首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Summary Reversed-phase liquid-liquid chromatographic systems consisting of an aqueous mobile phase and an organic liquid stationary phase of the proton acceptor tri-n-octylphosphine oxide (TOPO) inn-decane, coated on LiChrosorb RP-8, have been studied. The solutes were hydrophilic aromatic carboxylic acids and phenol. The retention of the carboxylic acids shows a minimum at 10 mM of TOPO, whereas increasingly tailing peaks have been obtained with decreasing concentrations of TOPO. This behaviour is due to a concurrent complex formation by hydrogen bonding with TOPO in the liquid stationary phase and adsorption at the interface between the support and the liquid stationary phase. The adsorption of TOPO, ketones and aromatic acids from hexane on Li-Chrosorb RP-8 has been studied, and seems to be due to residual silanol groups. The adsorption isotherm of TOPO has been determined and can be described by a two-site Langmuir adsorption model. Non polar solutes are not adsorbed. The influence of TOPO on the retention and the peak symmetry of carboxylic acids in the liquid-liquid chromatographic system appears to be due to a competition between TOPO and the acids for the same adsorption sites. No competition was found for phenol.Presented at the 14th International Symposium on Chromatography London, September, 1982  相似文献   

2.
Summary Silica-bonded stationary phases were developed for the separation of nucleic acid constituents and their properties investigated with homologous oligoriboadenylic acids in electrostatic interaction chromatography and with alkylbenzenes in reversed-phase chromatography. Analysis of retention data confirmed the stratified molecular structure of the surface which consist of a layer of propyl chains anchoredvia siloxane bridges to the silica surface proper and of polar moieties attached to the hydrocarbonaceous functions. The polar top layer contains weak cationic and/or hydrophobic binding sites, is strongly hydrated in contact with aqueous eluents and bars the access by large biopolymers to the hydrocarbonaceous sublayer. In reversed-phase chromatography of small non polar molecules with hydro-organic eluents, however, this layer is accessible and engenders a retentive behavior typical for weak hydro-carbonaceous bonded phases. As a result the stationary phases, depending on the nature of the sample and the mobile phase, exhibit the properties of "soft" phases for the chromatography of biopolymers under mild elution conditions and those of "hard" phases for the separation of small non-polar molecules under conditions generally employed in reversed-phase chromatography. The retention of nucleic acid constituents on most of the stationary phases investigated subject to a dual mechanism as a result of the interplay of electrostatic and hydrophobic interactions between the eluites and the binding sites on the stationary phase surface. Siliceous stationary phases having surface morphology described above are suitable for the separation of nucleic acid constituents having widely ranging molecular weights up to 3 × 106 Daltons provided the support has appropriate pore dimensions. This is demonstrated by the separation of mixtures arising from digesting t-RNApha or polyadenylic acids as well as those of ribosomal RNA’s and different forms of the plasmid pBR322 DNA. Presented at the 15th International Symposium on Chromatography, Nürnberg, October 1984  相似文献   

3.
In this work, a poly-l-lysine-grafted stationary phase was synthesized by polymerization of N-carboxyanhydride of l-lysine initiated by 3-aminopropylated silica. The resulting material was characterized by FT-IR spectra, elemental analysis and thermogravimetric analysis, which clearly indicated that the new phase had been prepared successfully. The retention of polar solutes depending on acetonitrile content in mobile phase exhibited ??U-shaped?? curves, which was an indication of hydrophilic interaction liquid chromatography (HILIC)/reversed-phase liquid chromatography (RPLC) mixed-mode retention behavior. The retention mechanisms in HILIC and RPLC modes also were investigated. Phenol compounds, aniline compounds and hydrophilic compounds were separated in RPLC or HILIC mode on the new stationary phase, respectively. This result shows that the new phase could be used for both RPLC and HILIC applications, providing greater flexibility for real sample analysis.  相似文献   

