首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到18条相似文献,搜索用时 187 毫秒
1.
建立顶空气相色谱法测定生活饮用水中微量苯系物的方法,各组分的分离度较好.苯、甲苯、乙苯、对二甲苯、间二甲苯、邻二甲苯、异丙苯的检出限分别为0.002、0.004、0.005、0.007、0.007、0.008、0.005 mg/L,样品的平均加标回收率为97.0%~100.8%,测量结果的相对标准偏差不大于5.1%(n=5),该方法可满足水中苯系物的检测要求.  相似文献   

2.
建立了顶空自动进样-气相色谱/质谱联用(HS-GC/MS)同时测定食品接触用润滑油中11种痕量苯系物(苯、甲苯、乙苯、对二甲苯、间二甲苯、邻二甲苯、氯苯、1,3,5-三甲苯、1,2,4-三甲苯、苯乙烯、α-甲基苯乙烯)的方法。在优化的检测条件下,11种苯系物在10~100μg/kg范围内具有良好的线性,检出限为2~5μg/kg,加标回收率为73.8%~100%,RSD为3.3%~9.9%。方法满足食品接触用润滑油中苯系物高通量及痕量检测的要求。  相似文献   

3.
固相微萃取-气相色谱/质谱联用分析室内空气中的苯系物   总被引:1,自引:1,他引:1  
自制了一种固相微萃取采样装置,建立了固相微萃取-气相色谱/质谱(SPME-GC/MS)联用测定室内空气中苯系物的分析方法。方法的线性范围为1~300μg/m3,检出限为0.1~0.3μg/m3,RSD(n=6)3.2%~15%。采用该方法研究了广州市内20户新装修民居中苯、甲苯、乙苯、对二甲苯和1,3,5-三甲苯的含量及分布,并探讨了苯系物的来源。  相似文献   

4.
优化了固体吸附/热解吸-气相色谱法测定室内空气中苯、甲苯、乙苯、对二甲苯、间二甲苯、异丙苯、邻二甲苯和苯乙烯等8种苯系物的方法。结果表明,目标物色谱峰分离度均大于1.5;在10~500 ng范围内,8种苯系物质量与色谱峰面积呈良好的线性,相关系数r为0.999 7~0.999 9;该方法的检出限为0.50~3.48ng,当采气量为2L时,最低检出浓度为0.25×10~(-3)~1.74×10~(-3)mg/m~3,相对标准偏差为1.2%~9.1%(n=6),回收率在94.0%~99.5%之间。该方法分离效果好,灵敏度高,精密度好,结果准确,可用于室内空气中苯系物含量的检测。  相似文献   

5.
建立了吹扫捕集(P&T)/气相色谱-同位素比值质谱(GC/C-IRMS)联用测定水体中痕量苯系物单体碳同位素的方法。优化了吹扫时间、吹扫温度和干吹时间,确定最优吹扫捕集效率,并通过测试不同质量浓度的苯系物水溶液,计算水体中痕量苯系物的检出限。结果表明,在35 ℃下吹扫捕集13 min,干吹时间3 min条件下,水样中苯、甲苯、乙苯、间/对二甲苯、邻二甲苯、苯乙烯、异丙苯的吹扫捕集效率分别为95.0%、90.2%、71.3%、59.1%、69.4%、50.8%和70.1%,7种苯系物单体碳同位素的标准偏差(STD)为0.06‰ ~ 0.29‰。7种苯系物的质量浓度在0.50 ~ 20.00 μg/L范围内与峰面积的线性关系良好,相关系数(r2)为0.998 6 ~ 0.999 5,在各浓度下7种苯系物单体碳同位素值的标准偏差为0.090‰ ~ 0.48‰,进样量及进样方式的差异不会导致碳同位素分馏。水样中苯、甲苯、间/对二甲苯、邻二甲苯和苯乙烯的检出限为1.00 μg/L,乙苯和异丙苯为0.50 μg/L。该方法可以极大提高水体中苯系物单体碳同位素的检出限,结果准确可靠,满足水体中痕量苯系物单体碳同位素分析的需求。  相似文献   

