首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Molina M  Silva M 《Electrophoresis》2002,23(7-8):1096-1103
The analytical potential of three fluorescein analogues, fluorescein isothiocyanate isomer I (FITC), 5-(4,6-dichlorotriazinylamino) fluorescein (DTAF) and 5(6)-carboxyfluorescein N-succinimidyl ester (CFSE), as labelling reagents for the ultrasensitive determination of phosphorus-containing amino acid herbicides (glufosinate and glyphosate) and aminomethylphosphonic acid (the major metabolite of glyphosate) by nonionic surfactant micellar electrokinetic chromatography (MEKC) with laser-induced fluorescence (LIF) detection was investigated. Practical aspects related to label chemistry and MEKC separation showed that DTAF is the best choice for the determination of these herbicides; in addition, the most important features of these reagents for the derivatization of amino compounds are discussed. The optimum procedure includes a derivatization step of the herbicides at 40 degrees C with DTAF for 1 h and a 2-fold dilution prior to MEKC analysis, which is conducted within about 10 min using Brij-35 in the running buffer. This nonionic surfactant improves the selectivity and therefore the sensitivity of the method at low analyte concentrations by shifting the interfering peaks of the DTAF excess. The lowest detectable analyte concentration ranged from 0.06 to 0.16 microg/L with a precision of 2.1-3.2%. These results indicate that nonionic surfactant MEKC-LIF is useful as a selective, rapid and sensitive tool for the determination of these herbicides showing a great potential for their analysis in environmental samples without previous enrichment steps. The proposed method surpasses other chromatographic alternatives in terms of limit of detection and sample requirements for the analysis.  相似文献   

2.
曹丽伟  梁丝柳  谭小芳  孟建新 《色谱》2012,30(12):1295-1300
建立了一种快速、有效的毛细管电泳分离-激光诱导荧光检测有机磷除草剂草甘膦、草胺膦和草甘膦的代谢物氨甲基膦酸的方法。将荧光衍生试剂5-(4, 6-二氯三嗪基)氨基荧光素(DTAF)成功用于衍生上述3种化合物。最佳衍生条件: DTAF的浓度为1.0 μmol/L,以50 mmol/L硼酸(pH 9.5)作为缓冲溶液,在30 ℃下反应40 min。以pH 9.5的30 mmol/L硼酸缓冲溶液(含15 mmol/L Brij-35)作为电泳背景电解质,3种衍生物得到基线分离。在优化的条件下,草甘膦、草胺膦、氨甲基膦酸的检出限分别为3.21、6.14和1.99 ng/kg。将该方法应用于环境水样和土壤中除草剂及代谢物的测定,回收率为91.3%~106.0%。该方法准确、灵敏,可满足环境样品中有机磷农药及其代谢物残留的检测要求。  相似文献   

3.
6-Oxy-(N-succinimidyl acetate)-9-(2'-methoxycarbonyl) fluorescein, a new synthesized fluorescent reagent, was established for the first time as a label for the sensitive analysis of catecholamines (CAs) and serotonin (5-HT) by micellar electrokinetic chromatography (MEKC) with laser-induced fluorescence detection. After careful study on the derivatization conditions such as pH value, reagent concentration, temperature and reaction time, the labeling reaction was accomplished as quickly as 7 min with stable yield. The separation parameters for the CAs and 5-HT were also optimized in detail. The derivatives were baseline separated in a running buffer containing 30 mM boric acid and 15 mM sodium dodeculsulfate at pH 9.0. The detection limits ranged from 5 x 10(-10) to 2 x 10(-9) M (signal-to-noise ratio = 3). The rapid and sensitive method was also applied to the determination of the CAs and 5-HT of urine samples.  相似文献   