4.
Nowicky W  Han LF  Nowicky W  Gutmann V  Linert W 《Talanta》1992,39(11):1437-1442
The addition of salts (investigated cations Na(+), NH(+)(4), K(+), KBu(+)(4) combined with the anions acetate, Br(-), SCN(-) and I(-)) can be used to eliminate peak tailing and to decrease retention of cationic species in the course of the separation of alkaloids from Chelidonium majus L. by reversed-phase chromatography on a ODS Hypersil column, using water-acetonitrile-methanol mixture as eluent. These findings are interpreted in terms of a silanol masking effect. The extended donor-acceptor concept is used to interpret the effectiveness of different salts in masking the active sites of the stationary phase.  相似文献   

5.
The potential of 1.7 μm ethylene bridged hybrid silica phase was investigated for the separation of twelve imidazolium-based ionic liquid cations. U-shaped retention profile was observed for all solutes with an increase in retention at both low and high acetonitrile content. Chromatographic behaviour of imidazolium cations in both hydrophilic interaction chromatography (HILIC) and per aqueous liquid chromatography (PALC) modes was studied by varying key parameters such as buffer concentration and pH, acid additive, organic modifier and column temperature. Experimental data provided some evidences that under PALC conditions cationic solutes are retained predominantly by mixed hydrophobic/ion-exchange interactions. In the HILIC mode, both partitioning and ion-exchange interactions are responsible for the retention of solutes. Compared to PALC, HILIC provided significantly higher efficiencies with less or even no peak tailing, better separation selectivity and greater resistance to overload. In PALC mode gradient elution was required to achieve adequate retentivity of all solutes but selectivity was not sufficient to distinguish between solutes with very similar hydrophobicity. In contrast, under HILIC conditions twelve solutes were almost completely resolved in less than 4 min by using isocratic elution. Summarizing, it could be concluded that ethylene bridged hybrid silica column providing a dual retention mechanism offers the possibility of selecting between the two retention modes with opposite separation selectivity, just by changing the composition of the mobile phase.  相似文献   

6.
Summary A new class of stationary phases for high-performance liquid chromatography (HPLC) are described which simulate in their retention chracteristics ion-pair separations. The phases consist of mixtures of chemically dissimilar ligands chemically bonded to silica supports. These phases are largely reversed-phase in nature, but also contain significant ion-exchange properties, at levels similar to those demonstrated to occur in ionpairing. By bonding both ionic and hydrophobic groups in the correct proportions, mixed retention mechanisms are created, resulting in unique selectivities, while retaining the excellent stabilities and efficiencies characteristic of bonded phases. The ratio of hydrophobic to ionic character can be controlled during the synthesis, and is used as a tool to vary the stationary phase, rather than only the mobile phase, to effect the separation desired. The synthesis and behavior of both anionic and cationic/reversed-phase materials are described, and are applied to the simultaneous separation of nucleosides and nucleotides, and to the separation of the catecholamines.Presented at the 14th International Symposium on Chromatography London, September, 1982.  相似文献   

7.
Summary The chromatographic properties of an alkylphosphonate-modified magnesia-zirconia composite stationary phase have been investigated by reversed-phase high-performance liquid chromatography with basic compounds as probes. The influence of organic modifier composition and mobile phase pH was studied. The new stationary phase, similar to a silica-based reversed-phase stationary phase, has hydrophobic properties, but greater pH stability. Use of the phase results in more symmetric peaks for basic compounds. A possible mechanism of retention of basic solutes on the new stationary phase is discussed. The chromatographic behavior of the basic solutes depends mainly on hydrophobic interactions between the solutes and the hydrophobic moiety of the stationary phase. Br?nsted acidic and basic sites on the surface of the new stationary phase play an important role in the retention of ionized solutes by ion-exchange interaction. Promising separations of some basic compounds have been achieved by use of methanolic TRIS buffer, pH 10.0, as the mobile phase.  相似文献   

