1.
We report high resolution spectra for the medium molecular weight proteins myoglobin and cytochrome-c obtained using a custom desorption electrospray ionisation (DESI) source coupled to a Bruker Daltonics 12 T Apex Qe Fourier transform ion cyclotron resonance mass spectrometer (FTICR-MS). The DESI source was designed for accurate alignment and reproduction of critical geometric variables. A two axis motorised stage was included to enable automated rastering of the sample under the DESI plume. Spectra for the intact proteins have been obtained under single-acquisition conditions and a top-down analysis of cytochrome-c was performed using both collision induced dissociation (CID) and electron capture dissociation (ECD) of the isolated [M+15H]15+ charge state. The sequence coverage is comparable to that obtained using electrospray ionisation, demonstrating the utility of top-down protein analysis by DESI FTICR-MS.  相似文献   

2.
Electron capture dissociation of the peptide Substance P is reported for the first time, with an unmodified, commercially available Fourier transform ion cyclotron resonance (FTICR) mass spectrometer. The fragmentation pattern is compared with that obtained with collisionally induced dissociation of the ions in the electrospray ion source, and note that electron capture dissociation gives a more easily interpreted spectrum, showing mainly C-fragments. With the exception of the proline residues, which require cleavage of two chemical bonds, we observe all C-fragmental we find the bias voltage of the electron gun not to be very critical.  相似文献   

3.
Desorption electrospray ionisation (DESI) has been successfully combined with a hybrid quadrupole time-of-flight mass spectrometer to provide mass spectra and product ion mass spectra of active ingredients formulated in pharmaceutical tablets, gels and ointments. Accurate mass data has been obtained from the DESI mass spectra and of the product ion fragments of selected ions, greatly enhancing the selectivity and information content of the experiment. This accurate mass information only takes seconds to acquire since the DESI technique does not require any sample preparation or extraction prior to mass analysis.  相似文献   

4.
The fragmentation of peptides and oligosaccharides in the gas phase was investigated by means of electrospray ionization Fourier transform ion cyclotron resonance (FTICR) mass spectrometry coupled with dissociation by a laser-cleavage infrared multiphoton dissociation (IRMPD) technique. In this technique, an IR free-electron laser is used as a tunable source of IR radiation to cause cleavage of the ionized samples introduced into the FTICR cell. The gas-phase IRMPD spectra of protonated peptides (substance P and angiotensin II) and two sodiated oligosaccharides (sialyl Lewis X and lacto-N-fucopentaose III) were obtained over the IR scan range of 5.7-9.5 microm. In the IRMPD spectra for the peptide, fragment ions are observed as y/b-type fragment ions in the range 5.7-7.5 microm, corresponding to cleavage of the backbone of the parent amino acid sequence, whereas the spectra of the oligosaccharides have major peaks in the range 8.4-9.5 microm, corresponding to photoproducts of the B/Y type.  相似文献   

5.
The rapid desorption electrospray ionisation (DESI) of some small molecules and their fragmentation using a triple-quadrupole and a hybrid quadrupole time-of-flight mass spectrometer (Q-ToF) have been investigated. Various scanning modes have been employed using the triple-quadrupole instrument to elucidate fragmentation pathways for the product ions observed in the collision-induced dissociation (CID) spectra. Together with accurate mass tandem mass spectrometry (MS/MS) measurements performed on the hybrid Q-ToF mass spectrometer, unequivocal product ion identification and fragmentation pathways were determined for deprotonated metoclopramide and protonated aspirin, caffeine and nicotine. Ion structures and fragmentation pathway mechanisms have been proposed and compared with previously published data. The necessity for elevated resolution for the differentiation of isobaric ions are discussed.  相似文献   

