首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
Solid phase micro-extraction in a miniature ion trap mass spectrometer   总被引:1,自引:0,他引:1  
Fiber introduction mass spectrometry (FIMS), a variation of solid-phase microextraction (SPME) and membrane introduction mass spectrometry (MIMS), is employed with a miniature mass spectrometer. The inlet system, constructed of commercially available vacuum parts, allows the direct introduction of the SPME needle vacuum chamber into the mass spectrometer. Thermal desorption of the analyte from the poly(dimethylsiloxane) (PDMS) coated fiber was achieved with a built in nichrome heater, followed by electron ionization of the analytes internal to the cylindrical ion trap (CIT). The system has been tested with several volatile organic compounds (VOC) in air and to analyze the headspace over aqueous solutions, with limits of detection in the low ppb range. The signal rise (10-90%) and fall (90-10%) times for the system ranged from 0.1 to 1 s (rise) and 1.2 to 6 s (fall) using heated desorption. In addition, this method has been applied to quantitation of toluene in benzene, toluene, xylene (BTX) mixtures in water and gasoline. This simple and rapid analysis method, coupled to a portable mass spectrometer, has been shown to provide a robust, simple, rapid, reproducible, accurate and sensitive (low ppb range) fieldable approach to the effective in situ analysis of VOC in various matrices.  相似文献   

3.
Sokol E  Edwards KE  Qian K  Cooks RG 《The Analyst》2008,133(8):1064-1071
A miniature ion trap mass analyzer was applied to the analysis of traces of hydrocarbons and simple heteroatomics in the vapor phase and in aqueous solution. Vapors of acetone, acetic acid, acetonitrile, benzene, butanethiol, carbon disulfide, hexane, dichloromethane, naphthalene, toluene and xylenes were detected and quantified using solid sorbent trapping and, in some cases, by passage through a membrane interface. Aqueous solutions of benzene, toluene, xylenes, hexane and a petroleum naphtha distillate were examined using the membrane interface. Sampling, detection and identification of all compounds was completed in times of less than one minute. The gas-phase samples of toluene and benzene were detected at 200 ppt (limit of detection, LOD) for toluene and 600 ppt for benzene. Identification of benzene and xylene in aqueous solutions was readily achieved with LODs of 200 and 400 ppb, respectively. Quantification over a linear dynamic range of two orders of magnitude for the aqueous samples and three orders of magnitude for the vapor-phase samples was demonstrated.  相似文献   

4.
5.
A recently constructed miniature mass spectrometer, based on a cylindrical ion trap (CIT) mass analyzer, is used to perform ion/molecule reactions in order to improve selectivity for in situ analysis of explosives and chemical warfare agent simulants. Six different reactions are explored, including several of the Eberlin reaction type (M. N. Eberlin and R. G. Cooks, Org. Mass Spectrom., 1993, 28, 679-687) as well as novel gas-phase Meerwein reactions. The reactions include (1) Eberlin transacetalization of the benzoyl, 2,2-dimethyloximinium, and 2,2-dimethylthiooximinium cations with 2,2-dimethyl-1,3-dioxolane to form 2-phenyl-1,3-dioxolanylium cations, 2,2-dimethylamine-1,3-dioxolanylium cations and the 2,2-dimethylamin-1,3-oxathiolanylium cations, respectively; (2) Eberlin reaction of the phosphonium ion CH3P(O)OCH3+, formed from the chemical warfare agent simulant dimethyl methylphosphonate (DMMP), with 1,4-dioxane to yield the 1,3,2-dioxaphospholanium ion, a new characteristic reaction for phosphate ester detection; (3) the novel Meerwein reaction of the ion CH3P(O)OCH3+ with propylene sulfide forming 1,3,2-oxathionylphospholanium ion; (4) the Meerwein reaction of the benzoyl cation with propylene oxide and propylene sulfide to form 4-methyl-2-phenyl-1,3-dioxolane and its thio analog, respectively; (5) ketalization of the benzoyl cation with ethylene glycol to form the 2-phenyl-1,3-dioxolanylium cation; (6) addition/NO2 elimination involving benzonitrile radical cation in reaction with nitrobenzene to form an arylated nitrile, a diagnostic reaction for explosives detection and (7) simple methanol addition to the C7H7+ ion, formed by NO2 loss from the molecular ion of p-nitrotoluene to form an intact adduct. Evidence is provided that these reactions occur to give the products described and their potential analytical utility is discussed.  相似文献   

