首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A capillary electrophoresis with capacitively coupled contactless conductivity detection based method for the assay of azithromycin, clarithromycin and clindamycin was optimized and validated in this study. A buffer solution of 20 mM 2‐(N‐morpholino) ethane sulfonic acid, 40 mM l ‐histidine and 0.6 mM cetyltrimethylammonium bromide (pH 6.39) was used for the electrophoresis. An uncoated, bare‐fused silica capillary (total length 60 cm, effective length 32 cm, 75 μm id) was used at 25°C. The sample was injected hydrodynamically at 0.5 psi for 5 s. The electrophoresis was conducted at 30 kV in reverse polarity for 6 min with 3 and 2 min of in‐between sodium hydroxide (0.1 M) and background electrolyte rinsing, respectively. Ammonium acetate was used as internal standard. This simple and robust method showed reasonable limit of detection and limit of quantitation for azithromycin (0.0125/0.03 mg/mL), clarithromycin (0.017/0.03 mg/mL), and clindamycin (0.038/0.06 mg/mL), with good selectivity, precision both intraday (relative standard deviation ≤ 1.0%) and interday (relative standard deviation < 3.7%), linearity (R 2 > 0.999) and recovery (99 – 101.7%). The method was successfully applied for the determination of azithromycin, clarithromycin and clindamycin in formulations.  相似文献   

2.
Electromembrane extraction (EME) proved to be a simple and rapid pretreatment method for analysis of amino acids and related compounds in body fluid samples. Body fluids were acidified to the final concentration of 2.5 M acetic acid and served as donor solutions. Amino acids, present as cations in the donor solutions, migrated through a supported liquid membrane (SLM) composed of 1-ethyl-2-nitrobenzene/bis-(2-ethylhexyl)phosphonic acid (85:15 (v/v)) into the lumen of a porous polypropylene hollow fiber (HF) on application of electric field. The HF was filled with 2.5 M acetic acid serving as the acceptor solution. Matrix components in body fluids were efficiently retained on the SLM and did not interfere with subsequent analysis. Capillary electrophoresis with capacitively coupled contactless conductivity detection was used for determination of 17 underivatized amino acids in background electrolyte solution consisting of 2.5 M acetic acid. Parameters of EME, such as composition of SLM, pH and composition of donor and acceptor solution, agitation speed, extraction voltage, and extraction time were studied in detail. At optimized conditions, repeatability of migration times and peak areas of 17 amino acids was better than 0.3% and 13%, respectively, calibration curves were linear in a range of two orders of magnitude (r(2)=0.9968-0.9993) and limits of detection ranged from 0.15 to 10 μM. Endogenous concentrations of 12 amino acids were determined in EME treated human serum, plasma, and whole blood. The method was also suitable for simple and rapid pretreatment and determination of elevated concentrations of selected amino acids, which are markers of severe inborn metabolic disorders.  相似文献   

3.
Antiseptic agent carbethopendecinium bromide (septonex) was determined by capillary electrophoresis with capacitively coupled contactless conductivity detection. Optimal separation of this quaternary ammonium ion was achieved in BGE of pH 7.0 containing 30 mM 2-(N-morpholino)ethanesulfonic acid, 12.5 mg/mL of 2-hydroxypropyl-β-cyclodextrin and 20% v/v of acetonitrile. The separation was performed at 25°C in an uncoated fused silica capillary (50 μm id; total length, 60.5 cm; effective length, 50 cm) at 30 kV. Samples were injected hydrodynamically at 50 mbar for 6 s. For quantitative analysis, L-arginine (500 μg/mL) was used as internal standard. The calibration curve was rectilinear for 25-400 μg/mL of septonex (y=0.0113x-0.0063; r(2)=0.9992). The LOD was 7 μg/mL of septonex (at S/N=3). The run-to-run repeatability (n=6) was characterized by the RSDs of 0.18% for the migration time and 1.96% for the analyte/internal standard peak area ratio. Accuracy tested by recovery experiments at three concentration levels gave recoveries of 100.27-104.22% with RSD ≤2.19%. The method was successfully applied to the assay of carbethopendecinium bromide in eye drops. Quaternary ammonium ions having structure and size close to that of carbethopendecinium may not be resolved from the analyte.  相似文献   

