首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Physically adsorbed (dynamic) polymeric wall coatings for microchannel electrophoresis have distinct advantages over covalently linked coatings. In order to determine the critical factors that control the formation of dynamic wall coatings, we have created a set of model polymers and copolymers based on N,N-dimethylacrylamide (DMA) and N,N-diethylacrylamide (DEA), and studied their adsorption behavior from aqueous solution as well as their performance for microchannel electrophoresis of DNA. This study is revealing in terms of the polymer properties that help create an "ideal" wall coating. Our measurements indicate that the chemical nature of the coating polymer strongly impacts its electroosmotic flow (EOF) suppression capabilities. Additionally, we find that a critical polymer chain length is required for polymers of this type to perform effectively as microchannel wall coatings. The effective mobilities of double-stranded (dsDNA) fragments within dynamically coated capillaries were determined in order to correlate polymer hydrophobicity with separation performance. Even for dsDNA, which is not expected to be a strongly adsorbing analyte, wall coating hydrophobicity has a deleterious influence on separation performance.  相似文献   

2.
Surface modifications of microfluidic devices are of essential importance for successful bioanalytical applications. Here, we investigate three different coatings for quartz and poly(dimethylsiloxane) (PDMS) surfaces. We employed a triblock copolymer with trade name F108, poly(l-lysine)-g-poly(ethylene glycol) (PLL-PEG), as well as the hybrid coating n-dodecyl-β-d-maltoside and methyl cellulose (DDM/MC). The impact of these coatings was characterized by measuring the electroosmotic flow (EOF), contact angle, and prevention of protein adsorption. Furthermore, we investigated the influence of static coatings, i.e., the incubation with the coating agent prior to measurements, and dynamic coatings, where the coating agent was present during the measurement. We found that all coatings on PDMS as well as quartz reduced EOF, increased reproducibility of EOF, reduced protein adsorption, and improved the wettability of the surfaces. Among the coating strategies tested, the dynamic coatings with DDM/MC and F108 demonstrated maximal reduction of EOF and protein adsorption and simultaneously best long-term stability concerning EOF. For PLL-PEG, a reversal in the EOF direction was observed. Interestingly, the static surface coating strategy with F108 proved to be as effective to prevent protein adsorption as dynamic coating with this block copolymer. These findings will allow optimized parameter choices for coating strategies on PDMS and quartz microfluidic devices in which control of EOF and reduced biofouling are indispensable.  相似文献   

3.
Sun X  Liu J  Lee ML 《Electrophoresis》2008,29(13):2760-2767
In-channel atom transfer radical polymerization (ATRP) was used to graft a PEG layer on the surface of microchannels formed in poly(glycidyl methacrylate)-co-(methyl methacrylate) (PGMAMMA) microfluidic devices. The patterned and cover plates were first anchored with ATRP initiator and then thermally bonded together, followed by pumping a solution containing monomer, catalyst, and ligand into the channel to perform ATRP. A PEG-functionalized layer was grafted on the microchannel wall, which resists protein adsorption. X-ray photoelectron spectroscopy (XPS) was used to investigate the initiator-bound surface, and EOF was measured to evaluate the PEG-grafted PGMAMMA microchannel. Fast, efficient, and reproducible separations of amino acids, peptides, and proteins were obtained using the resultant microdevices. Separation efficiencies were higher than 1.0x10(4) plates for a 3.5 cm separation microchannel. Compared with microdevices modified using a previously reported ATRP technique, these in-channel modified microdevices demonstrated better long-term stability.  相似文献   

