首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
C Fanali  G D'Orazio  S Fanali 《Electrophoresis》2012,33(16):2553-2560
Nano-LC and CEC were studied for the separation of cytochrome c tryptic digest. The peptides mixture was analyzed using either a nano-LC commercial or a laboratory assembled instrumentation coupled with an IT-ESI-MS by using a nanospray interface. CEC experiments were carried out with a CE apparatus coupled with the IT-ESI-MS through a liquid junction interface. Analytes were separated utilizing C18 silica based stationary phases, of different properties and origin, silica derivatized with cyano groups and C18 monolithic material. The last column, just because the chemical composition (absence of charged/chargeable groups) was tested only using nano-LC. Best results mainly related to the highest number of peptides separated and column equilibration time were obtained by nano-LC employing the C18 stationary phase (detection of 20 peptides, coverage of 88%). Similar results were achieved using both commercial and laboratory assembled instrumentation. The use of CEC revealed a higher separation efficiency and shorter analysis time. However, the number of separated peptides were lower than those observed in nano-LC. In CEC the use of capillaries packed with cyanosilica particles offered better results; however, less satisfactory than those observed in the miniaturized LC technique. Provided the use of the same stationary phase and taking into account the driving forces, the two techniques can be considered complementary, offering different information related to the retention times of the studied peptides.  相似文献   

3.
Capillary separations interfaced to tandem mass spectrometry provide a very powerful tool for the characterization of biological macromolecules such as proteins and peptides. The development of real time data-dependent data acquisition has further enhanced the capability of this method. However, the application of this technique to fast capillary separations has been limited by the relatively slow spectral acquisition speed available on scanning mass spectrometers. In this work, an ion trap storage/reflectron time-of-flight mass spectrometer (IT/reTOF-MS) has been used as an on-line tandem mass detector for capillary high-performance liquid chromatography (HPLC) and capillary electrophoresis (CE) separations of peptide mixtures including a protein digest. By taking advantage of the nonscanning property of the time-of-flight mass spectrometer, a fast spectral acquisition rate has been achieved. This fast spectral acquisition rate, combined with a new protocol that speeds up tickle voltage optimization, has provided MS/MS spectra for multiple components in a hemoglobin digest during one liquid chromatography/mass spectrometry/mass spectrometry (LC/MS/MS) run. Further, the IT/reTOF-MS has the speed to provide MS/MS spectra for multiple components in a CE separation of a synthetic peptide mixture within one CE/MS/MS run.  相似文献   

4.
A new type of hydrophilic derivatized capillary has been used to enable the on-line capillary electrophoresis separation and electrospray mass spectrometric detection of a mixture of proteins containing bovine cytochrome c, tuna cytochrome c and horse heart myoglobin. Less than 40 fmol of each compound were loaded into the capillary. Baseline resolution of components was achieved, as were accurate assignments of molecular masses. The hydrophilic derivatized capillaries were taken through extensive testing procedures to characterize their performance and capabilities for protein analysis. A mixture of six proteins (cytochrome c, ribonuclease A, -chymotrypsinogen, myoglobin, carbonic anhydrase II and -lactalbumin) in acetic acid—sodium acetate buffer was used to delineate the relationships between migration time and pH, along with migration time and buffer concentration for each protein. The variations in capillary efficiency as a function of pH and as a function of buffer concentration were also characterized for the same six proteins in the acetic acid–sodium acetate system. A pH of 4.8 was found to offer an excellent compromise between separation efficiency (up to 500 000 theoretical plates) and analysis time. Capillary efficiencies were also found to be very good when employing a Tris · HCl electrolyte adjusted to pH 4.8. Lastly, electropherogram reproducibility and capillary durability were examined with the finding that little deterioration of the capillary occurred over the course of 400 injections (200 h run time). This represents a notable improvement over previously documented derivatization procedures designed to reduce protein adsorption to fused-silica capillary walls  相似文献   

