首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Bacigalupo MA  Ius A  Longhi R  Meroni G 《Talanta》2003,61(4):539-545
Atrazine (Atr) was conjugated to mastoparan (Mast) cytolytic peptide; Mast-Atr derivative was used as cytolytic agent on liposomes trapping Tb/citrate complex. This was applied in a time-resolved fluoroimmunoassay for detection of Atr in water. The cytolytic activity was read by means of time-resolved fluorescence after adding an excess of dipicolinic acid (DPA). Tb/citrate-entrapping liposomes are easy to prepare, and the assay is carried out in a short incubation time and in a range between 10 pg and 100 ng. The procedure was applied to analyse samples taken from Adda River and from irrigation ditches in an agricultural area around the town of Lodi. Recovery in samples spiked with two different Atr concentrations was between 95 and 105%.  相似文献   

2.
We report on the use of a natural Lewis type saccharide ligand, 3′-sulfo-Lewis a (SuLea) for glycocalyx-mimetic surface modification of liposomes. Two SuLea-containing glycolipids, monovalent SuLea-lipid and trivalent SuLea (TSuLea)-lipid, were synthesized, and used with 1,2-distearoyl-sn-glycero-3-phosphocholine (DSPC) and cholesterol to prepare unilaminar vesicles (ULVs) by a freeze–thaw and extrusion method. The effects of the glycolipid concentrations and the pore sizes of extrusion membranes on vesicle size and stability were investigated by photon correlation spectroscopy (PCS). Glycoliposomes, with 5% SuLea- or TSuLea-lipids obtained by 50 nm extrusion, had 25–30% more vesicles less than 100 nm in diameter compared with the 100 nm extrusion. TSuLea-liposomes always produced larger vesicle size than SuLea-liposomes, which we attribute to the larger TSuLea headgroup. Both SuLea- and TSuLea-liposomes increased their vesicle size with increasing glycolipid concentration from 5% to 15%, and demonstrated good stability at room temperature for over 1 month. Further increasing the glycolipid concentration to 20% resulted in large vesicle aggregation after 5 days for TSuLea-liposomes, while the SuLea-liposomes remained stable for 10 days. SuLea- and TSuLea-liposomes with 15% glycolipids demonstrated better stability due to the electrostatic effect from the negatively charged SuLea and TSuLea headgroups. The results indicate that the biomimetic liposomes with SuLea- and TSuLea-lipids with 5 to 15% incorporation are sufficiently stable for the potential applications in targeted drug delivery.  相似文献   

3.
The on-line column preconcentration technique with inductively coupled plasma optical emission spectroscopy (ICP–OES) has been developed using a cartridge filled with octadecyl silica modified by l-(2-pyridylazo) 2-naphtol (PAN). The aim of this method was to determine some rare earth elements (REEs) (Ce, Dy, La, Sm, and Y) and uranium in water samples. Sample solutions were passed through the C18-modified column. The adsorbed cations were subsequently eluted from the column and transferred into the plasma with nitric acid solution for simultaneous determination of them. Sample pH, amount of PAN as a complexing agent, sampling and eluting flowrates and concentration of the eluent were optimized. Detection limits based on three times of standard deviations of blank by 10 replicates were in the range of 11 ng l−1 for Dy to 69 ng l−1 for U. Sample throughput was 10 samples h−1. The proposed method was applied to determine REEs in natural water samples. Recoveries of the REEs from natural water samples were between 95 and 106% with percent relative standard deviation (%R.S.D.) of 1.0–7.9%.  相似文献   

4.
Development of an enzyme-linked immunosorbent assay for pentachlorophenol   总被引:5,自引:0,他引:5  
Pentachlorophenol (PCP) is a hazardous pollutant with toxicity and potential carcinogenic properties being a serious threat to the environment. In this work, the development of an immunoassay for PCP is presented. A hapten was synthesised and conjugated to protein for rabbit immunisation. Three polyclonal antibodies were obtained and the best results were achieved in the antibody-coated format using antiserum R3. Calibration range was 0.3–30.5 ng ml−1, with an average I50 value of 2.9 ng ml−1 and a detection limit of 0.1 ng ml−1. The specificity of the assay was tested against PCP structurally related compounds. The method is highly specific for PCP and shows low cross-reactivity (CR) for chlorine-containing phenols, nitrophenols, benzenic and piridinic compounds. The good recoveries achieved with different water samples indicate that this assay can be a good alternative method for the determination of PCP in this kind of samples.  相似文献   

