首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The on-line combination of CZE with capillary ITP (ITP-CZE) was used for the separation and quantification of selected flavonoids and phenolic acids in Hypericum perforatum leaves and flowers collected in six different localities in Slovakia. The leading electrolyte in the ITP preseparation step was 10 mM HCl with Tris as counterion (pH* 7.2). The terminating electrolyte was 50 mM boric acid of pH* 8.2 (adjusted with barium hydroxide). The BGE in the electrophoretic step contained 25 mM beta-hydroxy-4-morpholinopropanesulfonic acid (MOPSO), 50 mM Tris, 65 mM boric acid, pH* 8.3. The content of methanol in all electrolytes was 20% v/v. The total time of the analysis (including the preseparation step) was approximately 35 min. The rectilinear calibration ranges were between 0.125 and 5.0 microg/mL with kaempferol as internal standard. The correlation coefficients ranged between 0.9912 (for quercitrin and chlorogenic acid) and 0.9988 (for isoquercitrin). The RSD values are between 0.86 and 7.78% (n = 6) when determining rutin and quercetin (4 microg/mL). The optimized method was employed for the assay of flavonoids in medicinal plant extract of different collections of Hypericum perforatum haulm. The variability of the content of the active components depending on the place of collection was confirmed.  相似文献   

2.
CE with capacitively coupled contactless detection (C4D) was used to determine 3-methylhistidine (3-MH) and 1-methylhistidine (1-MH). The C4D response to 3-MH was studied in a BGE consisting of 500 mM acetic acid and ammonia at varying concentration and the results were compared with the theory. Complete separation of a model mixture of 3-MH, 1-MH, and histidine (His) was attained in two optimized BGEs, one containing 500 mM HAc, 20 mM NH4OH, and 0.1 % m/v hydroxyethylcellulose (HEC), pH 3.4 (I) and the other consisting of 100 mM morpholinoethanesulfonic acid (MES), 25 mM LiOH, and 0.1 % m/v HEC, pH 5.5 (II). These optimized BGEs were tested in CE/C4D analyses of urine. Promising results were obtained for separation and determination of 3-MH, 1-MH, and His on a silicon microchip, using aluminum strips as the C4D electrodes; the three analytes were baseline-separated within less than 30 s with a separation channel effective length of 38 mm. The LOD were satisfactory and amounted to 26.4 microM for 3-MH and 18.3 microM for 1-MH.  相似文献   

3.
CE with capacitively coupled contactless conductivity detection (C(4)D) was used to determine waste products of the nitrogen metabolism (ammonia and creatinine) and of biogenic inorganic cations in samples of human urine. The CE separation was performed in two BGEs, consisting of 2 M acetic acid + 1.5 mM crown ether 18-crown-6 (BGE I) and 2 M acetic acid + 2% w/v PEG (BGE II). Only BGE II permitted complete separation of all the analytes in a model sample and in real urine samples. The LOD values for the optimized procedure ranged from 0.8 microM for Ca(2+) and Mg(2+) to 2.9 microM for NH(4)(+) (in terms of mass concentration units, from 7 microg/L for Li(+) to 102 microg/L for creatinine). These values are adequate for determination of NH(4)(+), creatinine, Na(+), K(+), Ca(2+) and Mg(2+) in real urine samples.  相似文献   

4.
The analysis is described for separating seven beta-adrenergic blocking agents (atenolol, celiprolol, clorprenaline, fenoterol, metoprolol, propranolol, terbutaline) and clenbuterol (sympathomimetic beta-2 receptor stimulating agonist, decongestant and bronchodilator, illicit anabolic used in athletics) by CE with UV detection. In order to simultaneously separate all analytes, Tris-H3PO4 solution was applied containing titanium dioxide nanoparticles (TiO2 NPs) as BGEs. The effects of important factors, such as concentration of TiO2 NPs, optimum pH, run buffer concentration, and separation voltage, were investigated so as to achieve best CE separation. The eight analytes could be well separated applying a separation voltage of 15 kV in 75 mM Tris-H3PO4 buffer at a pH of 2.40, containing 6.0 x 10(-6) g/mL TiO2 NPs. Under these optimal conditions, the RSDs for peak areas and for migration times were less than 2.7 and 2.3%, respectively. The detection limits were 0.1 microg/mL for celiprolol, 0.1 microg/mL for propranolol, 0.2 microg/mL for fenoterol, 1.0 microg/mL for atenolol, 1.0 microg/mL for clenbuterol, 1.0 microg/mL for clorprenaline, 1.0 microg/mL for metoprolol, and 1.0 microg/mL for terbutaline. The proposed method was successfully applied for the rapid CE determination of the frequently applied antihypertensive beta-blocking compounds atenolol, metoprolol, terbutaline, and propranolol in pharmaceutical tablets.  相似文献   