6.
顶空-气相色谱法同时测定饮用水中八种挥发性苯系物   总被引:3,自引:0,他引:3  
曾东宝 《广州化学》2008,33(2):48-53
利用顶空-毛细管柱气相色谱技术对饮用水中的苯、甲苯、乙苯、邻二甲笨、对二甲笨、间二甲笨、异丙苯、苯乙烯的测定方法进行了研究,并对平衡时间、气/液体积比、水中含盐量等影响测定因素进行了探讨,对色谱条件和顶空进样条件进行了优化。该方法选用HP-INNOWAX色谱柱,使一直较难分离的间、对二甲苯得到了很好的分离。对八种苯系物进行了最低检出限、线性、回收率、精密度试验,其平均回收率为97.4%~1063%(n=7),相对标准偏差为2.55%~3.83%(n=7),最低检出限为0.06~0.10μg/L。测定结果表明,该法操作简单,重现性好,灵敏度高,完全可以满足饮用水中挥发性苯系物的测定。  相似文献   

7.
建立了捕集阱顶空-气相色谱检测水中低浓度苯系物的方法。在捕集阱顶空平衡温度70℃,10 min平衡时间,色谱温度70℃(2 min),10℃/min升温至学20℃,保持2 min,载气流量2.5 mL/min的条件下,6种苯系物分离效果良好,在0.16~40μg/L范围内,苯系物浓度与色谱峰面积呈良好的线性关系,相关系数为0.9994~0.9999;使用捕集阱极大地提高了苯系物分析的灵敏度,方法检出限分别为:苯0.025 ng/L、甲苯0.025 ng/L、乙苯0.023 ng/L、对,间二甲苯0.025 ng/L、邻二甲苯0.027 ng/L、异丙苯0.022 ng/L;本法测定苯系物RSD≤5.1%,加标回收率为79.1%~104.9%。本方法应用于自来水中低浓度苯系物的分析,效果良好。  相似文献   

8.
建立顶空-毛细柱气相色谱法测定水中苯、甲苯、乙苯、对二甲苯、间二甲苯、邻二甲苯和苯乙烯7种苯系物的方法。对色谱条件及顶空条件进行了优化,采用自动顶空进样方式,经70℃平衡30 min,用Rtx-Wax毛细管柱分离,使用火焰离子化检测器检测。7种苯系物的质量浓度在10~100μg/L范围内与其对应的色谱峰面积呈线性关系,相关系数在0.999 0~0.999 6之间,方法检出限为0.2~0.9μg/L,7种苯系物的回收率为96.5%~106.5%,测定结果的相对标准偏差为1.0%~2.2%(n=6)。该方法操作简单,重现性好,测定结果准确可靠,检出限满足国家标准要求,可用于水中7种苯系物的检测分析。  相似文献   

9.
建立了气相色谱-质谱法同时测定修正产品中11种苯系物(苯,甲苯,乙苯,对-二甲苯,间-二甲苯,邻-二甲苯,苯乙烯,氯苯,1,3-二氯苯,1,4-二氯苯,1,2-二氯苯)含量的检测技术。试样中苯系物经二甲亚砜萃取,经DBWAX型毛细管色谱柱分离,质谱定量。结果表明:11种苯系物在1.0~20.0 mg/kg范围内呈良好的线性关系,相关系数R20.9996;方法检出限在0.04~0.07 mg/kg之间;回收率为89.1%~101.1%,相对标准偏差(RSD)1.5%~4.4%。方法能够满足对修正产品中11种苯系物的分析要求。  相似文献   

10.
建立顶空气相色谱同时测定水中8种苯系物和溴代苯、对氟溴苯的方法。水样经气液平衡后,用Sepelco Wax 10色谱柱分离,气相色谱FID检测器进行分析。在所建立的最佳实验条件下,苯系物和溴代苯、对氟溴苯得到有效分离。苯系物和溴代苯、对氟溴苯的色谱峰面积分别与其质量浓度呈良好的线性关系,线性相关系数不小于0.999 7。方法的检出限为0.94~2.36μg/L,测定结果的相对标准偏差为1.4%~5.7%(n=6),加标回收率为90.8%~99.1%。该方法灵敏度高,操作简便,干扰少,适用于生活饮用水中8种苯系物和溴代苯、对氟溴苯的同时分析。  相似文献   

