首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Peanut is the food group mostly associated with severe and fatal allergic reactions. In the United States, more than 90% of peanut-allergic individuals' serum IgE recognized peanut proteins Ara h 1 and Ara h 2, thus establishing these proteins as major peanut allergens. The amount of Ara h 1 and Ara h 2 in 3 varieties of peanut cultivars that are commonly processed in the industrialized countries was determined to be 12-16 and 6-9%, respectively. Current commercial peanut test kits use polyclonal peanut-specific antibodies to detect soluble or buffer extractable peanut proteins. Because the 2 major peanut allergens Ara h 1 and Ara h 2 are isolated from soluble peanut proteins, it is generally assumed that these commercial kits can detect peanut allergens, although none of these kits claims to detect peanut allergen. This study showed for the first time that the peanut test kits could, in fact, detect major peanut allergens Ara h 1 and Ara h 2 in both native or heat-denatured structures; therefore, these kits qualified to be classified as peanut allergen enzyme-linked immunosorbent assays.  相似文献   

2.
A competitive lateral flow assay for detecting the major peanut allergen, Ara h1, has been developed. The detector reagents are Ara h1-tagged liposomes, and the capture reagents are anti-Ara h1 polyclonal antibodies. Two types of rabbit polyclonal antibodies were raised either against the entire Ara h1 molecules (anti-Ara h1 Ab) or against an immunodominant epitope on Ara h1 (anti-peptide Ab). All of them reacted specifically with Ara h1 in Western Blot against crude peanut proteins. Moreover, the anti-Ara h1 Ab was chosen for this assay development because of its highest immunoactivity to Ara h1-tagged liposomes in the lateral flow assay. The calculated limit of detection (LOD) of this assay is 0.45 g mL–1 of Ara h1 with a dynamic range between 0.1 and 10 g mL–1 of Ara h1 in buffer. Additionally, the visually determined detection range is from 1 to 10 g mL–1 of Ara h1 in buffer. Results using this assay can be obtained within 30 min without the need of sophisticated equipment or techniques; therefore, this lateral flow assay has the potential to be a cost-effective, fast, simple, and sensitive method for on-site screening of peanut allergens.  相似文献   

3.
A highly sensitive disposable amperometric immunosensor based on the use of magnetic beads (MBs) is described for determination of Ara h 1, the major peanut allergen, in only 2 h. The approach uses a sandwich configuration involving selective capture and biotinylated detector antibodies and carboxylic acid-modified MBs (HOOC-MBs). The MBs bearing the immunoconjugates are captured by a magnet placed under the surface of a disposable screen-printed carbon electrode (SPCE) and the affinity reactions are monitored amperometrically at −0.20 V (vs a Ag pseudo-reference electrode) in the presence of hydroquinone (HQ) as electron transfer mediator and upon addition of H2O2 as the enzyme substrate. The developed immunosensor exhibits a wide range of linearity between 20.8 and 1000.0 ng mL−1 Ara h 1, a detection limit of 6.3 ng mL−1, a great selectivity, a good reproducibility with a RSD of 6.3% for six different immunosensors and a useful lifetime of 25 days. The usefulness of the immunosensor was demonstrated by determining Ara h 1 in different matrices (food extracts and saliva). The results correlated properly with those provided by a commercial ELISA method offering a reliable and promising analytical screening tool in the development of user-friendly devices for on-site determination of Ara h 1.  相似文献   

4.
Protein separation can be achieved with different modes of capillary electrophoresis, such as with capillary gel electroporesis (CGE) or with capillary zone electrophoresis (CZE). CZE protein mapping of peanut extract was approached in four different ways, combining neutral-coated or multilayer-coated capillaries with pHs well over or under the isoelectric point range of the proteins of interest. At acidic pHs, the mobility ranges of the major peanut allergens Ara h1, Ara h2, Ara h3, and Ara h6 were identified. Although the pH is a major factor in CZE separation, buffers with different compositions but with the same pH and ionic strength showed significantly different resolutions. Different components of the electrolyte were studied in a multifactorial design of experiment. CE-SDS and CZE proved to be suitable for protein mapping and we were able to distinguish different batches of peanut extract and burned peanut extract.  相似文献   