6.
The use of a new electrospray qQq Fourier transform ion cyclotron mass spectrometer (qQq-FTICR MS) instrument for biologic applications is described. This qQq-FTICR mass spectrometer was designed for the study of post-translationally modified proteins and for top-down analysis of biologically relevant protein samples. The utility of the instrument for the analysis of phosphorylation, a common and important post-translational modification, was investigated. Phosphorylation was chosen as an example because it is ubiquitous and challenging to analyze. In addition, the use of the instrument for top-down sequencing of proteins was explored since this instrument offers particular advantages to this approach. Top-down sequencing was performed on different proteins, including commercially available proteins and biologically derived samples such as the human E2 ubiquitin conjugating enzyme, UbCH10. A good sequence tag was obtained for the human UbCH10, allowing the unambiguous identification of the protein. The instrument was built with a commercially produced front end: a focusing rf-only quadrupole (Q0), followed by a resolving quadrupole (Q1), and a LINAC quadrupole collision cell (Q2), in combination with an FTICR mass analyzer. It has utility in the analysis of samples found in substoichiometric concentrations, as ions can be isolated in the mass resolving Q1 and accumulated in Q2 before analysis in the ICR cell. The speed and efficacy of the Q2 cooling and fragmentation was demonstrated on an LCMS-compatible time scale, and detection limits for phosphopeptides in the 10 amol/muL range (pM) were demonstrated. The instrument was designed to make several fragmentation methods available, including nozzle-skimmer fragmentation, Q2 collisionally activated dissociation (Q2 CAD), multipole storage assisted dissociation (MSAD), electron capture dissociation (ECD), infrared multiphoton induced dissociation (IRMPD), and sustained off resonance irradiation (SORI) CAD, thus allowing a variety of MS(n) experiments. A particularly useful aspect of the system was the use of Q1 to isolate ions from complex mixtures with narrow windows of isolation less than 1 m/z. These features enable top-down protein analysis experiments as well structural characterization of minor components of complex mixtures.  相似文献   

7.
Many biomarker discovery studies are based on matrix-assisted laser desorption/ionisation (MALDI) peptide profiles. In this study, 96 human serum samples were analysed on a Bruker solariX(TM) MALDI Fourier transform ion cyclotron resonance (FTICR) system equipped with a 15 tesla magnet. Isotopically resolved peptides were observed in ultrahigh resolution FTICR profiles up to m/z 6500 with mass measurement errors (MMEs) of previously identified peptides at a sub-ppm level. For comparison with our previous platform for peptide profile mass analysis (i.e. Ultraflex II) the corresponding time-of-flight (TOF) spectra were obtained with isotopically resolved peptides up to m/z 3500. The FTICR and TOF systems performed rather similar with respect to the repeatability of the signal intensities. However, the mass measurement precision improved at least 10-fold in ultrahigh resolution data and thus simplified spectral alignment necessary for robust and quantitatively precise comparisons of profiles in large-scale clinical studies. From each single MALDI-FTICR spectrum an m/z-list was obtained with sub-ppm precision for all different species, which is beneficial for identification purposes and interlaboratory comparisons. Furthermore, the FTICR system allowed new peptide identifications from collision-induced dissociation (CID) spectra using direct infusion of reversed-phase (RP) C(18)-fractionated serum samples on an electrospray ionisation (ESI) source.  相似文献   

8.
Hormone and veterinary drug screening and forensics can benefit from the recent developments in desorption electrospray ionization (DESI) mass spectrometry (MS). In this work the feasibility of DESI application for the rapid screening of intact esters of anabolic steroids in bovine hair has been studied. Using a linear ion trap both full scan and data-dependent collision induced dissociation MS(n) spectra were acquired in minutes for testosterone cypionate, testosterone decanoate and estradiol benzoate standard solutions deposited on a glass or PTFE surface. However direct analysis of incurred hair failed due to inefficient desorption ionization and the minute quantities of steroid esters present. Therefore a simplified ultrasonic liquid extraction procedure was developed, allowing rapid DESI analysis of a few microliters of the concentrate and a total analysis time of 2-4h per batch instead of 3 days. The potential of this DESI approach is clearly demonstrated by MS(3) data from hair samples incurred with high levels (300-800 μg kg(-1)) of steroid esters, levels which do occur in samples from controlled- and illegally treated animals. For much lower levels state-of-the-art ultra high performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) screening methods remain the method of choice and might benefit from the proposed simplified extraction as well.  相似文献   

9.
The intact yeast alcohol dehydrogenase (ADH) tetramer of 147 kDa was introduced into a FTICR mass spectrometer by native electrospray. Electron capture dissociation of the entire 23+ to 27+ charge state distribution produced the expected charge-reduced ions and, more unexpectedly, 39 c-type peptide fragments that identified N-terminus acetylation and the first 55 amino acids. The results are in accord with the crystal structure of yeast ADH, which shows that the C-terminus is buried at the assembly interface, whereas the N-terminus is exposed, allowing ECD to occur. This remarkable observation shows promise that a top-down approach for intact protein assemblies will be effective for characterizing their components, inferring their interfaces, and obtaining both proteomics and structural biology information in one experiment.  相似文献   

