共查询到18条相似文献,搜索用时 15 毫秒
1.
Hinrichs K Gensch M Esser N Schade U Rappich J Kröning S Portwich M Volkmer R 《Analytical and bioanalytical chemistry》2007,387(5):1823-1829
The standard methods currently used to read out microarrays are fluorescent and chemiluminesent imaging techniques. These
methods require labeling of a component with a marker and, usually, only the concentration of the marker molecule is detected.
A label-free imaging method that also enables quantitative spectroscopic analysis of the composition and component interaction
would be of great advantage. In this article it is shown for the first time that IR mapping ellipsometry enables label-free
imaging of a biochip before and after incubation with peptide solution. The measurements prove that IR ellipsometry is a sensitive
tool for laterally resolved identification of the different materials and determination of the composition of a biochip. The
lateral resolution required was achieved by using radiation from an infrared synchrotron beamline.
相似文献
2.
<正>A generic method was described to change surface biocompatibihty by introducing reactive functional groups onto surfaces of polymeric substrates and covalently binding them with biomolecules.A block copolymer with protected carboxylic acid functionality,poly(styrene-b-tert-butyl acrylate)(PS-PtBA),was spin coated from solutions in toluene on a bioinert polystyrene(PS) substrate to form a bilayer structure:a surface layer of the poly(tert-butyl acrylate)(PtBA) blocks that order at the air-polymer interface and a bottom layer of the PS blocks that entangle with the PS substrate.The thickness of the PtBA layer and the area density of tert-butyl ester groups of PtBA increased linearly with the concentration of the spin coating solution until a 2 nm saturated monolayer coverage of PtBA was achieved at the concentration of 0.4%W/W.The protected carboxylic acid groups were generated by exposing the tert-butyl ester groups of PtBA to trifluoroacetic acid (TFA) for bioconjugation with FMRF peptides via amide bonds.The yield of the bioconjugation reaction for the saturated surface was calculated to be 37.1%based on X-ray photoelectron spectroscopy(XPS) measurements.The success of each functionalization step was demonstrated and characterized by XPS and contact angle measurements.This polymer functionalization/modification concept can be virtually applied to any polymeric substrate by choosing appropriate functional block copolymers and biomolecules to attain novel biocompatibility. 相似文献
3.
The use of polymers in microchip fabrication affords new opportunities for the development of powerful, miniaturized separation
techniques. One method in particular, the use of phase-changing sacrificial layers, allows for simplified designs and many
additional features to the now standard fabrication of microchips. With the possibility of adding a third dimension to the
design of separation devices, various means of enhancing analysis now become possible. The application of phase-changing sacrificial
layers in microchip analysis systems is discussed, both in terms of current uses and future possibilities.
Figure Phase-changing sacrificial materials enable multilayer microfluidic device layouts 相似文献
4.
Hoegger D Morier P Vollet C Heini D Reymond F Rossier JS 《Analytical and bioanalytical chemistry》2007,387(1):267-275
A micro-analytical system for rapid and quantitative analysis by inhibition immunoassay is presented and applied to the detection of folic acid. Eight polymer microchannels of 65-nL volume each and containing microelectrodes are embedded in a cartridge so that they can be operated simultaneously. All fluidic steps as well as the amperometric detection in the channels are operated by an instrument and software developed in-house. The fluidic steps of the immunoassay occur through hydrodynamic loading of the different solutions through the channels. The speed and duration of the flow and incubation parameters can thus be adapted to the biological and testing requirements. The effectiveness of the system was demonstrated by analysing folic acid concentrations in real infant formula samples within 5 min. In an effort to get a fully monitored assay, each fluidic step is monitored thanks to continuous amperometric detection of oxygen in the microchannel. 相似文献
5.