4.
A simple, rapid method using CE and microchip electrophoresis with C4D has been developed for the separation of four nonsteroidal anti-inflammatory drugs (NSAIDs) in the environmental sample. The investigated compounds were ibuprofen (IB), ketoprofen (KET), acetylsalicylic acid (ASA), and diclofenac sodium (DIC). In the present study, we applied for the first time microchip electrophoresis with C4D detection to the separation and detection of ASA, IB, DIC, and KET in the wastewater matrix. Under optimum conditions, the four NSAIDs compounds could be well separated in less than 1 min in a BGE composed of 20 mM His/15 mM Tris, pH 8.6, 2 mM hydroxypropyl-beta-cyclodextrin, and 10% methanol (v/v) at a separation voltage of 1000–1200 V. The proposed method showed excellent repeatability, good sensitivity (LODs ranging between 0.156 and 0.6 mg/L), low cost, high sample throughputs, portable instrumentation for mobile deployment, and extremely lower reagent and sample consumption. The developed method was applied to the analysis of pharmaceuticals in wastewater samples with satisfactory recoveries ranging from 62.5% to 118%.  相似文献   

5.
A capillary electrophoresis (CE) instrument with capacitively coupled contactless conductivity detection (C4D) based on a sequential injection analysis (SIA) manifold was refined. Hydrodynamic injection was implemented to avoid a sampling bias by using a split-injection device based on a needle valve for precise adjustment. For safety and reliability, the integrity of the high voltage compartment at the detection end was fully maintained by implementing flushing of the high voltage interface through the capillary. With this set-up, extended fully automated monitoring applications are possible. The system was successfully tested in the field for the determination of the concentration levels of major inorganic cations and anions in a creek over a period of 5 days.  相似文献   

6.
Law WS  Kubán P  Zhao JH  Li SF  Hauser PC 《Electrophoresis》2005,26(24):4648-4655
The separation and detection of commonly used preservatives (benzoate, sorbate) and vitamin C by both conventional CE and microchip electrophoresis with capacitively coupled contactless conductivity detection is presented. The separation was optimized by adjusting the pH-value of the buffer and the use of hydroxypropyl-beta-CD (HP-beta-CD) and CTAB as additives. For conventional CE, optimal separation conditions were achieved in a histidine/tartrate buffer at pH 6.5, containing 0.025% HP-beta-CD and 0.1 mM CTAB. LOD ranged from 0.5 to 3 mg/L (S/N = 3) and the RSDs for migration time and peak area were less than 0.1 and 2%, respectively. A considerable reduction of analysis time can be accomplished by using microchip electrophoresis without significant loss in sensitivity under optimal separation conditions. A histidine/tartrate buffer at pH 6.5, incorporating 0.06% HP-beta-CD and 0.25 mM CTAB, gave detection limits ranging between 3 and 10 mg/L and satisfactory reproducibilities of < or =0.4% for the migration time and < or =3.5% for the peak area. The methods developed are useful for the quantitative determination of food additives in real samples such as soft drinks and vitamin C tablets.  相似文献   

7.
An optimized capacitively coupled contactless conductivity detector for microchip electophoresis is presented. The detector consists of a pair of top–bottom excitation electrodes and a pair of pickup electrodes disposed onto a very thin plastic microfluidic chip. The detection cell formed by the electrodes is completely encased and shielded in a metal housing. These approaches allow for the enhancement of signal coupling and extraction from the detection cell that result in an improved signal‐to‐noise‐ratio and detection sensitivity. The improved detector performance is illustrated by the electrophoretic separation of six cations (NH, K+, Ca2+, Na+, Mg2+, Li+) with a detection limit of approximately 0.3 μM and the analysis of the anions (Br?, Cl?, NO, NO, SO, F?) with a detection limit of about 0.15 μM. These LODs are significantly improved compared with previous reports using the conventional top–top electrode geometry. The developed system was applied to the analysis of ions in bottled drinking water samples.  相似文献   

8.
Capacitively coupled contactless conductivity detection (C4D) has appeared as a powerful technique for the detection of compounds lacking chromogenic or fluorogenic group. Since our last review (Biomedical Chromatography 2014; 28 : 1502–1506) several new capillary electrophoresis (CE)‐C4D methods have been reported. This review provides an update of the most recent utilization of CE‐C4D in the field of pharmaceutical, biomedical and food analysis covering the period from February 2014 to October 2016. The use of CE with C4D in the pharmaceutical field has been shown in many papers. Examples illustrate the applicability of CE‐C4D in the fields of pharmaceutical, biomedical and food analysis. Finally, general conclusions and perspectives are provided.  相似文献   

