首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 546 毫秒
1.
Reversed-phase microbore high-performance liquid chromatography was investigated for high-sensitivity analysis of phenylthiohydantoin (PTH) amino acids. A mixed nitrile alkylsilane bonded phase was developed and ternary gradient elution conditions were devised for resolution of the common PTH amino acids. Elution conditions were developed with a conventional 150 X 4.6 mm I.D. column and transferred to a 150 X 1 mm I.D. microbore column. The performance of these columns was evaluated in terms of PTH amino acid resolution, enhanced sample detectability, and retention time precision. For this work a general purpose high-performance liquid chromatograph was modified to reduce extra column band broadening and a preformed gradient elution technique was developed to achieve rapid analysis times at microbore flow-rates. The microbore high-performance liquid chromatographic system is useful for high-sensitivity analysis of PTH amino acids in micro-sequencing applications.  相似文献   

2.
The present study examines the effect of reversed-phase high-performance liquid chromatography (RP-HPLC) column diameter (1mm to 9.4mm I.D.) on the one-step slow gradient preparative purification of a 26-residue synthetic antimicrobial peptide. When taken together, the semi-preparative column (9.4mm I.D.) provided the highest yields of purified product (an average of 90.7% recovery from hydrophilic and hydrophobic impurities) over a wide range of sample load (0.75-200mg). Columns with smaller diameters, such as narrowbore columns (150x2.1mm I.D.) and microbore columns (150x1.0mm I.D.), can be employed to purify peptides with reasonable recovery of purified product but the range of the crude peptide that can be applied to the column is limited. In addition, the smaller diameter columns require more extensive fraction analysis to locate the fractions of pure product than the larger diameter column with the same load. Our results show the excellent potential of the one-step slow gradient preparative protocol as a universal method for purification of synthetic peptides.  相似文献   

3.
A high-performance liquid chromatographic method for the analysis of coenzyme A thioesters which employs continuous-flow fast atom bombardment mass spectrometric detection is presented. The chromatographic system utilizes gradient elution with reversed-phase conditions using ammonium acetate-acetonitrile from both standard analytical (3.9 mm I.D.) and microbore (1 mm I.D.) columns. Applications to coenzyme A thioesters of various acyl group chain length (C2-C18) and functionality (-COOH, -OH, -C = C-) are described. The system is also applied to an in vitro enzyme reaction (crotonase) to directly follow the disappearance of substrate and appearance of product. The mass spectrometry of coenzyme A thioesters, their chromatographic behavior, system stability, and sensitivity of detection are discussed.  相似文献   

4.
The application of microbore systems (15 cm X 1 mm I.D. columns filled with Nucleosil C18, 5 microns particle size) to the determination of cephalexin and cadralazine in plasma was investigated. Factors such as mobile phase flow-rate, detector flow-cell volume and injection volume were examined with regard to the needs of routine drug analysis. Mobile phase flow-rates of 50-60 microliters/min were used. A flow cell with an optical path length of 6 mm and an intermediary volume (2.4 microliters) was selected for UV detection in order to obtain sufficient sensitivity. Large volumes of non-eluting solvent containing the drug were injected on the column. The addition of an ion-pairing reagent to samples containing cephalexin and cefroxadin prior to the injection was found to improve the chromatographic performance. The blood sample size required for analysis with microbore columns was smaller than that with conventional columns. The analysis time was similar and the limit of quantitation was also similar, provided that large sample volumes were injected on the microbore column.  相似文献   