5.
Capillary zone electrophoresis (CZE) has been applied to qualitative analysis, separation, and physicochemical characterization of synthetic insect oostatic peptides (IOPs) and their derivatives and fragments. Series of homologous IOPs were separated in three acidic background electrolytes (BGEs; pH 2.25, 2.30, 2.40) and an alkaline BGE (pH 8.1). Best separation was achieved in acid BGE composed of 100 mM H3PO4, 50 mM Tris, pH 2.25. The effective electrophoretic mobilities, mu(ep), of all IOPs in four BGEs were determined and several semiempirical models correlating effective mobility with charge-to-size ratio (mu(ep) versus q/Mr k) were tested to describe the migration behavior of IOP in CZE. None of models was found to be unambiguously applicable for the whole set of 20 IOPs differing in size (dipeptide - decapeptide) and charge (-2 to +0.77 elementary charges). However, a high coefficient of correlation, 0.9993, was found for the subset of homologous series of IOPs with decreasing number of proline residues at C-terminus, H-Tyr-Asp-Pro-Ala-Prox-OH, x = 6 - 0, for the dependence of mu(ep) on q/Mr k with k = 0.5 for IOPs as anions in alkaline BGE and with k = 2/3 for IOPs as cations in optimized acidic Tris-phosphate BGE. From these dependences the probable structure of IOPs in solution could be predicted.  相似文献   

6.
The separation and simultaneous determination of caffeine, paracetamol, and acetylsalicylic acid in two analgesic tablet formulations was investigated by capillary electrochromatography (CEC). The effect of mobile phase composition on the separation and peak efficiency of the three analytes was studied and evaluated; in particular, the influence of buffer type, buffer pH, and acetonitrile content of the mobile phase was investigated. The analyses were carried out under optimized separation conditions, using a full-packed silica capillary (75 microm ID; 30.0 cm and 21.5 cm total and effective lengths, respectively) with a 5 microm C8 stationary phase. A mixture of 25 mM ammonium formate at pH 3.0 and acetonitrile (30:70 v/v) was used as the mobile phase. UV detection was at 210 nm. Good linearity was found in the range of 50-200, 20-160, and 4-20 microg/mL for acetylsalicylic acid (r2=0.9988), paracetamol (r2=0.9990) and caffeine (r2=0.9990), respectively. Intermediate precision (RSD interday) as low as 0.1-0.8% was found for retention times, while the RSD values for the peak area ratios (Aanalyte/AIS) were in the range of 1.9-2.9%. The optimized CEC method was applied to the analysis of the studied compounds present in commercial tablets.  相似文献   

7.
Malá Z  Gebauer P  Boček P 《Electrophoresis》2011,32(12):1500-1507
This paper deals with unwanted effects of carbonate in capillary zone electrophoretic analyses of anions in alkaline BGEs with indirect UV absorption and conductivity detection. Computer simulations and experimental study of selected model systems have shown that carbon dioxide absorbed from air into BGEs and samples induce important electrophoretic effects like formation of new additional zones and/or boundaries that may further induce strong and pronounced temporary changes in the migration of analytes. Examples are reduction of the pH of alkaline BGEs around pH 11 by up to 1 unit or formation of a pronounced detectable carbon dioxide peak comparable with peaks of analytes at 1 mM level. The higher the pH of the BGE, the stronger these effects and the broader their spectrum, involving (i) changes of effective mobilities and selectivity due to changes in pH of the BGE, (ii) occurrence of additional system zones appearing in form of peaks, dips or more complex disturbances in the detection signal, (iii) temporary interactions with the sample components and subsequent modification of the separation process and of its result. This paper reveals all these effects and brings the knowledge necessary to prevent problems with qualitative and quantitative evaluation of the analysis results.  相似文献   