11.
建立了气相色谱内标法测定家具白乳胶中苯系物含量的方法。样品中苯系物经甲醇提取、离心,上清液用60 m EN-20色谱柱分离,气相色谱检测,内标法定量。优化条件下苯系物回收率在96.84%~103.86%,相对标准偏差(RSD)为0.79%~2.28%,定量下限2.4~2.9 mg/L。方法操作简单,准确度和精密度较高,是一种检测白乳胶产品中苯系物含量的有效方法。  相似文献   

12.
目的建立检测黏胶剂中苯系物的方法。方法用顶空直接进样气相色谱法测定黏胶剂中的苯、甲苯、乙苯、对二甲苯、间二甲苯、邻二甲苯以及苯乙烯7种组分,对气相色谱柱、顶空加热温度以及顶空提取时间进行了讨论。结果对苯乙烯等7种被测组分的检测限均小于5mg/kg,7种组分在毛细管柱中能够很好的分离,回收率范围为81%~94%,RSD为5%~10%,具有操作简单、快速等特点。结论能够满足对黏胶剂中苯系物测定的分析要求。  相似文献   

13.
The graphene oxide (GO) and the magnesium–aluminium bimetallic hydroxides composite (GO/Mg-Al-LDH) was used as a solid-phase extractant for determination of toluene, ethylbenzene, p-xylene, m-xylene, o-xylene, 1,3,5-trimethylbenzene and 1,2,4-trimethylbenzene in wastewater by gas chromatography-mass spectrometry analytical method. When the amount of solid-phase extractant was 1.5 g, the extraction time was 6 min, and the elution with 2 mL of chloroform for 3 min, seven monoaromatic hydrocarbons (MAHCs) in 500 mL of water sample can be well extracted and separated. Under the optimised experimental conditions, the mass concentration of each component in the range of 0.01–5 ng/mL has a good linear relationship with the peak area, the coefficients of determination are all greater than 0.995. The relative standard deviation (n = 5) and the method detection limit range are 2.9–7.1% and 0.0005–0.005 ng/mL, respectively. The seven of MAHCs in Dongfengqu River and laboratory wastewater of Chengdu University of Technology can be effectively detected, the recovery rate and the relative standard deviation (n = 5) are 83.0–110.0% and 3.7–9.4%, respectively. For the first time, the GO/Mg-Al-LDH composite was used as a solid-phase extraction material, and seven MAHCs in water were successfully determined by GC-MS. The detection method is established with low detection limit and high reproducibility which can meet the measurement requirements of trace MAHCs in wastewater.  相似文献   

14.
Compound-specific isotope analysis (CSIA) has been established as a useful tool in the field of environmental science, in particular in the assessment of contaminated sites. What limits the use of gas chromatography/isotope ratio mass spectrometry (GC/IRMS) is the low sensitivity of the method compared with GC/MS analysis; however, the development of suitable extraction and enrichment techniques for important groundwater contaminants will extend the fields of application for GC/IRMS. So far, purge and trap (P&T) is the most effective, known preconcentration technique for on-line CSIA with the lowest reported method detection limits (MDLs in the low microg/L range). With the goal of improving the sensitivity of a fully automated GC/IRMS analysis method, a commercially available P&T system was modified. The method was evaluated for ten monoaromatic compounds (benzene, toluene, para-xylene, ethylbenzene, propylbenzene, isopropylbenzene, 1,2,3-trimethylbenzene, 1,2,4-trimethylbenzene, 1,3,5-trimethylbenzene, fluorobenzene) and ten halogenated volatile organic compounds (VOCs) (dichloromethane, cis-1,2-dichloroethene, trans-1,2-dichloroethene, carbon tetrachloride, chloroform, 1,2-dichloroethane, trichloroethene, tetrachlorethene, 1,2-dibromoethane, bromoform). The influence of method parameters, including purge gas flow rates and purge times, on delta13C values of target compounds was evaluated. The P&T method showed good reproducibility, high linearity and small isotopic fractionation. MDLs were determined by consecutive calculation of the delta13C mean values. The last concentration for which the delta13C value was within this iterative interval and for which the standard deviation was lower than +/-0.5 per thousand for triplicate measurements was defined as the MDL. MDLs for monoaromatic compounds between 0.07 and 0.35 microg/L are the lowest values reported so far for continuous-flow isotope ratio measurements using an automated system. MDLs for halogenated hydrocarbons were between 0.76 and 27 microg/L. The environmental applicability of the P&T-GC/IRMS method in the low-microg/L range was demonstrated in a case study on groundwater samples from a former military air field contaminated with VOCs.  相似文献   

