首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The transfer of the α-hydroxy-carboxylates of glycolic, lactic, mandelic and gluconic acid from the aqueous electrolyte phase into an organic 4-(3-phenylpropyl)-pyridine (PPP) phase is studied at a triple-phase boundary electrode system. The tetraphenylporphyrinato complex MnTPP dissolved in PPP is employed to drive the anion transfer reaction and naphthalene-2-boronic acid (NBA) is employed as a facilitator. In the absence of a facilitator, the ability of α-hydroxy-carboxylates to transfer into the organic phase improves, consistent with hydrophobicity considerations giving relative transfer potentials (for aqueous 0.1 M solution) of gluconate>glycolate>lactate>mandelate. In the presence of NBA, a shift of the reversible transfer potential to more negative values is indicating fast reversible binding (the mechanism for the electrode process is EICrev) and the binding constants are determined as K glycolate = 2 M−1, K mandelate = 60 M−1, K lactate = 130 M−1 and K gluconate = 2,000 M−1. The surprisingly strong interaction for gluconate is rationalised based on secondary interactions between the gluconate anion and NBA.  相似文献   

2.
A kind of erbium hexacyanoferrate (ErHCF)-modified carbon ceramic electrodes (CCEs) fabricated by mechanically attaching ErHCF samples to the surface of CCEs derived from sol–gel technique was proposed. The resulting modified electrodes exhibit well-defined redox responses with the formal potential of +0.215 V [vs saturated calomel electrode (SCE)] at a scan rate of 20 mV s−1 in 0.5 M KCl (pH 7) solution. The voltammetric characteristics of the ErHCF-modified CCEs were investigated by voltammetry. Attractively, the ErHCF-modified CCEs presented good electrocatalytic activity with a marked decrease in the overvoltage about 400 mV for l-cysteine oxidation. The calibration plot for l-cysteine determination was linear at 5.0 × 10−6–1.3 × 10−4 M with a linear regression equation of I(A) = 0.558 + 0.148c (μM) (R 2 = 0.9989, n = 20), and the detection limit was 2 × 10−6 M (S/N = 3). At last, the ErHCF-modified CCEs were used for amperometric detection of l-cysteine in real samples.  相似文献   

3.
The preparation and electrochemical characterization of a carbon nanotube paste electrode modified with 2,2′-[1,2-ethanediylbis (nitriloethylidyne)]-bis-hydroquinone, referred to as EBNBH, was investigated. The EBNBH carbon nanotube paste electrode (EBNBHCNPE) displayed one pair of reversible peaks at E pa = 0.18 V and E pc = 0.115 V vs Ag/AgCl. Half wave potential (E 1/2) and ΔE p were 0.148 and 0.065 V vs Ag/AgCl, respectively. The electrocatalytic oxidation of ascorbic acid (AA) has been studied on EBNBHCNPE, using cyclic voltammetry, differential pulse voltammetry and chronoamperometry techniques. It has been shown that the oxidation of AA occurs at a potential where oxidation is not observed at the unmodified carbon paste electrode. The heterogeneous rate constant for oxidation of AA at the EBNBHCNPE was also determined and found to be about 1.07 × 10−3 cm s−1. The diffusion coefficient of AA was also estimated as 5.66 × 10−6 cm2 s−1 for the experimental conditions, using chronoamperometry. Also, this modified electrode presented the property of electrocatalysing the oxidation of AA and uric acid (UA) at 0.18 and 0.35 V vs Ag/AgCl, respectively. The separations of anodic peak potentials of AA and UA reached 0.17 V. Using differential pulse voltammetry, the calibration curves for AA and UA were obtained over the range of 0.1–800 μM and 20–700 μM, respectively. With good selectivity and sensitivity, the present method provides a simple method for selective detection of AA and UA in biological samples.  相似文献   