8.
Liu L  Chen X  Hu Z 《Electrophoresis》2005,26(23):4456-4464
A novel, rapid, and continuous online concentration approach based on field-amplified sample injection for the analysis of fangchinoline and tetrandrine was developed in this paper by combination of flow injection-MEKC. The BGE used was a solution composed of 75 mM H3PO4-triethylamine-2.5% v/v polyoxyethylene sorbitan monolaurate-20% v/v methanol buffer (pH* 5.0). The analytes prepared in 50% v/v aqueous ethanol were used as the test analytes. Sample was injected electrokinetically between plugs of water. When the cations reached the boundary between the water plug and BGE, they slowed down and became concentrated. Thereafter, MEKC was initiated for the separation. This results in 6.8-8.9-fold improvement in concentration sensitivity relative to conventional CE methods. The separation could be achieved within 10 min and sample throughput rate can reach up to 50/h. The repeatability (defined as RSD) was 4.8, 4.4% with peak height evaluation and 3.6, 0.94% with peak area evaluation for TET and FAN, respectively.  相似文献   

9.
Antiseptic agent carbethopendecinium bromide (septonex) was determined by capillary electrophoresis with capacitively coupled contactless conductivity detection. Optimal separation of this quaternary ammonium ion was achieved in BGE of pH 7.0 containing 30 mM 2-(N-morpholino)ethanesulfonic acid, 12.5 mg/mL of 2-hydroxypropyl-β-cyclodextrin and 20% v/v of acetonitrile. The separation was performed at 25°C in an uncoated fused silica capillary (50 μm id; total length, 60.5 cm; effective length, 50 cm) at 30 kV. Samples were injected hydrodynamically at 50 mbar for 6 s. For quantitative analysis, L-arginine (500 μg/mL) was used as internal standard. The calibration curve was rectilinear for 25-400 μg/mL of septonex (y=0.0113x-0.0063; r(2)=0.9992). The LOD was 7 μg/mL of septonex (at S/N=3). The run-to-run repeatability (n=6) was characterized by the RSDs of 0.18% for the migration time and 1.96% for the analyte/internal standard peak area ratio. Accuracy tested by recovery experiments at three concentration levels gave recoveries of 100.27-104.22% with RSD ≤2.19%. The method was successfully applied to the assay of carbethopendecinium bromide in eye drops. Quaternary ammonium ions having structure and size close to that of carbethopendecinium may not be resolved from the analyte.  相似文献   

10.
A suite of 12 widely used pharmaceuticals (ibuprofen, diclofenac, naproxen, bezafibrate, gemfibrozil, ofloxacin, norfloxacin, carbamazepine, primidone, sulphamethazine, sulphadimethoxine and sulphamethoxazole) commonly found in environmental waters were separated by highly sulphated CD-modified MEKC (CD-MEKC) with UV detection. An experimental design method, face-centred composite design, was employed to minimize run time without sacrificing resolution. Using an optimized BGE composed of 10 mM ammonium hydrogen phosphate, pH 11.5, 69 mM SDS, 6 mg/mL sulphated beta-CD and 8.5% v/v isopropanol, a separation voltage of 30 kV and a 48.5 cm x 50 microm id bare silica capillary at 30 degrees C allowed baseline separation of the 12 analytes in a total analysis time of 6.7 min. Instrument LODs in the low milligram per litre range were obtained, and when combined with offline preconcentration by SPE, LODs were between 4 and 30 microg/L.  相似文献   

