首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Youyou Yang  Chenchen Li  Ning Li  Huwei Liu 《Talanta》2010,82(5):1797-6510
In this paper, a micellar electrokinetic chromatography (MEKC) method combined with cation-selective exhaustive injection (CSEI) and sweeping was developed to separate and concentrate four tobacco-specific N-nitrosamines (TSNAs) including N′-nitrosoanabasine (NAB), 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK), 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol (NNAL) and 4-(methylnitrosamino)-4-(3-pyridyl)-1-butanol (iso-NNAL). Experimental parameters affecting separation efficiency and enhancement factors were investigated in detail. Under the optimum MEKC condition, NAB, NNK, NNAL and iso-NNAL were baseline separated with high separation efficiencies and good peak shapes. Furthermore, with the preconcentration by CSEI-sweeping-MEKC, the sensitivity enhancement factors for NAB, NNK, NNAL and iso-NNAL in terms of peak areas ranged from 6.0 × 103 to 1.5 × 104, and the detection limits (LOD, S/N = 3) of four TSNAs were in the range of 0.004-0.016 μg/mL. In addition, this method had fairly good repeatability, and the RSDs of retention time and peak area were less than 1% and 5%, respectively. Finally, this method showed promising capabilities in the application of detecting and analyzing TSNAs in human urine samples.  相似文献   

2.
A sensitive method for the determination of ephedrine and codeine in human urine by capillary electrophoresis(CE)was described.In order to improve the sensitivity,two online concentration techniques including cation-selective exhaustive injection (CSEI)and sweeping micellar electrokinetic chromatography(sweeping-MEKC)were used.Under the optimum conditions,the detection limits(S/N=3)were 0.10μg/L for ephedrine and 0.80μg/L for codeine.This method was successfully applied to real urine sample analysis.  相似文献   

3.
In this study, we described a high‐sensitive on‐line preconcentration method for cypromazine (CYP) and melamine (MEL) analysis using cation‐selective exhaustive injection (CSEI) combined with sweeping‐MEKC. The optimum conditions of on‐line concentration and separation were discussed. The BGE contained 100 mM SDS, 50 mM phosphoric acid (pH=2.0) and 15% acetonitrile (v/v). The sample was injected at 10 kV for 600 s, separated at ?20 kV, and detected at 210 nm. The sensitivity enhancements were 6222 for CYP and 9179 for MEL. The linear dynamic ranges were 0.4?25 ng/mL for CYP (r=0.9995) and 0.2?12 ng/mL for MEL (r=0.9991). The LODs (signal‐to‐noise ratio, 3) were 43.7 and 23.4 pg/mL for CYP and MEL, respectively. The proposed method was applied to analyze CYP and MEL in dairy products pretreated using off‐line SPE to minimize the influence of the matrix. The recoveries of CYP and MEL were satisfactory (ca. 74–83%). The experimental results suggest that the CSEI‐sweeping‐MEKC method is feasible for the application to simultaneously detect trace levels of CYP and its metabolite MEL in real milk samples.  相似文献   

4.
A novel and simple method that combines an online concentration technique with an enantioseparation technique for capillary electrophoresis—namely, cation‐selective exhaustive injection and sweeping cyclodextrin‐modified micellar electrokinetic chromatography (CSEI‐sweeping CD‐modified MEKC)—realizes the effective enantioseparation of cationic analytes while keeping a significant increase of detection sensitivity. This technique consists of a slight modification of the basic CSEI‐sweeping MEKC. The main idea is to simply add an anionic CD as a chiral selector into the micellar buffer including sodium dodecyl sulfate, but not to change any other buffers in order to preserve the online concentration mechanism. When applied to analysis of the street drug, methamphetamine, the method achieved not only a baseline enantioseparation but also limits of detection (LODs; S/N = 3) of 70–90 pg/mL (ppt) for each isomer. This translates to a more than 10 000‐fold improvement compared to the LODs by the usual injection method. The present technique, which was made from a slight modification of CSEI‐sweeping MEKC, would give an attractive approach that is applicable to almost any analytes for which CSEI‐sweeping MEKC is applicable; all that is required is the selection of an appropriate anionic CD to be added to the micellar buffer.  相似文献   