5.
An enzyme-based microtiter plate assay for γ-aminobutyric acid (GABA) was developed. GABA was quantified using γ-aminobutyrate glutamate aminotransferase and succinic semialdehyde dehydrogenase in the presence of NADP+ and -ketoglutarate. The NADPH produced by the series of enzymatic reactions was measured spectrophotometrically at 340 nm. A linear relationship between absorbance and the concentration of GABA was obtained in the ranges from 5.0 × 10−4 to 1.0 × 10−2 M. The relative standard deviation for 10 successive measurements was 0.9% at the 10 mM GABA level. This analytical method was applied to the screening of GABA-producing lactic acid bacteria in de Man–Rogosa–Sharpe (MRS) medium. The proposed method enables one to assay 96 samples for an hour without the pre-treatment of samples. The method is by far superior to the traditional HPLC method from the point of view of rapidity and simplicity.  相似文献   

6.
A novel method for the spectrophotometric determination of nitrite in water   总被引:4,自引:0,他引:4  
Aydın A  Ercan O  Taşcıoğlu S 《Talanta》2005,66(5):1181-1186
A rapid, simple, selective and sensitive method for the spectrophotometric determination of nitrite in water has been developed and optimum reaction conditions along with other analytical parameters have been evaluated. Nitrite reacts with barbituric acid in acidic solution to give the nitroso derivative, violuric acid. At analytical wavelength of 310 nm, Beer's law is obeyed over the concentration range 0.00–3.22 ppm of nitrite. The molar absorptivity is 15330 ± 259.7 (95%) with pooled standard deviation of 355.57 and R.S.D. of 2.32%. As well as the method is sensitive (2.99 × 10−3 μg NO2 cm−2) and selective, it tolerates most of the potential interferents. It has been successfully applied to nitrite determination in natural waters by use of a calibration graph with determination limit of 1.66 μg NO2 in 100 mL working solution corresponding to minimum 9.5 ppb NO2–N in water samples. Lower concentrations of nitrite (3.0 μg NO2/L sample) is precisely analyzed by using the method of dilution with sample, with R.S.D. of lower than 0.5%. The results were compared with standard N-(1-naphtyl)ethylenediamine dihydrochloride method and very good agreement between the data was observed. The method can easily be applied in the field.  相似文献   

7.
Hong Dinh Duong  Jong Il Rhee   《Talanta》2007,73(5):899-905
In the present work, CdSe/ZnS core-shell quantum dots were synthesized and conjugated with enzymes, glucose oxidase (GOD) and horseradish peroxidase (HRP). The complex of enzyme-conjugated QDs was used as QD-FRET-based probes to sense glucose. The QDs were used as an electron donor, whereas GOD and HRP were used as acceptors for the oxidation/reduction reactions involved in oxidizing glucose to gluconic acid. Electron transfer between the redox enzymes and the electrochemical reduction of H2O2 (or O2) occurred rapidly, resulting in an increase of the turnover rate of the electron exchange between the substrates (e.g. glucose, H2O2 and O2) and the enzymes (GOD, HRP), as well as between the QDs and the enzymes. The transfer of non-radiative energy from the QDs to the enzymes resulted in the fluorescence quenching of the QDs, corresponding to the increase in the concentration of glucose. The linear detection ranges of glucose concentrations were 0–5.0 g/l (R = 0.992) for the volume ratios of 10/5/5, 0.2–5.0 g/l (R = 0.985) for the volume ratios of 10/5/3 and 1.0–5.0 g/l (R = 0.982) for the volume ratios of 10/5/0. Temperature (29–37 °C), pH (6–10) and some ions (NH4+, NO3, Na+, Cl) had no interference effect on the glucose measurement.  相似文献   