4.
The voltammetric behaviour and amperometric detection of tetracycline (TC) antibiotics at multi-wall carbon nanotube modified glassy carbon electrodes (MWCNT-GCE) are reported. Cyclic voltammograms of TCs showed enhanced oxidation responses at the MWCNT-GCE with respect to the bare GCE, attributable to the increased active electrode surface area. Hydrodynamic voltammograms obtained by flow-injection with amperometric detection at the MWCNT-GCE led us to select a potential value E det = +1.20 V. The repeatability of the amperometric responses was much better than that achieved with bare GCE (RSD ranged from 7 to 12%), with RSD values for i p of around 3%, thus demonstrating the antifouling capability of MWCNT modified electrodes. An HPLC method with amperometric electrochemical detection (ED) at the MWCNT-GCE was developed for tetracycline, oxytetracycline (OTC), chlortetracycline and doxycycline (DC). A mobile phase consisting of 18:82 acetonitrile/0.05 mol L−1 phosphate buffer of pH 2.5 was selected. The limits of detection ranged from 0.09 μmol L−1 for OTC to 0.44 μmol L−1 for DC. The possibility to carry out multiresidue analysis is demonstrated. The HPLC-ED/MWCNT-GCE method was applied to the analysis of fish farm pool water and underground well water samples spiked with the four TCs at 2.0 × 10−7 mol L−1. Solid-phase extraction was accomplished for the preconcentration of the analytes and clean-up of the samples. Recoveries ranged from 87 ± 6 to 99 ± 3%. Under preconcentration conditions, limits of detection in the water samples were between 0.50 and 3.10 ng mL−1.  相似文献   

5.
Poly(vinylferrocenium) perchlorate–polyaniline (PVF+–PANI) composite film was synthesized electrochemically on Pt electrode in a methylene chloride solution containing a mixture of poly(vinylferrocene) (PVF) polymer and aniline monomer. PVF+ polymer in the composite film was used as an electron transfer mediator. The composite coating showed significant electrochemical activity towards hydroquinone (HQ) at pH 4, with high sensitivity and a wide linearity range. The interaction of HQ with PVF+ and PANI homopolymer films was investigated electrochemically and spectroscopically. HQ molecules are accumulated on the electrode surface due to trapping by both polymers in the composite film and then oxidized catalytically by PANI. The most significant contribution of PVF+ polymer is that it facilitates electron transfer in the composite film. The linear response range was found to be between 1.60 × 10−4 mM and 115 mM (R 2 = 0.999) at 0.45 V vs saturated calomel electrode. The limit of detection (LOD) was 4.94 × 10−5 mM.  相似文献   

6.
The stability of poly(N-methylaniline) (PNMA) as electrode material has been studied in aqueous solutions of sulfuric acid with the use of electrochemical and in situ Raman spectroscopic techniques. It has been shown that the electrochemical decomposition of electrodeposited PNMA films follows a first-order reaction kinetics. The decomposition rate constants vary between 1.2 × 10−5 and 2.0 × 10−3 s−1 for electrode potential varying between 0.2 and 1.0 V vs Ag/AgCl, respectively. In situ Raman spectroscopy has been applied in obtaining kinetic data at selected electrode potentials, and good correlation of these data with the corresponding data obtained by cyclic voltammetry has been found. As compared to polyaniline, the decomposition of PNMA proceeds at nearly the same rate at electrode potentials not exceeding 0.5 V. The decomposition of PNMA proceeds faster within the potential limits of 0.5 to 0.8 V and slower at electrode potentials exceeding 0.8 V as compared to polyaniline. This article is dedicated to Professor Algirdas Vaškelis (Institute of Chemistry, Vilnius, Lithuania) on the occasion of his 70th birthday and in honour of his contributions to electrochemistry and physical chemistry.  相似文献   

7.
Electrochemical study of polyaniline deposited on a titanium surface   总被引:3,自引:0,他引:3  
The electrochemical synthesis of polyaniline on a titanium surface in aqueous sulfuric acid solutions with various concentrations of added aniline has been investigated by cyclic voltammetry. By utilizing a more cathodic potential range (up to −0.6 V) for the cyclization than is usual (up to −0.2 V) on Pt and Au electrodes, the new voltammetric waves have been deconvoluted from the already well-known ones for polyaniline. By simultaneous electrochemical and in situ Raman spectroscopic measurements, the Raman bands of polyaniline electrodeposited on a Ti electrode, were assigned for potentials of −0.15 V and −0.6 V. It was found that the new monitored waves were closely related to the so-called “middle” peaks and appear only when the polyaniline reaches an overoxidized state. Received: 7 August 1997 / Accepted: 4 November 1997  相似文献   