6.
An ion trap mass analyzer has been attached to an organic secondary ion microprobe. A pressure differential >100 can be maintained between the ion trap and microprobe. The well-focused secondary ion beam can transit a small (2 mm) diameter tube, but gas flow from ion trap to microprobe is impeded. This pressure differential allows the microprobe to retain imaging capability. Ion trap and microprobe data systems are integrated by taking advantage of the highly reproducible periodicity of the ion trap operating in resonant ejection mode and asynchronous signal and data acquisition afforded by commercially available interface cards. Secondary ion mass spectra and images obtained indicate an approximately 10-fold improvement in sensitivity, although preliminary evidence indicates low (<1%) trapping efficiency. Image data acquisition using the ion trap for mass analysis requires at least 10 times as much time compared to using a quadrupole mass filter because the mass-selected instability mode is used for mass analysis, i.e., mass resolution in the ion trap is not continuous as it is in the quadrupole.  相似文献   

7.
A better understanding of nanoelectrospray ionization (nano‐ESI) would be beneficial in further improving the performances of nano‐ESI. In this work, the pulsed high‐voltage (HV) nano‐ESI has been electrically modeled and then systematically characterized by both voltage‐current and mass spectrometry measurements. First, the equivalent resistance of a nano‐ESI source changes with respect to both emitter tip diameter and the HV applied. Increased voltage could improve both spray current and ionization efficiency of the pulsed HV nano‐ESI. Compared with conventional DC HV method, a pulsed HV has less heating effect on the capillary tip and thus allowing the application of a much higher voltage onto a nano‐ESI source. As a result, a pulsed HV nano‐ESI could further boost the ionization efficiency of nano‐ESI by employing even higher voltages than conventional DC nano‐ESI sources.  相似文献   

8.
A two-dimensional quadrupole ion trap mass spectrometer   总被引:8,自引:0,他引:8  
The use of a linear or two-dimensional (2-D) quadrupole ion trap as a high performance mass spectrometer is demonstrated. Mass analysis is performed by ejecting ions out a slot in one of the rods using the mass selective instability mode of operation. Resonance ejection and excitation are utilized to enhance mass analysis and to allow isolation and activation of ions for MS(n) capability. Improved trapping efficiency and increased ion capacity are observed relative to a three-dimensional (3-D) ion trap with similar mass range. Mass resolution comparable to 3-D traps is readily achieved, including high resolution at slower scan rates, although adequate mechanical tolerance of the trap structure is a requirement. Additional advantages of 2-D over 3-D ion traps are also discussed and demonstrated.  相似文献   

9.
The discontinuous atmospheric pressure interface (DAPI) has been developed to allow a direct transfer of ions from atmosphere into an ion trap mass spectrometer with minimum pumping capability. Air is introduced into the trap with ions and used as a buffer gas for the ion trap operation. In this study, a method of introducing helium as a second buffer gas was developed for a miniature mass spectrometer using a dual DAPI configuration. The buffer gas effects on the performance of a linear ion trap (LIT) with hyperbolic electrodes were characterized for ion isolation, fragmentation and a mass-selective instability scan. Significant improvement was obtained with helium for resolutions of mass analysis and ion isolation, while moderate advantage was gained with air for collision-induced dissociation. The buffer gas can be switched between air and helium for different steps within a single scan, which allows further optimization of the instrument performance for tandem mass spectrometry.  相似文献   