4.
Fung YS  Lau KM 《Electrophoresis》2003,24(18):3224-3232
To meet the need for a new and validated analytical method for simultaneous determination of inorganic and organic acid anions in beverage drinks, a capillary zone electrophoresis (CZE) procedure had been developed based on a new background electrolyte (BGE) system containing 3 mmol/L 1,3,5-benzenetricarboxylic acid (BTA), 15 mmol/L tris(hydroxymethyl)aminomethane and 1.5 mmol/L tetraethylenepentamine (TEPA) at pH 8.4. Baseline separation of anions commonly found in beverage drinks could be achieved in less than 14 min with indirect UV detection at 240 nm. Comigration problems for hydroxycarboxylic acids could be solved using TEPA as BGE additive. The results indicate excellent repeatability for migration time (RSD, 0.27-0.67%, n = 5) and good precision for both peak height (RSD, 3.2-4.2%, n = 5) and peak area (RSD, 3.1-4.5%, n = 5). Under the optimized conditions and using corrected peak area for quantitation, an excellent linear dynamic range (with correlation coefficient > 0.997 in a concentration range from 0.005 to 2.0 mmol/L) and low detection limit (1-4 micro mol/L) were obtained for all the anions investigated. The applicability and reliability of the CE procedure developed were established by parallel method determination using established ion chromatography procedure for the analysis of inorganic and organic acid anions in orange juice and wine samples. Our CZE procedure provided a sensitive and economic technique for simultaneous determination of inorganic and organic acid anions in orange juice, red and white wine samples.  相似文献   

5.
Serrano JM  Silva M 《Electrophoresis》2007,28(18):3242-3249
This study dealt with the potential of MEKC with LIF detection involving derivatization with sulfoindocyanine succinimidyl ester (Cy5) for the separation and determination of beta-lactam antibiotics (ampicillin, amoxicillin, cephradine, and cephalexin) in environmental water samples. Water samples of 50 mL were enriched by SPE by passage through a weak base-cation Amberlite(R) IRA-93 exchange column. SDS micelles play important roles in the whole analytical process by improving the yield (sensitivity) and the kinetics of the labeling reaction, the elution of the retained antibiotics from the SPE preconcentration system and the electrophoretic resolution of their Cy5-derivatives. The optimum procedure includes a derivatization step of the antibiotics at 25 degrees C for 10 min and direct injection for MEKC analysis, which is conducted within about 15 min using 15 mM SDS in the running buffer (35 mM sodium borate at pH 9.3). LODs from 30 to 45 ng/L and RSDs (within-day precision) from 3.5 to 5.9% were obtained for the antibiotics in water samples with average recoveries ranging from 96.4 to 99.4%. These results indicate that the method proposed is a straightforward and sensitive tool for the determination of these antibiotics in environmental water samples providing similar quantitative results to those using more expensive equipment like LC-electrospray MS/MS.  相似文献   

6.
Molina M  Silva M 《Electrophoresis》2002,23(14):2333-2340
This paper describes a general approach for the in-capillary derivatization of amino compounds and the subsequent sensitive determination of the derivatives by micellar electrokinetic chromatography (MEKC) or capillary zone electrophoresis (CZE) with laser-induced fluorescence (LIF) detection. Amino acids, biogenic amines and amino phosphonic acid-herbicides were chosen as model analytes to evaluate the analytical potential of this approach. Fulfilment of the in-capillary reaction of the analytes using LIF detection hinged on the excellent labeling chemistry of 5-(4,6-dichloro-s-triazin-2-ylamino)fluorescein (DTAF) and the good resolution achieved in the separation of derivatized analytes. Careful optimization of the electrophoretic conditions in the mixing step of this protocol allowed the determination of amino acids, biogenic amines and phosphorus-containing amino acid-herbicides with concentration limits of detection at the nug/L level and relative standard deviations from 3.5 to 5.8%. The whole analysis is carried out within 20 min, resulting in a very simple, fast and practical approach for the fully automated analysis of amino acids and related compounds in low-volume and low-concentration samples.  相似文献   