8.
Electrochemical investigations of the reaction mechanism and kinetics between riboflavin immobilised on zirconium phosphate (ZPRib) in carbon paste and NADH showed results yielding reliable information about aspects on the mechanism of the electron transfer reaction between the flavin and NADH. The formal potential (E°′) of the adsorbed riboflavin was −220 mV versus SCE at pH 7.0. A shift about 250 mV towards a more positive potential compared with its value in solution was assigned to the interaction between the basic nitrogen of riboflavin and the acid groups of ZP. The invariance of the E°′ with the pH of the contacting solution and the effect of different buffer constituents were attributed to the protection effect of ZP over the riboflavin. The electrocatalytic oxidation of NADH at the electrode was investigated using cyclic voltammetry and rotating disk electrode methodology using a potential of −50 mV versus SCE. The heterogeneous electron transfer rate constant, k obs, was 816 M−1 s−1 and the Michaelis-Menten constant, K M, was 1.8 mM (confirming a charge transfer complex intermediate in the reaction) for an electrode with a riboflavin coverage of 6.8 × 10−10 mol cm−2. This drastic increase in the reaction rate between NADH and the immobilised riboflavin was assigned to the shift of the E°′. A surprising effect with addition of calcium or magnesium ion to the solution was also observed. The E°′ was shifted to −150 mV versus SCE and the reaction rate for NADH oxidation increased drastically. Received: 22 February 1999 / Accepted: 10 March 1999  相似文献   

9.
Bulk screen-printed electrodes (bSPEs) modified with zirconium phosphate (ZrP) and Meldola blue (MB) and by electrochemical deposition of a Reineckate film (bMBZrPRs-SPEs) have been constructed and used as NADH sensors. Cyclic voltammetric investigation of these bulk electrochemically modified screen-printed electrodes revealed stable catalytic activity in oxidation of the reduced form of the coenzyme nicotinamide adenine dinucleotide (NADH). Flow-injection analysis (FIA) coupled with amperometric detection confirmed the improved stability of the bMBZrPRs-SPEs (10−4 mol L−1 NADH, %RSD = 4.2, n = 90, pH 7.0). Other conditions, for example applied working potential (+50 mV relative to Ag|AgCl), flow rate (0.30 mL min−1) and pH-dependence (range 4.0–10.0) were evaluated and optimized. A glycerol biosensor, prepared by immobilizing glycerol dehydrogenase (GDH) on the working electrode area of a bMBZrPRs-SPE, was also assembled. The biosensor was most stable at pH 8.5 (%RSD = 5.6, n = 70, 0.25 mmol L−1 glycerol). The detection and quantification limits were 2.8 × 10−6 and 9.4 × 10−6 mol L−1, respectively, and the linear working range was between 1.0 × 10−5 and 1.0 × 10−4 mol L−1. To assess the effect of interferences, and recovery by the probe we analyzed samples taken during fermentation of chemically defined grape juice medium and compared the results with those obtained by HPLC.  相似文献   

10.
The electrocatalytic oxidation of aspirin and acetaminophen on nanoparticles of cobalt hydroxide electrodeposited on the surface of a glassy carbon electrode in alkaline solution was investigated. The process of oxidation and the kinetics have been investigated using cyclic voltammetry, chronoamperometry, and steady-state polarization measurements. Voltammetric studies have indicated that in the presence of drugs, the anodic peak current of low valence cobalt species increases, followed by a decrease in the corresponding cathodic current. This indicates that drugs are oxidized on the redox mediator which is immobilized on the electrode surface via an electrocatalytic mechanism. With the use of Laviron’s equation, the values of anodic and cathodic electron-transfer coefficients and charge-transfer rate constant for the immobilized redox species were determined as α s,a = 0.72, α s,c = 0.30, and k s = 0.22 s−1. The rate constant, the electron transfer coefficient, and the diffusion coefficient involved in the electrocatalytic oxidation of drugs were reported. It was shown that by using the modified electrode, aspirin and acetaminophen can be determined by amperometric technique with detection limits of 1.88 × 10−6 and 1.83 × 10−6 M, respectively. By analyzing the content of acetaminophen and aspirin in bulk forms using chronoamperometric and amperometric techniques, the analytical utility of the modified electrode was achieved. The method was also proven to be valid for analyzing these drugs in urine samples.  相似文献   