4.
Capillary coatings are crucial for high-quality separation performance in capillary electrophoresis analysis of proteins or peptides as they prevent analyte adsorption at the capillary wall. These coating materials have to fulfill many requirements such as a good separation performance and ensuring a good repeatability. The number of commercially available coating materials is still limited, especially with regard to the charge density on the coating material and the induced electroosmotic flow (EOF) velocity. In this work, we compare the separation performance of the novel self-made cationic capillary coating OHNOON and two commercially available coating materials, the acrylamide based, neutral LN® and the cationic hexadimethrine bromide (Polybrene), using the same coating procedure for all three coating materials. The coatings are investigated regarding the separation efficiency, analyte resolution, coating stability, and migration time stability in tryptic peptide analysis. Good separation performance was confirmed for all three coating materials: all coatings provided high plate numbers of up to 400,000–500,000 and a repeatability of the EOF and the analyte migration times in the range of 1 % relative standard deviation or below. Our results reveal a moderate EOF velocity for the novel OHNOON coating in comparison to the Polybrene coating. We present a detailed discussion of the impact of this reduced EOF velocity and the separation performance. The results presented here will help to define the necessary properties of coating materials to achieve the best compromise between speed of analysis and resolution for the respective application. We show that our novel OHNOON coating is especially valuable for the analysis of low mobility analytes and for samples with a broad range of analyte mobilities.  相似文献   

5.
Organic polymers offer many advantages as materials for the construction of microfluidic devices but suffer frequently from the limitation that the electrodynamic flow they support can exhibit considerable instability. This article describes a split-channel microfluidic device that can be used to compensate for changes in electroosmotic flow. The design of the separation system divides an analyte plug after injection between two separation channels of differing length. The two channels are later recombined for single point detection, eliminating the need for a scanning optical detection system. The utility of this simple design lies in the fact that the migration time of any analyte can be referenced to its twin in the parallel separation channel. This eliminates the need for a separate electroosmotic marker and allows mobilities measured in multiple devices to be compared quantitatively. Using a model adopted from the literature, the data from the split channel system can be used to precisely account for the drift that characterizes electrophoretic separations made in a polymer chip. The relative standard deviations of the analyte mobilities measured for replicate runs on multiple devices were reduced from values as high as 20% to ca. 1% RSD. This internal standardization procedure also appears to address other sources of drift in the electroosmotic flow (EOF) supported by the polymer microchannel, eliminating the need for careful monitoring of either the temperature or reservoir pH between separation runs.  相似文献   

6.
Yu H  He FY  Lu Y  Hu YL  Zhong HY  Xia XH 《Talanta》2008,75(1):43-48
Separation and determination of dopamine and epinephrine with end-channel electrochemical (EC) detection integrated on a native printed microchip capillary electrophoresis (CE) system was investigated. Factors influencing the separation and detection were investigated and optimized. Results show manipulating EOF, which can be easily achieved by adjusting buffer pH, is a simple and effective way to achieve the baseline separation of dopamine and epinephrine in native polymeric microchips. Without surface modification of microchannel, printed microchips with advantages of low cost and easy preparation can achieve high performance like other microfluidic devices.  相似文献   

7.
Control of surface properties in microfluidic systems is an indispensable prerequisite for successful bioanalytical applications. Poly(dimethylsiloxane) (PDMS) microfluidic devices are hampered from unwanted adsorption of biomolecules and lack of methods to control electroosmotic flow (EOF). In this paper, we propose different strategies to coat PDMS surfaces with poly(oxyethylene) (POE) molecules of varying chain lengths. The native PDMS surface is pretreated by exposure to UV irradiation or to an oxygen plasma, and the covalent linkage of POE-silanes as well as physical adsorption of a triblock-copolymer (F108) are studied. Contact angle measurements and atomic force microscopy (AFM) imaging revealed homogeneous attachment of POE-silanes and F108 to the PDMS surfaces. In the case of F108, different adsorption mechanisms to hydrophilic and hydrophobic PDMS are discussed. Determination of the electroosmotic mobilities of these coatings in PDMS microchannels prove their use for electrokinetic applications in which EOF reduction is inevitable and protein adsorption has to be suppressed.  相似文献   