Lucio Doretti Paola Gattolin Anna Burla Daniela Ferrara Silvano Lora Giancarlo Palma 《Applied biochemistry and biotechnology》1998,74(1):1-12
Bienzymatic sensors for the determination of esters of choline were prepared by covalent co-immobilization of cholinesterases
and choline oxidase on polymer membranes, obtained by radiation-induced copolymerization of 2-hydroxyethyl methacrylate and
glycidyl methacrylate at low temperature. Optimization of the covalent attachment of choline oxidase and acetyl-or butyrylcholinesterase
to copolymer was explored. The enzyme-modified polymers were applied on platinum electrodes to form amperometric sensors,
based on the electrochemical detection of enzymatically developed hydrogen peroxide. Acetyl-, acetylthiobutyryl-, and butyrylthiocholine
contents in standard solutions were measured, and linear calibration curves were determined. Temperature and pH effects on
the electrochemical response are described. 相似文献
6.
Circulating tumor cells are specifically referred as cells that detached from the primary tumor and are present in the bloodstream. They could be isolated from blood and used as representative biomarker for predicting cancer prognoses. Here, we developed a microfluidic chip with multiple curved channels, in which DNA fragments and antibody‐based enrichment are exploited to capture circulating tumor cells in blood sample. By introducing DNA fragments as long tentacles, the active antibody could be extended into the microchannel stereoscopically, which could greatly increase the chances of adhesion in a multidirectional way and improve the capture efficacy. Several pivotal factors for cell capturing were optimized to the best state. Compared to conventional chips for planar capturing, the capture efficiency of MCF‐7 cells was greatly increased from 37.17 to 85.10%. For the detection of MCF‐7‐containing artificial blood sample detection, the capture efficiency of tumor cells was about 74.19 ± 2.13%, which was obviously better than the result of flow cytometry (29.67 ± 4.02%). Captured cells were easily released from the surface of microfluidic chip with high cell viability, which could be investigated for the molecular analysis in the field of tumor diagnosis. 相似文献
7.
Xiaofeng WangUlrich J Krull 《Analytica chimica acta》2002,470(1):57-70
Single-stranded DNA (ssDNA) oligonucleotide in solution, or that is immobilized onto a surface to create a biosensor, can be used as a selective probe to bind to a complementary single-stranded sequence. Fluorescence enhancement of thiazole orange (TO) occurs when the dye intercalates into double-stranded DNA (dsDNA). TO dye has been covalently attached to probe oligonucleotides (homopolymer and mixed base 10mer and 20mer) through the 5′ terminal phosphate group using polyethylene glycol linker. The tethered TO dye was able to intercalate when dsDNA formed in solution, and also at fused silica surfaces using immobilized ssDNA. The results indicated the potential for development of a self-contained biosensor where the fluorescent label was available as part of the immobilized oligonucleotide probe chemistry. The approach was shown to be able to operate in a reversible manner for multiple cycles of detection of targeted DNA sequences. 相似文献
8.
Surface plasmon resonance (SPR) is a powerful and versatile spectroscopic method for biomolecular interaction analysis (BIA)
and has been well reviewed in previous years. This updated 2006 review of SPR, SPR spectroscopy, and SPR imaging explores
cutting-edge technology with a focus on material, method, and instrument development. A number of recent SPR developments
and interesting applications for bioanalysis are provided. Three focus topics are discussed in more detail to exemplify recent
progress. They include surface plasmon fluorescence spectroscopy, nanoscale glassification of SPR substrates, and enzymatic
amplification in SPR imaging. Through these examples it is clear to us that the development of SPR-based methods continues
to grow, while the applications continue to diversify. Major trends appear to be present in the development of combined techniques,
use of new materials, and development of new methodologies. Together, these works constitute a major thrust that could eventually
make SPR a common tool for surface interaction analysis and biosensing. The future outlook for SPR and SPR-associated BIA
studies, in our opinion, is very bright.
