首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Matrix-assisted laser desorption/ionization (MALDI) and time-of-flight secondary ion mass spectrometry (ToF-SIMS) analyses are compared to gain insight into some of the details of sample preparation for MALDI analysis of synthetic polymers. ToF-SIMS imaging of MALDI samples shows segregation of the cationization agent from the matrix crystals. The amount of observed segregation can be controlled by the sample preparation technique. Electrospray sample deposition minimizes segregation. Comparing ToF-SIMS and MALDI mass spectra from the same samples confirms that ToF-SIMS is significantly more surface sensitive than MALDI. This comparison shows that segregation of the oligomers of a polymer sample can occur during MALDI sample preparation. Our data indicate that MALDI is not as sensitive to those species dominating the sample surface as to species better incorporated into the matrix crystals. Finally, we show that matrix-enhanced SIMS can be an effective tool to analyze synthetic polymers, although the sample preparation conditions may be different than those optimized for MALDI.  相似文献   

2.
Although electrospray sample deposition in matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) sample preparation increases the repeatability of both the MALDI signal intensity and the measured molecular mass distribution (MMD), the electrospray sample deposition method may influence the apparent MMD of a synthetic polymer. The MMDs of three polymers of differing thermal stability, polystyrene (PS), poly(ethylene glycol) (PEG), and poly(propylene glycol) (PPG), were studied by MALDI time-of-flight (TOF) MS as the electrospray deposition voltage was varied. The MMDs obtained using the electrospray deposition method were compared with those obtained for hand-spotted samples. No change was observed in the measured polymer MMD when the electrospray deposition voltage was varied in the analysis of PS, but those of PEG and PPG changed at higher electrospray voltages due to increased ion fragmentation. It was also shown that the fragmentation in the hand-spotted samples is dependent on the matrix used in sample preparation.  相似文献   

3.
Preparation of samples according to an optimized method is crucial for accurate determination of polymer sample characteristics by Matrix-Assisted Laser Desorption Ionization (MALDI) analysis. Sample preparation conditions such as matrix choice, cationization agent, deposition technique or even the deposition volume should be chosen to suit the sample of interest. Many sample preparation protocols have been developed and employed, yet finding the optimal sample preparation protocol remains a challenge. Because an objective comparison between the results of diverse protocols is not possible, “gut-feeling” or “good enough” is often decisive in the search for an optimum. This implies that sub-optimal protocols are used, leading to a loss of mass spectral information quality. To address this problem a novel analytical strategy based on MALDI imaging and statistical data processing was developed in which eight parameters were formulated to objectively quantify the quality of sample deposition and optimal MALDI matrix composition and finally sum up to an overall quality score of the sample deposition. These parameters can be established in a fully automated way using commercially available mass spectrometry imaging instruments without any hardware adjustments. With the newly developed analytical strategy the highest quality MALDI spots were selected, resulting in more reproducible and more valuable spectra for PEG in a variety of matrices. Moreover, our method enables an objective comparison of sample preparation protocols for any analyte and opens up new fields of investigation by presenting MALDI performance data in a clear and concise way.  相似文献   

4.
Electrospray mass spectrometry (ES/MS) and matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI/TOF/MS) were used to provide mass spectra from seven elapid snake venoms. Spectral interpretation was much simpler for MALDI/TOF/MS. ES/MS proved more useful for the provision of molecular weight data for very closely related peptides, but suppression of higher molecular weight compounds was seen to occur during flow injection analysis. MALDI/TOF/MS proved useful for providing a complete picture of the venom, but the low resolution led to obscuring of major ions, and the mass accuracy was poorer for known peptides. Suppression also occurred during MALDI/TOF/MS but could be overcome using alternative matrices because the spectra were very dependent on the choice of matrix. ES/MS and MALDI/TOF/MS provide complementary and confirmatory information such that for the anal sis of complex peptide mixtures (snake venoms), the use of both techniques is desirable.  相似文献   

5.
Matrix-assisted laser desorption/ionization (MALDI) mass spectrometry is an important technique to characterize many different materials, including synthetic polymers. MALDI mass spectral data can be used to determine the polymer average molecular weights, repeat units, and end groups. The development of solvent-free sample preparation methods has enabled MALDI to analyze insoluble materials and, interestingly, can provide higher-quality mass spectral data. Although the utility of solvent-free sample preparation for MALDI has been demonstrated, the reasons for its success are only now being discovered. In this study, we use microscopy tools to image samples prepared using solvent-free methods to examine the morphology of these samples. The samples are prepared using a simple vortex method. Our results show that the average particle size of typical MALDI matrices is reduced from their original tens to hundreds of micrometers to hundreds of nanometers. This size reduction of the matrix occurs in one minute using the vortex method. We also observe remarkably smooth and homogeneous sample morphologies for the laser to interrogate, especially considering the relatively crude methods used to prepare our samples.  相似文献   

