 共查询到20条相似文献,搜索用时 31 毫秒
1.
The purpose of this study was to assess the benefits of a 3 T scanner and an eight-channel phased-array head coil for acquiring three-dimensional PRESS (Point REsolved Spectral Selection) proton (H-1) magnetic resonance spectroscopic imaging (MRSI) data from the brains of volunteers and patients with brain tumors relative to previous studies that used a 1.5 T scanner and a quadrature head coil. Issues that were of concern included differences in chemical shift artifacts, line broadening due to increased susceptibility at higher field strengths, changes in relaxation times and the increased complexity of the postprocessing software due to the need for combining signals from the multichannel data. Simulated and phantom spectra showed that very selective suppression pulses with a thickness of 40 mm and an overpress factor of at least 1.2 are needed to reduce chemical shift artifact and lipid contamination at higher field strengths. Spectral data from a phantom and those from six volunteers demonstrated that the signal-to-noise ratio (SNR) in the eight-channel coil was more than 50% higher than that in the quadrature head coil. For healthy volunteers and eight patients with brain tumors, the SNR at 3 T with the eight-channel coil was on average 1.5 times higher relative to the eight-channel coil at 1.5 T in voxels from normal-appearing brains. In combination with the effect of a higher field strength, the use of the eight-channel coil was able to provide an increase in the SNR of more than 2.33 times the corresponding acquisition at 1.5 T with a quadrature head coil. This is expected to be critical for clinical applications of MRSI in patients with brain tumors because it can be used to either decrease acquisition time or improve spatial resolution.  相似文献   

2.
In this work, computational methods were utilized to optimize the field produced by the transverse electromagnetic (TEM) resonator in the presence of the human head at 8 Tesla. Optimization was achieved through the use of the classical finite difference time domain (FDTD) method and a TEM resonator loaded with an anatomically detailed human head model with a resolution of 2 mm × 2 mm × 2 mm. The head model was developed from 3D MR images. To account for the electromagnetic interactions between the coil and the tissue, the coil and the head were treated as a single system at all the steps of the model including, numerical tuning and excitation. In addition to 2, 3, 4, 6, and 10-port excitations, an antenna array concept was utilized by driving all the possible ports (24) of a 24-strut TEM resonator. The results show that significant improvement in the circularly polarized component of the transverse magnetic field could be obtained when using multiple ports and variable phase and fixed magnitude, or variable phase and variable magnitude excitations.  相似文献   

3.
A three-dimensional finite difference time domain model was developed where the high pass birdcage coil and the imaged object are analysed as a single unit. A study was performed comparing linear, conventional quadrature, and four-port excitation at 64 MHz and 200 MHz for different coil loadings, namely muscle phantoms and an anatomically detailed human head model. A phase array concept was utilized to excite the birdcage coil in four ports. Two phase conditions were analyzed, the simple fixed phase and the variable phase. At 200 MHz, compared to the conventional quadrature drive, the four-port drive reduces the effects of the tissue-coil interactions leading to more uniform currents on the coil legs and consequently to a better B(1) field homogeneity. Also at 200 MHz, driving the coil in four ports provides an SAR distribution with peak values that are significantly less than those with linear or quadrature excitations.  相似文献   

4.
An actively detunable planar quadrature surface coil for human body imaging at 4 T has been constructed and compared with a conventional linear surface coil. The coil could be used as a transmit/receive or a receive-only device in combination with a volume transmit coil. Transmission, reception profiles and the corresponding images acquired with each coil, as well as with both individual modes of the quadrature coil, are presented. Data collected using a tissue equivalent loaded phantom recorded with the linear surface coil demonstrated significant intensity distortions due to RF penetration artifact. The quadrature surface coil, on the other hand, provided compensation of the artifact, separately in its transmission and reception profiles as well as in the resultant images. Substantial sensitivity gain was also observed for the quadrature coil compared to the linear device. Significant advantages of using the quadrature surface coil over the linear device at 4 T have, therefore, been demonstrated.  相似文献   