11.
The development of Cu(II) solid-contact ion-selective electrodes, based on 1,2-di-(o-salicylaldiminophenylthio)ethane as a neutral carrier, is presented. For the electrodes construction, unmodified carbon ink (type 1 electrode) and polymer membrane-modified carbon ink (type 2 electrode) were used as solid support and transducer layer. Also, carbon ink composite polymer membrane electrode (type 3 electrode) was prepared. The analytical performance of the electrodes was evaluated with potentiometry, while bulk and interfacial electrode features were provided with electrochemical impedance spectroscopy. It is shown that modification of carbon ink with polymer membrane cocktail decreases the bulk contact resistance of the transducer layer and polymer membrane, thus enhancing the analytical performance of the electrode in terms of sensitivity, linear range, and stability of potential. The optimized electrodes of types 2 and 3 exhibit a wide linear range with detection limits of 1.8 × 10−6 and 1.6 × 10−6 M, respectively. They are suitable for determination of Cu2+ in analytical measurements by direct potentiometry and in potentiometric titrations, within pH between 2.3 and 6.5. The electrodes are selective for Cu2+ over a large number of tested transition and heavy metal ions.  相似文献   

12.
The electrochemical solid phase micro-extraction of salicylic acid (SA) at graphite-epoxy-composed solid electrode surface was studied by cyclic voltammetry. SA was oxidized electrochemically in pH 12.0 aqueous solution at 0.70 V (vs. saturated calomel electrode) for 7 s. The oxidized product shows two surface-controlled reversible redox couples with two proton transferred in the pH range of 1.0∼6.0 and one proton transferred in the pH range of 10.0∼13.0 and is extracted on the electrode surface with a kinetic Boltzman function of i p = 3.473–4.499/[1 + e(t − 7.332)/6.123] (χ 2 = 0.00285 μA). The anodic peak current of the extracted specie in differential pulse voltammograms is proportional to the concentration of SA with regression equation of i p = −5.913 + 0.4843 c (R = 0.995, SD = 1.6 μA) in the range of 5.00∼200 μM. The detection limit is 5.00 μM with RSD of 1.59% at 60 μM. The method is sensitive and convenient and was applied to the detection of SA in mouse blood samples with satisfactory results.  相似文献   

13.
Synthesis, characterization and thermal analysis of polyaniline (PANI)/ZrO2 composite and PANI was reported in our early work. In this present, the kinetic analysis of decomposition process for these two materials was performed under non-isothermal conditions. The activation energies were calculated through Friedman and Ozawa-Flynn-Wall methods, and the possible kinetic model functions have been estimated through the multiple linear regression method. The results show that the kinetic models for the decomposition process of PANI/ZrO2 composite and PANI are all D3, and the corresponding function is ƒ(α)=1.5(1−α)2/3[1−(1-α)1/3]−1. The correlated kinetic parameters are E a=112.7±9.2 kJ mol−1, lnA=13.9 and E a=81.8±5.6 kJ mol−1, lnA=8.8 for PANI/ZrO2 composite and PANI, respectively.  相似文献   

14.
Adsorption of iodide ions at the Bi(111) and Cd(0001) electrodes from the aqueous solutions with constant ionic strength 0.1x M KI + 0.1(1−x) M KF and 0.1x M KI + 0.033(1−x) M K2SO4 has been studied by impedance spectroscopy. It was found that, to a first approximation, the classical Frumkin–Melik–Gaikazyan equivalent circuit with the slow diffusion-like and adsorption steps can be applied for fitting the experimental impedance data for iodide ions adsorption on Bi(111) and Cd(0001) from aqueous solutions with constant ionic strength. The modified Grafov–Damaskin circuit can be used in the region of electrode potentials, where parallel faradic processes (electroreduction of protons, oxygen traces) are probable. The more complicated Ershler equivalent circuit, taking into account the slow diffusion-like, adsorption and charge transfer steps, is not applicable for characterization of the adsorption process of I at Bi(111) and Cd(0001) electrodes.  相似文献   