6.
The applicability of matrix-assisted laser desorption/ionization time of flight mass spectrometry (MALDI-TOF MS) to the analysis of wax esters (WEs) was investigated. A series of metal salts of 2,5-dihydroxybenzoic acid (DHB) was synthesized and tested as possible matrices. Alkali metal (Li, Na, K, Rb, Cs) and transition metal (Cu, Ag) salts were studied. The matrix properties were evaluated, including solubility in organic solvents, threshold laser power that should be applied for successful desorption/ionization of WEs, the nature of the matrix ions and the mass range occupied by them, and the complexity of the isotope clusters for individual metals. Lithium salt of dihydroxybenzoic acid (LiDHB) performed the best and matrices with purified lithium isotopes ((6)LiDHB or (7)LiDHB) were recommended for WEs. Three sample preparation procedures were compared: (1) mixing the sample and matrix in a glass vial and deposition of the mixture on a MALDI plate (Mix), (2) deposition of sample followed by deposition of matrix (Sa/Ma), and (3) deposition of matrix followed by deposition of sample (Ma/Sa). Morphology of the samples was studied by scanning electron microscopy. The best sample preparation technique was Ma/Sa with the optimum sample to matrix molar ratio 1 : 100. Detection limit was in the low picomolar range. The relative response of WEs decreased with their molecular weight, and minor differences between signals of saturated and monounsaturated WEs were observed. MALDI spectra of WEs showed molecular adducts with lithium [M + Li](+). Fragments observed in postsource decay (PSD) spectra were related to the acidic part of WEs [RCOOH + Li](+) and they were used for structure assignment. MALDI with LiDHB was used for several samples of natural origin, including insect and plant WEs. A good agreement with GC/MS data was achieved. Moreover, MALDI allowed higher WEs to be analyzed, up to 64 carbon atoms in Ginkgo biloba leaves extract.  相似文献   

7.
A direct sample fraction deposition method was developed for off-line size-exclusion chromatography (SEC)/matrix-assisted laser desorption/ionization (MALDI) time-of-flight mass spectrometry. By using electrospray, the SEC eluent, together with a suitable matrix solution added coaxially, was directly deposited on the MALDI plate. Owing to the formation of very small droplets in electrospray, solvent evaporation is much faster. The fractionation volume in narrow-bore SEC, which can directly be collected in one MALDI spot, can easily be optimized in the range of a few microlitres. In addition, fairly homogeneous sample spots were obtained. The possible influence of composition variation of the SEC effluent on the analytical results using direct fraction deposition was investigated; no substantial effects were observed. The applicability of the method was demonstrated by characterizing a broad poly(methyl methacrylate) sample. Copyright 2000 John Wiley & Sons, Ltd.  相似文献   

8.
9.
The identification of pharmacologically promising compounds (lead compounds) from combinatorial libraries is frequently limited by the throughput of the analytical technique employed. Fourier transform mass spectrometry (FTMS) offers high sensitivity, mass accuracy (m/Deltam > 500 000), and sequencing capabilities. A rapid and efficient method for high-throughput analysis of single beads from peptide-encoded combinatorial libraries with matrix-assisted laser desorption/ionization (MALDI) mass spectrometry is presented. Encoding peptides on single beads are identified and structurally characterized by MALDI time-of-flight (TOF) and ultrahigh-resolution MALDI Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry. A strategy of on-probe sample preparation is developed to minimize handling of the beads.  相似文献   

10.
The major obstacle in the use of matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) instruments in the analysis of complex proteome samples is the lack of a direct coupling of a highly resolving separation technique with the mass spectrometer itself. To overcome this drawback, a spotting device for capillary and nanoflow liquid chromatography (LC) with a special liquid deposition principle for lowest volumes was developed. The instrument is able to perform MALDI spotting in real time in order to deposit the LC run on the MALDI plate, and therefore couples the high resolution power of nano-RP-HPLC separation directly with MALDI-MS. This work describes the development and optimization of a method for spotting with online matrix addition, and illustrates its use in the analysis of a complex proteome sample.  相似文献   

11.
MALDI-MS imaging of features smaller than the size of the laser beam   总被引:1,自引:0,他引:1  
The feasibility of matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) imaging of features smaller than the laser beam size has been demonstrated. The method involves the complete ablation of the MALDI matrix coating the sample at each sample position and moving the sample target a distance less than the diameter of the laser beam before repeating the process. In the limit of complete sample ablation, acquiring signal from adjacent positions spaced by distances smaller than the sample probe enhances image resolution as the measured analyte signal only arises from the overlap of the laser beam size and the non-ablated sample surface. Image acquisition of features smaller than the laser beam size has been demonstrated with peptide standards deposited on electron microscopy calibration grids and with neuropeptides originating from single cells. The presented MS imaging technique enables approximately 25 microm imaging spatial resolution using commercial MALDI mass spectrometers having irregular laser beam sizes of several hundred micron diameters. With appropriate sampling, the size of the laser beam is not a strict barrier to the attainable MALDI-MS imaging resolution.  相似文献   