7.
Orejuela E  Silva M 《Electrophoresis》2005,26(15):2991-2998
A rapid, reliable method has been developed for the multi-residue analysis of aniline metabolites of chlorpropham in potato samples. The method involves the precolumn derivatization of aniline metabolites with 5-(4,6-dichloro-s-triazin-2-ylamino) fluorescein (DTAF) and their subsequent separation and determination by micellar electrokinetic capillary chromatography with laser-induced fluorescence detection (MEKC-LIF). The optimum procedure includes a derivatization step of the aniline metabolites (3-chloroaniline, 3-chloro-4-hydroxyaniline and 3-chloro-4-methoxyaniline) at 40 degrees C for 40 min and a 5-fold dilution prior to MEKC analysis, which is conducted within about 7 min using negative-charged mixed micelles (SDS/Triton X-100) in the running buffer. Under these conditions, the DTAF-anilines were readily detected at 0.3-3.1 microg/L level with a precision of 4.8-6.4%. These results indicate that negative-charged mixed surfactant MEKC-LIF is useful as a selective, rapid, and sensitive tool for the determination of these anilines and surpasses other electrophoretic alternatives based on the use of fluorescein-isothiocyanate (FITC) as label reagent. Finally, the potato matrix showed no significant effects on the derivatization and determination of these analytes, since the analytical figures of merit for the real samples were similar to those obtained in aqueous solutions, and the average recovery at fortification levels of 10-250 microg/kg was over 97%.  相似文献   

8.
王红  张华山 《化学进展》2007,19(5):633-642
作者结合自己的研究工作主要评述了用于分离检测氨基化合物(氨基酸、肽、蛋白质和生物胺等)、巯基化合物(谷胱甘肽、半胱氨酸和高半胱氨酸等)及NO等生物活性物质的荧光标记试剂和荧光分子探针的近期进展和应用。除了传统的的OPA、NDA、DNS、FMOC、FITC、NBD-F、AQC、Cy5等在HPLC和CE分离荧光检测应用新进展,还介绍了许多新的荧光分子探针和标记试剂的性能和应用。它们是N-羟基琥珀酰亚胺活性酯荧光标记试剂,6-氧-(N-琥珀酰亚胺乙酸酯)-9-(2'-甲氧羰基)荧光素(SAMF),1,3,5,7-四甲基-8-苯基-(4'-O-(N-琥珀酰亚胺乙酸酯))-二氟化硼-二吡咯甲烷(TMPAB-Osu,)等和3-碘乙酰胺苯嵌蒽酮荧光探针及MCY5、DSTCY、DCDSTCY和DCTCY等花菁类近红外荧光探针等。  相似文献   

9.
Cao L  Wang H  Zhang H 《Electrophoresis》2005,26(10):1954-1962
The analytical potential of a fluorescein analogue, 6-oxy-(N-succinimidyl acetate)-9-(2'-methoxycarbonyl) fluorescein (SAMF), for the first time synthesized in our laboratory, as a labeling reagent for the labeling and determination of amino compounds by capillary electrophoresis (CE) with laser-induced fluorescence (LIF) detection was investigated. Biogenic monoamines and amino acids were chosen as model analytes to evaluate the analytical possibilities of this approach. The derivatization conditions and separation parameters for the biogenic amines were optimized in detail. The derivatization was performed at 30 degrees C for 6 min in boric acid buffer (pH 8.0). The derivatives were baseline-separated in 15 min with 25 mM boric acid running buffer (pH 9.0), containing 24 mM SDS and 12.5% v/v acetonitrile. The concentration detection limit for biogenic amines reaches 8 x 10(-11) mol.L(-1) (signal-to-noise ratio = 3). The application of CE in the analysis of the SAMF-derivatized amino acids was also exploited. The optimal running buffer for amino acids suggested that weak acidic background electrolyte offered better separation than the basic one. The proposed method was applied to the determination of biogenic amines in three different beer samples with satisfying recoveries varying from 92.8% to 104.8%. Finally, comparison of several fluorescein-based probes for amino compounds was discussed. With good labeling reaction, excellent photostability, pH-independent fluorescence (pH 4-9), and the resultant widely suited running buffer pH, SAMF has a great prospect in the determination of amino compounds in CE.  相似文献   