5.
Complex matrices commonly affect the sensitivity and selectivity of liquid chromatography-mass spectrometry (LC-MS) analysis. Thus, selective sample enrichment strategies are useful particularly to analyze organic biomarkers present in low abundance in samples. A selective immunomagnetic extraction procedure to isolate trace peanut allergen protein Ara h3/4 from breakfast cereals combined with microwave-assisted tryptic digestion and liquid chromatography-electrospray ion-trap tandem mass spectrometry (LC-ESI-IT-MS/MS) measurement was developed. Using protein A-coated magnetic bead (MB) support, anti-Ara h3/4 monoclonal antibodies (Abs) were used as selective capture molecules. The results obtained by LC-ESI-IT-MS/MS in terms of limit of detection (3mg peanuts/kg matrix) and a significantly reduced matrix effect demonstrated that the Ab-coated magnetic bead was very effective to selectively trap Ara h3/4 protein in breakfast cereals. The magnetic bead-based sample treatment followed by LC-IT-MS/MS method here developed can be proposed as very rapid and powerful confirmatory analytical method to verify the reliability of enzyme-linked immunosorbent assay (ELISA) screening methods, since the magnetic bead-LC-IT-MS/MS method combines good sensitivity to the identification capabilities of mass spectrometry.  相似文献   

6.
Proteins of the 2S albumin family, such as Ara h2 and Ara h6, are most frequently involved in peanut allergy. We have developed a reverse enzyme allergo-sorbent test (EAST) in which total serum IgE antibodies are first captured by immobilised anti-human IgE monoclonal antibodies, and then the binding of the anti-Ara h2 and anti-Ara h6 specific IgE to the corresponding labelled allergens is measured. This reverse immunoassay was used either as a direct EAST or as an EAST inhibition assay to study the interactions of whole peanut protein extract and purified Ara h2 and Ara h6 with IgE antibodies from peanut-allergic patients. Finally, we identified some IgE-binding epitopes on Ara h6 using a format of EAST in which the protein is immobilised in a particular, well defined, manner through interactions with specific monoclonal antibodies (mAbs) coated on the micro-plates. The fine specificity of those mAbs has been characterised at the epitope level, and their binding to the allergen thus masks a known particular epitope and makes it unavailable for recognition by IgE antibodies. The reverse EAST increased the ratio specific signal/background. It avoids interferences with competitors such as anti-peanut protein IgG antibodies and allows the study of the specificity and/or affinity of the interactions between IgE antibodies and Ara h2 or Ara h6 with a higher sensitivity and accuracy than the conventional EAST. The EAST results obtained when the allergens are presented by specific mAbs suggest that the homologous molecular domain(s) in peanut 2S albumins encompass major IgE epitope(s) and are strongly involved in peanut allergenicity.  相似文献   

7.
This paper is the first report of a fiber optic SPR biosensor with nanobead signal enhancement. We evaluated the system with a bioassay for the fast and accurate detection of peanut allergens in complex food matrices. Three approaches of an immunoassay to detect Ara h1 peanut allergens in chocolate candy bars were compared; a label-free assay, a secondary antibody sandwich assay and a nanobead enhanced assay. Although label-free detection is the most convenient, our results illustrate that functionalized nanobeads can offer a refined solution to improve the fiber SPR detection limit. By applying magnetite nanoparticles as a secondary label, the detection limit of the SPR bioassay for Ara h1 was improved by two orders of magnitude from 9 to 0.09 μg/mL. The super paramagnetic character of the nanoparticles ensured easy handling. The SPR fibers could be regenerated easily and one fiber could be reused for up to 35 times without loss of sensitivity. The results were benchmarked against a commercially available polyclonal ELISA kit. An excellent correlation was found between the Ara h1 concentrations obtained with the ELISA and the concentrations measured with the SPR fiber assay. In addition, with the SPR fiber we could measure the samples twice as fast as compared to the fastest ELISA protocol. Since the dipstick fiber has no need for microchannels that can become clogged, time consuming rinsing step could be avoided. The linear dynamic range of the presented sensor was between 0.1 and 2 μg/mL, which is considerably larger than the ELISA benchmark.  相似文献   

8.
A liquid chromatography–electrospray-tandem mass spectrometry (LC–ESI-MS–MS) method based on the detection of biomarker peptides from allergenic proteins was devised for confirming and quantifying peanut allergens in foods. Peptides obtained from tryptic digestion of Ara h 2 and Ara h 3/4 proteins were identified and characterized by LC–MS and LC–MS–MS with a quadrupole-time of flight mass analyzer. Four peptides were chosen and investigated as biomarkers taking into account their selectivity, the absence of missed cleavages, the uniform distribution in the Ara h 2 and Ara h 3/4 protein isoforms together with their spectral features under ESI-MS–MS conditions, and good repeatability of LC retention time. Because of the different expression levels, the selection of two different allergenic proteins was proved to be useful in the identification and univocal confirmation of the presence of peanuts in foodstuffs. Using rice crispy and chocolate-based snacks as model food matrix, an LC–MS–MS method with triple quadrupole mass analyzer allowed good detection limits to be obtained for Ara h2 (5 μg protein g−1 matrix) and Ara h3/4 (1 μg protein g−1 matrix). Linearity of the method was established in the 10–200 μg g−1 range of peanut proteins in the food matrix investigated. Method selectivity was demonstrated by analyzing tree nuts (almonds, pecan nuts, hazelnuts, walnuts) and food ingredients such as milk, soy beans, chocolate, cornflakes, and rice crispy. Figure ESI-QTOF-MS mass spectrum of Ara h3/4 triptig digest  相似文献   

