首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Ion-exclusion/anion-exchange chromatography(IEC/AEC) on a combination of a strongly basic anion-exchange resin in the OH——form with basic eluent has been developed.The separation mechanism is based on the ion-exclusion/penetration effect for cations and the anion-exchange effect for anions to anion-exchange resin phase.This system is useful for simultaneous separation and determination of ammonium ion(NH+4),nitrite ion(NO-2),and nitrate ion(NO-3) in water samples.The resolution of analyte ions can be manipulated by changing the concentration of base in eluent on a polystyrene-divinylbenzene based strongly basic anion-exchange resin column.In this study,several separation columns,which consisted of different particle sizes,different functional groups and different anion-exchange capacities,were compared.As the results,the separation column with the smaller anion-exchange capacity(TSKgel Super IC-Anion) showed well-resolved separation of cations and anions.In the optimization of the basic eluent,lithium hydroxide(LiOH) was used as the eluent and the optimal concentration was concluded to be 2 mmol/L,considering the resolution of analyte ions and the whole retention times.In the optimal conditions,the relative standard deviations of the peak areas and the retention times of NH+4,NO-2,and NO-3 ranged 1.28%-3.57% and 0.54%-1.55%,respectively.The limits of detection at signal-to-noise of 3 were 4.10 μmol/L for NH+4,1.87 μmol/L for NO-2 and 2.83 μmol/L for NO-3.  相似文献   

2.
Hong Yu  Ruishu Li 《Chromatographia》2008,68(7-8):611-616
An investigation has been conducted into the effect of column temperature on the retention of inorganic anions and organic acids in non-suppressed ion chromatography on an anion-exchange column. Potassium biphthalate and p-hydroxybenzoic acid–tris–boric acid were used as mobile phases. The column temperature was from 25 to 50 °C. Endothermic and exothermic retention of inorganic anions were both observed when potassium biphthalate was used as mobile phase. When p-hydroxybenzoic acid–tris–boric acid was used as mobile phase, however, endothermic behavior only was observed. Moreover, for the two mobile phases, variation of the retention time of the system peaks with changing temperature was reversed. For retention of the organic acids, only endothermic behavior was observed with the two mobile phases. Variation of retention time was greater when p-hydroxybenzoic acid–tris–boric acid was used as mobile phase than when potassium biphthalate was used. These results indicated the exchange reaction in anion-exchange chromatography could be either endothermic or exothermic, depending on the solute and mobile phase ions involved. Different relative changes of retention time were observed for individual inorganic anions and organic acids with increasing column temperature. In general, variation of retention time with increasing temperature was greater for strongly retained inorganic anions and organic acids than for weakly retained species. Van’t Hoff plots for inorganic anions, organic acids, and system peaks were linear. Selectivity variation of the retention of inorganic anions and organic acids was achieved by changing the temperature. In achieving optimum separation of inorganic anions and organic acids, temperature was a valuable tool. To reduce the retention times of the ions and avoid interference from system peaks in non-suppressed anion-exchange ion chromatography with the two mobile phases, a low column temperature, for example, 35 °C, was best.  相似文献   

3.
Methods for separation of ions by ion-exchange, ion-pair, and zwitterion ion chromatography share at least one common thread--the induced formation of a cation-anion pair in the stationary phase. Selectivity can be defined as the relative ability of sample ions to form such a pair. Examples are given in anion-exchange chromatography to show the effect of variations in the geometry, bulkiness and polarity of the resin cation on selectivity. The type of resin matrix, the hydrophobic nature of the resin surface and the degree of solvation also affect chromatographic behavior. The selectivity series observed in ion chromatography seems to be best explained by the interplay of two components: electrostatic attraction (ES) and the enforced-pairing (EP) that is brought about by hydrophobic attraction and by water-enforced ion pairing. Selectivity in ion-pair chromatography (IPC) and in zwitterion ion chromatography (ZIC) is affected by both the mobile phase cation and anion. This leads to elution orders for anions that are different from conventional ion-exchange chromatography (IC) of anions where cations are excluded from the stationary phase and have little effect on a separation. The elution order of anions in ZIC is similar to that in IC except for small anions of 2-charge, which are retained more weakly in ZIC. A unique advantage of ZIC is that sample ions can be eluted as ion pairs with pure water as the eluent and a conductivity detector. The mechanism for separation of anions on a zwitterionic stationary phase has been a subject for considerable debate. The available facts point strongly to a partitioning mechanism or a mixed mechanism in which partitioning is dominant with a weaker ion-exchange component.  相似文献   