11.
The usefulness of a noncovalent capillary coating consisting of two layers of oppositely charged polymers for the separation of peptides with capillary electrophoresis (CE) was studied. Capillaries were coated simply by subsequently flushing with solutions of 1% m/v Polybrene and 1% v/v poly(vinylsulfonate) (PVS) forming a bilayer, which showed to produce a strong and highly reproducible electroosmotic flow (EOF) at low pH. Using this coating in combination with a background electrolyte (BGE) containing sodium phosphate (pH 2.5) and 0.01% v/v PVS, initially broadened and overlapping peaks were obtained for some test peptides. By omitting the PVS from the BGE, the peak width and shape of the peptides improved resulting in baseline separation. A systematic study of the influence of the BGE composition showed that considerable further enhancement of the separation efficiency was achieved by increasing the ionic strength of the BGE. Using a BGE of 200 mM tris(hydroxymethyl)aminomethane (Tris)-phosphate (pH 2.5) plate numbers for the peptides were in the 300 000-600 000 range and the relative standard deviation of the peptide migration times was less then 0.3% (n = 5). The use of Tris-phosphate instead of sodium phosphate allowed the current to stay within acceptable limits when 30 kV was used as separation voltage. Overall, the bilayer coating showed a remarkable EOF repeatability, as well as long-term stability. Compared to bare fused-silica capillaries the intraday and interday repeatability of migration times was very favorable and coated capillaries could be used for over a month performing analyses with low and high ionic strength BGEs without any performance deterioration. The usefulness of the bilayer-coated capillaries for the analysis of positively charged peptides was demonstrated by the fast and efficient separation of various closely related enkephalins and the baseline separation of an isomeric peptide/peptoid couple exhibiting efficiencies of over 550 000 plates.  相似文献   

12.
The fast separation capability of a novel miniaturized capillary electrophoresis with amperometric detection (CE-AD) system was demonstrated by determining sugar contents in Coke and diet Coke with an estimated separation efficiency of 60,000 TP/m. Factors influencing the separation and detection processes were examined and optimized. The end-capillary 300 microm Cu wire amperometric detector offers favorable signal-to-noise characteristics at a relatively low potential (+0.50 V vs. Ag/AgCl) for detecting sugars. Three sugars (sucrose, glucose, and fructose) have been separated within 330 s in a 8.5 cm length capillary at a separation voltage of 1000 V using a 50 mM NaOH running buffer (pH 12.7). Highly linear response is obtained for the above compounds over the range of 5.0 to 2.0 x 10(2) microg/mL with low detection limit, down to 0.8 microg/mL for glucose (S/N = 3). The injection-to-injection repeatability for analytes in peak current (RSD < 3.6%) and for migration times (RSD < 1.4%) was excellent. The new miniaturized CE-AD system should find a wide range of analytical applications involving assays of carbohydrates as an alternative to conventional CE and micro-CE.  相似文献   

13.
The incorporation of a cloud point extraction (CPE) step prior to capillary electrophoresis (CE) for simultaneously determining platinum and palladium at sub-microg/L levels is presented and evaluated. The analytes were extracted as 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol complexes, at pH 2.0, mediated by micelles of the nonionic surfactant polyethyleneglycolmono-p-nonylphenyl ether (PONPE 7.5). The separation-determination step was developed from 150 microL of the extracted surfactant-rich phase diluted with 50 microL of acetonitrile (ACN). An exhaustive study of the variables affecting the cloud point extraction with PONPE 7.5 and the CZE step was done. The type and composition of the background electrolytes (BGEs) were investigated with respect to separation selectivity, reproducibility, and stability. A BGE of 50 mM monobasic sodium phosphate containing 30% ACN, pH 4.53 was found to be optimal for the separation of metal chelates. Detection was performed at 576 nm. An enrichment factor of 250 was obtained for the preconcentration of 50 mL of sample solution. The detection limits for the preconcentration of 50 mL of sample were 0.04 microg/L for Pt and 0.08 microg/L for Pd. As an analytical demonstration, ultratrace concentrations of platinum and palladium were conveniently quantitated in spiked water and urine samples.  相似文献   