9.
Conductivity detection, which is universal in capillary electrophoresis (CE), has received considerable attention, since the introduction of the axial capacitively coupled contactless detector C4D in 1998. This detector is made of two electrodes which are placed cylindrically around the CE capillary and connected to the AC oscillator. The distance between the electrodes is the detection gap. In this review, applications of CE and MCE with C4D in pharmaceutical and biological analysis are presented.  相似文献   

10.
A fast separation of alkali and alkaline earth metal cations and ammonium was carried out by capillary electrochromatography on monolithic octadecylsilica columns of 15 cm length and 100 μm inner diameter using water/methanol mixtures containing acetic acid as mobile phase. On-column contactless conductivity detection was used for quantification of these non-UV-absorbing species. The method was also extended successfully to the determination of small amines as well as of amino acids, and the separation selectivity was optimized by varying the composition of the mobile phase. Detection limits of about 1 μM were possible for the inorganic cations as well as for the small amines, while the amino acids could be quantified down to about 10 μM. The separation of 12 amino acids was achieved in the relatively short time of 10 min.  相似文献   

11.
Law WS  Kubán P  Yuan LL  Zhao JH  Li SF  Hauser PC 《Electrophoresis》2006,27(10):1932-1938
A study on the determination of the antibiotic tobramycin by CE with capacitively coupled contactless conductivity detection is presented. This method enabled the direct quantification of the non-UV-absorbing species without incurring the disadvantages of the indirect approaches which would be needed for optical detection. The separation of tobramycin from inorganic cations present in serum samples was achieved by optimizing the composition of the acetic acid buffer. Field-amplified sample stacking was employed to enhance the sensitivity of the method and a detection limit of 50 microg/L (S/N = 3) was reached. The RSDs obtained for migration time and peak area using kanamycin B as internal standard were typically 0.12 and 4%, respectively. The newly developed method was validated by measuring the concentration of tobramycin in serum standards containing typical therapeutic concentrations of 2 and 10 mg/L. The recoveries were 96 and 97% for the two concentrations, respectively.  相似文献   

12.
现有自由流电泳(FFE)装置因不具备在线检测功能,其实用性仍然存在明显不足.针对这一问题,该工作发展了一种多通道电容耦合式非接触电导检测(MC-C4 D)装置并开发了自动测量软件.MC-C4 D装置采用了并行分时的非接触电导检测技术,即由多个同样的非接触电导检测模块并行排列,而单个电导检测模块又由多个非接触电导检测池组...  相似文献   

13.
A new method for the rapid determination of the metabolites oxalate and citrate in urine samples was based on capillary electrophoresis and capacitively coupled contactless conductivity detection coupled with solid‐phase extraction. The detection cell for capacitively coupled contactless conductivity detection was improved with a smaller inner volume (1.5 nL), reduced noise (0.2∼0.5 mV) and better reproducibility and durability. Under optimal conditions, oxalate and citrate can achieve baseline separation within 4 min and the detection limits (S/N = 3) for oxalate and citrate are about 44 and 244 ng/mL, respectively. The overall recovery is between 80.0 and 89.2%. This method offers a better choice for quantitative analysis of strong anions such as oxalate and citrate in diagnostic testing associated with human diseases.  相似文献   

14.
The suitability of capillary electrophoresis (CE) with capacitively coupled contactless conductivity detection (C4D) for the direct determination of uric acid in human plasma and urine was investigated. It was found that a careful optimization of the buffer composition and pH was necessary to achieve selective determination in the complex sample matrices. An electrolyte solution consisting of 10 mM 2-morpholinoethanesulfonic acid (MES), 10 mM histidine and 0.1 mM hexadecyltrimethylammonium bromide (CTAB), pH 6.0, was finally found suitable for use as running buffer for both sample matrices. The limit of detection (3 S/N) was determined as 3.3 μM. The linearity of the response was tested for the range between 10 and 500 μM and a correlation coefficient of 0.9996 was obtained. Intra- and inter-day variabilities were <10%. Quantitative analysis of urine and plasma samples showed a good correlation with the routine enzymatic method currently used at the University Hospital of Basel.  相似文献   

15.
A method to determine five fluoroquinolones (FQs), namely, rufloxacin (RUF), ciprofloxacin (CIP), enrofloxacin (ENO), gatifloxacin (GAT) and moxifloxacin (MOX), in acidic buffer by capillary electrophoresis (CE)-capacitively coupled contactless conductivity detection (C4D) technique is presented. Separation was carried out in a fused-silica capillary (42 cm × 50 μm) using a buffer composed of 10 mM tartaric acid, 14 mM sodium acetate and 15% (v/v) methanol at pH 3.8. The RSDs of the migration times and peak areas were 0.65% and 12.3% (intraday), 1.28% and 8.8% (interday), respectively. CE-C4D in combination with liquid–liquid extraction (LLE) as clean-up and preconcentration procedure, allows detection of the FQs in fortified chicken muscle samples with detection limits of 6.8–11.7 ng/g. This method shows potential in rapid determination of FQs in samples with complex matrix.  相似文献   