8.
Allen D  El Rassi Z 《The Analyst》2003,128(10):1249-1256
Three different synthetic routes have been introduced and evaluated for the preparation of amphiphilic silica-based monoliths possessing surface-bound octadecyl ligands and positively charged groups. The amphiphilic silica monoliths (designated as cationic C18-monoliths) have been designed for use in reversed-phase capillary electrochromatography (RP-CEC) with hydro-organic mobile phases. These amphiphilic stationary phases yielded anodic electroosmotic flow (EOF) over a wide range of mobile phase pH. The magnitude of EOF remained constant up to pH 4.0 and then decreased at pH > 4.0 due to the ionization of silanol groups and the subsequent decrease in the net positive surface charge density of the amphiphilic monoliths. The cationic C18-monoliths exhibited reversed-phase chromatography (RPC) behavior toward non-polar solutes (e.g., alkyl benzenes), which parallels that observed with octadecyl-silica (ODS) monoliths. On the other hand, the amphiphilic stationary phases exhibited both non-polar and polar interactions toward slightly polar solutes such as anilines and PTH-amino acids. CEC retention factor k* and velocity factor k*e, which reflects the contribution of the electrophoretic mobility, were evaluated for charged solutes such as anilines and proteins.  相似文献   

9.
The retention of aliphatic hydrocarbons with polar groups has been compared in respect to the separation selectivity changes in reversed-phase high-performance liquid chromatography with C18 stationary phase type and binary water eluent composed of methanol, acetonitrile, or tetrahydrofuran as modifiers. The changes in separation selectivity when one modifier is replaced by another in the eluent is explained, taking into consideration molecular interactions of the solutes with components of the stationary phase region, i.e., extracted modifier, and ordering of the stationary phase by the modifier.  相似文献   

10.
We investigated the effects of the concentration of naphthalene sulphonic acids (NSAs) as anionic test compounds in the injected sample and of the salt additives to the mobile phase on ion-exclusion. The retention behaviour of NSAs sensitively reflects even minor changes in the ionic and hydrophobic interactions and can be useful for predicting the effects of the stationary phases in reversed-phase chromatography of polar and ionic compounds, both small ones and biopolymers, e.g., oligonucleotides. We studied chromatographic properties of several stationary phases intended for separations in aqueous mobile phases: a C18 column end-capped with polar hydrophilic groups, a densely bonded C8 column doubly end-capped with short alkyl groups, a short alkyl stationary phase designed to keep full pore accessibility in highly-aqueous mobile phases and a Bidentate column with “bridged” C18 groups attached to the silica hydride support. The chemistry and pore structure of various types of column packing materials and of the salt additives to the mobile phase affect the proportion of the pore volume non-accessible to anions due to ion-exclusion and consequently the peak asymmetry and hydrophobic selectivity in reversed-phase chromatography of organic acids. We also addressed the problems connected with the determination of column hold-up volume in aqueous mobile phases. The accessibility of the stationary phase for anionic compounds in contact with the sample zone is affected by ion-exclusion due to repulsive interactions with the negatively charged surface in the pores of the stationary phase. The accessible part of the stationary phase increases and consequently the migration velocity along the column decreases with increasing concentration of the sample in the zone moving along the column. Because of a limited access to the stationary phase, its capacity can be easily overloaded. The combination of the column overload and ion-exclusion effects may result in fronting or tailing peak asymmetry. To explain this behaviour, we proposed a modified Langmuir model, respecting the variation of the column capacity due to the effects of sample concentration on ion-exclusion.  相似文献   

11.
Abstract

The mechanism of retention in reversed-phase high performance liquid chromatography is affected by both solute-eluent interactions and the nature of the stationary phase. The hydrophobic expulsion of ionized solutes plays a major role in affecting solute behavior in the water-rich range of hydroorganic eluents. In the water-lean range of eluent composition, there is little hydrophobic expulsion, and specific interactions between the solute and surface can be observed. The nature of the surface affects the retention of a variety of ionized species, both large cations and anions. Octadecylsilane (ODS) bonded phases can exhibit two different binding sites: one exhibiting a weak interaction and the second a strong specific interaction with a solute. Styrenedivinylbenzene polymeric surfaces exhibit the potential for weak dispersion interactions, and in addition pi-bonding interactions with a solute. A variety of solutes have been injected in a water: methanol eluent system in order to assess solute-surface effects on reversed-phase supports.  相似文献   