5.
Novel monolithic supports (MS/BVPE) were prepared by thermally initiated free radical copolymerisation of p-methylstyrene (MS) and 1,2-bis(p-vinylphenyl)ethane (BVPE). The polymer was synthesised in fused silica capillaries (80 mm x 0.2 mm and 80 mm x 0.53 mm) and in borosilicate glass columns (90 mm x 1.0 mm and 90 mm x 3.0 mm) to yield different HPLC column designs. A comparison of those column dimensions regarding morphology as well as separation efficiency and applicability in bioanalysis is presented. The efficiency towards proteins as well as oligonucleotides was found to be considerably improved with decreasing column I.D. While a 5-protein mixture was baseline separated on all investigated column designs, the separation of small biomolecules like oligonucleotides or peptides on microbore and conventional size glass columns was strongly restricted in terms of resolution due to extensive peak broadening or the occurrence of peak asymmetry. Monolithic MS/BVPE capillary columns up to 0.53 mm I.D., however, proved to be applicable to the fractionation of the whole spectrum of biopolymers, including proteins, peptides, oligonucleotides as well as double-stranded DNA fragments. Due to the fact that reliable chromatography makes great demand on the robustness of the stationary phase, monolithic MS/BVPE capillaries were subjected to a comprehensive reproducibility study including run-to-run as well as batch-to-batch reproducibility.  相似文献   

6.
Reversed-phase ultra-performance liquid chromatography was used for biopolymer separations in isocratic and gradient mode. The gradient elution mode was employed to estimate the optimal mobile phase flow rate to obtain the best column efficiency and the peak capacity for three classes of analytes: peptides, oligonucleotides and proteins. The results indicate that the flow rate of the Van Deemter optimum for 2.1 mm I.D. columns packed with a porous 1.7 microm C18 sorbent is below 0.2 mL/min for our analytes. However, the maximum peak capacity is achieved at flow rates between 0.15 and 1.0 mL/min, depending on the molecular weight of the analyte. The isocratic separation mode was utilized to measure the dependence of the retention factor on the mobile phase composition. Constants derived from isocratic experiments were utilized in a mathematical model based on gradient theory. Column peak capacity was predicted as a function of flow rate, gradient slope and column length. Predicted peak capacity trends were compared to experimental results.  相似文献   

7.
Knowing the adsorption isotherms of the components of a mixture on the chromatographic system used to separate them is necessary for a better understanding of the separation process and for the optimization of the production rate and costs in preparative high-performance liquid chromatography (HPLC). Currently, adsorption isotherms are usually measured by frontal analysis, using conventional analytical columns. Unfortunately, this approach requires relatively large quantities of pure compounds, and hence is expensive, especially in the case of pure enantiomers. In this work, we investigated the possible use of packed micro-bore and capillary HPLC columns for the determination of adsorption isotherms of benzophenone, o-cresol and phenol in reversed-phase systems and of the enantiomers of mandelic acid on a Teicoplanin chiral stationary phase. We found a reasonable agreement between the isotherm coefficients of the model compounds determined on micro-columns and on conventional analytical columns packed with the same material. Both frontal analysis and perturbation techniques could be used for this determination. The consumption of pure compounds needed to determine the isotherms decreases proportionally to the second power of the decrease in the column inner diameter, i.e. 10 times for a micro-bore column (1 mm I.D.) and 100 times for capillary columns (0.32 mm I.D.) with respect to 3.3 mm I.D. conventional columns.  相似文献   

8.
Four cephalosporins, cefazolin, ceftizoxime, cefaloridine and cefaclor, were determined using a novel microbore high-performance liquid chromatographic system designed to be entirely compatible with direct liquid interfacing (DLI) for mass spectrometric analysis. The chromatographic support was a 5-micron C18 column of 0.3 mm I.D., compared with the usual microbore column diameters of 1-2 mm. The mobile phase contained no buffers or salts which may have caused column blocking or mobile phase crystallization, and the use of a concentration column allowed the injection of large volumes of analyte (up to 500 microliters). The assay was reproducible, the relative standard deviations being less than 20% within-day and between-day for all the drugs. The detection limit for cefaloridine and cefazolin was 1 ng and for cefaclor and ceftizoxime 5 ng.  相似文献   

