首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Cannabis is not only a widely used illicit drug but also a substance which can be used in pharmacological therapy because of its analgesic, antiemetic, and antispasmodic properties. A very rapid and sensitive method for determination of ?9-tetrahydrocannabinol (THC), the principal active component of cannabis, and two of its phase I metabolites in plasma has been developed and validated. After solid-phase extraction of plasma (0.2 mL), the clean extracts were analyzed by tandem mass spectrometry after a 5-min liquid chromatographic separation. The linear calibration ranges were from 0.05 to 30 ng?mL?1 for THC and 11-nor-?9-carboxy-tetrahydrocannabinol (THC-COOH) and from 0.2 to 30 ng?mL?1 for ?9-(11-OH)-tetrahydrocannabinol (11-OH-THC). Imprecision and inaccuracy were always below 7 and 12 % (expressed as relative standard deviation and relative error), respectively. The method has been successfully applied to determination of the three analytes in plasma obtained from healthy volunteers after oral administration of 20 mg dronabinol.  相似文献   

2.
Melarsoprol is the only currently available drug for treatment of the late stage of African trypanosomiasis (sleeping sickness). Unfortunately, the arsenic-containing drug causes serious side effects, for which the mechanisms have not been elucidated so far. This investigation describes the study of the melarsoprol biotransformation processes by electrochemical (EC) techniques. Based on EC, potential oxidation reactions of melarsoprol are examined. Moreover, the reactivity of melarsoprol, its metabolite melarsen oxide, and their oxidation products toward the tripeptide glutathione and the proteins hemoglobin and human serum albumin is evaluated. The combination of different analytical techniques allows the identification as well as the quantification of the biotransformation products. The hyphenation of liquid chromatography (LC) and electrospray ionization mass spectrometry (ESI–MS) is applied for identification and structure elucidation, which implies the determination of exact masses and fragmentation patterns. For the selective detection of arsenic containing metabolites, LC coupled to inductively coupled plasma mass spectrometry is utilized. Based on the obtained data, the oxidative biotransformation of melarsoprol can be predicted, revealing novel species which have been suspected, but not been identified up to now. The results of the protein studies prove that melarsen oxide, the active derivative of melarsoprol, strongly binds to human hemoglobin and forms different adducts via the free cysteinyl groups of the hemoglobin α- and β-chain.  相似文献   

3.
4.
Cereals and cereal-based food have often been found to be contaminated with the mycotoxins deoxynivalenol (DON) and zearalenone (ZON), after infection of the grain with the pathogenic fungus Fusarium. Both the pathogen and the infected plants can chemically modify DON and ZON, including acetylation, glucosidation, and sulfation. Analytical strategies for detection and quantification of DON and ZON are well known and established but often fail to recognize the respective metabolites, which are, therefore, also referred to as “masked” mycotoxins. However, several masked forms are also known to be harmful to mammals. Failure to detect these could lead to significant underestimation of the toxic potential of a particular sample. To monitor the levels of DON and ZON metabolites in cereals and cereal-based food, we have developed a LC–MS–MS method capable of simultaneous determination of DON, ZON, and eight of their masked metabolites, namely deoxynivalenol-3-glucoside (D3G), 3-acetyl-deoxynivalenol (3ADON), zearalenone-4-glucoside (Z4G), α-zearalenol (α-ZOL), β-zearalenol (β-ZOL), α-zearalenol-4-glucoside (α-ZG), β-zearalenol-4-glucoside (β-ZG), and zearalenone-4-sulfate (Z4S). The suitability of several cleanup strategies including C18-SPE, primary and secondary amines (PSA), MycoSep push-through columns, and immunoaffinity columns was evaluated. The final method used no sample cleanup and was successfully validated for four cereal-based food matrices, namely cornflour, porridge, beer, and pasta, showing good recoveries and precision for all analytes.  相似文献   

5.
The aim of the present study was to develop a chromatographic method for the analysis of atorvastatin, o- and p-hydroxyatorvastatin (acid and lactone forms) in human plasma after administration of atorvastatin at the lowest registered dose (10 mg) in clinical studies. Sample preparation was performed by solid-phase extraction and was followed by separation of the analytes on an HPLC system with a linear gradient and a mobile phase consisting of acetonitrile, water and formic acid. Detection was achieved by tandem mass spectrometry operated in the electrospray positive ion mode. Validation of the method for the compounds for which reference compounds were available (acid forms of atorvastatin, o- and p-hydroxyatorvastatin) showed linearity within the concentration range (0.2–30 ng/ml for atorvastatin acid and p-hydroxyatorvastatin acid, and 0.5–30 ng/ml for o-hydroxyatorvastatin acid) (r20.99, n=5 for all analytes). Accuracy and precision (evaluated at 0.5, 3 and 30 ng/ml for atorvastatin, p-hydroxyatorvastatin and 1, 3 and 30 ng/ml for o-hydroxyatorvastatin) were both satisfactory. The detection limit was 0.06 ng/ml for atorvastatin and p-hydroxyatorvastatin, and 0.15 ng/ml for o-hydroxyatorvastatin. The method has been successfully applied in a clinical study where atorvastatin, o- and p-hydroxyatorvastatin (both acid and lactone forms) could be detected in a 24-h sampling interval after administration of the lowest registered dose of atorvastatin (10 mg) for one week.  相似文献   