12.
张静  王玲玲  单联国  卫引茂 《色谱》2012,30(8):804-809
用硅胶与氨丙基三甲氧基硅烷反应,再与δ-葡萄糖酸内酯反应,制备了一种多羟基化合物键合的新型亲水色谱固定相。以水-有机溶剂(乙醇、乙腈、四氢呋喃)为流动相,通过改变流动相中有机溶剂的种类及浓度、缓冲盐浓度和柱温,考察了该固定相对6种强极性中药组分的保留行为和保留机理。当水的比例在0~40%(v/v)范围时,溶质的保留随着流动相中水的比例的增大而减小,属于典型的亲水色谱分离模式;而当流动相中水的比例在0~100%(v/v)范围内变化时,溶质的保留随着水的比例变化呈“U”形曲线,属于亲水色谱和反相色谱的混合保留机理。缓冲盐的浓度和pH效应说明,所选用的中药组分与所制备的固定相间还存在弱的静电作用。该固定相对6种中药组分以及丹参注射液具有良好的分离性能,表明其在强极性中药有效成分的分离及其他强极性物质的分离分析中具有一定的应用前景。  相似文献   

13.
Ultra-performance liquid chromatography (UPLC) in reversed-phase (RP), ion pair (IP) and hydrophilic interaction chromatography (HILIC) has been investigated for the separation of imidazolium-based ionic liquid (IL) cations. Among the three stationary phases (i.e., C18, C8 and phenyl) studied under RP conditions the phenyl phase provided much stronger retention for the IL cations. Four acids (hydrochloric, methanesulfonic, perchloric and trifluoroacetic) as mobile phase additives were compared in light of their effects on the retention of IL cations. It was shown that the retention of all IL cations decreased upon acidification of the mobile phase, possibly due to suppression of residual silanol ionization. Very fast (~3 min) and efficient RP-UPLC separation of six cations was achieved by gradient elution with acetonitrile?Cwater mobile phase containing 2.5 mmol L?1 perchloric acid. In IP-UPLC all solutes were well resolved in about 4 min by gradient elution with acetonitrile?Cwater mobile phase containing 1 mmol L?1 sodium 1-octanesulfonate as ion pairing reagent. Finally, under HILIC conditions by using isocratic elution with acetonitrile?Cwater (85:15, v/v) mobile phase containing 5 mmol L?1 ammonium formate (pH 3.2) the separation time was reduced to less than 2 min while maintaining excellent peak shapes and sufficient resolution. Compared to current LC systems UPLC allowed considerably faster separations with better peak shapes.  相似文献   

14.
We recently introduced a mixed-mode reversed-phase/weak anion-exchange type separation material based on silica particles which consisted of a hydrophobic alkyl strand with polar embedded groups (thioether and amide functionalities) and a terminal weak anion-exchange-type quinuclidine moiety. This stationary phase was designed to separate molecules by lipophilicity and charge differences and was mainly devised for peptide separations with hydroorganic reversed-phase type elution conditions. Herein, we demonstrate the extraordinary flexibility of this RP/WAX phase, in particular for peptide separations, by illustrating its applicability in various chromatographic modes. The column packed with this material can, depending on the solute character and employed elution conditions, exploit attractive or repulsive electrostatic interactions, and/or hydrophobic or hydrophilic interactions as retention and selectivity increments. As a consequence, the column can be operated in a reversed-phase mode (neutral compounds), anion-exchange mode (acidic compounds), ion-exclusion chromatography mode (cationic solutes), hydrophilic interaction chromatography mode (polar compounds), and hydrophobic interaction chromatography mode (e.g., hydrophobic peptides). Mixed-modes of these chromatographic retention principles may be materialized as well. This allows an exceptionally flexible adjustment of retention and selectivity by tuning experimental conditions. The distinct separation mechanisms will be outlined by selected examples of peptide separations in the different modes.  相似文献   