10.
Negative ion desorption electrospray ionization (DESI) was used for the analysis of an ex vivo tissue sample set comprising primary colorectal adenocarcinoma samples and colorectal adenocarcinoma liver metastasis samples. Frozen sections (12 μm thick) were analyzed by means of DESI imaging mass spectrometry (IMS) with spatial resolution of 100 μm using a computer-controlled DESI imaging stage mounted on a high resolution Orbitrap mass spectrometer. DESI-IMS data were found to predominantly feature complex lipids, including phosphatidyl-inositols, phophatidyl-ethanolamines, phosphatidyl-serines, phosphatidyl-ethanolamine plasmalogens, phosphatidic acids, phosphatidyl-glycerols, ceramides, sphingolipids, and sulfatides among others. Molecular constituents were identified based on their exact mass and MS/MS fragmentation spectra. An identified set of molecules was found to be in good agreement with previously reported DESI imaging data. Different histological tissue types were found to yield characteristic mass spectrometric data in each individual section. Histological features were identified by comparison to hematoxylin-eosin stained neighboring sections. Ions specific to certain histological tissue types (connective tissue, smooth muscle, healthy mucosa, healthy liver parenchyma, and adenocarcinoma) were identified by semi-automated screening of data. While each section featured a number of tissue-specific species, no potential global biomarker was found in the full sample set for any of the tissue types. As an alternative approach, data were analyzed by principal component analysis (PCA) and linear discriminant analysis (LDA) which resulted in efficient separation of data points based on their histological types. A pixel-by-pixel tissue identification method was developed, featuring the PCA/LDA analysis of authentic data set, and localization of unknowns in the resulting 60D, histologically assigned LDA space. Novel approach was found to yield results which are in 95% agreement with the results of classical histology. KRAS mutation status was determined for each sample by standard molecular biology methods and a similar PCA/LDA approach was developed to assess the feasibility of the determination of this important parameter using solely DESI imaging data. Results showed that the mutant and wild-type samples fully separated. DESI-MS and molecular biology results were in agreement in 90% of the cases.  相似文献   

11.
We describe a fully automated high performance liquid chromatography 9.4 tesla Fourier transform ion resonance cyclotron (FTICR) mass spectrometer system designed for proteomics research. A synergistic suite of ion introduction and manipulation technologies were developed and integrated as a high-performance front-end to a commercial Bruker Daltonics FTICR instrument. The developments incorporated included a dual-ESI-emitter ion source; a dual-channel electrodynamic ion funnel; tandem quadrupoles for collisional cooling and focusing, ion selection, and ion accumulation, and served to significantly improve the sensitivity, dynamic range, and mass measurement accuracy of the mass spectrometer. In addition, a novel technique for accumulating ions in the ICR cell was developed that improved both resolution and mass measurement accuracy. A new calibration methodology is also described where calibrant ions are introduced and controlled via a separate channel of the dual-channel ion funnel, allowing calibrant species to be introduced to sample spectra on a real-time basis, if needed. We also report on overall instrument automation developments that facilitate high-throughput and unattended operation. These included an automated version of the previously reported very high resolution, high pressure reversed phase gradient capillary liquid chromatography (LC) system as the separations component. A commercial autosampler was integrated to facilitate 24 h/day operation. Unattended operation of the instrument revealed exceptional overall performance: Reproducibility (1-5% deviation in uncorrected elution times), repeatability (<20% deviation in detected abundances for more abundant peptides from the same aliquot analyzed a few weeks apart), and robustness (high-throughput operation for 5 months without significant downtime). When combined with modulated-ion-energy gated trapping, the dynamic calibration of FTICR mass spectra provided decreased mass measurement errors for peptide identifications in conjunction with high resolution capillary LC separations over a dynamic range of peptide peak intensities for each spectrum of 10(3), and >10(5) for peptide abundances in the overall separation.  相似文献   