10.
Serrano JM  Silva M 《Electrophoresis》2006,27(23):4703-4710
This work describes a straightforward and sensitive method for the multi-residue analysis of aminoglycoside antibiotics (kanamycin B, amikacin, neomycin B and paromomycin I) in bovine milk samples. The method involves the pre-capillary derivatization of antibiotics with sulfoindocyanine succinimidyl ester (Cy5) and their separation and determination by MEKC with LIF detection. The optimum procedure includes a derivatization step of the antibiotics at 25 degrees C for 30 min and direct injection for MEKC analysis, which is performed in about 20 min by using borate buffer (35 mM; pH 9.2) with 55 mM SDS as an anionic surfactant and 20% ACN as the organic modifier. Under these conditions, dynamic ranges of 10-500 microg/L and RSDs (within-day precision) from 3.8 to 5.3% were obtained. These results indicate that the proposed MEKC-LIF method is useful as a selective and sensitive tool for the determination of these antibiotics and surpasses other reported electrophoretic alternatives. Finally, the method was successfully applied to bovine milk samples after a simple solid-phase extraction clean-up and preconcentration procedure. The aminoglycosides were readily detected at 0.5-1.5 microg/kg levels with average recoveries ranging from 89.4 to 93.3%.  相似文献   

11.
A procedure using alkaline extraction, solid-phase extraction (SPE) and HPLC is developed to analyze the polar herbicides 2,4-dichlorophenoxyacetic acid (2,4-D) and 4-chloro-2-methylphenoxyacetic acid (MCPA) together with their main metabolites in soils. An ion-pairing HPLC method is used for the determination as it permits the baseline separation of these highly polar herbicides and their main metabolites. The use of a highly cross-linked polystyrene-divinylbenzene sorbent (PS-DVB) gives the best results for the analysis of these compounds. This sorbent allows the direct preconcentration of the analytes at the high pH values obtained after quantitative alkaline extraction of the herbicides from soil samples. Different parameters are evaluated for the SPE preconcentration step. The high polarity of the main analytes of interest (2,4-D and MCPA) makes it necessary to work at low flow rates (< or =0.5 mL min(-1)) in order for these compounds to be retained by the PS-DVB sorbent. A two stage desorption from the SPE sorbent is required to obtain the analytes in solvents that are appropriate for HPLC determination. A first desorption with a 50:50 methanol:water mixture elutes the most polar analytes (2,4-D, MCPA and 2CP). The second elution step with methanol permits the analysis of the other phenol derivatives. The humic and fulvic substances present in the soil are not efficiently retained by PS-DVB sorbents at alkaline pH's and so do not interfere in the analysis. This method has been successfully applied in the analysis of soil samples from a golf course treated with a commercial product containing esters of 2,4-D and MCPA as the active components.  相似文献   

12.
The preparation of highly water‐soluble and strongly fluorescent diketopyrrolopyrrole (DPP) dyes using an unusual taurine‐like sulfonated linker has been achieved. Exchanging a phenyl for a thienyl substituent shifts the emission wavelength to near λ=600 nm. The free carboxylic acid group present in these new derivatives was readily activated and the dyes were subsequently covalently linked to a model protein (bovine serum albumin; BSA). The bioconjugates were characterized by electronic absorption, fluorescence spectroscopy and MALDI‐TOF mass spectrometry, thus enabling precise determination of the labeling density (ratio DPP/BSA about 3 to 8). Outstanding values of fluorescence quantum yield (30 % to 59 %) for these bioconjugates are obtained. The photostability of these DPP dyes is considerably greater than that of fluorescein under the same irradiation conditions. Remarkably low detection limits between 80 and 300 molecules/μm2 were found for the BSA bioconjugates by fluorescence imaging with a epifluorescence microscope.  相似文献   

13.
Summary Sulfonylurea herbicides in soil extracts were concentrated using off-line solid-phase extraction (SPE), and determined by capillary zone electrophoresis (CZE) and UV detection. The method involves extraction of soils with 0.1 M NaHCO3 solution and subsequent preconcentration by using C18 cartridges prior to separation of the pesticide using CZE. The results show that a C18 cartridge is suitable for the purification of sulfonylurea herbicides in soil extracts with the recoveries ranging from 65–103%. The separation conditions affecting the resolution and detection sensitivity was systematically investigated. The sulfonylureas were resolved well using 30 mM sodium acetate (NaAc)/acetic acid (HAc)+10% acetonitrile (ACN) buffer at pH 4.80. The calibration plots for the test solutes in the concentration of 0.2–50 mg L−1 were linear with detection limits in the range of 0.05–0.10 mgL−1. The proposed method has been successfully demonstrated for the determination of sulfonylurea herbicides in soil samples.  相似文献   