15.
Measurements of the electrophoretic mobility (u E) of particles of colloidal α-alumina were made as a function of pH, electrolyte concentration and electrolyte type (NaCl, NaNO3 and KCl) using two similar instrumental techniques. Significant differences (50% or less) in the values of u E of particles in NaCl were obtained from the two instruments; however, the isoelectric points (IEPs) (the pH at which u E=0), estimated from the two sets of measurements, occurred at 7.5 ± 0.3 and 7.8 ± 0.05 and were not significantly different. The latter estimate corresponds with those for particles in KCl and NaNO3 of 8.05 ± 0.11 and 7.95 ± 0.18, respectively, made using the same instrument and indicate that the IEP was a weak function of electrolyte type. When cations acted as counterions (pH > IEP), the absolute magnitudes and the ranges of u E with electrolyte concentration were found to be significantly less than when anions acted as counterions (IEP > pH). Estimates of the zeta potential (ζ), made using various procedures, showed variations of up to 25% at low ratios of electrical-double-layer thickness (κ −1) to particle radius (a) (κa∼10) and were of a similar scale to differences in u E, but no significant variations (95% confidence) in ζ were obtained at high values (κa∼200). Received: 12 July 2000 Accepted: 17 October 2000  相似文献   

16.
A method to fabricate poly(3,4-ethylene dioxythiophene)-poly(4-styrene sulfonate)-Meldola Blue (PEDOT-PSS-MDB)-modified electrodes had been disclosed. Firstly, the PEDOT-PSS-film-modified electrode was electrochemically prepared. Then, the PEDOT-PSS was treated as a matrix to immobilize electroactive mediator, Meldola Blue (MDB), by means of an electrostatic interaction to form the proposed film, PEDOT-PSS-MDB. Electrochemical properties of the proposed film exhibited surface confinement and pH dependence. The PEDOT-PSS-MDB electrode could electrocatalytically reduce hydrogen peroxide (H2O2) with a low overpotential and showed a linear response to H2O2 in the concentration range of 5 to 120 μM, detection limit of 0.1 μM, and sensitivity of 353.9 μA mM−1 cm−2 (S/N = 3). By comparison, the electrocatalytic activity of PEDOT-PSS-MDB electrode was found superior to that of PEDOT-PSS and MDB-PSS electrodes. It also has competitive potential as compared with other mediators, through the use of HRP to determine H2O2. Moreover, the potential interferents such as ascorbic acid, dopamine, uric acid, and glucose were also studied for H2O2 determination by the proposed film.  相似文献   

17.
Newly developed, simple, low-cost and sensitive ion-selective electrodes have been proposed for determination of some antiepileptic drugs such as lamotrigine, felbamate, and primidone in their pharmaceutical preparations as well as in biological fluids. The electrodes are based on poly(vinyl chloride) membranes doped with drug–tetraphenyl borate (TPB) or drug–phosphotungstic acid (PT) ion-pair complexes as molecular recognition materials. The novel electrodes displayed rapid Nernstian responses with detection limits of approximately 10−7 M. Calibration graphs were linear over the ranges 5.2 × 10−7–1.0 × 10−3, 1.5 × 10−6–1.0 × 10−3, and 2.6 × 10−7–1.0 × 10−3 M for drug–TPB and 5.8 × 10−7–1.0 × 10−3, 1.8 × 10−7–1.0 × 10−3, and 6.6 × 10−7–1.0 × 10−3 M for drug–PT electrodes, respectively, with slopes ranging from 52.3 to 62.3 mV/decade. The membranes developed have potential stability for up to 1 month and proved to be highly selective for the drugs investigated over other ions and excipients. The results show that the selectivity of the ion-selective electrodes is influenced significantly by the plasticizer. The proposed electrodes were successfully applied in the determination of these drugs in pharmaceutical preparations in four batches of different expiry dates. Statistical Student’s t test and F test showed insignificant systematic error between the ion-selective electrode methods developed and a standard method. Comparison of the results obtained using the proposed electrodes with those found using a reference method showed that the ion-selective electrode technique is sensitive, reliable, and can be used with very good accuracy and high percentage recovery without pretreatment procedures of the samples to minimize interfering matrix effects. Figure Structure of lamotrigine, felbanate and primidone  相似文献   