5.
An approach based on staggered multistep elution solid-phase extraction (SPE) capillary electrophoresis/tandem mass spectrometry (CE/MS/MS) was developed in the analysis of digested protein mixtures. On-line coupling of SPE with CE/MS was achieved using a two-leveled two-cross polydimethylsiloxane (PDMS)-based interface. Multistep elution SPE was used prior to CE to provide an additional dimension of separation, thus extending the separation capacity for the peptide mixture analysis. By decreasing in the number of co-eluting peptides, problems stemming from ionization suppression and finite MS/MS duty cycle were reduced. As a result, sequence coverage increased significantly using multistep elution SPE-CE/MS/MS compared to one-step elution SPE-CE/MS/MS in the analysis of a single protein tryptic digest (49% vs. 18%) and a six protein tryptic digest (22-71% vs. 10-44%). A staggered CE method was incorporated to increase the throughput. The electropherograms of consecutive CE runs were partially overlapped by injecting the sample plug at a fixed time interval. With the use of a 5 min injection interval, slightly poor results were obtained in comparison with the sequential CE method while the total analysis time was reduced to 28%.  相似文献   

6.
A systematic study for the optimization and implementation of high-performance capillary electrophoresis (HPCE) in conjunction with negative ion electrospray ionization-quadrupole time of flight-tandem mass spectrometry (ESI-QTOF-MS/MS) for the analysis of complex glycolipids is described. The performance of the capillary electrophoresis (CE) and off-line CE/ESI-QTOF-MS approach has been explored for screening a complex ganglioside mixture from bovine brain. All instrumental and solution parameters demonstrated to require special adjustment and to have the most substantial effect on the CE separation, abundance of product ions produced in a low-energy collision-induced dissociation (CID) process and their detection by MS/MS, when attempting to identify and sequence single ganglioside molecular species from CE eluted fractions. Upon optimization of the experimental parameters, an efficient methodology emerged providing the general basic requirements for combined CE/ESI-MS analysis of this type of complex glycoconjugate.  相似文献   

7.
We have developed a novel sheath-flow interface for low-flow electrospray ionization mass spectrometry (ESI-MS) and capillary electrophoresis/electrospray mass spectrometry (CE/ESI-MS). The interface is composed of two capillaries. One is a tapered fused-silica ESI emitter suitable for microliter and nanoliter flow rate electrospray and the other is a tail-end gold-coated CE separation column that is inserted into the emitter. A sheath liquid is supplied between the column and the emitter capillaries. The gold coating and the sheath liquid are used as the conducting media for ESI and the CE circuit. This novel design was initially evaluated by an infusion ESI-MS analysis of the most common antiretroviral dideoxynucleosides, followed by CE/MS coupling analysis of several antidepressant drugs. With infusion studies, the effects of the sheath liquid and the sample flow rates on detection sensitivity and signal stability were investigated. For an emitter with an internal diameter of 30 microm, the optimum flow rates for the sheath and the sample were 200 and 300 nL/min, respectively. The main improvement of this approach in comparison with conventional sheath liquid approaches using an ionspray interface is the gain in sensitivity. Sensitivities were three times better for dideoxynucleosides analyzed by infusion and 12 times higher for antidepressant drugs analyzed by CE/MS with this interface compared with ionspray. The emitter is durable, disposable, and simple to fabricate.  相似文献   

8.
Simpson DC  Smith RD 《Electrophoresis》2005,26(7-8):1291-1305
Mass spectrometry (MS)-based proteomics is currently dominated by the analysis of peptides originating either from digestion of proteins separated by two-dimensional gel electrophoresis (2-DE) or from global digestion; the simple peptide mixtures obtained from digestion of gel-separated proteins do not usually require further separation, while the complex peptide mixtures obtained by global digestion are most frequently separated by chromatographic techniques. Capillary electrophoresis (CE) provides alternatives to 2-DE for protein separation and alternatives to chromatography for peptide separation. This review attempts to elucidate how the most promising CE modes, capillary zone electrophoresis (CZE) and capillary isoelectric focusing (CIEF), might best be applied to MS-based proteomics. CE-MS interfacing, mass analyzer performance, column coating to minimize analyte adsorption, and sample stacking for CZE are considered prior to examining numerous applications. Finally, multidimensional systems that incorporate CE techniques are examined; CZE often finds use as a fast, final dimension before ionization for MS, while CIEF, being an equilibrium technique, is well-suited to being the first dimension in automated fractionation systems.  相似文献   