14.
A simple capillary zone electrophoresis (CZE) method for the determination of the content of the major sialic acid form N-acetylneuraminic acid (Neu5Ac) in glycoproteins was established. The present method utilizes a simplified hydrolysis-purification procedure consisting of mild acid hydrolysis (25 mM trifluoroacetic acid for 2h at 80 degrees C) to release Neu5Ac and ultrafiltration on Centricon-3 membrane to remove the obtained asialoglycoproteins and other macromolecules present in biologic samples. Derivatization with benzoic anhydride at 80 degrees C for 20 min resulted in complete conversion of Neu5Ac to per-O-benzoylated Neu5Ac. CZE analysis was performed using the operating buffer 25mM phosphate, pH 3.5, containing 50% (v/v) acetonitrile as organic modifier at 30 kV, and detection of the per-O-benzoylated Neu5Ac at 231 nm. The method showed excellent repeatability (RDS<1.98%) and a linearity range from 5 microg/mL to 5mg/mL with a detection limit of 2 microM. Application of the method to microanalysis of human alpha(1)-acid glycoprotein and blood serum samples showed excellent agreement with previously published values, suggesting a high precision for the developed CZE method.  相似文献   

15.
Hirudin, a thrombin inhibitor, is a polypeptide of 65 amino acids. To check purity levels and perform pharmacokinetic studies of recombinant hirudin (r-hirudin), a specific and reproducible analysis method is required. Capillary electrophoresis (CE) is rapidly becoming an important procedure for the analysis of biological molecules. Recently, CE combined with immunoassay has emerged as a new analytical technique. CE-based immunoassay (CEIA) is a sensitive and specific method combining laser-induced fluorescence (LIF) and immunoassay. Therefore, in this study, we specifically investigated fluorescence labeling and determination of r-hirudin by CEIA with a LIF detector using labeled r-hirudin and polyclonal antibody. r-Hirudin was labeled with fluorescein isothiocyanate (FITC). FITC-labeled r-hirudin was purified using high-performance liquid chromatography (HPLC). The method is based on preincubation of r-hirudin and antibody for 20 min, followed by CE analysis using an uncoated capillary. Free and bound r-hirudin were separated within 5 min using CE with high reproducibility. This study demonstrated that the CEIA method could be applied to quantitative analysis of r-hirudin in biological fluids.  相似文献   

16.
A method for sensitive determination of five priority haloacetic acids in drinking water has been developed for the first time based on electromembrane extraction (EME) prior to CZE with capacitively coupled contactless conductivity detection (CZE‐C4D). The target analytes were extracted from 10 mL of the sample solution (donor phase), through the supported liquid membrane (using a polypropylene membrane supporting 1‐octanol), and into 10 µL of 50 mmol/L NaAc solution (acceptor phase). The extracted solution was directly analyzed by CZE‐C4D without derivatization. Several factors that affect separation, detection and extraction efficiency were investigated. Under the optimum conditions, five haloacetic acids (monochloroacetic acid, dichloroacetic acid, trichloroacetic acid, monobromoacetic acid, and dibromoacetic acid) could be well separated from other components coexisting in water samples within 23 min, exhibiting a linear calibration over two orders of magnitude (r?0.9943); the enrichment factors at 430–671 were obtained in a 30 min of extraction, and the limits of detection were in the range of 0.17–0.61 ng/mL. The intraday relative standard deviations for peak areas investigated at 10 ng/mL were between 1.2% and 9.7% for the combined EME‐CZE‐C4D procedure. This approach offers an attractive alternative to the officially proposed method for purified drinking water analysis, which requires derivatization procedure prior to gas chromatography analysis.  相似文献   

17.
合成并表征了系列水溶性五甲川菁染料, 研究了其在不同溶剂中的光谱性能. 结果表明, 染料在水中的最大吸收和荧光光谱在647~665 nm波长范围内, 荧光量子产率达到0.1左右. 考察了N位取代基对染料水溶液光稳定性的影响, 结果表明, 在N原子上引入带有苯环结构和大体积的磺酸基, 可以提高染料的光稳定性. 高效液相色谱(HPLC)分析结果表明, 染料4a的N-羟基琥珀酰亚胺(NHS)活性酯标记牛血清白蛋白(BSA)的检测限为1.2×10-8 mol/L, 与紫外检测相比, 检测灵敏度提高了近2个数量级.  相似文献   