14.
In this work, a CE method with bare gold nanorods (GNRs) based pseudostationary phase was developed and applied for the separation of chondroitin sulfate (CS) isomers, CS, and dermatan sulfate (DS). The separation efficiency was investigated by varying the experimental parameters such as concentration and pH of the BGE, separation voltage, internal diameter of capillary, different size, and morphology of gold nanomaterials. Results showed that different size and morphology of gold nanomaterials had different effects on the separation of CS and DS. The best separation of CS and DS was achieved in the BGE composed of aqueous 150 mmol/L (mM) ethylenediamine + 20 mM sodium dihydrogen phosphate + 30% v/v GNRs, pH 4.5, at the separation voltage of ?10 kV. Capillary was 59.2 cm in length (effective length 49 cm), 50 μm id capillary thermostated at 25°C. CE with bare GNRs used as pseudostationary phase was shown to be a suitable technique for the separation of CS and DS mixtures with wider peaks. RSD of migration time and peak area of CS and DS were 0.13, 0.14 and 0.86, 1.07%, respectively.  相似文献   

15.
In this article the methodology of the design of suitable background electrolytes (BGEs) in capillary zone electrophoresis (CZE) is described. The principal aspects of the role of a BGE in CZE are discussed with respect to an appropiate migration behavior of analytes, including the transport of the electric current, the buffering of pH, the Joule heat, the electro-endosmotic flow (EOF) and the principal migration and detection modes. The impact of the composition of the BGE upon migration and detection is discussed. It is shown that the total concentration of the BGE is a principal factor and the adjustment of migrating analyte zones according to the Kohlrausch regulating function (KRF) is the principal effect in most of the sample stacking techniques. The number of co-ions and their properties are of key importance for peak shapes of the analyte peaks and for the existence of system zones. The detection of UV-transparent analytes may advanteously be done in the indirect UV mode, by using UV-absorbing co-ions, however, both peaks and dips may be expected in the UV trace in case of multiple co-ionic BGEs. Properties of BGEs can be predicted applying mathematical models and it is shown that with SystCharts, predictions can be given concerning the existence of system zones, detection modes and the peak shapes of analytes for a given BGE. Practical examples of methodological considerations are given in the design of suitable BGEs for four principal combinations of migration and detection modes. The properties of the BGEs selected are exemplified with experimental results. Golden rules are summarized for the preparation of suitable BGEs in CZE.  相似文献   

16.
A reversed-phase high-performance liquid chromatographic (RP-HPLC) method was described for the determination of chlorogenic acid (CGA) in rat plasma using protocatechuic acid as internal standard (IS). CGA in plasma was extracted with acetonitrile, which also acted as deproteinization agent. Chromatographic separation was performed on a Kromasil C18 column with methanol-0.2 m acetic acid (pH 3.0, 25:75, v/v) as mobile phase at a flow-rate of 1.0 mL/min with an operating temperature of 30 degrees C and UV detection at 300 nm. The standard curve was found to be linear over the concentration ranges of 0.4-2.5 microg/mL and 2.5-40 microg/mL, and the limit of quantification (LOQ) was 0.4 microg/mL. The analytical precision and accuracy were validated by relative standard deviation (RSD) and relative error, which were in ranges 3.14-10.78% and -2.20-5.00%, respectively. The average recovery of CGA was 87.59%. The method was successfully applied to the pharmacokinetic study of CGA in Yin-Huang granules.  相似文献   

17.
Capillary zone electrophoresis (CZE) has been applied to qualitative and quantitative analysis, separation and physicochemical characterization of synthetic gonadotropin-releasing hormones (GnRHs) and their analogs and fragments. Structurally related peptides were separated in conventional and isoelectric acidic background electrolytes (BGEs), pH 2.18-2.50. Best separation was achieved in isoelectric BGE composed of 200 mM iminodiacetic acid, pH 2.32. The effective electrophoretic mobilities, m(ep), of GnRHs in five BGEs were determined and four semiempirical models correlating effective mobility with charge, q, and relative molecular mass, M(r), (m(ep) versus q/M(r)(k), where k is related to the molecular shape) were tested to describe the migration behavior of GnRHs in CZE. None of the models was found to be quite definitively applicable for the whole set of 10 GnRHs differing in size (tetrapeptide-decapeptide) and positive charge (0.91-3.00 elementary charges). Nevertheless, for the dependence of m(ep) on q/M(r)(k), the highest coefficient of correlation, R=0.995-0.999, was obtained for k close to the value 0.5 in all five acidic BGEs. This indicates that the most probable structure of GnRHs in these BGEs can be predicted as a random coil.  相似文献   