9.
In order to develop a robust and easy-to-use technique for characterization of bacterial polysaccharides, a pseudo-hydrolysis strategy was investigated. Based on in-source collision-induced dissociation, polysaccharide molecular ions were fragmented within the orifice-skimmer region of an electrospray ionization (ESI) mass spectrometer. The fragment ions thus generated were then analyzed similarly to the conventional ESI mass spectrometry approach. MS/MS scanning was applied to obtain product-ion spectra of the primary fragments for sequencing. To further improve the sensitivity and separation of polysaccharides from other components in the samples, a pressure-assisted capillary electrophoresis/mass spectrometry (CE/MS) system was employed. Using bacterial polysaccharides as model compounds, the mass spectra obtained for polysaccharide repeating units generated through chemical hydrolysis and in-source fragmentation were directly compared, both in positive and negative ion modes. With the additional separation of impurities provided by CE, the success of this technique has been demonstrated for structural analysis of O-chain polysaccharides (O-PS) and capsular polysaccharides (CPS). In-source fragmentation was applied to promote the formation of structurally relevant repeating units of heterogeneous CPS that would remain undetected using conventional ESI conditions. This approach was proven to be particularly useful for probing the subtle structural differences in monosaccharide composition and functionalities arising across bacterial serotypes.  相似文献   

10.
A capillary electrophoresis (CE) method coupled to electrospray ionization ion trap tandem mass spectrometry (ESI-IT-MS/MS) is described for the rapid analysis of carnitine, acetylcarnitine, and propionylcarnitine in human plasma. Optimization of the procedure was achieved by a reduced sample pretreatment and after examining several physicochemical parameters that influence both the CE separation and the MS analytes detection. The analysis of total carnitine in human plasma after hydrolysis of short-chain metabolites is also shown. The analysis of carnitine and metabolites was obtained in less than 10 min using a 200 mM ammonium formate buffer, pH 2.5, with high sensitivity and specificity using the MS detection in product ion scan mode. The method was tested for quantitative recovery using dialyzed human plasma as matrix and showed linearity in the concentrations ranges 20–160, 1–32, and 0.25–8 μM for carnitine, acetylcarnitine, and propionylcarnitine with (squared) correlation coefficients of 0.9984, 0.9995, and 0.9991, respectively. The intraday and intermediate analysis repeatability and accuracy are within 15% of relative standard deviation (RSD) at low, medium, and high concentration and within/or slight exceeding 20% at the lower limit of quantitation (LLOQ). The method is sensitive for determining carnitine and its metabolites in human plasma with high specificity.  相似文献   

11.
Implementation and optimization of an off-line capillary electrophoresis (CE)/(−)nanoESIchip-quadrupole time-of-flight (QTOF) mass spectrometric (MS) and tandem MS system for compositional mapping and structural investigation of components in complex carbohydrate mixtures is described. The approach was developed for glycoscreening and applied to O-glycosylated peptides from urine of a patient suffering from α-N-acetylhexosaminidase deficiency, known as Schindler's disease. The fundamental issue of sensitivity, previously representing a serious drawback of the off-line CE/MS analysis, could be positively addressed by the off-line conjunction of CE with automated chip-based ESI-QTOF-MS to provide flexibility for CE/chip MS coupling and enhance structural elucidation of single components in heterogeneous mixtures. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