9.
A comparison of two methods for the identification and determination of peanut allergens based on europium (Eu)-tagged inductively coupled plasma mass spectrometry (ICP-MS) immunoassay and on liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) with a triple quadrupole mass analyzer was carried out on a complex food matrix like a chocolate rice crispy-based snack. The LC/MS/MS method was based on the determination of four different peptide biomarkers selective for the Ara h2 and Ara h3/4 peanut proteins. The performance of this method was compared with that of a non-competitive sandwich enzyme-linked immunosorbent assay (ELISA) method with ICP-MS detection of the metal used to tag the antibody for the quantitative peanut protein analysis in food. The limit of detection (LOD) and quantitation of the ICP-MS immunoassay were 2.2 and 5 microg peanuts g(-1) matrix, respectively, the recovery ranged from 86 +/- 18% to 110 +/- 4% and linearity was proved in the 5-50 microg g(-1) range. The LC/MS/MS method allowed us to obtain LODs of 1 and 5 microg protein g(-1) matrix for Ara h3/4 and Ara h2, respectively, thus obtaining significantly higher values with respect to the ELISA ICP-MS method, taking into account the different expression for concentrations. Linearity was established in the 10-200 microg g(-1) range of peanut proteins in the food matrix investigated and good precision (RSD <10%) was demonstrated. Both the two approaches, used for screening or confirmative purposes, showed the power of mass spectrometry when used as a very selective detector in difficult matrices even if some limitations still exist, i.e. matrix suppression in the LC/ESI-MS/MS procedure and the change of the Ag/Ab binding with matrix in the ICP-MS method.  相似文献   

10.
Peanut allergic reactions can result from the ingestion of even very small quantities of peanut and represent a severe threat to the health of sensitised individuals. The detection of peanut traces in food products is therefore of prime importance. Peanut traces which can be (unintentionally) present in food products have usually undergone one or more processing steps like roasting and baking. Therefore, methods designed to detect such traces have to be capable of detecting heat-treated peanuts. Commonly used methodologies designed to detect peanut traces in food products are enzyme-linked immunosorbent assays (ELISAs) that detect peanut-specific proteins, and polymerase-chain-reaction (PCR)-based methods targeting peanut-specific DNA. A comparative analysis of such methods was performed and the impact of heat treatment on peanut kernels as well as the impact on a peanut-containing food matrix are investigated. Our results show that heat treatments have a detrimental effect on the detection of peanut with either type of method and that both types of methods are affected in a similar manner.  相似文献   

11.
以花生种子总蛋白及其主要致敏糖蛋白Ara h1为研究对象,采用"一釜法"对蛋白上的糖链进行释放并同时进行衍生化标记,通过C18固相萃取柱纯化,以电喷雾质谱(ESI-MS)、多级串联质谱(MSn)和亲水性液相色谱-质谱联用(HILIC-MS)进行结构解析和定量分析.结果表明,蛋白Ara h1共有10条N-糖链,其中7条为高甘露糖型,2条为木糖修饰,另外1条为与过敏原相关的核心α1,3-Fuc修饰N-糖链,其含量约占总糖链的12.45%.  相似文献   

12.
The detection of food allergens has been a challenge because of the increasing need to ensure the absence of undeclared allergens in foods. The current trend in the detection of some food allergens, like peanuts, is based on the detection of multiple allergenic and nonallergenic proteins, and this is the approach that kit manufacturers have adopted. Because commercial kits differ in their ability to detect allergens, regulatory agencies, the food industry, and kit manufacturers are working together to standardize the detection methods. Three kits for the detection of peanuts have been evaluated for performance by the AOAC Research Institute. For this evaluation, a peanut butter suspension was used as a reference material. Several kit components contribute to between-kit analytical variation, even when the same sample is used. One component of commercial kits, which may be contributing to this variability, is the sample extraction buffer. In this study, differences in extractability of 3 allergenic foods were evaluated by using 4 different extraction buffers. The conclusion is that optimum allergen extractability was buffer-dependent, and no single buffer is appropriate for use as a universal extraction solution for all allergenic foods. Therefore, a thorough evaluation of sample preparation buffers needs to be performed for every individual allergenic food. In light of the results obtained, the current approach used for detection of peanut allergens based on the detection of multiple allergenic and nonallergenic proteins is being analyzed.  相似文献   