9.
A comprehensive two-dimensional liquid chromatographic system (2D SCX/RP) is con- structed with a 10-port-2-way valve using strong cation exchange chromatography (Hypersil SCX, 100 mm×4.6 mm I.D.) followed by reversed phase chromatography (Hypersil BDS C18, 15 mm×4.6 mm I.D.) to separate the complex peptides from globin peptic hydrolysate. After the sample was loaded on the SCX column, the phosphate buffer (pH 4.0) was used to elute the peptides. Then, elutes flowed through the interface and the peptides focused on the head of the trapping columns (Hypersil BDS C18, 15 mm×4.6 mm I.D.) but salt passed into the waste. After the valve was switched, the samples were flushed with a backward flow into the RP analytical column. The peptides on the SCX were eluted with 12 discontinuous steps linearly increasing salt concentrations. The peptides enriched on the trapping column were desalted and separated by the RP columns. The resolution and the resolved peaks of the 2D SCX/RP system were greatly increased and the total peak capacity reached as high as 2280.  相似文献   

10.
In the present work, a 2-D capillary liquid chromatography method for fractionation and separation of human salivary proteins is demonstrated. Fractionation of proteins according to their pI values was performed in the 1-D employing a strong anion exchange (SAX) column subjected to a wide-range descending pH gradient. Polystyrene-divinylbenzene (PS-DVB) RP columns were used for focusing and subsequent separation of the proteins in the 2-D. The SAX column was presaturated with a high pH buffer (A) consisting of 10 mM amine buffering species, pH 9.0, and elution was performed with a low pH elution buffer (B) having the same buffer composition and concentration as buffer A, but pH 3.5. Isoelectric point fractions eluting from the 1-D column were trapped on PS-DVB trap columns prior to back-flushed elution onto the PS-DVB analytical column for separation of the proteins. The 1-D fraction eluting at pH 9.0-8.7 was chosen for further analysis. After separation on the RP analytical column, nine RP protein fractions were collected and tryptic digested for subsequent analyses by MALDI TOF MS and column switching capillary LC coupled to ESI TOF MS and ESI QTOF MS. Eight proteins and two peptides were identified in the pH 9.0-8.7 fraction using peptide mass fingerprinting and uninterpreted MS/MS data.  相似文献   

11.
Monolithic silica capillary columns were successfully prepared in a fused silica capillary of 530 microm inner diameter and evaluated in HPLC after octadecylsilylation (ODS). Their efficiency and permeability were compared with those of columns pakked with 5-microm and 3-microm ODS-silica particles. The monolithic silica columns having different domain sizes (combined size of through-pore and skeleton) showed 2.5-4.0-times higher permeability (K= 5.2-8.4 x 10(-14) m2) than capillary columns packed with 3-mm particles, while giving similar column efficiency. The monolithic silica capillary columns gave a plate height of about 11-13 microm, or 11 200-13 400 theoretical plates/150 mm column length, in 80% methanol at a linear mobile phase velocity of 1.0 mm/s. The monolithic column having a smaller domain size showed higher column efficiency and higher pressure drop, although the monolithic column with a larger domain size showed better overall column performance, or smaller separation impedance (E value). The larger-diameter (530 microm id) monolithic silica capillary column afforded a good peak shape in gradient elution of proteins at a flow rate of up to 100 microL/min and an injection volume of up to 10 microL.  相似文献   

12.
在蛋白质组学研究中,多肽混合物的有效分离对蛋白质鉴定和蛋白质之间相互作用的研究起着决定性的影响。基于此,用反相液相色谱研究了在两个不同长度的色谱柱上分离多肽混合物时色谱柱长度与峰容量的关系,同时考察了梯度洗脱时间对峰容量和峰宽的影响。实验结果表明,色谱柱长度对峰容量有显著的影响,而延长梯度洗脱时间不仅可以增加峰容量,而且可以增加峰宽。这说明用毛细管液相色谱 串联质谱联用方法对多肽混合物进行分离鉴定时,采用较长的色谱柱和较长的梯度洗脱时间有利于对更多的多肽进行分析鉴定。  相似文献   