Surface plasmon resonance (SPR) is a powerful and versatile spectroscopic method for biomolecular interaction analysis (BIA)
and has been well reviewed in previous years. This updated 2006 review of SPR, SPR spectroscopy, and SPR imaging explores
cutting-edge technology with a focus on material, method, and instrument development. A number of recent SPR developments
and interesting applications for bioanalysis are provided. Three focus topics are discussed in more detail to exemplify recent
progress. They include surface plasmon fluorescence spectroscopy, nanoscale glassification of SPR substrates, and enzymatic
amplification in SPR imaging. Through these examples it is clear to us that the development of SPR-based methods continues
to grow, while the applications continue to diversify. Major trends appear to be present in the development of combined techniques,
use of new materials, and development of new methodologies. Together, these works constitute a major thrust that could eventually
make SPR a common tool for surface interaction analysis and biosensing. The future outlook for SPR and SPR-associated BIA
studies, in our opinion, is very bright.
相似文献
9.
10.
A simple and robust static adsorptive (dynamic) coating process using 2% hydroxyethylcellulose was developed for surface modification of poly(methyl methacrylate) (PMMA) microfluidic chips for DNA separations, suitable for usage over extended periods, involving hundreds of runs. The coating medium was also used as a sieving matrix for the DNA separations following the coating process. Four consecutive static treatments, by simply filling the PMMA chip channels with sieving matrix once every day, were required for obtaining a stable coating and optimum performance. The performance of the coated chips at different phases of the coating process was studied by consecutive gel electrophoretic separations with LIF detection using a PhiX-174/HaeIII DNA digest sample. The coated chip, with daily renewal of the sieving matrix, showed high stability in performance during a 25-day period of systematic study, involving more than 100 individual runs. The performance of the coated chip also remained almost the same after 3 months of continuous usage, during which over 200 separations were performed. The average precision of migration time for the 603-bp fragment was 1.31% RSD (n = 6) during the 25-day study, with a separation efficiency of 6.5 x 10(4) plates (effective separation length 5.4 cm). 相似文献
11.
The widespread interest in micro total analysis systems has resulted in efforts to develop devices in cheaper polymer materials such as polydimethylsiloxane (PDMS) as an alternative to expensive glass and silicon devices. We describe the oxidation of the PDMS surface to form ionizable groups using a discharge from a Tesla coil and subsequent chemical modification to augment electroosmotic flow (EOF) within the microfluidic devices. The flow performance of oxidized, amine-modified and unmodified PDMS materials has been determined and directly compared to conventional glass devices. Exact PDMS replicas of glass substrates were prepared using a novel two step micromolding protocol. Chemical force microscopy has been utilized to monitor and measure the efficacy of surface modification yielding information about the acid/base properties of the modified and unmodified surfaces. Results with different substrate materials correlates well with expected flow modifications as a result of surface modification. Oxidized PDMS devices were found to support faster EOF (twice that of native PDMS) similar to glass while those derivatized with 3-aminopropyl triethoxysilane (APTES) showed slower flow rates compared to native PDMS substrates as a result of masking surface charge. Results demonstrate that the surface of PDMS microdevices can be manipulated to control EOF characteristics using a facile surface derivatization methodology allowing surfaces to be tailored for specific microfluidic applications and characterized with chemical force microscopy. 相似文献
12.
Sara Tombelli Marco Mascini Barbara Scherm Gianni Battacone Quirico Migheli 《Monatshefte für Chemie / Chemical Monthly》2009,140(8):901-907
Abstract In this work, we report on the development of a DNA-based piezoelectric biosensor specific for the detection of an amplicon
of the aflD gene of Aspergillus flavus and A. parasiticus. Expression of this gene is consistently correlated with a strain’s ability to produce aflatoxins that are considered very
potent liver carcinogens in various animal species and humans. The DNA biosensor has been characterized with synthetic oligonucleotides
and amplicons. Moreover, it has been applied to the analysis of real samples consisting of amplicons of DNA extracted from
flours and feed contaminated with A. flavus and A. parasiticus.
Graphical Abstract
相似文献
13.