12.
Matrix-assisted laser desorption/ionization (MALDI) mass spectrometry is an important technique to characterize many different materials, including synthetic polymers. MALDI mass spectral data is used to determine the polymer average molecular weights, repeat units, and end groups. The development of the vortex method of solvent-free sample preparation showed that remarkably short mixing times could prepare samples that yielded high quality MALDI mass spectra. In this paper, we use microscopy images and MALDI mass spectra to evaluate the mixing time required by the vortex method to produce mass spectra for low molecular mass polymer samples. Our results show that mixing times of as little as 10 s can generate homogeneous thin films that produce high quality mass spectra with S/N ∼ 100. In addition, ultrashort mixing times of only 2 s still produce samples with mostly smooth morphology and mass spectra with S/N ∼ 10.  相似文献   

13.
Continuous spray deposition (CSD) of aqueous solutions of partially depolymerised methyl cellulose was found to improve matrix-assisted laser desorption/ionisation (MALDI) sample preparation. One feature was that the sensitivity in MALDI time-of-flight mass spectrometry increased up to an order of magnitude compared with the standard sample preparation method. Another feature was that CSD provided targets for MALDI with homogeneously distributed analyte. This resulted in a more even signal intensity and a higher reproducibility than in the standard method. High-mass discrimination was more pronounced in CSD than in the standard method. Size-exclusion chromatography with aqueous eluent was coupled online to CSD onto matrix-precoated foils. The suitability for determination of the molar mass distribution of methyl cellulose was investigated.  相似文献   

14.
The development of reliable sample preparation methods has been critical to the success of matrix-assisted laser desorption/ionization (MALDI) mass spectrometry experiments. Good MALDI sample preparation for polymers involves choosing the solvent system, the matrix, and the ionization agent correctly, and combining them in a manner that will lead to a sample that will produce the desired ions. The vast diversity of chemistry available in industrial polymers has challenged our ability to design reliable sample preparation methods. In the experiments reported here, we show that matrix-enhanced secondary ion mass spectrometry (MESIMS) is an effective analytical technique to explore sample segregation in solid phase MALDI samples. Qualitative comparison of MESIMS and MALDI results for polymer samples prepared with multiple matrices aids our investigation of the solid-phase solubility of a variety of low molecular weight polymer materials. Including the solid-phase solubility with the liquid-phase solubility of the polymer samples and the matrices enables the construction of a relative solubility chart, which shows the best solubility matches between the polymer and matrix materials for MALDI experiments.  相似文献   

15.
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) is used as an alternative method for the rapid diagnosis of albuminuria. This technique requires no further sample pretreatment than simply mixing the urine sample with a MALDI matrix and drying under ambient conditions. The resulting MALDI mass spectra reveal albumin ions having charges ranging from +1 to +5. The detection of albumin is possible using any of the three most common MALDI matrices - sinapinic acid (SA), 2,5-dihydroxybenzoic acid (2,5-DHB), or 4-hydroxy-alpha-cyanocinnamic acid (alpha-CHC). Using this analytical approach, the limit of detection for albumin in urine is 10(-6) M, approximately 5 to 10 times lower than that detectable through conventional chemical testing.  相似文献   

16.
Poloxamers are polyethylene-polypropylene glycol linear co-polymers. A simple matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) method has been developed for the determination of the average molecular weight of poloxamers. The molecular mass of five standard poloxamers determined by MALDI closely corresponds to that specified by the manufacturers, and no mass distribution effects were observed. Quantitation of distributions based on the molecular mass envelope using electrospray (ES) ionization was unsuccessful. To overcome this problem, quantitation was based on fragment ions (m/z 45 and 59) which gave reproducible signals using a very high orifice voltage ( approximately 200 eV). Poloxamer concentrations were determined accurately with a good linear response using the standard addition method. We believe that the use of very small fragment ions for quantitation of polymers may become a widely applicable general technique.  相似文献   