5.
Huang HY  Lien WC  Huang IY 《Electrophoresis》2006,27(16):3202-3209
In this study, anion-selective exhaustive injection-sweeping (ASEI-sweeping) technique, which is a selective on-line sample concentration technique, was first proposed in microemulsion electrokinetic chromatography (MEEKC) for analyses of eight acidic phenolic compounds. In contrast to a capillary that is typically filled with nonmicellar background solution in conventional ASEI-sweeping MEKC method, in the proposed ASEI-sweeping MEEKC method, a capillary is filled with a low pH microemulsion solution (pH 2.0), and then with a short acid plug (pH 2.0, 1.9 cm) before field-amplified sample injection. This proposed design has two functions. First, the microemulsion solution that is present at the front of capillary column is able to avoid phase separation of microemulsion solution during MEEKC separation. Second, the presence of the short acid plug would effectively limit the partition behavior of acid analytes with the oil droplets in the microemulsion during field-amplified sample injection; otherwise, the stacking effect of acid analytes would be markedly reduced. This optimal ASEI-sweeping MEEKC method afforded about 96,000-fold to 238,000-fold increases in detection sensitivity in terms of peak areas without any separation efficiency loss when compared to normal MEEKC separation. Furthermore, trace levels (about 3 ng/g) of gallic acid and catechin in foods were also detected successfully by the proposed ASEI-sweeping MEEKC technique.  相似文献   

6.
Cation‐selective exhaustive injection and sweeping followed by a MEKC separation is evaluated for the sensitive analysis of 5‐nitroimidazoles in untreated human serum and urine. Deproteinized serum and urine samples were diluted 76 and 143 times, respectively, in a low‐conductivity solvent (5.00 mM orthophosphoric acid containing 5.0% v/v methanol). Samples were electrokinetically injected at 9.8 kV for 632 s in a previously conditioned fused‐silica capillary (65.0 cm × 50 μm id). Separation was performed at –30 kV and 20°C using 44 mM phosphate buffer (pH 2.5), 123 mM SDS, and 8% v/v tetrahydrofurane as BGE. Signals were monitored at 276 nm and peak area was selected as analytical response. Good linearity (R2 ≥ 0.988) and LODs lower than 1.5 and 1.8 μg/mL were achieved in serum and urine, respectively.  相似文献   

7.
采用胶束扫集毛细管电动色谱技术,建立了测定药物中邻苯二甲酸二甲酯(DMP)、邻苯二甲酸二乙酯(DZP)和邻苯二甲酸二丁酯(DBP)的方法。电泳缓冲体系含80 mmol/L SDS,20 mmol/L NaH2PO4(pH 2.20),5%甲醇(V/V),分离电压-18 kV,重力进样80s×15.0cm,检测波长225 nm,使用Φ50μm×62.0 cm石英毛细管,有效长度50.0 cm。讨论了磷酸盐浓度、有机改善剂、SDS浓度、分离电压、进样时间等因素的影响,并考察了胶束扫集法对DMP、DEP和DBP的富集能力。在优化条件下,线性关系良好,相关系数大于0.9986,DMP、DEP和DBP的线性范围分别为1.25~240,1.04~200和1.56~200 mg/L,检出限分别为0.26,0.26和0.39 mg/L。方法应用于肠溶片中DMP、DEP和DBP的测定,回收率在93.3%~108%之间,RSD≤5.2%。每次样品测定可在10 min内完成。  相似文献   

8.
A method based on magnetic separation was developed for the extraction of several estrogens (including diethylstilbestrol, estrone and estriol) in water followed by sweeping micellar electrokinetic chromatography (MEKC) analysis with UV detection. Novel magnetic octadecylsilane (ODS) particles were prepared using a silanization method with octadecyl trimethoxysilane as the surface modification reagent of magnetic Fe3O4 particles. Octadecyl trimethoxysilane was covalently immobilized on the magnetic iron oxide particles. The particles were used as the sorbents in the magnetic separation for the extraction of trace amounts of estrogens from water. The extraction condition and efficiency of the particles for the estrogens were investigated. Combining the magnetic ODS particles extraction and sweeping MEKC with UV detection, the estrogens at concentrations as low as ng/mL in water can be detected without interference from other substances in the sample matrix.  相似文献   