5.
A complete time-dependent physics theory of symmetric unperturbed driven hybrid birdcage resonator was developed for general application. In particular, the theory can be applied for radiofrequency (RF) coil engineering, computer simulations of coil-sample interaction, etc. Explicit time dependence is evaluated for different forms of driving voltage. The major steps of the solution development are shown and appropriate explanations are given. Green's functions and spectral density formula were developed for any form of periodic driving voltage. The concept of distributed power losses based on transmission line theory is developed for evaluation of local losses of a coil. Three major types of power losses are estimated as equivalent series resistances in the circuit of the birdcage resonator. Values of generated resistances in legs and end-rings are estimated. An application of the theory is shown for many practical cases. Experimental curve of B1 field polarization dependence is measured for eight-sections birdcage coil. It was shown that the steady-state driven resonance frequencies do not depend on damping factor unlike the free oscillation (transient) frequencies. An equivalent active resistance is generated due to interaction of RF electromagnetic field with a sample. Resistance of the conductor (enhanced by skin effect), Eddy currents and dielectric losses are the major types of losses which contribute to the values of generated resistances. A biomedical sample for magnetic resonance imaging and spectroscopy is the source of the both Eddy current and dielectric losses of a coil. As demonstrated by the theory, Eddy current loss is the major effect of coil shielding.  相似文献   

6.
Deterioration of radiofrequency (RF) inhomogeneity with increasing static magnetic field in magnetic resonance imaging (MRI) is one of the fundamental challenges preventing their clinical rendition and posing safety hazards. Variation in RF coil designs could help redistribute RF energy absorption over the imaged object. This work is intended to determine experimentally the difference in RF heating produced within a human head phantom by in situ measurement of RF inhomogeneity as a function of coil design utilized at 8 T. The heating patterns of 1/4 wavelength (long) and 1/8 wavelength 11-cm (short) transverse electromagnetic (TEM) coils loaded with a homogeneous human head phantom at 340 MHz were evaluated. In addition, different transmit/receive (T/R) configurations were used in search for the possibility of "hot-spot" formation. Fluoroptic thermometry was used to measure temperatures in multiple positions in a head phantom made of ground turkey breast for RF powers corresponding to a specific absorption rate (SAR) of 4.0 W/kg for 10 min. Numerical simulations were performed to study the general RF power deposition patterns in phantoms at 340 MHz including the effects of field polarization. The temperature increases varied from 0 to 0.8 degrees C for the long RF coil, while the short RF coil produced a maximum temperature change of 0.5 degrees C. Similar to ultra high-field electromagnetic simulations, these measurements revealed low peripheral and high deep-tissue heating at 8 T. The findings indicated that the largest temperature changes for both cases were less than 1 degrees C. While these results showed an increase in localized heating due to RF pulses at 8 T, they highlight that RF inhomogeneity could be redistributed using different RF coil designs through which the hot spots could be made cooler.  相似文献   

7.
A quadrature transmit/receive birdcage coil was optimized for squirrel monkey functional imaging at the high field of 9.4 T. The coil length was chosen to gain maximum coil efficiency/signal-to-noise ratio (SNR) and meanwhile provide enough homogenous RF field in the whole brain area. Based on the numerical simulation results, a 16-rung high-pass birdcage coil with the optimal length of 9 cm was constructed and evaluated on phantom and in vivo experiments. Compared to a general-purpose non-optimized coil, it exhibits approximately 25% in vivo SNR improvement. In addition to the volume coil, details about how to design and construct the associated animal preparation system were provided.  相似文献   

8.
A surface coil for MRI was designed and built based on the principles of the petal resonator proposed by Mansfield [J Phys D Appl Phys 21 (1988) 1643]. This resonator coil design was named the petal resonator surface (PERES) coil and is composed of an eight-petal coil array and a central circular coil. A minimum separation of three times the petal coil radius is necessary to significantly decrease the mutual inductance. An analytical function for the PERES Signal-to-noise ratio (SNR) is obtained based on the quasistatic method. Theoretical plots of SNR enhancement yielded 26% and 35% more SNR over the circular coil and phased-array coils. Imaging experiments were first performed using a spectroscopy phantom on a 1.5-T commercial imager. Subsequently, brain images of healthy volunteers were obtained. Clinical MR imager compatibility allows this resonator coil to be used with conventional pulse sequences and imaging protocols. This coil design offers a new alternative to existing surface coils because it significantly increases the SNR.  相似文献   

9.
While magnetic resonance images essentially contain a map of the both circularly polarized components of the RF transverse magnetic fields (B(1) field), the thermal heat and electromagnetic power deposition is generated by the associated electric fields. Measurement of electric field distributions/intensities across a sample yields an indirect indication of possible cause of heating within the sample and potentially enables the detection of "hot spots," which can be present within inhomogeneous radiofrequency (RF) fields, such as the case with magnetic resonance imaging at high field strength. As a result, establishing a valid technique for direct measurements of the electric field and its correlation, obtained using computational electromagnetics, is essential in assessing (1) the safety of the RF coil designs and (2) the validity of the calculations. In this work, a probe was built and used to measure the transverse electric field (E(1) field) distributions within an empty 8 T (tuned to 340 MHz) RF head coil and within a saline water phantom loaded in the same coil. The measured E(1) field distributions were favorably compared to the distributions obtained utilizing a finite difference time domain in-house package.  相似文献   