15.
建立双柱串联–便携式气相色谱测法定室内空气中苯系物的方法。利用仪器内部自带的Tenax吸附剂在0.5 L/min流量下采集空气样品100 s,然后仪器迅速升温至400℃左右,对吸附剂进行热解吸进样,以微亚离子检测器(MAID)对室内空气中7种苯系物进行测定。结果表明,色谱条件为MXT–200/MXT–WAX金属毛细管柱串联色谱柱,柱温90℃,柱压103 425 Pa时,分离效果最好,且运行时间短。各组分在19.26~306.7μg/m~3范围内与色谱峰面积的平方根线性关系良好,相关系数r大于0.995。方法检出限为6.40~15.9μg/m~3,空白加标回收率为92%~114%,测定结果的相对标准偏差为6.1%~13.7%(n=6)。采用双柱串联便携式气相色谱法测定室内空气中苯系物具有快速、准确、方便等优点。  相似文献   

16.
以核桃壳为原料,经过碳化、KOH活化, 制备了高比表面积活性炭,通过三甲基氧基苯基硅烷对活性炭表面进行改性,制得苯基键合高比表面积活性炭吸附材料.通过氮气吸附法测定了苯基键合活性炭的比表面积及孔径分布;采用红外光谱、X射线光电子能谱、X射线粉末衍射技术对苯基键合活性炭的有机官能团、表面元素的化学环境及晶体结构进行了表征.将该吸附材料制成采样管,吸附空气中的挥发性有机物,二硫化碳解吸后使用气相色谱进行分析.考察了苯基键合活性炭对乙醇、丙酮、正己烷、乙酸乙酯、四氢呋喃、1,2-二氯乙烷和苯共7种挥发性有机化合物(VOCs)的吸附性能,饱和吸附量在129~216 mg/g之间;在0.05~ 2.50 mg/mL范围内,7种组分的峰高与浓度呈良好的线性关系,检出限在0.92~3.60 mg/m3之间.  相似文献   

17.
建立了GC-MS/FID测定环境空气中57种臭氧前体物的分析方法.优化三级冷阱捕集温度、三级冷阱解析温度、初始柱温、毛细管色谱柱等实验条件.优化条件为:采用硅烷化的苏玛罐采集环境空气,目标组分经三级冷阱在-180℃低温浓缩富集,80℃解析,初始柱温为15℃,结合中心切割技术,将乙烷、乙烯、乙炔、丙烷、丙烯切割至TG-B...  相似文献   

18.
采用顶空毛细管柱GC–MS法测定饮用水中卤代烃、苯系物、氯苯等15种挥发性有机物。色谱柱为DB–624石英毛细管柱(60 m×0.25 mm,1.8μm),程序升温,直接进样顶空毛细管柱气质联用法同时测定饮用水中15种挥发性有机物。该方法具有良好的线性,线性相关系数均大于0.996。方法的检出限为0.10~0.22μg/L。15种挥发性有机物的平均回收率在94%~103%之间,测定结果的相对标准差为2.9%~6.7%(n=7)。该方法简便、快速,检测结果均能满足GB 5749–2006检测要求。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号