9.
Meng P  Fang N  Wang M  Liu H  Chen DD 《Electrophoresis》2006,27(16):3210-3217
Cation-selective exhaustive injection (CSEI) is used as an on-line concentration method for the high-sensitivity analysis of illicit amphetamines using CE. Optimum conditions for the determination of amphetamine, methamphetamine and methylenedioxy-methamphetamine were investigated. Sodium dodecyl sulfate (25 mM) in 100 mM phosphate buffer (pH 2.9) with 20% methanol as organic additive was used as the background electrolyte for CE separation. The LOD, based on an S/N of 3:1, was about 0.01 microg/mL using normal capillary micellar electrokinetic chromatography, while by using CSEI in combination with micellar sweeping the sensitivity increased up to 1000-fold with the LOD lower than 50 pg/mL. The reproducibility of CSEI combined with micellar sweeping for analyzing amphetamines was satisfactory (relative standard deviation around 10% by using area ratios against an internal standard). This method is highly sensitive and can be used to analyze trace amount amphetamines in human hair.  相似文献   

10.
胶束在线扫集毛细管电泳法测定三聚氰胺   总被引:1,自引:0,他引:1  
研究胶束在线扫集毛细管电泳法测定三聚氰胺的可行性,结果表明,与区带毛细管电泳相比,胶束在线扫集毛细管电泳法富集倍数提高约60倍。缓冲体系为140 mmol/L SDS+20 mmol/L NaH2PO4(pH 2.20)+10%(体积分数)甲醇,分离电压-18 kV,进样时间30 s,测量波长214 nm。考察了SDS浓度、pH、进样时间、运行电压等因素对分离测定的影响情况。在优化条件下,三聚氰胺在9 min时出峰,峰面积RSD≤3.7%。方法检出限、线性范围、相关系数分别为:0.13μg/mL、0.50~32.0μg/mL、0.9997。方法可用于奶粉中三聚氰胺的分离测定。  相似文献   

11.
陈新  袁红萍  曹玉华  陈秋云 《色谱》2010,28(9):889-892
建立了一个毛细管胶束电动色谱(MEKC)在线富集阴离子耗尽进样(ASEI)联用扫集(sweeping)技术测定3种甘草黄酮化合物(异甘草素、甘草素和甘草苷)的方法。考察了MEKC的分离条件和富集体系的优化条件,其中样品基质、水塞进入时间、进样时间对目标化合物的富集效果有较大的影响。在优化实验条件下,异甘草素、甘草素和甘草苷的富集倍数分别提高了110、120、300倍,检出限分别为0.015、0.014、0.011mg/L。该方法用于中药制剂中甘草素、异甘草素和甘草苷含量的测定,回收率在90.6%~107%之间,相对标准偏差(RSD)均小于4.5%(n=3)。实验证明,该方法可成功地应用于实际样品中甘草素、异甘草素和甘草苷含量的测定  相似文献   

12.
Chiang HY  Sheu SJ 《Electrophoresis》2004,25(4-5):670-676
Two stacking methods of capillary electrophoresis (CE) were developed for the separation of very dilute solutions of ephedra-alkaloids, namely ephedrine, pseudoephedrine, methylephedrine, methylpseudoephedrine, norephedrine, and norpseudoephedrine. A sweeping method which uses a carrier comprised of phosphoric acid, sodium dodecyl sulfate (SDS), diethylamine and acetonitrile permits the detection of the alkaloids down to the 10(-1) microg/mL level, and the cation-selective exhaustive injection and sweeping micellar electrokinetic chromatography (CSEI-Sweep-MEKC) method using phosphoric acid, SDS, and acetronitrile as electrolytes can detect down to the 10(-3) microg/mL level. The former requires the conductance of the sample solution to be adjusted beforehand, and only five peaks were observed, two of which were overlapped. The latter is capable of separating the six alkaloids but has a somewhat poorer reproducibility. Using an optimized injection time, it was found that the more diluted a solution is, the greater the sweeping effect will be. The CSEI-Sweep-MEKC method with a 600 s injection time and a 10(-1) microg/mL solution concentration provides an amplification effect of approximately 10(4). The method is suitable for analyses of dilute herb drug extracts and mouse sera. The effect of buffers on the separation and validation of the methods in this study are also discussed.  相似文献   

13.
胆汁酸钠(SC)-十二烷基硫酸钠(SDS)混合胶束电动毛细管色谱法分离测定妈富隆片剂中的炔雌醇,分离缓冲液为SC(55mmol/L)-SDS(15mmol/L)-Tris磷酸(50mmol/L)(pH8.05),分离电压20kV,温度20℃,75μm(i.d)*57.5酮为内标,炔雌醇质量浓度在75.15-901.8μg/mL之间呈良好的线性关系,加样回收率96.4%-104.5%,RSD为3.6%-4.9%(n=3),可用于复方制剂中炔雌醇的含量测定。  相似文献   