12.
A new method to analyze free amino acids using desorption electrospray ionization (DESI) has been implemented. The method is based on the neutral loss mode determination of underivatized amino acids using a tandem quadrupole mass spectrometer equipped with an unmodified atmospheric interface. Qualitative and quantitative optimization of DESI parameters, including ESI voltage, solvent flow rate, angle of collection and incidence, gas flow and temperatures, was performed for amino acids detection. The parameters for DESI analysis were evaluated using a mixture of valine, leucine, methionine, phenylalanine and tyrosine standards. A few microliters of this mixture were deposited on a slide, dried and analyzed at a flow rate of 2 microL/min. The optimal ionization response was obtained using laboratory glass slides and an equivalent solution of water/methanol doped with 2% of formic acid. The method specificity was evaluated by comparing product ion spectra and neutral loss analysis of amino acids obtained either by DESI or by electrospray ionization flow injection analysis (ESI-FIA). To evaluate the quantitative response on amino acids analyzed by DESI, calibration curves were performed on amino acid standard solutions spiked with a fixed amount of labelled amino acids. The method was also employed to analyze free amino acids from blood spots, after a rapid solvent extraction without other sample pretreatment, from positive and negative subjects. The method enables one to analyze biological samples and to discriminate healthy subjects from patients affected by inherited metabolic diseases. The intrinsic high-throughput analysis of DESI represents an opportunity, because of its potential application in clinical chemistry, for the expanded screening of some inborn errors of metabolism.  相似文献   

13.
A novel pulse sequence improving the efficiency for electron capture dissociation (ECD) of an unmodified Fourier transform ion cyclotron resonance (FTICR) mass spectrometer by more than an order of magnitude is presented. Commercially available FTICR instruments are usually equipped with a filament-based electron source producing an electron beam that has a rather small cross section. An ideal overlap between the rotating ion cloud and the electron beam appears to be a prerequisite for a high ECD efficiency. A reduced interception of the ion cloud and the electron beam is probably due to the contribution of the magnetron motion to the trajectory of the ions, resulting in a precession about the z-axis of the instrument. By increasing the kinetic energy and therefore increasing the cyclotron radii of the precursor ions by resonant excitation, the overlap of the rotating ion cloud with the electron beam is improved. By use of this protocol the efficiency of electron capture is substantially increased and consequently the acquisition time of ECD spectra is reduced significantly. The capability of resonant excitation of the precursor ions during the irradiation with electrons is demonstrated for standard peptides. This approach is particularly valuable for analysis and characterization of O-glycosylated peptides. In addition to amino acid sequence information, the attachment site of the labile glycan moiety is determined, and also radical-site-induced fragmentations of the glycosidic bonds are observed.  相似文献   

14.
A new hybrid electrospray quadrupole Fourier transform mass spectrometry (FTMS) instrument design is shown and characterized. This instrument involves coupling an electrospray source and mass-resolving quadrupole, ion accumulation, and collision cell linear ion trap system developed by MDS Sciex with a home-built ion guide and ion cyclotron resonance (ICR) cell. The iterative progression of this design is shown. The final design involves a set of hexapole ion guides to transfer the ions from the accumulation/collision trap through the magnetic field gradient and into the cell. These hexapole ion guides are separated by a thin gate valve and two conduction limits to maintain the required <10(-9) mbar vacuum for FTICR. Low-attomole detection limits for a pure peptide are shown, 220 000 resolving power in broadband mode and 820 000 resolving power in narrow-band mode are demonstrated, and mass accuracy in the <2 ppm range is routinely available provided the signal is abundant, cleanly resolved, and internally calibrated. This instrument design provides high experimental flexibility, allowing Q2 CAD, SORI-CAD, IRMPD, and ECD experiments with selected ion accumulation as well as experiments such as nozzle skimmer dissociation. Initial top-down mass spectrometry experiments on a protein is shown using ECD.  相似文献   

15.
A new mode of operation for desorption electrospray ionization (DESI) analysis of liquids or solid residues from evaporated solvents is presented. Unlike traditional DESI, the electrospray is not deflected off of a surface but instead is transmitted through a sampling mesh at a 0° angle between the electrospray tip, sample mesh, and capillary inlet of a mass spectrometer. In this configuration, deposited samples can be analyzed rapidly without rigorous optimization of spray distances or angles and without the preparation time associated with solvent evaporation. The new transmission mode desorption electrospray ionization (TM-DESI) technique is not applicable to bulk materials, but instead is a method designed to simplify the sample preparation process for liquid samples and sample extracts. The technique can reduce analysis time to seconds while consuming only microliters of sample. The results presented summarize the optimization of the technique, highlight key figures of merit for several model compounds, and illustrate potential applications to high throughput screening of liquid mixtures in both extraction solvents and biological matrices.  相似文献   