8.
Cadmium concentration in lake sediments is determined by suspending the solid samples in a solution containing 5% (v/v) concentrated nitric acid and 0.1% (v/v) Triton X-100. Three modifiers were tested for the direct determination. The furnace temperature programmes and appropriate amount for each modifier were optimised to get the highest signal and the best separation between the atomic and background signals. The drying stage is performed by programming a 400 °C temperature, a ramp time of 25 s and hold time of 10 s on the power supply of the atomiser. No ashing step is used and platform atomisation is carried out at 2200 °C. W–Rh permanent modifier combined with conventional modifier by delivering 10 μl of 0.50% (w/v) NH4H2PO4 solution was the best chemical modifier for cadmium determination. This modifier also acts as a liquid medium for the slurry, thus simplifying the procedure. Calibration is performed using aqueous standards in the 1–5 μg l−1 range. The optimised method gave a limit of detection of 0.56 ng ml−1, characteristic mass of 10.1±0.8 pg for aqueous standard, 9.6±0.7 pg for slurry samples containing different Cd concentrations and good precision (7.6–5.2%). The method was validated by analysing four certified reference lake sediment materials: LKSD-1, LKSD-2, LKSD-3 and LKSD-4; satisfactory recoveries were obtained (90.0–96.3%) and no statistical differences were observed between the experimental and the certified cadmium concentration. The developed methodology was used to determine cadmium in three ‘real’ sediment samples from lakes in the area of Wielkopolski National Park, Poland.  相似文献   

9.
A new po1y(acrylphenylamidrazone phenylhydrazide) chelating fiber is synthesized from polyacrylonitrile fiber and used for preconcentration and separation of trace Ga(III), In(III), Bi(III), V(V) and Ti(IV) from solution (5–50 ng ml−1 Ti(IV) or V(V) and 50–500 ng ml−1 Ga(III), In (III) or Bi(III) in 1000–100 ml of solution can be enriched quantitatively by 0.15 g of fiber at a 4 ml min−1 flow rate in the pH range 5–7 with recoveries >95%). These ions can be desorbed quantitatively with 20 ml of 4 M hydrochloric acid at 2 ml min−1 from the fiber column. When the fiber which had been treated with concentrated hydrochloric acid and washed with distilled water until neutral was reused eight times, the recoveries of the above ions by enrichment were still >95%. Two-hundred-fold to 10 000-fold excesses of Cu(II), Zn(II), Ca(II), Mn(II), Cr(III), Fe(III), Ba(II) and Al(III) caused little interference in the determination of these ions by inductively coupled plasma-atomic emission spectrometers (ICP-AES). The relative standard deviations for enrichment and determination of 50 ng ml−1 Ga, In or Bi and 10 ng ml−1 V or Ti are in the range 1.2–2.7%. The contents of these ions in real solution samples determined by this method were in agreement with the certified values of the samples with average errors <3.7%.  相似文献   

10.
A pervaporation-flow injection (PFI) method is described for the analysis of cyanide in the presence of sulfide. The interfering sulfide ion in the injected sample is precipitated on-line using an acidified lead nitrate reagent solution before the donor stream enters the pervaporation cell. Using amperometric detection at a silver electrode set at −50 mV (vs Ag/AgCl), linear calibration was obtained in the range 0.02–100.0 mg l−1 with a detection limit of 1.0 μg l−1. Sample throughput was of the order of 12–15 h−1. When the method was applied to the analysis of synthetic samples, there was no significant interference from sulfide at concentrations up to 50 mg l−1. Thiocyanate did not interfere at levels up to 1000 mg l−1. When applied to industrial samples containing sulfide and thiocyanate ions where the cyanide ions are predominantly complexed with various metal ions the PFI method was found to give results close to those obtained by standard distillation methods for weak acid dissociable (WAD) cyanide.  相似文献   