14.
15.
建立了一种用来分离测定己烯雌酚的胶束电动色谱法,。通过对十二烷基硫酸钠、胆酸钠、脱氧胆酸钠3种表面活性剂进行比较,选定以60mmol/LSDS 10mmol/L硼砂的水溶液作为背景电解质溶液,研究了不同pH对分离己烯雌酚的影响。该方法被应用于测定己烯雌酚片剂中有效成分的含量。  相似文献   

16.
The separation and determination of aminophenols and phenylenediamines were investigated by liquid chromatography (LC) and micellar electrokinetic chromatography (MEKC) in this study. Aminophenols and phenylenediamines are commonly used components in commercial hair colorants. The problem of tailing peaks in LC was improved by the technique of using mobile phase containing 15 mM triethylamine at pH 8.0. The analysis of o-aminophenol was not succeeded with LC even though the modifier of triethylamine was added. But it could be quantitative successfully by MEKC. The optimum separation condition of MEKC was achieved by employing 55 mM cetyltrimethyl ammonium chloride in 50 mM borate buffer (pH 9.2) with electric field strength of −145 V cm−1. Finally, the commercial hair dyes were analyzed by developing methods of LC and MEKC. From both the results, there is no significant difference presence at 99.5% confidence level. These two methods could give the complementary results.  相似文献   

17.
Retention indices in micellar electrokinetic chromatography   总被引:1,自引:0,他引:1  
The use of retention indices in micellar electrokinetic chromatography (MEKC) is evaluated both from a theoretical and a practical point of view. Fundamental equations for the determination of retention indices in MEKC are described, showing that retention indices are independent of the surfactant concentration. Possibilities as well as limitations of different homologous series as reference standards are described. In addition, the practical application of retention indices for identification, investigation of solute-micelle interactions, characterization and classification of pseudo-stationary phases and determination of solute lipophilicity are discussed.  相似文献   

18.
The limited peak capacity of neutral compounds in micellar electrokinetic chromatography (MEKC) causes peak overlap in a simple 38-compound sample that is predicted by statistical-overlap theory (SOT). The low-concentration sample was prepared in-house from several compound classes to span the entire migration-time range and was resolved partially in a pH=7 phosphate buffer containing 50 mM sodium dodecyl sulfate. Peaks, singlets, doublets, and other multiplets were identified on the basis of known migration times and were counted at 13 voltages spanning 4 – 26 kV. These numbers agreed well with predictions of a simple SOT based on the assumption of an inhomogeneous Poisson distribution of migration times. Because the dispersion theory of MEKC is simple, the standard deviations of single-component peaks were modeled theoretically. As part of a new way to implement SOT, probability distributions of the numbers of peaks, singlets, and so on, were computed by Monte Carlo simulation. These distributions contain all theoretical information on peak multiplicity predictable by SOT and were used to evaluate the agreement between experiment and theory. The peak capacity of MEKC was calculated numerically and substituted into the simplest equations in SOT, affirming that peak overlap arises from limited peak capacity.  相似文献   

19.
We have employed a rapid and highly efficient on-line preconcentration method, cation-selective exhaustive injection and sweeping micellar electrokinetic chromatography (CSEI-sweeping-MEKC), for the analysis of selective serotonin reuptake inhibitors (SSRIs) of antidepressant drugs. We monitored the effects of several of the CSEI-sweeping-MEKC parameters - including the pH, the concentrations of high-conductivity buffer (HCB), sodium dodecyl sulfate (SDS), and organic modifier, the injection length of the HCB, and the injection time of the sample - to optimize the separation process. The optimal background electrolyte was 50 mM citric acid/disodium hydrogenphosphate buffer (pH 2.2) containing 100 mM SDS and 22% isopropyl alcohol. The sensitivity enhancements of the SSRIs sertraline, fluoxetine, paroxetine, fluvoxamine, and citalopram ranged from 5.7 x 10(4) to 1.2 x 10(5); the coefficients of determination exceeded 0.9938 and the relative standard deviations of the peak heights were less than 3.2%; the detection limits ranged from 0.056 to 0.22 ng/mL. We employed the optimal conditions to analyze these five SSRIs in a plasma sample prepared using solid-phase extraction (SPE) to minimize the influence of the matrix. Although the limits of detection of the SSRIs in human plasma were higher than those in pure water, this present technique is more sensitive than other, more-conventional methods. The recovery of the SPE extraction efficiency was satisfactory (up to 89%). Our findings suggest that, under the optimal conditions, the CSEI-sweeping-MEKC method can be used successfully to determine these five SSRIs in human plasma.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号