17.
This paper focuses on the technical aspects of chemical screening from 384-well plate nano-scale single-bead combinatorial libraries. The analytical technique utilized is a combination of capillary liquid chromatography with ultraviolet detection and matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. The HPLC/MALDI-MS hyphenation is achieved by means of a micro-fraction collector with a peak detection system that automatically collects the peaks onto the MALDI targets for subsequent characterization. Several experimental parameters such as type of 384-well plate, well-plate sealing foils, and a column-switching procedure were investigated using a small test library of nine components. Additionally, the influence of different MALDI matrices, different MALDI targets and sample-spotting techniques on the MALDI detection sensitivity as well as the ruggedness and sample throughput capacity of this technique were studied. Optimum results for the analytes investigated were obtained with 2,5-dihydroxybenzoic acid using on-line mixing of HPLC effluent and matrix solution. To demonstrate the potential of this capillary HPLC/MALDI-TOFMS method, its application to several single-bead libraries was investigated. The instrumental method allowed for the rapid identification and purity assessment of combinatorial libraries with detection limits down to the higher femtomole level using both UV detection and MALDI mass spectrometry.  相似文献   

18.
We report the development of a solid‐phase proteolytic digestion and continuous deposition microfluidic chip platform for low volume fraction collection and off‐line matrix‐assisted laser desorption/ionization time‐of‐flight (MALDI‐TOF) mass spectrometry. Tryptic peptides were formed in an on‐chip bioreactor and continuously deposited onto a MALDI target plate using a motor‐driven xyz stage. The bioreactor consisted of a 4 cm × 200 µm × 50 µm microfluidic channel with covalently immobilized trypsin on an array of 50 µm diameter micropost structures with a 50 µm edge‐to‐edge inter‐post spacing. A 50 µm i.d. capillary tube was directly attached to the end of the bioreactor for continuous sample deposition. The MALDI target plate was modified by spin‐coating a nitrocellulose solution containing a MALDI matrix on the surface prior to effluent deposition. Protein molecular weight standards were used for evaluating the performance of the digestion and continuous deposition system. Serpentine sample traces 200 µm wide were obtained with a 30 fmol/mm quantity deposition rate and a 3.3 nL/mm volumetric deposition rate. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

19.
Charged droplet processing methodology, that utilizes electrodynamic levitation technology to control the trajectories of picoliter volume charged droplets and deliver them to a target plate at atmospheric pressure, has been developed. Termed wall-less sample preparation (WaSP), this methodology offers several features that could prove beneficial to the preparation of sample spots from separation column effluents for matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) analysis. These features include solute pre-concentration factors of 10(1) to 10(3) due to volatile solvent evaporation prior to droplet deposition onto the target plate, high spatial accuracy of the deposition position of each processed droplet (+/-5 microm), and the ability to prepare sample spots as small as 20 microm in diameter from a single droplet. Here a new mode of operation of this methodology is described and used as an offline post-column pre-concentrating interface between capillary liquid chromatography (capLC) and a target plate for offline MALDI-MS. Using a fraction from the capLC separation of peptides produced by the proteolytic digestion of the protein cytidine 5'-triphosphate:phosphocholine cytidylyltransferase, MALDI sample spots were prepared using the dried-droplet method, direct piezoelectric droplet dispensing, and the processing of piezo-dispensed droplets by WaSP. The sample spot morphology was investigated using light microscopy, and peptide ion abundances produced by MALDI were measured using time-of-flight (TOF) MS. The advantages of developing an online capLC/WaSP interface with MALDI-MS in the future are discussed along with some of the challenges that may be encountered in such an endeavor.  相似文献   

20.
Common organic matrix-assisted laser desorption/ionization (MALDI) matrices, 2,5-dihydroxybenzoic acid, 3,5-dimethoxy-4-hydroxycinnamic acid, and alpha-cyano-4-hydroxycinnamic acid, were found to undergo sublimation without decomposition under conditions of reduced pressure and elevated temperature. This solid to vapor-phase transition was exploited to apply MALDI matrix onto tissue samples over a broad surface in a solvent-free application for mass spectrometric imaging. Sublimation of matrix produced an even layer of small crystals across the sample plate. The deposition was readily controlled with time, temperature, and pressure settings and was highly reproducible from one sample to the next. Mass spectrometric images acquired from phospholipid standards robotically spotted onto a MALDI plate yielded a more intense, even signal with fewer sodium adducts when matrix was applied by sublimation relative to samples where matrix was deposited by an electrospray technique. MALDI matrix could be readily applied to tissue sections on glass slides and stainless steel MALDI plate inserts as long as good thermal contact was made with the condenser of the sublimation device. Sections of mouse brain were coated with matrix applied by sublimation and were imaged using a Q-q-TOF mass spectrometer to yield mass spectral images of very high quality. Image quality is likely enhanced by several features of this technique including the microcrystalline morphology of the deposited matrix, increased purity of deposited matrix, and evenness of deposition. This inexpensive method was reproducible and eliminated the potential for spreading of analytes arising from solvent deposition during matrix application.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号