16.
Desorption electrospray ionization mass spectrometry (DESI-MS) was used as a simple and rapid way to analyze drug tablets and powders without sample preparation. Experiments were performed with a home-made DESI source coupled to a triple-quadrupole linear-ion trap (QqQ(LIT)) mass spectrometer. Twenty-one commercial drugs as well as some illicit Ecstasy tablets and powders were analyzed. MS spectra almost exclusively showed the protonated or deprotonated ion of the drug after directing the pneumatically assisted electrospray onto the tablet's surface. With some tablets, inhomogeneity of the surface resulted in different spectra depending on the spot analyzed, thus showing that DESI could be used for imaging. Directly triggered MS/MS spectra were used for confirmatory analysis, with analysis times often below 10 s per tablet. For illicit Ecstasy tablets, DESI-MS, GC/MS and LC/MS analyses provided similar qualitative results for the main analytes. With MS/MS spectra library comparison or exact mass measurements, this technique could become very powerful for the rapid analysis of unknown tablets and shows the great potential of desorption techniques as an alternative to solution-based analysis.  相似文献   

17.
In this paper a novel workflow-based data acquisition and control system for Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) is presented that facilitates a fast on-the-fly decision-making process for a wide variety of data-dependent experiments. Several new workflow implementations demonstrate the flexibility and benefit of this approach for rapid dynamic experimental design on a chromatographic timescale. The different sequence, evaluation, decision and monitoring modules are described using a selected set of examples. During a tandem liquid chromatography (LC)/FTICR-MS experiment the system is used to dynamically switch between various dissociation techniques such as electron capture dissociation (ECD) and sustained off-resonance irradiation (SORI) depending on the charge state of a tryptic peptide peak. The use of this workflow-based system for imaging FTICR-MS using a desorption electrospray ionization (DESI) source demonstrates the possibility of external control of the workflow by feedback from an imaging sample stage.  相似文献   

18.
High mass-resolving power has been shown to be useful for studying the conformational dynamics of proteins by hydrogen/deuterium (H/D) exchange. A computer algorithm was developed that automatically identifies peptides and their extent of deuterium incorporation from H/D exchange mass spectra of enzymatic digests or fragment ions produced by collisionally induced dissociation (CID) or electron capture dissociation (ECD). The computer algorithm compares measured and calculated isotopic distributions and uses a fast calculation of isotopic distributions using the fast Fourier transform (FFT). The algorithm facilitates rapid and automated analysis of H/D exchange mass spectra suitable for high-throughput approaches to the study of peptide and protein structures. The algorithm also makes the identification independent on comparisons with undeuterated control samples. The applicability of the algorithm was demonstrated on simulated isotopic distributions as well as on experimental data, such as Fourier transform ion cyclotron resonance (FTICR) mass spectra of myoglobin peptic digests, and CID and ECD spectra of substance P.  相似文献   

19.
Desorption electrospray ionization (DESI) mass spectrometry has been implemented on a commercial ion‐trap mass spectrometer and used to optimize mass spectrometric conditions for DNA nucleobases: adenine, cytosine, thymine, and guanine. Experimental parameters including spray voltage, distance between mass spectrometer inlet and the sampled spot, and nebulizing gas inlet pressure were optimized. Cluster ions including some magic number clusters of nucleobases were observed for the first time using DESI mass spectrometry. The formation of the cluster species was found to vary with the nucleobases, acidification of the spray solvent, and the deposited sample amount. All the experimental results can be explained well using a liquid film model based on the two‐step droplet pick‐up mechanism. It is further suggested that solubility of the analytes in the spray solvent is an important factor to consider for their studies by using DESI. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

20.
A commercial air ejector was coupled to an electrospray ionization linear ion trap mass spectrometer (LTQ) to transport remotely generated ions from both electrospray (ESI) and desorption electrospray ionization (DESI) sources. We demonstrate the remote analysis of a series of analyte ions that range from small molecules and polymers to polypeptides using the AE-LTQ interface. The details of the ESI-AE-LTQ and DESI-AE-LTQ experimental configurations are described and preliminary mass spectrometric data are presented.  相似文献   