control methods and resolve safety issues. Herein, we employed high‐performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry for the simultaneous quantitation of 23 bioactive compounds in five batches of TRQC; the analytes could be categorized into five types: organic acids (seven compounds), flavonoids (10 compounds), iridoids (two compounds), phenylethanoid glycosides (two compounds) and bile acids (two compounds). The calibration curves for all analytes showed good linearity (r > 0.9953), and the inter‐ and intra‐day precisions did not exceed 4.94 and 4.97%, respectively. The recoveries varied from 90.47% to 109.80%; the corresponding relative standard deviations (RSDs) did not exceed 4.94%; and the repeatability (RSD < 4.72%) and stability (RSD < 4.88%) were also within acceptable limits. Thus, this study can be viewed as a fundamental reference for setting comprehensive TRQC quality standards.  相似文献   

18.
19.
Little is known about melamine (MEL) analysis in children's urine. In this study, an isotopic ultra‐performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS) method was developed and systematically validated for the analysis of MEL in urine. The method is easily performed and comprises acidification, solid‐phase extraction (SPE) and UPLC/MS/MS analysis. 13C3N3(15NH2)3 was used as the internal standard (IS) for calibration. Transition ions m/z 127 > 85 of MEL and m/z 133 > 89 of the IS were used for quantification and m/z 127 > 68 of MEL was used for quantitative confirmation. Recovery and precision were assessed to guarantee the applicability of the method. The limit of quantification (LOQ) was 0.01 µg/mL while the calculated method detection limit was 0.006 µg/mL. The mean recoveries ranged from 96–99%. The method was then applied to analyze urine samples from children who had potentially consumed MEL‐tainted dairy products during screening in Taiwan. Ten nephrolithiasis cases and 20 age‐ and gender‐matched controls were selected for this study. Three out of the 10 nephrolithiasis cases had elevated levels of MEL. Comparatively, twenty age‐ and gender‐matched non‐nephrolithiasis controls consuming Taiwan brand milk powder all showed MEL levels lower than the detection limit except for two children with background levels of 0.02 µg/mL. The background level in these children urine samples was established by UPLC/MS/MS analysis. Positive results of urine MEL tests might be associated with nephrolithiasis in these candidates. Measurement of urine MEL concentration can be helpful in confirming MEL‐related nephrolithiasis, but its clinical application needs further clarification. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

20.
In conjunction with an AOAC Task Group on dietary supplements, a liquid chromatography/tandem mass spectrometry (LC-MS/MS) method was validated for measurement of 6 major alkaloids in raw ephedra sinica herb, ephedra extracts, ephedra tablets, complex dietary supplements containing ephedra, and a high-protein drink mix containing ephedra. The amount of ephedrine-type alkaloids present was determined by LC with mass selective detection. Six replicates of each matrix were analyzed on 3 separate occasions. The presence of 6 ephedrine-type alkaloids was detected at a level > 0.5 microg/g based on a 0.5 g sample. The standard curve range for this assay is from 0.02 to 1.0 microg/mL. Appropriate dilutions covered a wide range of specific alkaloid concentrations. The calibration curves for all 6 analytes had correlation coefficients > 0.995.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号