6.
Arafat  Tawfiq  Arafat  Basil  Abu Awwad  Ahmad  Schmitz  Oliver J. 《Chromatographia》2016,79(11):685-692

A sensitive, high-throughput and economic liquid chromatographic method for determination of fenofibric acid in human plasma was developed and validated by ultraviolet detection and tandem mass spectrometry, then applied in pharmacokinetic study to investigate Lipanthyl™ 200 mg MC bioavailability under food and fasting conditions. Fenofibric acid with 2-chloro fenofibric acid-d6 (internal standard) was extracted from 100 µL of human plasma by acetonitrile in a single extraction step. 25 and 2 µL from supernatant were injected onto ACE column, 50 mm, 5 micron with 4.6 mm inner diameter for LC–UV and 2.1 mm for LC–MS/MS, and both systems were eluted isocratically by water:methanol:formic acid (35:65:0.1, v/v/v), with a constant flow rate of 1 mL min−1. The established calibration curve was linear between 0.05–20 µg mL−1, and the within- and between-day precisions were all below 13 % in both LC–MS/MS and LC–UV systems during validation, and accuracies ranged between 91 and 112 %. Twenty-eight healthy adult subjects participated in this clinical study, and the pharmacokinetic parameters including coefficient of variation were calculated and discussed. A dramatic decrease in C max and AUC0-72 (3.63- and 1.85-fold, respectively) were observed for Lipanthyl™ MC under fasting conditions with more variable inter subject measurements comparing to the fed state.

  相似文献   

7.
Ginseng has been used by the Chinese as a traditional herbal medicine for thousands of years. In view of the growing popularity in the use of ginseng preparations as natural remedies and food supplements worldwide, there is an increasing concern for their abuse in both human and animal sports. Ginsenosides are considered the major constituents of ginseng responsible for its pharmacological properties. In this study, a method was developed for the detection and confirmation of a number of ginsenosides in horse urine. The intact ginsenosides were detected and confirmed at 5–100 ng mL?1 by LC–MS2, and two deglycosylation metabolites, namely protopanaxadiol and protopanaxatriol, could both be detected and confirmed at 2 ng mL?1 by GC–MS2 after trimethylsilylation. The above GC–MS and LC–MS methods were then applied to study the in vitro metabolism of ginsenosides Rg1 and Rb1 and the in vivo urinary metabolites after oral administration of Rg1 to horses. Results obtained reveal the very first evidence for the existence of the metabolites, Rg1 and protopanaxatriol, as glucuronides in urine.  相似文献   

8.
A sensitive and selective liquid chromatographic tandem mass spectrometric (LC–MS–MS) method was developed for simultaneous identification and quantification of tamsulosin and dutasteride in human plasma, which was well applied to clinical study. The method was based on liquid–liquid extraction, followed by an LC procedure with a Gemini C-18, 50 mm × 2.0 mm (3 μm) column and using methanol:ammonium formate (97:3, v/v) as the mobile phase. Protonated ions formed by a turbo ionspray in positive mode were used to detect analytes and internal standard. MS–MS detection was by monitoring the fragmentation of 409.1 → 228.1 (m/z) for tamsulosin, 529.3 → 461.3 (m/z) for dutasteride and 373.2 → 305.3 (m/z) for finasteride (IS) on a triple quadrupole mass spectrometer. The lower limit of quantification for both tamsulosin and dutasteride was 1 ng mL?1. The proposed method enables the unambiguous identification and quantification of tamsulosin and dutasteride for clinical drug monitoring.  相似文献   