11.
Sözgen K  Cekic SD  Tütem E  Apak R 《Talanta》2006,68(5):1601-1609
Total protein assay was made using copper(II)–neocuproine (Nc) reagent in alkaline medium (with the help of a hydroxide-carbonate-tartarate solution) after 30 min incubation at 40 °C. The absorbance of the reduction product, Cu(I)–Nc complex, was recorded at 450 nm against a reagent blank. The absorptivity of the developed method for bovine serum albumin (BSA) was 0.023 l mg−1 cm−1, greater than that of Lowry assay (0.0098), and much greater than that of Cu(II)–bicinchoninic acid (BCA) assay (0.00077). The linear range of the developed method (8–100 mg l−1 BSA) was as wide as that of Lowry, and much wider than that of BCA (200–1000 mg l−1 BSA) assay. The sensitivity of the method was greater than those of Cu-based assays (biuret, Lowry, and BCA) with a LOD of 1 mg l−1 BSA. The within-run and between-run precisions as RSD were 0.73 and 1.01%, respectively. The selectivity of the proposed method for protein was much higher than those of dye-binding and Lowry assays: Most common interferents to other protein assays such as tris, ethanolamine, deoxycholate, CsCl, citrate, and triton X-100 were tolerated at 100-fold concentrations in the analysis of 10 mg l−1 BSA, while the tolerance limits for other interferents, e.g., (NH4)2SO4 and acetylsalicylic acid (50-fold), SDS (25-fold), and glycerol (20-fold) were at acceptable levels. The redox reaction of Cu(II)–Nc as an outer-sphere electron transfer agent with the peptide bond and with four amino acid residues (cystine, cysteine, tryptophan, and tyrosine) was kinetically more favourable than that of Cu(II) alone in the biuret assay. Since the reduction product of Cu(II) with protein, i.e., Cu(I), was coordinatively saturated with Nc in the stable Cu(Nc)2+ chelate, re-oxidation of the formed Cu(I) with Fenton-like reactions was not possible, thereby preventing a loss of chromophore. After conventional protein extraction, precipitation, and redissolution procedures, the protein contents of the minced meat (veal and turkey), sardine, various milk products, and egg white were analyzed with the proposed and Lowry methods, and the results correlated appreciably (r = 0.98). The method was validated by Kjeldahl analyses of the tested samples; the data sets of complex samples assayed by Cu(II)–Nc and Lowry correlated to the findings of Kjeldahl yielded correlation coefficients r = 0.96 and 0.97, respectively, with slopes being close to 1. Interferences of glucose and thiol compounds at relatively low concentrations could be compensated for by selecting a lower alkaline pH (i.e., pH 10) at a cost of slightly reduced sensitivity and adding an identical amount of interferent to the reagent blank, respectively, since the absorbances due to BSA and interferent were additive. Thus a novel spectrophotometric method for total protein assay using a stable reagent and chromophore, which was simple, rapid, sensitive, flexible, and relatively selective, was developed, and applied to a variety of food products.  相似文献   

12.
A simple and rapid flow injection (FI) method is reported for the determination of phosphate (as molybdate reactive P) in freshwaters based on luminol chemiluminescence (CL) detection. The molybdophosphoric heteropoly acid formed by phosphate and ammonium molybdate in acidic conditions generated chemiluminescence emission via the oxidation of luminol. The detection limit (3× standard deviation of blank) was 0.03 μg P l−1 (1.0 nM), with a sample throughput of 180 h−1. The calibration graph was linear over the range 0.032–3.26 μg P l−1 (r2=0.9880) with relative standard deviations (n=4) in the range 1.2–4.7%. Interfering cations (Ca(II), Mg(II), Ni(II), Zn(II), Cu(II), Co(II), Fe(II) and Fe(III)) were removed by passing the sample through an in-line iminodiacetate chelating column. Silicate interference (at 5 mg Si l−1) was effectively masked by the addition of tartaric acid and other common anions (Cl, SO42−, HCO3, NO3 and NO2) did not interfere at their maximum admissible concentrations in freshwaters. The method was applied to freshwater samples and the results (26.1±1.1–62.0±0.4 μg P l−1) were not significantly different (P=0.05) from results obtained using a segmented flow analyser method with spectrophotometric detection (24.4±4.45–84.0±16.0 μg P l−1).  相似文献   

13.
A continuous flow system for the determination of lead in home made spirituous beverages was developed. The determination was based on the formation of a neutral chelate of the element with ammonium pyrrolidine dithiocarbamate, its adsorption onto a minicolumn packed with sodium faujasite type Y synthetic zeolite, followed by elution with methyl isobutyl ketone and determination by flame atomic absorption spectrometry. Ethanol and copper interfere strongly in the determination and therefore, must be separated prior to the analysis. Copper is removed by precipitation with rubeanic acid, while ethanol is eliminated by rotaevaporation. Sample solutions containing Pb2+ in the concentration range from 5 to 120 μg l−1 at pH 2.5 could be analyzed, by using a preconcentration time of 3 min. Preconcentration factors from 80 to 140 were achieved for a sample volume of 6 ml and the detection limit varied from 1.4 to 3.5 μg l−1, depending on the matrix composition. The relative standard deviations for 60 μg l−1 Pb was 3.2% (n = 10) and the recovery of spikes (20, 40, 60 and 80 μg l−1) added to the samples was estimated within 92–105% range, suggesting that lead can be quantitatively determined in such samples. Determining lead in several samples by an alternative technique further checked the accuracy. Finally, the concentrations of Pb2+ determined in 28 samples of Venezuelan spirituous beverages were in 12.6–370.0 μg l−1 range, depending on the fermenting material based on different mixtures of agave, raw sugar cane and white sugar.  相似文献   