13.
An innovative enzyme-linked immunosorbent assay (ELISA) format based on antibody-coated magnetic micro-particles (MPs) for the sensitive detection of Ara h3/4 allergen in food is described. The immunosupport is suspended in the incubation solutions and the MPs with the captured allergen can be easily harvested on a magnet, separated from the solutions, and washed using an easy-to-use, fast and selective approach that allows its detection and quantification. Two differently coated MPs, ProteinA-Pn-b and MP-NH2-PAMAM G 1.5 -Pn-b immunosupports, were tested. The functionalization of the MPs with PAMAM-sodium carboxylate dendrimers elicits a major stability on the immunoglobulin activity resulting in a threefold enhancement of the analytical sensitivity for the assay with respect to a ProteinA immobilization. Validation was carried out on two different matrices: corn flakes and biscuits. In the case of MP-NH2-PAMAM G 1.5 -Pn-b immunosupport, limit of detection was found to be 0.2 mg peanuts/kg matrix in both matrices; the linear response range was demonstrated from 2.5 to 15 mg peanuts/kg matrix by performing statistical tests (homoscedasticity and Mandel fitting tests). Good accuracy and recovery (>80 ± 2%) were obtained. Different food samples were tested and the results were compared with those obtained with a commercially available ELISA kit. The results obtained in this work demonstrated the applicability of the immunomagnetic ELISA methods on real samples and the possibility to perform the assay with significantly reduced reagent and sample consumption.  相似文献   

14.
Results are reported for an interlaboratory validation study of 2 commercially available Iateral flow devices (dipstick tests) designed to detect peanut residues in food matrixes. The test samples used in this study were cookies containing peanuts at 7 different concentrations in the range of 0-30 mg peanuts/kg food matrix. The test samples with sufficient and proven homogeneity were prepared in our laboratory. The analyses of the samples (5 times per level by each laboratory) were performed by 18 laboratories worldwide which submitted a total of 1260 analytical results. One laboratory was found to be an outlier for one of the test kits. In general, both test kits performed well. However, some false-negative results were reported for all matrixes containing < 21 mg peanuts/kg cookie. It must be stressed that the test kits were challenged beyond their cut-off limits (> or = 5 mg/kg, depending on the food matrix). One test kit showed fewer false-negative results, but it led to some false-positive results for the blank materials. The sensitivity of the dipstick tests approaches that achieved with enzyme-linked immunosorbent assays.  相似文献   

15.
A label-free nanoparticle array platform has been used to detect total peanut allergen-specific binding from whole serum of patients suffering from peanut allergy. The serum from 10 patients was screened against a four-allergen panel of cat and dog dander, dust mite and peanut allergen protein Ara h1. The IgE and IgG contributions to the total specific-binding protein load to Ara h1 were identified using two secondary IgG- and IgE-specific antibodies and were found to contribute less than 50?% of the total specific protein load. The total mass of IgE, IgE and the unresolved specific-binding protein ΔsBP for Ara h1 provides a new serum profile for high-RAST-grade patients 5 and 6 with the IgG/IgE ratio of 4?±?2 and ΔsBP/IgE ratio of 17?±?11, neither of which is protective for the small patient cohort.
Figure
Binding of the specefic IgE/IgG and unresolved material X to the sensor surface functionalized with allergen  相似文献   