12.
The solution chemistry conditions necessary for optimum analysis of peptides by capillary zone electrophoresis (CZE)/electrospray ionization mass spectrometry and CZE electrospray ionization tandem mass spectrometry have been studied. To maximize the signal-to-noise ratio of the spectra it was found necessary to use acidic CZE buffers of low ionic strength. This not only increases the total ion current, but it also serves to fully protonate the peptides, minimizing the distribution of ion current across the ensemble of possible charge states. The use of acidic buffers protonates the peptides, which is advantageous for mass spectrometry and tandem mass spectrometry analysis, but is problematic with CZE when bare fused silica CZE columns are used. These conditions produce positively charged peptides, and negatively charged silanol moieties on the column wall, inducing adsorption of the positively charged peptides, thus causing zone broadening and a loss in separation efficiency. This problem was circumvented by the preparation of chemically modified CZE columns, which, when used with acidic CZE buffers, will have a positively charged inner column wall. The electrostatic repulsion between the positively charged peptides and the positively charged CZE column wall minimizes adsorption problems and facilitates high efficiency separations. Full-scan mass spectra were acquired from injections of as little as 160 fmols of test peptides, with CZE separation efficiencies of up to 250,000 theoretical plates.  相似文献   

13.
A liquid-junction-type interface where a thin spraying capillary is inserted inside the separation capillary was constructed for coupling nonaqueous wide-bore capillary electrophoresis (CE) to mass spectrometry (MS). The robust structure of the interface provided fairly easy capillary handling. The study was carried out with uncoated CE capillaries of 200 and 320 microm inner diameter (ID). 1-Propanol-acetonitrile (80:20 v/v) with acetate electrolyte provided a low conducting medium for CE and good spraying conditions for electrospray ionization (ESI) without sheath-flow and drying gas. Methamphetamine, alprenolol, and levorphanol served as model compounds. Approximate detection limits with the 200 microm ID capillary were 35-265 ng/mL.  相似文献   

14.
The use of capillary zone electrophoresis (CZE) and capillary zone electrophoresis/mass spectrometry (CZE/MS) has been demonstrated, in principle, for the separation of nicotine and nicotine metabolites. The buffer system developed for separation and detection by CZE/UV was modified for use in CZE/MS analysis. Several of the metabolites are isobaric and tandem mass spectrometric (MS/MS) techniques have been used to differentiate such analytes.  相似文献   

15.
CE/frontal analysis (CE/FA) is probably one of the most frequently used modes of CE for studying affinity interactions. It is typically performed with classic UV-Vis detection that suffers from low concentration sensitivity. To overcome this limitation, the applicability of CE/FA in combination with ESI-MS detection for the investigation of drug–HSA interactions was demonstrated. The developed new method combines the advantages of CE/FA, such as low sample consumption and no labeling or immobilization of interacting partners, with the benefits of MS detection, such as higher selectivity and sensitivity; moreover, it can be used for molecules lacking a fluorophore or chromophore. The binding parameters of tolbutamide (TL) and glimepiride (GLP), first- and second-generation antidiabetics that differ strongly in their solubility in aqueous solutions, were investigated by this CE/FA-MS method. This method, in contrast to the CE/FA method with the most commonly used UV-Vis detection, is more sensitive; an almost three times lower LOD was reached. The binding parameters of TL and GLP were investigated by this CE/FA-MS method and compared with the literature data. The binding constant value of TL obtained by UV-Vis detection was lower than the value obtained by the method hyphenated with MS detection, which is probably given by the influence of the ESI parameters on the stability of drug–HSA complex. In addition, the ratio of TL and HSA concentrations was divergent in both of the experimental approaches. Finally, it can be concluded that both detection methods have their strengths and weaknesses.  相似文献   

16.
A novel approach in glycosaminoglycomics, based on sheathless on-line capillary electrophoresis/nanoelectrospray ionization-quadrupole time of flight-mass spectrometry (CE/nanoESI-QTOF-MS) and tandem MS of extended chondroitin sulfate/dermatan (CS/DS) oligosaccharide chains is described. The methodology required the construction of a new sheathless CE/nanoESI-QTOF-MS configuration, its implementation and optimization for the high sensitivity analysis of CS/DS oligosaccharide mixtures from conditioned culture medium of decorin transfected human embryonic kidney (HEK) 293 cells. Under newly established sheathless on-line CE/(-)nanoESI conditions for glycosaminoglycan (GAG) ionization and MS detection, single CS/DS oligosaccharide components of extended chain length and increased sulfation degree were identified. Molecular ions corresponding to species carrying 5 and 6 negative charges could be generated for large GAG oligosaccharide species in the negative ion nanoESI-MS. The optimized on-line conditions enabled the detection of molecular ions assigned to oversulfated tetradeca-, octadeca-, and eicosasaccharide CS/DS molecules, which represent the category of largest sulfated GAG-derived oligosaccharides evidenced by CE/ESI-MS. By on-line CE/ESI tandem MS in data-dependent acquisition mode the oversulfated eicosasaccharide species could be sequenced and the localization of the additional sulfate group along the chain could be determined.  相似文献   