4.
离子色谱法分析金属离子的研究进展   总被引:3,自引:0,他引:3  
于泓  王宇昕 《色谱》2007,25(3):303-309
综述了离子色谱法(IC)分析金属离子的研究进展,对目前应用于分析金属离子的阳离子交换IC、阴离子交换IC和螯合离子色谱进行了评述。阳离子交换IC是IC分析金属离子的主要形式,固定相为强酸(磺酸)型阳离子交换剂和弱酸(羧酸)型阳离子交换剂,结合适当的检测方法,阳离子交换IC可以测定碱金属、碱土金属、过渡金属、稀土离子、铵离子及低相对分子质量的有机胺类分子等。阴离子交换IC可以分析碱土金属、过渡金属、稀土离子等,对金属离子的分析具有更好的选择性,并可以实现金属离子和无机阴离子的同时测定。螯合离子色谱可以对复杂基体中的痕量金属离子进行测定。引用文献125篇。  相似文献   

5.
Methyl-capped poly(ethylene oxide) moieties were chemically bonded to silica gel using an amine-reactive modification reagent and evaluated as the stationary phase for ion chromatography. In this work, primary amino groups of an aminopropylsilica packing material were reacted with methyl-PEO12-NHS ester (succinimidyl-{[N-methyl]-dodecaethyleneglycol} ester) in phosphate buffer (pH 7.0) at room temperature. The prepared poly(ethylene oxide)-bonded stationary was evaluated for the separation of inorganic anions, and the retention behavior of inorganic anions on the prepared stationary phase was examined. The elution order of the investigated anions was the same as that observed in common ion chromatography. Both cations and anions of the eluent affected the retention of the analyte anions. Ion exchange was involved for the retention of analyte anions, although the present stationary phase does not possess any discrete ion-exchange sites. The stationary phase was applied to the separation of trace anions contained in tap water and a rock salt.  相似文献   

6.
An ion chromatographic method was developed for the determination of nine inorganic and organic acid anions at sub- to low-microg/l levels in power plant water samples. In this method, samples were injected using a large-volume direct injection technique, the analyte anions were separated on a hydroxide-selective anion-exchange column using high-purity hydroxide eluents generated by an on-line electrolytic eluent generator and detected using the suppressed conductivity detection method. The method performance was evaluated by analyzing synthetic water samples containing additives encountered in the power plant water samples and four water samples from a fossil fuel power plant. The relative standard deviations of retention times of analyte ions separated on the hydroxide-selective anion-exchange column were less than 0.4%. The recoveries of analyte ions spiked into the synthetic water samples at concentrations of 0.13-1.0 microg/l were in the range of 70-120%. The method detection limits for analyte ions in deionized water were 0.0099, 0.0056, 0.019, 0.057, 0.0084, 0.023, 0.067, 0.037, and 0.079 microg/l for fluoride, acetate, formate, chloride, nitrite, sulfate, bromide, nitrate, and phosphate, respectively.  相似文献   

7.
Abstract

Alkyl-modified silica (RSi) and polystyrenedivinylbenzene (PRP-1) stationary phases are compared for the chromatographic separation of inorganic analyte anions and cations using hydro-phobic ions of opposite charge as mobile phase additives. Tetra-alkylammonium salts were used for anion separations and alkyl sulfonate salts for cation separations. Two major equilibria influence the retention of analyte ions on PRP-1. These are: retention of the hydrophobic ion on PRP-1 and an ion exchange selectivity between the hydrophobic counterion and the analyte ion. When using RSi retention is also influenced by ion exchange at residual silanol groups, which act as weak cation exchange sites. Mobile and stationary phase variables that influence analyte retention are identified. Optimization of these provides favorable eluting conditions for the separation of inorganic ionic analytes. Of particular interest is the potential use of PRP-1 and RSi columns for the separation of inorganic cations; conditions for the separation of alkali metals and alkaline earths are discussed.  相似文献   

8.
A vitamin U-bonded stationary phase was prepared and the retention behavior of inorganic anions was examined using ion chromatography. Inorganic anions were retained on the vitamin U-bonded stationary phase under acidic as well as neutral eluent conditions in the ion-exchange mode. The elution order of the examined anions under neutral eluent conditions was nearly the same as that observed in common ion exchange mode, while the elution order observed under acidic eluent conditions was completely different from that observed in common ion exchange mode. The retention of the analyte anions under the neutral eluent conditions was due to the sulfonium groups of the vitamin U, while protonated primary amino groups caused retention of the analyte anions with different selectivity under acidic conditions. The retention factor of the analyte anions increased with decreasing eluent concentration under both eluent conditions. The present system was applied to the determination of bromide and nitrate contained in seawater.  相似文献   