14.
Guo R  Zhou Q  Cai Y  Jiang G 《Talanta》2008,75(5):1394-1399
A new method is developed for the determination of perfluorooctanesulfonate (PFOS) and perfluorooctanoic acid (PFOA) in sewage sludge samples. The analytes in sewage sludge samples are extracted by methanol and formic acid, cleaned by C18 solid-phase extraction, then separated, identified and quantitated by liquid chromatography/quadrupole time-of-flight mass spectrometry (LC–QTOF-MS). A C18 column (150 mm × 2.1 mm, 3.5 μm) with gradient elution of MeOH–H2O (60:40) containing 5 mmol/L ammonium acetate and MeOH–H2O (80:20) is used for the chromatographic separation. [M−K] ions at m/z 498.93 for PFOS and [M−COOH] ion at m/z 368.97 for PFOA are selected for QTOF-MS in the negative electrospray ionization mode. The detection limits for PFOS and PFOA in sewage sludge samples are 0.5 and 0.8 ng/g, respectively. The spiked recoveries are in the range of 85–114 and 71–98% for PFOS and PFOA, respectively. The proposed method is successfully applied to the analysis of PFOS and PFOA in 16 sewage sludge samples from China. PFOS and PFOA are detected in most sewage sludge samples and the concentrations of PFOS and PFOA are up to 5383 and 4780 ng/g (oven dry weight), respectively.  相似文献   

15.
Cui X  Fang G  Jiang L  Wang S 《Analytica chimica acta》2007,590(2):2139-259
A simple and sensitive kinetic-spectrophotometric method was developed for the determination of ultra trace amount of formaldehyde in food samples. The method was based on the oxidation of rhodamine B (RhB) by potassium bromate in sulfuric acid medium (formaldehyde as catalyst). The reaction was monitored by measuring the decrease in absorbance of the dye at 515 nm after 6 min. The developed method allowed the determination of formaldehyde in the range of 10–100 μg L−1 with good precision, accuracy and the detection limit was down to 2.90 μg L−1. The relative standard deviations for the determination of 10 and 60 μg L−1 of formaldehyde were 3.0% and 1.9% (n = 10), respectively. The method was found to be sensitive, selective and was applied to the determination of formaldehyde in foods with satisfactory results.  相似文献   

16.
The effect of arsenate on phosphate determination by the malachite green spectrophotometric method was investigated. The molar absorptivities of the molybdophosphate and malachite green–molybdoarsenate species at 625 nm and a final acidity of 0.38 M were calculated as 10.4±0.13×104 and 7.2±0.17×104 l mol−1 cm−1 respectively, indicating that arsenate could interfere in phosphate measurement. Arsenate concentrations as low as 23 μg l−1 caused increase in colour development in phosphate solutions. However, the extent of colour development for both anions depended on the final acid concentration of the solution. An acidified sodium sulphite solution (0.83 M NaSO3, 0.83 M H2SO4) quantitatively prevented arsenate colour development up to 300 μg l−1 As(V). It was also demonstrated that the method removed As(V) interferences in mixed As/P solutions and therefore can be used to treat natural water samples with elevated arsenate concentrations before phosphate measurement.  相似文献   

17.
Raman spectra were measured of highly fluorinated graphite samples prepared at room temperature, 380 and 515 °C. CxF prepared at room temperature showed a novel downshifted band at 1555–1542 cm−1 along with G band at 1593–1583 cm−1. Similar behavior is also observed for samples prepared at 380 and 515 °C at early stages of fluorination, after which the Raman shifts completely disappeared. Raman spectra as well as X-ray diffraction (XRD) analysis suggest that graphite fluorides, (CF)n and (C2F)n are formed via fluorine-intercalated phase with planar graphene layers.  相似文献   