16.
Capacitively coupled contactless conductivity detection (C4D) in the axial electrode configuration was introduced in 1998 as a quantification method for capillary electrophoresis. Its universality allows the detection of small inorganic ions as well as organic and biochemical species. Due to its robustness, minimal maintenance demands and low cost the popularity of this detector has been steadily growing. Applications have recently also been extended to other analytical methods such as ion chromatography, high-performance liquid chromatography and flow-injection analysis. C4D has also found use for detection on electrophoresis based lab-on-chip devices. Theoretical aspects of C4D in both the capillary and microchip electrophoresis format have been comprehensively investigated. Commercial devices are now available and the method can be considered a mature detection technique. In this article, the achievements in C4D for the time period between September 2004 and August 2007 are reviewed.  相似文献   

17.
Contactless conductivity detection is successfully demonstrated for the enantiomeric separation of basic drugs and amino acids in capillary electrophoresis (CE). Derivatization of the compounds or the addition of a visualization agent as for indirect optical detection schemes were not needed. Non-charged chiral selectors were employed, hydroxypropylated cyclodextrin (CD) for the more lipophilic basic drugs and 18-crown-6-tetracarboxylic acid (18C6H4) for the amino acids. Acidic buffer solutions based on lactic or citric acid were used. The detection limits were determined as 0.3 microM for pseudoephedrine as an example of a basic drug and were in the range from 2.5 to 20 microM for the amino acids.  相似文献   

18.
谭峰  杨丙成  关亚风 《分析化学》2005,33(3):313-316
利用自研制的电容耦合非接触电导检测器,结合毛细管电泳技术,以2-N-吗啡啉乙磺酸(MES)/组氨酸(His)为缓冲溶液,采用双端进样方式,同时分离测定了5种阴离子和7种阳离子。考察了激发电压值、激发电压频率对检测的影响;缓冲溶液浓度及pH、进样操作对分离的影响。在最佳分离检测条件下,12种无机离子可在4min内完成测定。阳离子的检出限为0.2(Na^ )-3μmol/L(Mn^2 );阴离子的检出限为0.5(SO4^2-)-4μmol/L(Br^-);线性范围可达两个数量级。方法用于实际水样中阴离子和阳离子的测定。  相似文献   

19.
A rapid and universal capillary zone electrophoresis (CZE) method was developed to determine the dissociation constants (pK a) of the 20 standard proteogenic amino acids. Since some amino acids are poorly detected by UV, capacitively coupled contactless conductivity detection (C4D) was used as an additional detection mode. The C4D coupling proved to be very successful on a conventional CE-UV instrument, neither inducing supplementary analyses nor instrument modification. In order to reduce the analysis time for pK a determination, two strategies were applied: (i) a short-end injection to reduce the effective length, and (ii) a dynamic coating procedure to generate a large electroosmotic flow (EOF), even at pH values as low as 1.5. As a result, the analysis time per amino acid was less than 2 h, using 22 optimized buffers covering a pH range from 1.5 to 12.0 at a constant ionic strength of 50 mM. pK a values were calculated using an appropriate mathematical model describing the relationship between effective mobility and pH. The obtained pK a values were in accordance with the literature. Figure a UV (1) and C4D (2) detectors placed on-line on the CE capillary. b Curve of effective mobility as a function of pH for histidine  相似文献   

20.
An in‐house flow‐injection capillary electrophoresis with capacitively coupled contactless conductivity detection method was developed for the direct measurement of colistin in pharmaceutical samples. The flow injection and capillary electrophoresis systems are connected by an acrylic interface. Capillary electrophoresis separation is achieved within 2 min using a background electrolyte solution of 5 mM 2‐morpholinoethanesulfonic acid and 5 mM histidine (pH 6). The flow‐injection section allows for convenient filling of the capillary and sample introduction without the use of a pressure/vacuum manifold. Capacitively coupled contactless conductivity detection is employed since colistin has no chromophore but is cationic at pH 6. Calibration curve is linear from 20 to 150 mg/L, with a correlation coefficient (r2) of 0.997. The limit of quantitation is 20 mg/L. The developed method provides precision, simplicity, and short analysis time.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