13.
The quantitative determination of triacylglycerols separated according to acyl carbon numbers and level of unsaturation was studied on two 10-m immobilised SE-54 columns. The fat samples were silylated before on-column injection. The 0.2 mm I.D. column showed higher resolving power and the 0.32 mm I.D. column better repeatability. The application to real quantitations was investigated with analyses of butter-fat solid and liquid fractions and of untreated and interesterified 70-30 mixtures of butter-fat solid fraction and hydrogenated rapeseed oil. Changes in the triacylglycerol composition induced by interesterification and fractionation are so pronounced that analysis on capillary columns can be recommended, in spite of only fair repeatability.  相似文献   

14.
Low-capacity anion-exchange resin was packed into a 45 cm X 0.19 mm I.D. fused-silica tubing and applied to micro-column liquid chromatography of nucleobases, nucleosides and isomers of nucleotides. The effects of the chromatographic conditions on the elution behaviour of these compounds were studied. The efficiency of the microbore packed column was comparable with that of the conventional size column.  相似文献   

15.
This study records a novel application of methacrylate-based monolithic columns for MALDI-TOF/TOF MS analyses in proteomics for pre-concentration and separation of peptides derived from protein digestion. Reversed-phase monolithic capillary columns (30 mm × 0.32 mm i.d.) were created inside the fused silica capillary via thermal-initiated free-radical polymerization of ethylene glycol dimethacrylate and lauryl methacrylate monomers in the presence of 1-propanol and 1,4-butandiol as a porogen system. The elution of peptides was achieved using a linear gradient of acetonitrile from 0 to 60% in water with 0.1% trifluoroacetic acid formed in a microsyringe. Individual fractions of separated peptides were collected on the MALDI target spots covered with alpha-cyano-4-hydroxycinnamic acid used as a matrix and then they were analyzed using MALDI-TOF/TOF mass spectrometry. The developed method was tested with a mixture of tryptic peptides from bovine serum albumin and its applicability was also tested for tryptic in-gel digests from barley grain extracts of water soluble proteins separated using SDS gel electrophoresis. The number of detected peptides was approximately three to four times higher compared to the analysis without previous separation. These results show an improved quality of sample information with the higher amount of identified peptides which increased protein sequence coverage and improved sensitivity of mass spectrometry measurements.  相似文献   

16.
Monolithic columns based on poly-(styrene-divinylbenzene) (PS-DVB) were utilized both for preconcentration (in 10 mm x 0.20 mm I.D. format) and analytical separation (in 60 mm x 0.20 and 0.10 mm I.D. format) of peptides and proteins in column switching micro-scale high-performance liquid chromatography. A special holder for short monolithic preconcentration columns was designed and pressure durability tests approved long-term stability up to 400 bar. An 11-20% decrease in the average peak widths of nine peptides was obtained upon combining a preconcentration column with an analytical column as compared with a setup using an analytical column only. Trapping efficiency, especially for small and hydrophilic peptides, was optimized by using 0.10% heptafluorobutyric acid instead of 0.050% trifluoroacetic acid as solvent additive during sample loading. Using a 10 mm x 0.20 mm I.D. preconcentration column, loadabilities between 0.5 and 1.6 microg were determined by frontal analysis of proteins and bioactive peptides, respectively. A 100-fold concentration followed by direct on-line intact mass determination is demonstrated for diluted (3 micromolL(-1)) protein solutions. The applicability of the monolithic preconcentration column for multidimensional chromatography was tested by off-line two-dimensional separation, combining strong cation-exchange chromatography and ion-pair reversed-phase chromatography. Peptide identification data from digested protein mixtures demonstrated reproducibilities of 46-75% in triplicate analyses, and confident peptide identifications of low abundant peptides even in the presence of a 650-fold molar excess of high abundant peptides.  相似文献   