Advances in molecular techniques for the detection and quantification of genetically modified organisms 总被引:2,自引:1,他引:2
Elenis DS Kalogianni DP Glynou K Ioannou PC Christopoulos TK 《Analytical and bioanalytical chemistry》2008,392(3):347-354
Progress in genetic engineering has led to the introduction of genetically modified organisms (GMOs) whose genomes have been
altered by the integration of a novel sequence conferring a new trait. To allow consumers an informed choice, many countries
require food products to be labeled if the GMO content exceeds a certain threshold. Consequently, the development of analytical
methods for GMO screening and quantification is of great interest. Exponential amplification by the polymerase chain reaction
(PCR) remains a central step in molecular methods of GMO detection and quantification. In order to meet the challenge posed
by the continuously increasing number of GMOs, various multiplex assays have been developed for the simultaneous amplification
and/or detection of several GMOs. Classical agarose gel electrophoresis is being replaced by capillary electrophoresis (CE)
systems, including CE chips, for the rapid and automatable separation of amplified fragments. Microtiter well-based hybridization
assays allow high-throughput analysis of many samples in a single plate. Microarrays have been introduced in GMO screening
as a technique for the simultaneous multianalyte detection of amplified sequences. Various types of biosensors, including
surface plasmon resonance sensors, quartz crystal microbalance piezoelectric sensors, thin-film optical sensors, dry-reagent
dipstick-type sensors and electrochemical sensors were introduced in GMO screening because they offer simplicity and lower
cost. GMO quantification is performed by real-time PCR (rt-QPCR) and competitive PCR. New endogenous reference genes have
been validated. rt-QPCR is the most widely used approach. Multiplexing is another trend in this field. Strategies for high-throughput
multiplex competitive quantitative PCR have been reported. 相似文献
14.
The process of surface functionalization involving silanization, biotinylation and streptavidin bonding as platform for biospecific ligand immobilization was optimized for thin film polyimide spin-coated silicon wafers, of which the polyimide film serves as a wave guiding layer in evanescent wave photonic biosensors. This type of optical sensors make great demands on the materials involved as well as on the layer properties, such as the optical quality, the layer thickness and the surface roughness. In this work we realized the binding of a 3-mercaptopropyl trimethoxysilane on an oxygen plasma activated polyimide surface followed by subsequent derivatization of the reactive thiol groups with maleimide-PEG2-biotin and immobilization of streptavidin. The progress of the functionalization was monitored by using different fluorescence labels for optimization of the chemical derivatization steps. Further, X-ray photoelectron spectroscopy and atomic force microscopy were utilized for the characterization of the modified surface. These established analytical methods allowed to derive information like chemical composition of the surface, surface coverage with immobilized streptavidin, as well as parameters of the surface roughness. The proposed functionalization protocol furnished a surface density of 144 fmol mm−2 streptavidin with good reproducibility (13.9% RSD, n = 10) and without inflicted damage to the surface. This surface modification was applied to polyimide based Mach-Zehnder interferometer sensors to realize a real-time measurement of streptavidin binding validating the functionality of the MZI biosensor. Subsequently, this streptavidin surface was employed to immobilize biotinylated single-stranded DNA and utilized for monitoring of selective DNA hybridization. These proved the usability of polyimide based evanescent photonic devices for biosensing application. 相似文献
15.
Top layers of γ-Al2O3 composite membranes have been modified by the silane coupling technique using phenyltriethoxysilane for improving the separation factor of CO2 to N2. The separation efficiency of the modified membranes was strongly dependent upon the hydroxylation tendency of the support materials and the amount of the special functional group (i.e. phenyl radical) which was coupled onto a top layer. The separation factor through the TiO2 supported γ-Al2O3 membrane was found to be fairly enhanced by silane coupling, but in case of the -Al2O3 supported membrane was not. The CO2/N2 separation factor through the modified γ-Al2O3/TiO2 composite membrane is 1.7 at 90°C and ΔP = 2 × 105 Pa for the binary mixture containing 50 vol% CO2. The separation factor is proportional to the CO2 concentration in the gas mixture, and the modified membrane is stable up to 100°C. The main mechanism of the CO2 transport through the modified γ-Al2O3 layer is known to be a surface diffusion. 相似文献
16.