10.
11.
Zhu Z  Xiong C  Xu G  Liu H  Zhou X  Chen R  Peng WP  Nie Z 《The Analyst》2011,136(7):1305-1309
A miniature cylindrical ion trap mass spectrometer (CIT-MS) equipped with an inexpensive mechanical pump was constructed, and used to measure the masses of cells and microparticles generated by laser induced acoustic desorption ionization. Compared with a previous lab scale quadrupole ion trap mass spectrometer (QIT-MS), the novel miniature CIT-MS had smaller volume (the radius r(0)=5 mm), simpler ion trap fabrication and overall instrument construction, required a lower trapping voltage, and reduced the weight, power and cost of the instrument. The CIT-MS was calibrated using standard polystyrene beads of 2.982 μm diameter. The CIT-MS was used to measure the total dry weight of human red blood cells (RBCs) from a healthy female adult (2.12×10(13) Da) and a patient with anemia (1.35×10(13) Da). The coefficient of variance (CV) for the healthy individual was 21% and that for the patient was 30.4%. The CIT-MS was also applied to guinea pig RBCs and the total dry weight was determined as 1.34×10(13) Da with a CV of 37.9%. These measurements are consistent with previous QIT-MS measurements. The new miniaturized instrument has potential for applications in field-portable, biological and aerosol analysis.  相似文献   

12.
By using a modified ion trap mass spectrometer, resolution in excess of 30,000 (FWHM) at m I z 502 is demonstrated. The method of increasing resolution in the ion trap mass spectrometer operated in the mass-selective instability mode depends on decreasing the rate of scanning the primary radio frequency amplitude as well as using resonance ejection at the appropriate frequency and amplitude. A theoretical basis for the method is introduced.  相似文献   

13.
The recent development of miniature ion trap mass spectrometer systems in the last ten years is reviewed in this paper. These instruments adopt different atmospheric pressure interfaces (APIs), which are membrane inlets (MIs), discontinuous atmospheric pressure interface (DAPI) and continuous atmospheric pressure interface (CAPI).  相似文献   

14.
In a digital ion trap (DIT), the quadrupole trapping and excitation waveforms are generated by the rapid switching between discrete d.c. voltage levels. As the timing of the switch can be controlled precisely by digital circuitry, the approach provides an opportunity to generate mass spectra by means of a frequency scan in contrast to the conventional voltage scan, thus providing a wider mass range of analysis. An instrument has been constructed which employs a 'non-stretched' ion trap and the field fault around the aperture of the end-cap electrode can be corrected electronically using a field-adjusting electrode. The ion trap was coupled with electrospray ionization (ESI) and atmospheric pressure matrix-assisted laser desorption/ionization (AP-MALDI) sources to demonstrate the capability of the digital method. AP-MALDI mass spectra of singly charged ions with mass-to-charge ratios upto 17 000 Th were generated using a trapping voltage of only 1000 V. Forward and reverse mass scans at resolutions up to 19 000 and precursor ion isolation at resolutions up to 3500 with subsequent tandem mass spectrometric analysis were demonstrated. The method of generating the digital waveforms and period scan is described. Discussion of the issues of mass range, scan speed, ion trapping efficiency and collision-induced dissociation efficiency are also provided.  相似文献   

15.
Combining source collision-induced dissociation (CID) and tandem mass spectral acquisition in a pseudo-MS(3) experiment using a linear ion trap results in a highly selective and sensitive approach to identifying glycopeptide elution from a protein digest. The increased sensitivity is partially attributed to the nonselective nature of source CID, which allows simultaneous activation of all charge states and coeluting glycoforms generating greater ion abundance for the mass-to-charge (m/z) 204 and/or 366 oxonium ions. Unlike source CID alone, a pseudo-MS(3) approach adds selectivity while improving sensitivity by eliminating chemical noise during the tandem mass spectral acquisition of the oxonium ions in the linear ion trap. Performing the experiments in the hybrid linear ion trap/Fourier transform-ion cyclotron resonance (FT-ICR) enables subsequent high-resolution/high-mass accuracy full-scan mass spectra (MS) and parallel acquisition of MS/MS in the linear ion trap to be completed in 2 s directly following the pseudo-MS(3) scan to collate identification and characterization of glycopeptides in one experimental scan cycle. Analysis of bovine fetuin digest using the combined pseudo-MS(3), high-resolution MS, and data-dependent MS/MS events resulted in identification of four N-linked and two O-linked glycopeptides without enzymatic cleavage of the sugar moiety or release of the sialic acids before analysis. In addition, over 95% of the total protein sequence was identified in one analytical run.  相似文献   