17.
The interfacing of capillary electrophoresis (CE) with mass spectrometry (MS) is well established and may be accomplished by use of either a coaxial arrangement or by employing a liquid T-junction. In both these interfaces a make-up flow is introduced. This is required because of the mismatch in flow rates for capillary electrophoresis approximately nL/min and 'true' electrospray approximately 2-10 microL/min. Electrical connectivity may also be established where the liquid flows meet (the introduction of nanospray renders the use of make-up flow unnecessary). Hydrogen/deuterium (H/D) exchange occurs in solution when there are labile hydrogen atoms present in a molecule. The establishment of the presence and the number of such exchangeable hydrogen atoms may be of importance in the identification and differentiation of compounds. It may also be an aid in the structural elucidation of unknown materials. We have investigated the feasibility of carrying out H/D exchange via a CE/MS interface. This involved the addition of D2O to the sheath flow and our preliminary results showing the separations of drug substances, subsequently undergoing exchange, are presented.  相似文献   

18.
We describe a two-dimensional capillary electrophoresis system that incorporates a replaceable enzymatic microreactor for on-line protein digestion. In this system, trypsin is immobilized on magnetic beads. At the start of each experiment, old beads are flushed to waste and replaced with a fresh plug of beads, which is captured by a pair of magnets at the distal tip of the first capillary. For analysis, proteins are separated in the first capillary. A fraction is then parked in the reactor to create peptides. Digested peptides are periodically transferred to the second capillary for separation; a fresh protein fraction is simultaneously moved to the reactor for digestion. An electrospray interface is used to introduce peptides into a mass spectrometer for analysis. This procedure is repeated for several dozen fractions under computer control. The system was demonstrated by the separation and digestion of insulin chain b oxidized and β-casein as model proteins.  相似文献   

19.
We have fabricated a coaxial sheath liquid flow microelectrospray ionization (microESI) interface for capillary electrophoresis coupled with mass spectrometry (CE/MS). The ESI interface, which features a reduced probe diameter (130 microm i.d. x 174 microm o.d.) with a nebulizer-free format, can relatively easily electrospray a large amount of make-up sheath liquid (5-10 microL/min) over the long term (more than 80 runs) with a high degree of stability. The interface also provides higher separation qualities and improved detection sensitivities compared with a conventional ion spray (IS) interface.  相似文献   

20.
A system of microchip capillary electrophoresis/electrospray ionization mass spectrometry (microchip-CE/ESI-MS) for rapid characterization of proteins has been developed. Capillary electrophoresis (CE) enables rapid analysis of a sample present in very small quantity, such as at femtomole levels, at high resolution. Faster CE/MS analysis is expected by downsizing the normal capillary to the microchip (microchip) capillary. Although rapidity and high resolution are advantages of CE separation, electroosmotic flow (EOF) instability caused by the interaction between proteins and the microchannel surface results in low reproducibility in the analysis of basic proteins under neutral pH conditions. By coating the microchannel surface with a basic polymer, polyE-323, basic proteins, which have pI values of over 7.5, could be separated and detected by microchip-CE/MS on quadrupole (Q) and time-of-flight (TOF) hybrid instruments. By increasing the cone and collision voltages during the analysis by microchip-CE/ESI-MS of a small protein, some product ions, which contain the sequence information, could also be obtained, i.e., 'top-down' analysis of the protein could be accomplished with this microchip-CE/MS system. To our knowledge, this is the first report of 'top-down' analysis of a protein by microchip-CE/MS. Since it requires a much shorter time and a smaller sample amount for analysis than the conventional liquid chromatography (LC)/ESI-MS method, microchip-CE/MS promises to be suitable for the high-throughput characterization of proteins.  相似文献   