9.
A retention model based on stoichiometric approach has been developed in order to describe analyte retention of anions on latex-based pellicular ion exchanger. The chromatographic process entails two stepwise and complex equilibria, first is ion-pair forming of analyte or eluent ion with ion-exchange sites under the effect of electrostatic forces due to the sulfonic layer behind the aminated functional groups of stationary phase. Second component is the ion-exchange between the analyte and eluent ions. As a new parameter of the fractional electrostatic coefficient of the ion exchange capacity was introduced to develop retention profiles of anions. Analysis of the dependence of the capacity factors on the eluent concentrations at different values of fractional coefficient shed light on the possible complex mechanism. Extensive experimental retention data were obtained for 14 anions (formate, acetate, propionate, pyruvate, lactate, chloride, nitrate, oxalate, malonate, succinate, tartarate, fumarate, maleate, sulphate) using hydroxide eluents of varying concentration. The ion-pair formation and ion-exchange selectivity constants for analyte and eluent species are determined using derived retention equation from experimental data by nonlinear iterative calculation. The model was utilized to predict retention data under elution conditions of practical importance. The predicted and obtained retention factors are in good agreement, which confirms the predictive power of the model.  相似文献   

10.
Several procedures are available for simulating and optimising separations in ion chromatography (IC), based on the application of retention models to an extensive database of analyte retention times on a wide range of columns. These procedures are subject to errors arising from batch-to-batch variability in the synthesis of stationary phases, or when using a column having a different diameter to that used when the database was acquired originally. Approaches are described in which the retention database can be recalibrated to accommodate changes in the stationary phase (ion-exchange selectivity coefficient and ion-exchange capacity) or in the column diameter which lead to changes in phase ratio. The entire database can be recalibrated for all analytes on a particular column by performing three isocratic separations with two analyte ions. The retention data so obtained are then used to derive a "porting" equation which is employed to generate the required simulated separation. Accurate prediction of retention times is demonstrated for both anions and cations on 2mm and 0.4mm diameter columns under elution conditions which consist of up to five sequential isocratic or linear gradient elution steps. The proposed approach gives average errors in retention time prediction of less than 3% and the correlation coefficient was 0.9849 between predicted and observed retention times for 344 data points comprising 33 anionic or cationic analytes, 5 column internal diameters and 8 complex elution profiles.  相似文献   

11.
Neutral hydrophobic hypercrosslinked polystyrene was shown to exhibit anion-exchange properties in the pH range 2.6-4.3 that can be attributed to the presence of protonated carbonyls in the framework of the polymer. This resin does not contain any other heteroatoms, except oxygen, responsible for the occurrence of positive charge at the surface. The anion-exchange selectivity of MN-200 and monosized spherical hypercrosslinked polystyrene to inorganic anions with diluted perchloric, nitric and sulfuric acid solutions as eluent was studied and the selectivity was found to be different from that observed for the common anion-exchangers. The main features of hypercrosslinked polystyrene are weak retention of sulphate and comparatively strong retention of nitrite that can be useful in practical ion chromatography. The influence of column temperature on the retention was investigated. Calculated adsorption heats are in the range from -2 to 19 kJ/mol. The retention mechanism of inorganic anions on neutral hypercrosslinked polystyrene includes both ion-exchange and hydrophobic interactions.  相似文献   

12.
Electrostatic ion chromatography, also known as zwitterionic ion chromatography, has been predominantly used for the analysis of anions. Consequently, separation mechanisms proposed for this technique have been based on anion retention data obtained using a sulfobetaine-type surfactant-coated column. A comprehensive cation retention data set has been obtained on a C18 column coated with the zwitterionic surfactant N-tetradecylphosphocholine (which has the negatively and positively charged functional groups reversed in comparison to the sulfobetaine surfactants), with mobile phases being varied systematically in the concentration and species of both the mobile-phase anion and cation. A retention mechanism based on both an ion exclusion effect and a direct (chaotropic) interaction with the inner negative charge on the zwitterion is proposed for the retention of cations. Despite the relatively low chaotropic nature of cations compared with anions, the retention data shows that cations are retained in this system predominantly due to a chaotropic interaction with the inner charge, analogous to anions in a system where the C18 column is coated with a sulfobetaine-type surfactant. The retention of an analyte cation, and the effect of the mobile-phase anion and cation, can be predicted by the relative positions of these species on the Hofmeister (chaotropic) series.  相似文献   