8.
A new scheme has been described for continuous particle separation using EOF in microfluidic devices. We have previously reported a method for particle separation, called "pinched flow fractionation (PFF)", in which size-dependent and continuous particle separation can be achieved by introducing pressure-driven flows with and without particles into a pinched microchannel. In this study, EOF was employed to transport fluid flows inside a microchannel. By controlling the applied voltage to electrodes inserted in each inlet/outlet port, the flow rates from both inlets, and flow rates distributed to each outlet could be accurately tuned, thus enabling more effective separation compared to the pressure-driven scheme. In the experiment, the particle behaviors were compared between EOF and pressure-driven flow schemes. In addition, micrometer- and submicrometer-sized particles were accurately separated and individually collected using a microchannel with multiple outlet branch channels, demonstrating the high efficiency of the presented scheme.  相似文献   

9.
Surface modification of polymer materials for preparing microfluidic devices including poly(dimethyl siloxane) (PDMS) was investigated with phospholipids polymers such as poly(2-methacryloyloxylethyl phosphorylcholine(MPC)-co-n-butyl methacrylate) (PMB) and poly(MPC-co-2-ethylhexyl methacrylate-co-2-(N,N-dimethylamino)ethyl methacrylate) (PMED). The hydrophilicity of every surface on the polymer materials modified with these MPC polymers increased and the value of zeta-potential became close to zero. The protein adsorption on the polymer materials with and without the surface modification was evaluated using a protein mixture of human plasma fibrinogen and serum albumin. Amount of proteins adsorbed on these polymeric materials showed significant reduction by the surface modification with the MPC polymers compared to the uncoated surfaces ranging from 56 to 90%. Furthermore, we successfully prepared PDMS-based microchannel which was modified by simple coating with the PMB and PMED. The modified microchannel also revealed a significant reduction of adsorption of serum albumin. We conclude that the MPC polymers are useful for reducing unfavorable protein adsorption on microfluidic devices.  相似文献   

10.
A method for studying peptide-surface interactions within microfluidic channels by radionuclide imaging is described. With the high surface area-to-volume ratio of channels in miniaturised devices, combined with low amounts of analyte, non-specific peptide adsorption is a critical issue. The objective of the study was therefore to develop a method capable of direct detection of adsorbed peptide within microfluidic channels. A micro-device consisting of channels moulded in a plastic compact disc was chosen for the study, together with two selected peptides of different lengths and isoelectric point (pI) values. A bifunctional chelator, DOTA, was attached to the peptide by conjugation and labelled with the short-lived positron emitting radionuclide 68Ga. Quantitative images of radiotracer distribution within the microfluidic channels were obtained using a PhosphorImager system. The power of the method was demonstrated by the ability to clearly measure changes in adsorption when varying a number of parameters that typically affect peptide adsorption. These included surface modifications, analyte concentration, pH, and ionic strength. Additionally, two quantification methods were developed and compared. Radionuclide imaging also permitted visualisation of adsorption and release processes in microchannel chromatographic columns. The results suggest that radionuclide imaging is a suitable tool not only for the study of peptide adsorption to the microchannels presented in this study but also as a versatile tool to measure peptide-surface interactions in a wide variety of miniaturised structures and devices.  相似文献   

11.
This paper presents a study of EOF properties of plasma‐polymerized microchannel surfaces and the effects of protein (fibrinogen and lysozyme) adsorption on the EOF behavior of the surface‐modified microchannels. Three plasma polymer surfaces, i.e. tetraglyme, acrylic acid and allylamine, are tested. Results indicate EOF suppression in all plasma‐coated channels compared with the uncoated glass microchannel surfaces. The EOF behaviors of the modified microchannels after exposure to protein solutions are also investigated and show that even low levels of protein adsorption can significantly influence EOF behavior, and in some cases, result in the reversal of flow. The results also highlight that EOF measurement can be used as a method for detecting the presence of proteins within microchannels at low surface coverage (<1 ng/cm2 on glass). Critically, the results illustrate that the non‐fouling tetraglyme plasma polymer is able to sustain EOF. Comparison of the plasma‐polymerized surfaces with conventionally grafted polyelectrolyte surfaces demonstrates the stabilities of the plasma polymer films, enabling multiple EOF runs over 3 days without deterioration in performance. The results of this study clearly demonstrate that plasma polymers enable the surface chemistry of microfluidic devices to be tailored for specific applications. Critically, the deposition of the non‐fouling tetraglyme coating enables stable EOF to be induced in the presence of protein.  相似文献   