18.
Li Y  Jiang Y  Yan XP 《Electrophoresis》2005,26(3):661-667
Capillary electrophoresis (CE) was directly interfaced to flame-heated furnace atomic absorption spectrometry (FHF-AAS) via a laboratory-made thermospray interface for nanoliter trace element speciation. The CE-FHF-AAS interface integrated the superiorities of stable CE separation, complete sample introduction, and continuous vaporization for AAS detection without the need of extra external heat sources and any post-column derivation steps. To demonstrate the usefulness of the developed hybrid technique for speciation analysis, three environmentally significant and toxic forms of methylmercury (MeHg), phenylmercury (PhHg), and inorganic mercury (Hg(II)) were taken as model analytes. Baseline separation of the three mercury species was achieved by CE in a 60 cm long x 75 microm inner diameter fused-silica capillary at 20 kV and using a mixture of 100 mM boric acid and 10% v/v methanol (pH 8.30) as running electrolyte. The precision (relative standard deviation, RSD, n = 7) of migration time, peak area and peak height for the mercury species at 500 microg x L(-1) (as Hg) level were in the range of 0.9-1.2%, 1.5-1.9%, and 1.4-2.0%, respectively. The detection limit (S/N = 3) of three mercury species was 3.0 +/- 0.15 pg (as Hg), corresponding to 50.8 +/- 2.4 microg x L(-1) (as Hg) for 60 nL sample injection, which was almost independent on specific mercury species. The developed hybrid technique was successfully applied to the speciation analysis of mercury in a certified reference material (DORM-2, dogfish muscle).  相似文献   

19.
A generic approach has been developed for coupling capillary electrophoresis (CE) using non-volatile background electrolytes (BGEs) with mass spectrometry (MS) using a sheath liquid interface. CE-MS has been applied for basic and bi-functional compounds using a BGE consisting of 100 mM of TRIS adjusted to pH 2.5 using phosphoric acid. A liquid sheath effect is observed which may influence the CZE separation and hence may complicate the correlation between CE-UV and CE-MS methods. The influence of the liquid sheath effect on the migration behavior of basic pharmaceuticals has been studied by simulation experiments, in which the BGE outlet vial is replaced by sheath liquid in a CE-UV experiment. As a consequence of the liquid sheath effect, phosphate based BGEs can be used without significant loss of MS sensitivity compared to volatile BGEs. The use of buffer constituents such as TRIS can lead to lower detection limits as loss of MS sensitivity can be compensated by better CE performance. TRIS based BGEs permit relatively high injection amounts of about 100 pmol while maintaining high resolution. The ESI-MS parameters were optimized for a generic method with maximum sensitivity and stable operation, in which the composition of the sheath liquid and the position of the capillary were found to be important. Furthermore, the nebulizing pressure strongly influenced the separation efficiency. The system showed stable performance for several days and a reproducibility of about 15% RSD in peak area has been obtained. Nearly all test compounds used in this study could be analyzed with an MS detection limit of 0.05% measured in scan mode using extracted ion chromatograms. As a result, CE-MS was found to be a valuable analytical tool for pharmaceutical impurity profiling.  相似文献   

20.
A simple CZE method for quantification of phenolic compounds (vanillin, cinnamic, sinapic, chlorogenic, syringic, ferulic, benzoic, p-coumaric, vanillic, p-hydroxybenzoic, rosmarinic, caffeic, gallic and protocatechuic acids) in less than 10 min using 20 mM sodium tetraborate (pH 9.2) with 5% v/v methanol as a BGE and with UV detection at 254 nm is described. The LODs (3 S/N) ranged between 0.02 and 0.12 microg/ mL. Repeatabilities (RSDs) were 0.66-1.8 and 1.56-4.23% for migration times and peak areas (n = 5), respectively. The method was applied to the determination of phenolic compounds in chess (Bromus inermis L.) after Soxhlet extraction and purification of the crude extracts with SPE procedures. The results compared well with those obtained by liquid chromatographic method. B. inermis was found as a suitable model plant containing a broad spectrum of phenolic compounds in easily detectable concentrations and as a potential source of antioxidants.  相似文献   