9.
In this work, an analytical multiresidue method using liquid chromatography tandem-mass spectrometry (LC–MS–MS) with triple quadrupole in selected reaction monitoring (SRM) mode for the simultaneous determination of 54 pesticides in vegetables (pepper and tomato) and citrus fruits (orange and lemon) has been developed. The procedure involves initial single phase extraction of sample with acetonitrile by agitation, followed by liquid–liquid partition aided by “salting out” process using NaCl. The average recovery by the LC–MS–MS method obtained for these compounds varied from 65.5 to 114.5% with a relative standard deviation between 2.3 and 8.3%. The method presents good linearity over the range assayed 10–500 μg L?1 (except famoxadone 50–1,000 μg L?1) and the detection limits for the pesticides studied varied from 0.03 to 14.9 μg kg?1. The proposed method was used to determine pesticide levels in vegetables and citrus fruit samples from different experimental orchards and greenhouses from the Region of Murcia.  相似文献   

10.
A simple, sensitive, selective and rapid liquid chromatography–tandem mass spectrometry method was developed and validated for the simultaneous separation and quantitation of atenolol and chlorthalidone in human plasma using metoprolol and hydrochlorothiazide as internal standard. Following solid phase extraction, the analytes were separated by an isocratic mobile phase on a reversed-phase C18 column and analyzed by MS in the multiple reaction-monitoring mode (atenolol in positive and chlorthalidone in the negative ion mode). The limit of quantitation for this method was 10 and 15 ng mL?1 and the linear dynamic range was generally 10–2,050 ng mL?1 and 15–3,035 ng mL?1 for atenolol and chlorthalidone, respectively.  相似文献   

11.
A simple and rapid LC–MS–MS assay was developed and validated for the quantitative determination of pitavastatin in human plasma. Sample pretreatment involved simple protein precipitation by addition of acetonitrile. Separation was on an Agilent 1.8 μm Zorbax SB-C18 column (150 mm × 4.6 mm) at 25 °C using isocratic elution with methanol–0.1% formic acid in water (85:15, v/v) at a flow rate of 0.4 mL min?1. Detection was performed using electrospray ionization in positive ion multiple reaction monitoring mode by monitoring the ion transitions m/z 422.0 → 290.1 for pitavastatin, and m/z 330.1 → 192.1 for paroxetine (IS). LC–MS–MS was found to improve the quantitation of pitavastatin in plasma and was successfully applied in pharmacokinetic studies.  相似文献   

12.
A new, rapid, and efficient method, multiple reaction monitoring liquid chromatography–tandem mass spectrometry, has been developed for analysis of nanafrocin in foodstuffs of animal origin. The researchers used a C18 stationary phase coupled with triple-quadrupole tandem mass spectrometry in negative-electrospray mode. The limits of detection (LOD) and quantification (LOQ) were 0.005 and 0.01 mg kg?1, respectively, in the matrixes. Detector response was found to be a linear function of concentration over the range 0.005–0.1 mg kg?1 in each matrix. Mean overall recovery (n = 10) of nanafrocin varied from 71 to 101%. The results show that identification and quantification of nanafrocin residues in foodstuffs of animal origin can be successfully achieved by use of the proposed LC–MS–MS method.  相似文献   

13.
14.
Cannabinoids are pharmacologically active compounds present in cannabis plants, which have become important research topics in the modern toxicological and medical research fields. Not only is cannabis the most used drug globally, but also cannabinoids have a growing use to treat a series of diseases. Therefore, new, fast, and efficient analytical methods for analyzing these substances in different matrices are demanded. This study developed a new packed-in-tube solid-phase microextraction (IT-SPME) method coupled to liquid chromatography with tandem mass spectrometry (LC–MS/MS), for the automated microextraction of seven cannabinoids from human urine. Packed IT-SPME microcolumns were prepared in (508 µm i.d. × 50 mm) stainless-steel hardware; each one required only 12 mg of sorbent phase. Different sorbents were evaluated; fractional factorial design 24−1 and a central composite design were employed for microextraction optimization. Under optimized conditions, the developed method was a fast and straightforward approach. Only 250 µl of urine sample was needed, and no hydrolysis was required. The sample pretreatment included only dilution and centrifugation steps (8 min), whereas the complete IT-SPME–LC–MS/MS method took another 12 min, with a sample throughput of 3 samples h−1. The developed method presented adequate precision, accuracy and linearity; R2 values ranged from 0.990 to 0.997, in the range of 10–1000 ng ml−1. The lower limits of quantification varied from 10 to 25 ng ml−1. Finally, the method was successfully applied to analyze 20 actual urine samples, and the IT-SPME microcolumn was reused over 150 times.  相似文献   

15.
Synthetic cannabinoids have gained popularity due to their easy accessibility and psychoactive effects. Furthermore, they cannot be detected in urine by routine drug monitoring. The wide range of active ingredients in analyzed matrices hinders the development of a standard analytical method for their determination. Moreover, their possible side effects are not well known which increases the danger.  相似文献   