12.
Xu Y  Takai M  Konno T  Ishihara K 《Lab on a chip》2007,7(2):199-206
A type of charged phospholipid polymer biointerface was constructed on a quartz microfluidic chip to control the electroosmotic flow (EOF) and to suppress non-specific protein adsorption through one-step modification. A negatively charged phospholipid copolymer containing 2-methacryloyloxyethyl phosphorylcholine (MPC), n-butyl methacrylate (BMA), potassium 3-methacryloyloxypropyl sulfonate (PMPS) and 3-methacryloxypropyl trimethoxysilane (MPTMSi) moieties (referred to as PMBSSi) was synthesized to introduce such phosphorylcholine segments as well as surface charges onto the silica-based microchannels via chemical bonding. At neutral pH, the homogenous microchannel surface modified with 0.3 wt% PMBSSi in alcoholic solution, retained a significant cathodic EOF ((1.0 +/- 0.1) x 10(-4) cm(2) V(-1) s(-1)) with approximately one-half of the EOF of the unmodified microchannel ((1.9 +/- 0.1) x 10(-4) cm(2) V(-1) s(-1)). Along with another non-charged copolymer (poly(MPC-co-MPTMSi), PMSi), the regulation of the surface charge density can be realized by adjusting the concentration of PMBSSi or PMSi initial solutions for modification. Coincidently, the zeta-potential and the EOF mobility at neutral pH showed a monotonically descending trend with the decrease in the charge densities on the surfaces. This provides a simple but feasible approach to controlling the EOF, especially with regard to satisfying the requisites of miniaturized systems for biological applications requiring neutral buffer conditions. In addition, the EOF in microchannels modified with PMBSSi and PMSi could maintain stability for a long time at neutral pH. In contrast to the EOF in the unmodified microchannel, the EOF in the modified microchannel was only slightly affected by the change in pH (from 1 to 10). Most importantly, although PMBSSi possesses negative charges, the non-specific adsorptions of both anionic and cationic proteins (considering albumin and cytochrome c, respectively, as examples) were effectively suppressed to a level of 0.15 microg cm(-2) and lesser in the case of the 0.3 wt% PMBSSi modification. Consequently, the variation in the EOF mobility resulting from the protein adsorption was also suppressed simultaneously. To facilitate easy EOF control with compatibility to biomolecules delivered in the microfluidic devices, the charged interface described could provide a promising option.  相似文献   

13.
Liu Q  Yuan J  Li Y  Yao S 《Electrophoresis》2008,29(4):871-879
In this paper, we presented the first example of using gemini surfactants as semipermanent coatings in CE for protein separation. These coatings are based on the self-assembly of a series of cationic gemini surfactants, alkanediyl-alpha,omega-bis(dimethylalkylammonium bromide) (m-s-m), on the capillary wall. The coatings can keep stable for a long time without surfactant in the buffer, e.g., after the surfactants were removed from the buffer, the reversed EOF only decreased by 3.6 and 3.9% for 18-2-18 and 16-2-16 coatings over 60 min under continuous electrophoretic conditions. The coating stability increased with the alkyl chain length m. The double long chains of geminis (m > or = 14) yielded a good coating stability; meanwhile, the spacer group acted as an EOF modifier. Thus, this bifunctional surfactant coating provided a new buffer-independent method for EOF control. For 18-s-18 series, the best coating stability and largest EOF were obtained at s = 10. Ranging s from 3 to 10 yielded a linear fine-tuning of EOF and thereby allowed the adjustment of the protein apparent mobility. Highly efficient separation (>500 000 plates/m) was achieved with all the 18-s-18 coatings. Excellent run-to-run and day-to-day reproducibility (RSD of migration time 相似文献   