15.
The retentions of 28 peptides in reversed-phase thin-layer chromatography (RPTLC) were determined on cellulose and on impregnated cellulose and alumina layers with 1-propanol as the organic component of the mobile phase. Each peptide showed a support matrix effect: their RM values first decreased to a minimum, then increased with increasing 1-propanol concentration. On cellulose layers only the increasing phase was observed. The retention behaviour of peptides was adequately described with a quadratic or linear function, but the slope value of the linear function had a positive value. The results demonstrate that the support matrix effect can be observed on non-silica supports and it may occur in reversed-phase chromatography in the case of polar solutes and supports with free adsorptive centres on their surfaces. Both the intercept and slope values of the function are needed to describe the lipophilicity of peptides, but the correlation is not strong enough for the determination of the lipophilicity of peptides by RPTLC. Principal component analysis showed that the peptides form distinct clusters on the basis of their retention characteristics: peptides containing a basic amino acid, peptides with a ring structure in the amino acid side-chain and peptides containing uncharged amino acids.  相似文献   

16.

The retention of aliphatic hydrocarbons with polar groups has been compared in respect to the separation selectivity changes in reversed-phase high-performance liquid chromatography with C18 stationary phase type and binary water eluent composed of methanol, acetonitrile, or tetrahydrofuran as modifiers. The changes in separation selectivity when one modifier is replaced by another in the eluent is explained, taking into consideration molecular interactions of the solutes with components of the stationary phase region, i.e., extracted modifier, and ordering of the stationary phase by the modifier.

  相似文献   

17.
Abstract

The influence of ionisation equilibria on the retention behaviour of iodoamino acids and related compounds on micro-particulate octadecylsilica supports has been examined. The chromatographic data for these ionogenic solutes have been discussed in terms of current concepts for reversible solvophobic interactions with the hydrocarbonaceous stationary phase. This treatment permits the conditional effects of the mobile phase composition and pH on solute retention to be assessed and the relationship between the molecular surface area of a solute and its retention to a non polar stationary phase evaluated.  相似文献   

18.
 以稠环芳烃为探针,考察了烷基膦酸改性锆镁复合氧化物材料的反相色谱性能。研究了稠环芳烃类化合物的结构与其保留值的关系,比较了烷基膦酸改性锆镁复合氧化物固定相和十八烷基键合硅胶ZorbaxODS对稠环芳烃异构体的选择性,并对可能的保留机理进行了讨论。以甲醇-水(体积比为75∶25)为流动相,在烷基膦酸改性锆镁复合氧化物固定相上分离了8种稠环芳烃类化合物。  相似文献   

19.
In this work the potential of hydrophilic interaction chromatography (HILIC) is explored for the analysis of tetracycline antibiotics. The choice of the polar stationary phase is first discussed and it is demonstrated that aminopropyl stationary phases lead to higher efficiencies and peak symmetry than bare silica ones. The influence of the composition of the mobile phase is studied next : the concentration of the weaker solvent (acetonitrile), the nature and concentration of the more polar solvent (water or methanol), pH, the nature and ionic strength of the buffer. It is shown that high efficiencies are reached only with a citrate buffer that impairs the interactions with the residual silanol groups whatever the mobile phase pH is. We demonstrate that the citrate buffer strongly interacts with the cationic moiety of the aminopropyl stationary phase and thus reduces the accessibility of silanols. The separation of oxytetracycline, tetracycline and chlortetracycline is achieved in a few minutes at pH 3.5 or 5, with no peak tailing as usually observed in reversed phase liquid chromatography with an opposite elution order when compared with reversed phase liquid chromatography.  相似文献   

20.
The retention of aromatic hydrocarbons with polar groups has been correlated as log k1 versus log k2 for reversed-phase high-performance liquid chromatography systems with different binary aqueous mobile phases containing methanol, acetonitrile or tetrahydrofuran as modifiers. Distinct changes in separation selectivity have been observed between tetrahydrofuran and acetonitrile or methanol systems. Methanol and acetonitrile systems show lower diversity of separation selectivity. The changes in retention and selectivity of aromatic hydrocarbons with various polar groups between any two chromatographic systems with binary aqueous eluents (tetrahydrofuran vs. acetonitrile, tetrahydrofuran vs. methanol and methanol vs. acetonitrile) have been interpreted in terms of molecular interactions of the solute with especially one component of the stationary phase region, i.e. extracted modifier, and stationary phase ordering. The ordering of the stationary phase region caused by modifier type influences the chromatographic selectivity of solutes with different molecular shape.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号