18.
The techniques of the on-line combination of capillary isotachophoresis with zone electrophoresis in two coupled capillaries (ITP-CZE) and a single capillary zone electrophoresis (CZE) were used for the sensitive determination of orotic acid (OA) in human urine. The simple CZE system was successfully applied for fast and reliable analyses of urine of healthy adult volunteers (the detection limit 1.7.10(-6) M OA, the total time of analysis 6 min). However, this method failed in analyses of OA in urine of ill children due to more complex matrix of the samples. Here, the ITP preconcentration and preseparation step coupled on-line with CZE proved to serve well with an electrolyte system developed and optimized for this purpose. The maximum selectivity and resolution of OA from other sample constituents in ITP-CZE was achieved by use of an electrolyte system of very low pH 2.15 both for ITP and CZE stage. The sensitivity of detection and simplicity of OA identification were enhanced by use of an external UV scanning detector. High sensitivity of ITP-CZE combination (limit of detection 3.10(-7) M OA), low sample consumption (1 microliter), good reproducibility of migration times (inter-day RSD < 1.86%) and acceptable reproducibility of the determination of OA in urine samples (average RSD = 7.27%) make this technique suitable for routine determination of trace concentration of OA especially in urine of ill children under various pathological conditions and medication.  相似文献   

19.
A convenient synthetic route towards polymerizable fluorescein, dicholorofluorescein, and eosin dyes is presented. Polymerizability was provided by linking 2‐norbornene carboxylic acid, 11‐bromo‐undecyl ester to the dye's carboxylate functionality. Although the monomers bearing dichlorofluorescein and eosin were obtained in high yield, the related fluorescein bearing monomer could only be obtained in low yield. In the latter case, concurring etherification and esterification led to a product mixture of the desired carboxy modified monomer and a double substituted by‐product. The dye‐monomers were used successfully for the preparation of statistical copolymers with endo,exo‐2,3‐norbornene dicarboxylic acid dimethylester by ROMP. Absorption and luminescence characteristics and, in particular, the acid/base sensitive behavior of the parent dyes were preserved in the monomers and copolymers. The absorption and emission maxima in THF solution and in the solid state were red shifted in comparison to the aqueous samples of the parent dyes. Dye‐copolymers exhibited good film forming properties. Solid state luminescence studies of the copolymers revealed an increasing sensitivity towards NEt3 vapor in the order fluorescein < dichlorofluorescein < eosin bearing copolymer. © 2007 Wiley Periodicals, Inc. J Polym Sci Part A: Polym Chem 45: 1336–1348, 2007  相似文献   

20.
A sensitive and specific analytical procedure for determining arylphenoxypropionic herbicides in soil samples, using Ionspray ionization (ISI) liquid chromatography/mass spectrometry (LC/MS), is presented. Arylphenoxypropionic acids are a new class of herbicides used for selective removal of most grass species from any non-grass crop, commercialized as herbicide esters. Previous studies have shown that the esters undergo fast hydrolysis in the presence of vegetable tissues and soil bacteria, yelding the corresponding free acid. The feasibility of rapidly extracting arylphenoxypropionic herbicides from soil by accelerated solvent extraction (ASE) techniques was evaluated. Four different soil samples were fortified with target compounds at levels of 5 and 20 ng/g by following a procedure able to mimic weathered soils. Herbicides were extracted by a methanol/water (80:20 v/v) solution (0.12 M) of NaCl at 90 degrees C. After clean-up using graphitized carbon black (GCB) as absorbent, the extract was analyzed by HPLC/ISI-MS. The effect of concentration of acid in the mobile phase on the response of ISI-MS was investigated. The effects of varying the orifice plate voltage on the production of diagnostic fragment ions, and on the response of the MS detector, were also investigated. The ISI-MS response was linearly related to the amounts of analytes injected between 1 and 200 ng. The limit of detection (signal-to-noise ratio = 3) of the method for the pesticides in soil samples was estimated to be less than 1 ng/g.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号