14.
董娅妮  方群 《色谱》2008,26(3):269-273
重点介绍了近年来国内外在微流控芯片毛细管电泳法用于蛋白质分离分析方面的研究进展。按照分离模式的不同,综述了各种应用于蛋白质分离的微流控芯片毛细管电泳系统,讨论了抑制芯片中的蛋白吸附的各种方法,并展望了芯片毛细管电泳系统在蛋白质分离领域的发展前景。引用文献47篇。  相似文献   

15.
Semipermanent surfactant coatings are effective for the prevention of wall adsorption of proteins in CE. However, they often suffer from their unsatisfactory coating stability as they essentially degrade from the capillary walls after the surfactants are removed from the buffer. In this paper, we proposed a facile and universal method to improve the stability of semipermanent surfactant coatings based on addition of an oppositely charged surfactant into the coating. Didodecyldimethylammonium bromide (DDAB) and a gemini surfactant, 18-6-18, were used as the model semipermanent coatings, and sodium dodecyl sulfate (SDS) was chosen as their oppositely charged surfactant. SDS can strongly alter the packing parameter P of the cationic surfactants, and consequently mediates the coating stability. With the increase of SDS concentration in coating, the coating stability first dramatically increases due to the enlarged P, and then decreases due to the weakness of electrostatic interaction between the capillary wall and surfactant coating. At the proper SDS concentration, very stable coatings can be obtained that, even after rinsing under 138 kPa for 60 min, the reversed electroosmotic flow (EOF) only decreases by 3.6%. These SDS-enhanced coatings show excellent stability and reproducibility in protein separation (RSD of migration time <1.1% for run-to-run assay, n=9). Also, the high separation efficiency (>500,000 plates/m) and fine recovery of tested proteins indicate that these coatings are powerful in wall adsorption suppression. Finally, we found that the separation efficiency of protein was a more exact indicator for the coating stability than the traditional EOF magnitude.  相似文献   

16.
G Azadi  A Tripathi 《Electrophoresis》2012,33(14):2094-2101
Control of EOF in microfluidic devices is essential in applications such as protein/DNA sizing and high‐throughput drug screening. With the growing popularity of poly(methyl methacrylate) (PMMA) as the substrate for polymeric‐based microfludics, it is important to understand the effect of surfactants on EOF in these devices. In this article, we present an extensive investigation exploring changes in EOF rate induced by SDS, polyoxyethylene lauryl ether (Brij35) and CTAB in PMMA microfluidic capillaries. In a standard protein buffer (Tris‐Glycine), PMMA capillaries exhibited a cathodic EOF with measured mobility of 1.54 ± 0.1 (× 10?4 cm2/V.s). In the presence of surfactant below a critical concentration, EOF was independent of surfactant concentration. At high concentrations of surfactants, the electroosmotic mobility was found to linearly increase/decrease as the logarithm of concentration before reaching a constant value. With SDS, the EOF increased by 257% (compared to buffer), while it was decreased by 238% with CTAB. In the case of Brij35, the electroosmotic mobility was reduced by 70%. In a binary surfactant system of SDS/CTAB and SDS/Brij35, addition of oppositely charged CTAB reduced the SDS‐induced EOF more effectively compared to nonionic Brij35. We propose possible mechanisms that explain the observed changes in EOF and zeta potential values. Use of neutral polymer coatings in combination with SDS resulted in 50% reduction in the electroosmotic mobility with 0.1% hydroxypropyl methyl cellulose (HPMC), while including 2% poly (N,N‐dimethylacrylamide) (PDMA) had no effect. These results will potentially contribute to the development of PMMA‐based microfluidic devices.  相似文献   