《Analytical letters》2012,45(11):1495-1505
In this paper, we present a surface plasmon resonance (SPR)-based sensor for measuring DNA hybridization and DNA/small-molecule interactions. A mixed self-assembled monolayer (SAM) was used to optimize the biosensor sensitivity. It was observed that the mixed SAM formed by mixing 10 mM of 16-mercapto-1-hexadecanoic acid (16-MHA) and 6-mercapto-1-hexanol (6-MCH) at a 1:10 molar ratio showed the best results. Subsequently, avidin was attached to the carboxyl groups on the SAM to serve as a binding element for biotinylated single-stranded (ss)DNA. The ssDNA-coated sensor was first evaluated as a nucleic acid biosensor through a DNA-DNA hybridization assay for synthetic 28-mer ssDNA. A linear calibration curve was observed in the range of 0.25–2.5 µg/mL. Non-complementary DNA induced no significant SPR angle shift, which demonstrated the specificity of the assay. Secondly, the sensor was used to monitor the binding kinetics of DNA/small-molecule interactions in real time. The dissociation constant between immobilized DNA and sanguinarine was determined to be 8.0 × 10?6 M. This complies with most data from the literature. In addition, the sensor could be regenerated with 0.01 M HCl and would be feasible for multiple testing. In conclusion, the experimental approach described in this study allows analysis of molecular interactions between DNA-binding drugs and selected targeted DNA sequences. 相似文献
17.
《印度化学会志》2023,100(7):101022
The present study reports using waste silk fabric functionalized using Polylactic acid (PLA) and Activated charcoal for oil/solvent recovery from simulated seawater (3.5% NaCl-based water). An average of 91% separation was visible in the functionalized waste silk fabric with an efficiency up to 20 cycles towards petroleum oils/solvents from simulated seawater. Further, the functionalized waste fabric showed hydrophobic properties with a water-based contact angle of 105° and oil/solvent absorption towards petroleum oils and organic solvent, with a surface free energy of 52.46 mN m−1. The functionalized waste silk also showed permeation flux of 658, 386, and 993 L m−2 h−1, for Petrol, Diesel, and n-Hexane, respectively. The results show that PLA/Activated-charcoal engineered waste silk can be effectively applied for practical oil/solvent recovery from simulated seawater. Utilizing waste silk fabric further supports in reducing the global carbon footprints as silk does not emit and/-or produce carbon dioxide due to its green origin and generating the circular economy approach. 相似文献
18.
《Arabian Journal of Chemistry》2023,16(3):104521
The continuous development of resistance to antibiotic drugs by microorganisms causes high mortality and morbidity. Pathogens with distinct features and biochemical abilities make them destructive to human health. Therefore, early identification of the pathogen is of substantial importance for quick ailments and healthcare outcomes. Several phenotype methods are used for the identification and resistance determination but most of the conventional procedures are time-consuming, costly, and give qualitative results. Recently, great focus has been made on the utilization of advanced techniques for microbial identification. This review is focused on the research studies performed in the last five years for the identification of microorganisms particularly, bacteria using advanced spectroscopic techniques including mass spectrometry (MS), infrared (IR) spectroscopy, Raman spectroscopy (RS), and nuclear magnetic resonance (NMR) spectroscopy. Among all the techniques, MS techniques, particularly MALDI-TOF/MS have been widely utilized for microbial identification. A total of 44 bacteria i.e., 6 Staphylococcus spp., 3 Enterococcus spp., 6 Bacillus spp., 4 Streptococcus spp., 6 Salmonella spp., and one from each genus including Escherichia, Acinetobacter, Pseudomonas, Proteus, Clostridioides, Candida, Brucella, Burkholderia, Francisella, Yersinia, Moraxella, Vibrio, Shigella, Serratia, Citrobacter, and Haemophilus (spp.) were discussed in the review for their identification using the above-mentioned techniques. Among all the identified microorganisms, 21% of studies have been conducted for the identification of E. coli, 14% for S. aureus followed by 37% for other microorganisms. 相似文献