16.
A simple and specific method for the simultaneous determination of eleutherosides B and E in powdered rhizomes of Eleutherococcus senticosus extract and in solid and liquid dietary supplements was developed and validated. E. senticosus extracts, often mixed with other plants or herbal extracts, are widely used in food supplements because of the tonic and adaptogenic activities referred to the eleutherosides B and E. In this study, samples were analyzed by a liquid chromatography-electrospray tandem mass spectrometry (LC–ESI-MS/MS) method operated in single reaction monitoring (SRM). Validation was carried out in terms of limit of detection (LOD), limit of quantitation (LOQ), linearity, precision and trueness. LOD and LOQ values were fixed at 3 μg L?1 and 10 μg L?1, respectively, whereas linearity was established within 10–1,000 μg L?1 range for both compounds. Good precision was obtained for both eleutherosides in terms of intra-day precision (RSD % lower than 4 %) and inter-day precision (RSD % lower than 6 %). Good percentage recoveries were obtained for both eleutherosides (91.5–103.6 %). Finally, the developed method was successfully applied to analyze a number of solid and liquid commercial dietary supplements containing E. senticosus extracts, also mixed with other herbal extracts.  相似文献   

17.
18.
Benzene, toluene, ethylbenzene, and xylene (BTEX) are a group of volatile organic compounds that are ubiquitous in the environment due to numerous anthropogenic sources. Exposure to BTEX poses a health hazard by increasing the risk for damage to multiple organs, neurocognitive impairment and birth defects. Urinary BTEX metabolites are useful biomarkers for the evaluation of BTEX exposure, because of the ease of sampling and their longer physiological half-lives compared with parent compounds. A method that utilizes LC–MS/MS was developed and validated for simultaneously monitoring of 10 urinary BTEX metabolites. During the sample preparation an aliquot of urine was diluted with an equal volume of 1% formic acid; internal standard solution was added, and then the sample was centrifuged and analyzed. The analytes were separated on the Kinetex-F5 column by applying a linear gradient, consisting of 0.1% formic acid and methanol. The method was validated according to the FDA Bioanalytical Method Validation Guidance for Industry. The mean method's accuracies of the spiked matrix were 81–122%; the inter-day precision ranged from 4 to 20%; the limits of quantitation were 0.5–2 μg/L. The method was used for the evaluation of baseline levels of urinary BTEX metabolites in 87 firefighters.  相似文献   

19.
Liquid chromatography–ion trap mass spectrometry was employed to investigate the metabolism of linarin in rats. Identification and structural elucidation of the metabolites were performed by comparing the differences in molecular masses, retention times, and full scan MS n spectra between linarin and its metabolites. Six metabolites (acacetin, apigenin, acacetin glucuronide, apigenin glucuronide, acacetin sulfate, apigenin sulfate) were detected in rat urine after oral administration of linarin at the dose of 50 mg kg?1. Furthermore, a selective and sensitive liquid chromatography–triple quadruple mass spectrometry assay was developed and validated for the simultaneous determination of linarin and acacetin (the major metabolite of linarin) in rat urine. Chromatographic separation was carried out on a C18 column, and mass spectrometric detection was performed using a triple-quadrupole mass spectrometer coupled with an electrospray ionization source in the positive ion mode. Quantitation of linarin and acacetin was performed using selected reaction monitoring of precursor–product ion transitions at m/z 593 → 285 for linarin, 285 → 242 for acacetin, and 303 → 153 for hesperitin (internal standard), respectively. The assay exhibited good linearity (r > 0.9900) for both linarin and acacetin. The intra- and inter-day precisions were <13.4 % and the accuracy was between ?8.1 and 3.1 %. The method was successfully applied to the urinary excretion study of linarin in rats after oral administration of linarin.  相似文献   

20.
Determination of chlormequat in pig serum and sow milk by LC–MS/MS   总被引:1,自引:0,他引:1  
Chlormequat is a plant growth regulator widely used on cereals, and there is general concern that it may impair human fertility. A LC–MS/MS method for the analysis of chlormequat in milk and serum was developed and validated in connection with an investigation on the effect of chlormequat on pig reproduction. Validation of the method was based on recovery tests at three spiking levels, determined as double determinations and repeated at least four times. Samples were extracted with methanol–water–acetic acid, centrifuged, filtrated and determined by LC–MS/MS. The mean recoveries were in the range 80–110%, and the LOD was 0.2 ng/g for serum and 0.3 ng/g for milk. The values for repeatability and reproducibility were within 2/3 of the limits given by the Horwitz equation. Samples of pig serum (59) and sow milk (27) were analyzed using the method. Chlormequat was determined in four milk samples in the range of 0.4 ng/g to 1.2 ng/g and in all serum samples in the range of 0.2 ng/g−4.0 ng/g.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号