17.
In this work, monolithic silica columns with the C4, C8, and C18 chemistry and having various macropore diameters and two different mesopore diameters are studied to access the differences in the column efficiency under isocratic elution conditions and the resolution of selected peptide pairs under reversed-phase gradient elution conditions for the separation of peptides and proteins. The columns with the pore structural characteristics that provided the most efficient separations are then employed to optimize the conditions of a gradient separation of a model mixture of peptides and proteins based on surface chemistry, gradient time, volumetric flow rate, and acetonitrile concentration. Both the mesopore and macropore diameters of the monolithic column are decisive for the column efficiency. As the diameter of the through-pores decreases, the column efficiency increases. The large set of mesopores studied with a nominal diameter of approximately 25 nm provided the most efficient column performance. The efficiency of the monolithic silica columns increase with decreasing n-alkyl chain length in the sequence of C18相似文献   

18.
Monolithic silica capillary columns for hydrophilic interaction liquid chromatography (HILIC) were prepared by on-column polymerization of acrylic acid on monolithic silica in a fused silica capillary modified with anchor groups. The products maintained the high permeability (K=5 x 10(-14)m(2)) and provided a plate height (H) of less than 10 microm at optimum linear velocity (u) and H below 20 microm at u=6mm/s for polar solutes including nucleosides and carbohydrates. The HILIC mode monolithic silica capillary column was able to produce 10000 theoretical plates (N) with column dead time (t(0)) of 20s at a pressure drop of 20 MPa or lower. The total performance was much higher than conventional particle-packed HILIC columns currently available. The gradient separations of peptides by a capillary LC-electrospray mass spectrometry system resulted in very different retention selectivity between reversed-phase mode separations and the HILIC mode separations with a peak capacity of ca. 100 in a 10 min gradient time in either mode. The high performance observed with the monolithic silica capillary column modified with poly(acrylic acid) suggests that the HILIC mode can be an alternative to the reversed-phase mode for a wide range of compounds, especially for those of high polarity in isocratic as well as gradient elution.  相似文献   

19.
A method based on liquid chromatography coupled to mass spectrometry with positive electrospray ionisation was developed for the analysis of cyanobacterial hepatotoxins in environmental samples. The chromatographic separation was performed using two microbore columns, 2 mm and 1 mm I.D. columns, which allowed the coupling of liquid chromatography to mass spectrometry with no flow splitting. Analytes were eluted using two different water-acetonitrile, both acidified with formic acid gradients. Mass spectrometric parameters were optimised in order to maximise sensitivity. Detection limits for the 2 mm I.D. column ranged from 0.077 to 2.057 ng in full scan and from 0.021 to 1.153 ng in SIM mode. However, limits of detection as low as 60-340 pg in full scan and 6-72 pg in SIM mode were achieved for the 1 mm I.D. column. Finally, the proposed method was applied to the analysis of microcystins and nodularins in real samples.  相似文献   

20.
In the present work, an orthogonal two-dimensional (2D) capillary liquid chromatography (LC) method for fractionation and separation of proteins using wide range pH gradient ion exchange chromatography (IEC) in the first dimension and reversed phase (RP) in the second dimension, is demonstrated. In the first dimension a strong anion exchange (SAX) column subjected to a wide range (10.5-3.5) descending pH gradient was employed, while in the second dimension, a large pore (4,000 A) polystyrene-divinylbenzene (PS-DVB) RP analytical column was used for separation of the protein pH-fractions from the first dimension. The separation power of the off-line 2D method was demonstrated by fractionation and separation of human plasma proteins. Seventeen pH-fractions were manually collected and immediately separated in the second dimension using a column switching capillary RP-LC system. Totally, more than 200 protein peaks were observed in the RP chromatograms of the pH-fractions. On-line 2D analysis was performed for fractionation and separation of ten standard proteins. Two pH-fractions (basic and acidic) from the first dimension were trapped on PS-DVB RP trap columns prior to back-flushed elution onto the analytical RP column for fast separation of the proteins with UV/MS detection.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号