13.
A mixed-mode chromatography coupled with charged aerosol detector (CAD) method was developed in this work to simultaneously determine pharmaceutical counterions including both inorganic ions and organic ions in the forms of cations and anions. 25 commonly used pharmaceutical ions were studied and simultaneously separated within 20 min by this single method. A silica based mixed-mode column with reversed-phase/cation-exchange/anion-exchange modes was used. It provides reversed-phase, strong cation-exchange and weak anion-exchange properties at the same time. It also provides the HILIC behavior at high percentage of organic solvent. The effects of mobile-phase organic strength, buffer ions, ionic strength, pH and column temperature have been investigated to optimize the method as well as to understand the retention and separation mechanisms. Conventional HPLC system was used and no special chromatography system is needed. The presented method has been employed successfully for screening and quantitative analysis of counterions, unknown ionic impurities and salts in active pharmaceutical ingredients and in process control samples with excellent accuracy, precision and sensitivity. This method provides a simple, fast and generic approach to speed up pharmaceutical research and development process and enhance lab efficiency. The similar methodologies can be applied to other ion analysis.  相似文献   

14.
Arai K  Mori M  Hironaga T  Itabashi H  Tanaka K 《色谱》2012,30(4):404-408
A combination of hydrophilic interaction chromatographic(HILIC) column and a weakly acidic cation-exchange resin(WCX) column was used for simultaneous separation of inorganic anions and cations by ion chromatography(IC).Firstly,the capability of HILIC column for the separation of analyte ions was evaluated under acidic eluent conditions.The columns used were SeQuant ZIC-HILIC(ZIC-HILIC) with a sulfobetaine-zwitterion stationary phase(ZIC-HILIC) and Acclaim HILIC-10 with a diol stationary phase(HILIC-10).When using tartaric acid as the eluent,the HILIC columns indicated strong retentions for anions,based on ion-pair interaction.Especially,HILIC-10 could strongly retain anions compared with ZIC-HILIC.The selectivity for analyte anions of HILIC-10 with 5 mmol/L tartaric acid eluent was in the order of I-> NO-3 > Br-> Cl-> H2PO-4.However,since HILIC-10 could not separate analyte cations,a WCX column(TSKgel Super IC-A/C) was connected after the HILIC column in series.The combination column system of HILIC and WCX columns could successfully separate ten ions(Na+,NH+4,K+,Mg2+,Ca2+,H2PO-4,Cl-,Br-,NO-3 and I-) with elution of 4 mmol/L tartaric acid plus 8 mmol/L 18-crown-6.The relative standard deviations(RSDs) of analyte ions by the system were in the ranges of 0.02%-0.05% in retention times and 0.18%-5.3% in peak areas through three-time successive injections.The limits of detection at signal-to-noise ratio of 3 were 0.24-0.30 μmol/L for the cations and 0.31-1.2 μmol/L for the anions.This system was applied for the simultaneous determination of the cations and the anions in a vegetable juice sample with satisfactory results.  相似文献   

15.
New stationary phases for chromatographic separation of anions, obtained by loading liposomes made from dimyristolyphosphatidylcholine (DMPC) onto reversed-phase packed columns (C18 and C30) are reported. Mono- and divalent anions were used as model analyte ions and retention data for these species were obtained using the DMPC stationary phases and used to elucidate the separation mechanisms involved in this chromatographic system. The DMPC stationary phases can separate anions by either a solvation-dependent mechanism or an electrostatic ion-exchange mechanism, depending upon the relative magnitudes of the negative electrostatic potential (Psi(-)) of the phosphate moiety (P-) and the positive electrostatic potential (Psi(+)) of the quaternary ammonium groups (N+) on the headgroup of DMPC. If Psi(+) > Psi(-), such as in case where Psi(-) has been reduced either by binding of eluent cations (e.g., H+ or divalent cations) onto the P- group of DMPC or by steric screening when a C30 reversed-phase material was used to support the DMPC, then the overall electrostatic surface potential (and hence also the effective anion-exchange capacity) was generally large and the anions were separated on the basis of an electrostatic mechanism. However, if Psi(+) was similar to Psi(-), such as in the case of using a C18 reversed-phase support and monovalent cations as eluent cations, then the overall electrostatic surface potential and the effective anion-exchange capacity were very small and the analyte anions were separated on the basis of a solvation-dependent mechanism. The DMPC stationary phases were found to be suitable for the direct determination of iodide and thiocyanate in highly saline water samples, such as seawater samples.  相似文献   