16.
Peanuts contain proteins that can cause severe allergic reactions in some sensitized individuals. Studies were conducted to determine the percentage of recovery by an enzyme-linked immunosorbent assay (ELISA) method in the analysis for peanuts in energy bars and milk chocolate and to determine the sampling, subsampling, and analytical variances associated with testing energy bars and milk chocolate for peanuts. Food products containing chocolate were selected because their composition makes sample preparation for subsampling difficult. Peanut-contaminated energy bars, noncontaminated energy bars, incurred milk chocolate containing known levels of peanuts, and peanut-free milk chocolate were used. A commercially available ELISA kit was used for analysis. The sampling, sample preparation, and analytical variances associated with each step of the test procedure to measure peanut protein were determined for energy bars. The sample preparation and analytical variances were determined for milk chocolate. Variances were found to be functions of peanut concentration. Sampling and subsampling variability associated with energy bars accounted for 96.6% of the total testing variability. Subsampling variability associated with powdered milk chocolate accounted for >60% of the total testing variability. The variability among peanut test results can be reduced by increasing sample size, subsample size, and number of analyses. For energy bars the effect of increasing sample size from 1 to 4 bars, subsample size from 5 to 20 g, and number of aliquots quantified from 1 to 2 on reducing the sampling, sample preparation, and analytical variance was demonstrated. For powdered milk chocolate, the effects of increasing subsample size from 5 to 20 g and number of aliquots quantified from 1 to 2 on reducing sample preparation and analytical variances were demonstrated. This study serves as a template for application to other foods, and for extrapolation to different sizes of samples and subsamples as well as numbers of analyses.  相似文献   

17.
A review is presented of 3 murine models and a swine neonatal model used to investigate immunotherapeutic options. In Model 1, mutation of linear IgE-binding epitopes of Ara h 1 for the preparation of a hypoallergenic Ara h 1 is discussed with respect to expression in transgenic tobacco plants and correct folding following expression in the pET16b construct. In Model 2, the mutations of Ara h 1 were assessed for use as an immunotherapeutic agent. Although some protective benefit was observed with the modified Ara h 1 protein, animals desensitized with heat-killed E. coil preparations showed increased protection to challenge. In Model 3, soybean homologs to peanut proteins were investigated to determine if soybean immunotherapy can potentially provide benefit to peanut-allergic subjects. Although some protection was provided, additional experimentation with respect to optimal doses for sensitization and challenge will need to be investigated. In Model 4, the neonatal swine model was used to profile different foods (low to moderate to high sensitizing) similar to food allergies in humans. Evidence suggests such feasiblity; however, threshold levels for sensitization and allergic responses will need additional study. In summary, murine and swine animal models are being used to address immunotherapeutic avenues and investigation into the mechanisms of food-allergic sensitization.  相似文献   

18.
Food allergies have become an important health issue especially in industrialized countries. Undeclared allergenic ingredients or the presence of “hidden” allergens because of contamination during the food production process pose great health risks to sensitised individuals. The EU directive for food labelling lists allergenic foods that have to be declared on food products by the manufacturers. The list includes gluten-containing cereals, crustaceans, eggs, fish, peanuts, soybeans, milk, various nuts (e.g. almond, hazelnut, and walnut, etc.), celery, mustard, sesame seeds, lupin, and molluscs. Reliable methods for detection and quantification of food allergens are needed that can be applied in a fast and easy-to-use manner, are portable, and need only limited technical equipment. This review focuses on the latest developments in food allergen analysis with special emphasis on fast immunoanalytical methods such as rapid enzyme-linked immunosorbent assays (ELISA), lateral-flow immunochromatographic assays (LFA) and dipstick tests. Emerging technologies such as immunochemical microarrays and biosensors are also discussed and their application to food allergen analysis is reviewed. Finally, a comprehensive overview of rapid immunochemical test kits that are currently available commercially is given in tabular form.  相似文献   

19.
A novel ICP-MS-based ELISA immunoassay via element-tagged determination was devised for quantitative analysis of hidden allergens in food. The method was able to detect low amounts of peanuts (down to approximately 2 mg peanuts kg−1 cereal-based matrix) by using a europium-tagged antibody. Selectivity was proved by the lack of detectable cross-reaction with a number of protein-rich raw materials.  相似文献   

20.
A new method based on matrix solid-phase dispersion (MSPD) extraction was studied to determine aflatoxin B1, B2, G1 and G2 from peanuts. Optimization of different parameters, such as type of solid supports for matrix dispersion and elution solvents were carried out. The method used 2 g of peanut sample, 2 g of C18 bonded silica as MSPD sorbent and acetonitrile as eluting solvent. Recoveries of each aflatoxin spiked to peanut samples at 2.5 ng/g (5 ng/g for aflatoxin G2) level were between 78 and 86% with relative standard deviations ranging from 4 to 7%. The limits of quantification ranged from 0.125 to 2.5 ng/g for the four studied aflatoxins using liquid chromatography (LC) with fluorescence detection. In addition, LC coupled to mass spectrometry with an electrospray interface was used for confirmation of aflatoxins present in real samples. Eleven peanut samples from different countries were analyzed by the proposed method and by using an enzyme-linked immunosorbent assay (ELISA). ELISA test is a good screening method for investigation of these mycotoxins in peanut samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号