17.
Hu Y  Li D 《Analytica chimica acta》2007,581(1):42-52
Understanding nucleic acid adsorption in microchannels is critical to improve the efficiency of purifying and extracting nucleic acid (NA) from sample solutions by microfluidic technologies. Using a microchannel with 3D prismatic silica elements on the wall can dramatically increase the surface area-to-volume ratio, and hence facilitate the nucleic acid adsorption on the wall. In this study a theoretical model for modeling adsorption in a microchannel with a designed 3D surface structure was developed, and five dimensionless numbers were found to be the key parameters in the adsorption process. Extensive numerical simulations were conducted. Two flow modes, the electroosmotic flow (EOF) and pressure-driven flow (PDF), were investigated for their effect on the adsorption. It was found that the EOF is more desirable than PDF. The 3D prismatic elements can increases the NA molecule adsorption not only by providing more surface areas, but also by the induced pressure resisting the central bulk electroosmotic flow. Finally, the effects of adsorption kinetic parameters (i.e., the kinetic association/dissociation constants, the diffusion coefficient, the total site density, the loading concentration, and the channel height), on the adsorption process were discussed in detail.  相似文献   

18.
J S Buch  P C Wang  D L DeVoe  C S Lee 《Electrophoresis》2001,22(18):3902-3907
The application of the field-effect for direct control of electroosmosis in a polydimethylsiloxane (PDMS)-based microfluidic system, constructed on a silicon wafer with a 2.0 microm electrically insulating layer of silicon dioxide, is demonstrated. This microfluidic system consists of a 2.0 cm open microchannel fabricated on a PDMS slab, which can reversibly adhere to the silicon wafer to form a hybrid microfluidic device. Aside from mechanically serving as a robust bottom substrate to seal the channel and support the microfluidic system, the silicon wafer is exploited to achieve field-effect flow control by grounding the semiconductive silicon medium. When an electric field is applied through the channel, a radial electric potential gradient is created across the silicon dioxide layer that allows for direct control of the zeta potential and the resulting electroosmotic flow (EOF). By configuring this microfluidic system with two power supplies at both ends of the microchannel, the applied electric potentials can be varied for manipulating the polarity and the magnitude of the radial electric potential gradient across the silicon dioxide layer. At the same time, the longitudinal potential gradient through the microchannel, which is used to induce EOF, is held constant. The results of EOF control in this hybrid microfluidic system are presented for phosphate buffer at pH 3 and pH 5. It is also demonstrated that EOF control can be performed at higher solution pH of 6 and 7.4 by modifying the silicon wafer surface with cetyltrimethylammonium bromide (CTAB) prior to assembly of the hybrid microfluidic system. Results of EOF control from this study are compared with those reported in the literature involving the use of other microfluidic devices under comparable solution conditions.  相似文献   

19.
CE of biomolecules is limited by analyte adsorption on the capillary wall. To prevent this, monolayer or successive multiple ionic‐polymer layers (SMILs) of highly charged polyelectrolytes can be physically adsorbed on the inner capillary surface. Although these coatings have become commonly used in CE, no systematic investigation of their performance under different coating conditions has been carried out so far. In a previous study (Nehmé, R., Perrin, C., Cottet, H., Blanchin, M. D., Fabre, H., Electrophoresis 2008, 29, 3013–3023), we investigated the influence of different experimental parameters on coating stability, repeatability and peptide peak efficiency. Optimal coating conditions for monolayer and multilayer (SMILs) poly(diallyldimethylammonium) chloride/ poly(sodium 4‐styrenesulfonate) coated capillaries were determined. In this study, the influence of polyelectrolyte concentration and ionic strength of the coating solutions, and the number of coating layers on coating stability and performance in limiting protein adsorption was carried out. EOF magnitude and repeatability were used to monitor coating stability. Coating ability to limit protein adsorption was investigated by monitoring variations of migration times, time‐corrected peak areas and separation efficiency of test proteins. The separation performance of polyelectrolyte coatings were compared with those obtained with bare silica capillaries.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号