16.
17.
Ion ejection from a cylindrical micro ion trap by resonance excitation of the secular motion is observed to be strongly dependent on the frequency of the secular motion at resonance. Both the intensity of the ion signal and the mass resolution of the resulting mass spectrum are increased when the ion secular frequency is approximately that of a nonlinear resonance of the trap. The resonances are attributed to electrical as well as geometrical considerations.  相似文献   

18.
Characterization and assignment of the products of metastable decompositions which are transmitted by a double focusing mass spectrometer, is often complicated by the inability to measure precisely the parent/daughter ion mass values directly from the spectra which appear on chart paper. This is often because there are considerably fewer peaks in these types of spectra compared with a normal mass spectrum obtained from high energy reactions in the ion source. Electronic circuits are described which permit accurate parent/daughter ion mass values to be obtained when the products of metastable decompositions are transmitted through the ZAB-2F double focusing mass spectrometer. Digital logic circuitry is also described which is used to mark mass values during a scan by driving either a solenoid pen drive unit for a chart recorder or a galvanometer on a multi-range ultraviolet oscillograph recorder.  相似文献   

19.
A systematic study of the fragmentation pattern of phosphopeptides in an electrospray (ESI) ion trap mass spectrometer is presented. We show that phosphotyrosine- and phosphothreonine-containing peptides show complicated fragmentation patterns. These phosphopeptides were observed to lose the phosphate moiety in the form of H3PO4 and/or HPO3, but were also detected with no loss of the phosphate group. The tendency to lose the phosphate moiety depends strongly on the charge state. Thus, the highest observed charge state tends to retain the phosphate moiety with extensive fragmentation along the peptide backbone. We also show that phosphoserine-containing peptides have relatively simple fragmentation patterns of losing H3PO4. This loss is independent of the charge state. We suggest strategies for the accurate identification of phosphorylation sites using the ion trap mass spectrometer.  相似文献   

20.
An open-ended cylindrical cell with a single annular trap electrode located at the center of the excitation and detection region is demonstrated for Fourier transform ion cyclotron resonance mass spectrometry. A trapping well is created by applying a static potential to the trap electrode of polarity opposite the charge of the ion to be trapped, after which conventional dipolar excitation and detection are performed. The annular trap electrode is axially narrow to allow the creation of a potential well without excessively shielding excitation and detection. Trapping is limited to the region of homogeneous excitation at the cell centerline without the use of capacitive coupling. Perfluorotributylamine excitation profiles demonstrate negligible axial ejection throughout the entire excitation voltage range even at an effective centerline potential of only ?0.009 V. High mass resolving power in the single-trap electrode cell is demonstrated by achievement of mass resolving power of 1.45 × 106 for benzene during an experiment in which ions created in a high pressure source cubic cell are transferred to the low pressure analyzer single-trap electrode cell for detection. Such high performance is attributed to the negligible radius dependent radial electric field for ions cooled to the center of the potential well and accelerated to less than 60% of the cell radius. An important distinction of the single-trap electrode geometry from all previous open and closed cell arrangements is exhibition of combined gated and accumulated trapping. Because there is no potential barrier, all ions penetrate into the trapping region regardless of their translational energy as in gated trapping, but additional ions may accumulate over time, as in accumulated trapping. Ions of low translational kinetic energy are demonstrated to be preferentially trapped in the single-trap electrode cell. In a further demonstration of the minimal radial electric field of the single-trap electrode cell, positive voltages can be applied to the annular trap electrode as well as the source cell trap electrode to achieve highly efficient transfer of ions between cells.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号