18.
The simultaneous determination of three isomers of phenylenediamines (o, m, and p-phenylenediamine) and two isomers of dihydroxybenzenes (catechol and resorcinol) in hair dyes was performed by capillary zone electrophoresis coupled with amperometric detection (CZE–AD). The effects of working electrode potential, pH and concentration of running buffer, separation voltage, and injection time on CZE–AD were investigated. Under the optimum conditions the five analytes could be perfectly separated in 0.30 mol L−1 borate–0.40 mol L−1 phosphate buffer (pH 5.8) within 15 min. A 300 μm diameter platinum electrode had good responses at +0.85 V (versus SCE) for the five analytes. Their linear ranges were from 1.0 × 10−6 to 1.0 × 10−4 mol L−1 and the detection limits were as low as 10−7 mol L−1 (S/N = 3). This working electrode was successfully used to analyze eight kinds of hair dye sample with recoveries in the range 91.0–108.0% and RSDs less than 5.0%. These results demonstrated that capillary zone electrophoresis coupled with electrochemical detection using a platinum working electrode as detector was convenient, highly sensitive, highly repeatable and could be used in the rapid determination of practical samples. Figure Electropherograms obtained from 10 mg mL−1 hair dye sample solutions at a platinum working electrode under optimum CZE–AD conditions: (a) natural black (I), (b) golden: (1) p-phenylenediamine, (2) m-phenylenediamine, (3) o-phenylenediamine, (4) resorcinol, and (5) catechol  相似文献   

19.
The potential application of ordered mesoporous carbon (OMC)-modified glassy carbon electrode (OMC/GCE) in electrochemistry as a novel electrode material was investigated. X-ray diffraction, transmission electron micrographs, and cyclic voltammetry were used to characterize the structure and electrochemical behaviors of this material. Compared to GC electrode, the peak currents of potassium ferricyanide (K3[Fe(CN)6]) increase and the peak potential separation (ΔE p) decreases at the OMC/GC electrode. These phenomena suggest that OMC-modified GC electrode possesses larger electrode area and faster electron transfer rate, as compared with bare GC electrode. Furthermore, riboflavin was detected using OMC/GC electrode in aqueous solutions. The results showed that, under an optimum condition (pH 7.0), the OMC/GC electrode exhibited excellent response performance to riboflavin in the concentration range of 4.0 × 10−7 to 1.0 × 10−6 M with a high sensitivity of 769 μA mM−1. The detection limit was down to around 2 × 10−8 M. With good stability and reproducibility, the present OMC/GC electrode was applied in the determination of vitamin B2 content in vitamin tablets, and satisfactory results were obtained.  相似文献   

20.
Acetylene insertion into Pt(II)–H and Pt(II)SiH3 bonds of PtH(SiH3)(PH3) was investigated using ab initio molecular orbital and M?ller-Plesset perturbation theory methods. The insertion into PtH was predicted to proceed with a smaller activation energy (E a =12.8 kcal/mol) than that into PtSiH3 (E a =20.9 kcal/mol). The reaction energy (ΔE) of the insertion into PtH is 10 kcal/mol smaller than that for the insertion into PtSiH3, which reflects differences in bond energies between CH and CSi and between PtH and PtSiH3. A comparison with ethylene insertion revealed that the acetylene insertion occurs more easily, and the latter reaction is more exothermic. A simple vibronic coupling model combined with Toyozawa's interaction mode analysis was used to examine interesting differences in E a and ΔE between insertions into PtH and PtSiH3, and between acetylene and ethylene insertions. This analysis suggests that the factors determining E a are the stiffness of the PtH and PtSiH3 bonds and the vibronic coupling strength of acetylene and ethylene. Received: 13 August 1998 / Accepted: 2 September 1998 / Published online: 15 February 1999  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号