18.
An inductively coupled plasma mass spectrometer (ICP-MS) was used as an ion chromatographic (IC) detector for the speciation analysis of arsenic and selenium. The arsenic and selenium species studied included arsenite [As(III)], arsenate [As(V)], monomethylarsonic acid (MMA), dimethylarsinic acid (DMA), arsenobetaine (AsB), selenite [Se(IV)] and selenate [Se(VI)]. Gradient elution using (NH4)2CO3 and methanol at pH 9 allowed the chromatographic separation of all species in less than 12 min. Effluents from the IC column were delivered to the nebulization system of ICP-DRC-MS for the determination of arsenic and selenium. The potentially interfering 38Ar40Ar+ and 40Ar40Ar+ at the selenium masses m/z 78 and 80 were reduced in intensity by approximately 3 orders of magnitude by using 0.6 mL min−1 CH4 as reactive cell gas in the DRC while an Rpq value of 0.3 was used. Meanwhile, arsenic was determined as the adduct ion 75As12CHH+ at m/z 89, which is more sensitive than 75As. The limits of detection for arsenic and selenium were in the range of 0.002–0.01 ng mL−1 and 0.01–0.02 ng mL−1, respectively, based on peak height. The relative standard deviation of the peak areas for five injections of 5 ng mL−1 As and Se mixture was in the range of 2–4%. The concentrations of arsenic and selenium species have been determined in urine samples collected locally. The major As and Se species in urines were AsB, DMA and probably selenosugar at concentration of 20–40, 15–19 and 17–31 ng mL−1, respectively. The recoveries were in the range of 94–105% for all the determinations. This method has also been applied to determine various arsenic compounds in two fish samples. In this study, a simple and rapid microwave-assisted extraction method was used for the extraction of arsenic compounds from fish. The arsenic species were quantitatively leached with an 80% v/v methanol solution in a focused microwave field during a period of 5 min.  相似文献   

19.
A flow-injection electrochemical immunoassay system based on a disposable immunosensor for the determination of interleukin-6 (IL-6) was proposed. The immunosensor was prepared by entrapping horseradish peroxidase (HRP)-labeled IL-6 antibody into gold nanoparticles-modified composite membrane at a screen-printed graphite electrode. With a non-competitive immunoassay format, the immunosensor was inserted in the flow system with an injection of sample, and the injected sample containing IL-6 antigen was produced transparent immunoaffinity reaction with the immobilized HRP-labeled IL-6 antibody. The formed antigen–antibody complex inhibited partly the active center of HRP, and decreased the immobilized HRP to H2O2 reduction. The performance and factors influencing the performance of the immunosensor were investigated. Under optimal conditions, the current change obtained from the labeled HRP relative to thionine–H2O2 system was proportional to the IL-6 concentration in the range of 5–100 ng L−1 with a detection limit of 1.0 ng L−1 (at 3δ). The flow-injection immunoassay system could automatically control the incubation, washing and measurement steps with acceptable reproducibility and good stability. Moreover, the proposed immunosensors were used to analyze IL-6 in human serum specimens. Analytical results of clinical samples show the developed immunoassay has a promising alternative approach for detecting IL-6 in the clinical diagnosis.  相似文献   

20.
A sample solution was passed at 20 ml min−1 through a column (150×4 mm2) of Amberlite IRA-410Stron anion-exchange resin for 60 s. After washing, a solution of 0.1% sodium borohydride was passed through the column for 60 s at 5.1 ml min−1. Following a second wash, a solution of 8 mol l−1 hydrochloric acid was passed at 5.1 ml min−1 for 45 s. The hydrogen selenide was stripped from the eluent solution by the addition of an argon flow at 150 ml min−1 and the bulk phases were separated by a glass gas–liquid separator containing glass beads. The gas stream was dried by passing through a Nafion® dryer and fed, via a quartz capillary tube, into the dosing hole of a transversely heated graphite cuvette containing an integrated L’vov platform which had been pretreated with 120 μg of iridium as trapping agent. The furnace was held at a temperature of 250°C during this trapping stage and then stepped to 2000°C for atomization. The calibration was performed with aqueous standards solution of selenium (selenite, SeO32−) with quantification by peak area. A number of experimental parameters, including reagent flow rates and composition., nature of the gas–liquid separator, nature of the anion-exchange resin, column dimensions, argon flow rate and sample pH, were optimized. The effects of a number of possible interferents, both anionic and cationic were studies for a solution of 500 ng 1−1 of selenium. The most severe depressions were caused by iron (III) and mercury (II) for which concentrations of 20 and 10 mg  1−1 caused a 5% depression on the selenium signal. For the other cations (cadmium, cobalt, copper, lead,. magnesium, and nickel) concentrations of 50–70 mg 1−1 could be tolerated. Arsenate interfered at a concentration of 3 mg−1, whereas concentrations of chloride, bromide, iodide, perchlorate, and sulfate of 500–900 mg l−1 could be tolerated. A linear response was obtained between the detection limit of 4 ng 1−1, with a characteristic mass of 130 pg. The RSDs for solutions containing 100 and 200 ng 1−1 selenium were 2.3% and 1.5%, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号