16.
Separation of twelve enkephalins was investigated on a quaternary ammonium-embedded stationary phase (Stability BS-C23). Variation of buffer pH of the mobile phase highlighted the complex relationship between repulsive/attractive electrostatic interactions and the reversed-phase partitioning mechanism. The effect of three different anions employed as additives (phosphate, chloride and perchlorate) was examined at various concentrations and two pH values (acidic and neutral). At pH 2.5, an increase in the anion eluent concentration resulted in a higher retention factors of positively charged enkephalins. This effect was more pronounced when perchlorate ions were added to the mobile phase rather than phosphate and chloride ions, due to chaotropic and ion-pairing effects. In contrast, at pH 7.5, retention factors of negatively charged enkephalins decreased when these salts were added, due to an anion-exchange mechanism. Perchlorate caused a sharper decrease than chloride and phosphate anions did. The results presented here provide insight into the possible adjustment of retention and separation of peptides on a mixed-mode stationary phase (BS-C23) by a careful control of the buffer pH, the nature and concentration of anions, added to the buffer, and organic modifier content.  相似文献   

17.
A particle beam interface was investigated for coupling ion chromatography with mass spectrometric detection. Several prerequisites must be fulfilled, including mobile phases containing volatile buffers and high amounts of organic solvents at low flow-rates. Microcolumns with inner diameters between 130 and 1000 μm (packed with a silica-based anion-exchange material) in combination with a microflow aerosol generator meet these requirements. Organic solvetns in the mobile phase lead to considerable changes in separation selectivity, so that the retention order can be partly reversed in comparison with aqueous mobile phases. The performance of the interface and the mass spectrometric detection has been studied for a series of inorganic anions as well as for aminopolycar☐ylic acids and their metal complexes. The detection limits are between 10 and 100 ng injected and are significantly poorer than those for conductivity detection. On the other hand, the possibility of operating the detector at pre-selected masses greatly improves the selectivity of the analysis and helps to confirm peaks from a non-selective conductivity detector. On-line and off-line preconcentration techniques allow the detection of anions in drinking water at ppb levels.  相似文献   

18.
In anion-exchange chromatography using a high-concentration eluent and high-capacity ion-exchange resin, the effect of the countercation contained in the eluent was investigated. Cadmium(II) and zinc(II) ions were examined as additives in an aqueous potassium chloride eluent. The addition of these cations resulted in a reversed elution order of bromide and nitrate, as compared with conventional anion-exchange chromatography. The separation factor for these two anions increased as the cadmium concentration in the eluent was increased. Zinc(II) ion was also effective, but a relatively high concentration was necessary.  相似文献   

19.
A novel stationary phase — phenylaminopropyl (PLA) bonded silica — is proposed for anion-exchange chromatography. Low basicity (pKa about 2.5) attached to silica phenylaminopropyl groups allows a variation of surface density of protonated sites in the pH range from 2 to 5. This enables us to use the same column for the separation of anions having different affinity to anion-exchangers. The effect of mobile phase pH on conditional capacity of PhA-silica was studied. The hypothesis on dependence of ion-exchange selectivity on the column capacity is discussed. Suitability of PhA-silica for ion-chromatographic separation of organic and inorganic anions at different pH values of eluent was demonstrated.  相似文献   

20.
A method for the superheated water chromatography of phenols was developed using a poly(styrene-divinylbenzene) (PSDVB) stationary phase. The stationary phase of superheated water chromatography must be stable against the attack of water. A durability test for PSDVB packings and octadecylsilyl (ODS)-silica gels indicated that PSDVB packings were stable in superheated water in the temperature range of 100-150 degrees C, whereas octadecylsilyl groups of ODS-silica gels cleaved even at 100 degrees C. The retention of phenols on the PSDVB stationary phase decreased with an elevation of the column temperature. The retention mechanism was characterized using a thermodynamic theory that has been used for describing retention in conventional RP-HPLC. The application of the present method to an environmental analysis was also demonstrated, in which a suitable separation with good peak shape was obtained for p-chlorophenol in river-water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号