10.
A phase-unwrapping algorithm, based on the method of moments, is introduced in this work. The proposed algorithm expands the phase map in terms of a two-dimensional Chebyshev series. The expansion coefficients are calculated by exploiting the orthogonality of Chebyshev polynomials of the first kind. The performance of the proposed phase-unwrapping algorithm is tested on a synthetic phase map and experimental phase maps of a uniform phantom, a human brain and a mouse torso, all acquired from 3-T magnetic resonance (MR) scanners. To impose additional burdens on the algorithm, we introduced magnetic field inhomogeneities to the phantom and human brain data by an external gradient coil. The proposed phase-unwrapping algorithm is found to perform well on the phantom data set in a low signal-to-noise ratio (SNR) environment and on the synthetic data set. The proposed algorithm is also found to perform well in in vivo data sets of the human brain and mouse torso. Results obtained from the in vivo MR data sets show that the proposed algorithm produced unwrapped phase maps that are nearly identical to those produced by a widely used phase-unwrapping algorithm, PRELUDE 2D in the fMRI Software Library.  相似文献   

11.
This paper evaluates a new, low-frequency finite-difference time-domain method applied to the problem of induced E-fields/eddy currents in the human body resulting from the pulsed magnetic field gradients in MRI. In this algorithm, a distributed equivalent magnetic current is proposed as the electromagnetic source and is obtained by quasistatic calculation of the empty coil's vector potential or measurements therein. This technique circumvents the discretization of complicated gradient coil geometries into a mesh of Yee cells, and thereby enables any type of gradient coil modelling or other complex low frequency sources. The proposed method has been verified against an example with an analytical solution. Results are presented showing the spatial distribution of gradient-induced electric fields in a multi-layered spherical phantom model and a complete body model.  相似文献   

12.
The four-ring birdcage resonator, a new class of dual-tuned birdeage resonators, is described. We report two configurations of the coil: the low-pass, high-pass (LP-HP) and the low-pass, low-pass (LP-LP), both of which can be operated in dual quadrature mode at 1.5 T. As head coils, both configurations exhibit greatly reduced tuning interactions between frequencies, permitting rapid, noniterative tuning. Compared with single-tuned, two-ring birdcage resonators of similar volume, the sensitivity and transmitter efficiencies of the resonators are better than 85% for the proton frequency and the same to within 5% for the phosphorus frequency. Circuit models have been developed to refine coil tuning and aid the calculation of B1 field contour plots. Both configurations have been used for integrated examinations involving acquisition of high-quality 1H images and 1H-decoupled 31P CSI spectra of the human head. A scaled-down version of the LP-LP configuration has been demonstrated for use with the human calf.  相似文献   

13.
Cardiac metabolism assessment with hyperpolarized 13C magnetic resonance spectroscopy in pig models requires the design of dedicated coils capable of providing large field of view with high signal-to-noise ratio (SNR) data. This work presents a comparison between a commercial 13C quadrature birdcage coil and a homebuilt 13C circular coil both designed for hyperpolarized studies of pig heart with a clinical 3T scanner. In particular, the simulation of the two coils is described by developing an SNR model for coil performance prediction and comparison. While coil resistances were calculated from Ohm’s law, the magnetic field patterns and sample-induced resistances were calculated using a numerical finite-difference time-domain algorithm. After the numerical simulation of both coils, the results are presented as SNR-versus-depth profiles using experimental SNR extracted from the [1-13C]acetate phantom chemical shift image and with a comparison of metabolic maps acquired by hyperpolarized [1-13C]pyruvate injected in a pig. The accuracy of the developed SNR models was demonstrated by good agreement between the theoretical and experimental coil SNR-versus-depth profiles.  相似文献   

14.
The presence and diagnosis of radiation damping could have major implications in NMR experiments with hyperpolarised gases, where accurate knowledge of the flip angle is imperative. In this work radiation damping was observed and investigated in a low-pass birdcage resonator (Q=250) with samples of hyperpolarised 3He at 1.5 T. With an initially highly polarised (P=38%) sample of 3He in a spherical cell, the observed FID had a distorted line shape with a spectral line width that was three times that of the same sample in a virtually depolarised state (1 Hz line width for P<1%). Moreover a linear relation between the sample's magnetisation (M0) and the line width of the spectrum was observed which is indicative of radiation damping. With highly polarised samples, significant radiation damping was observed and the effect was a lower than expected rate of depletion of M0 in RF flip angle calibration experiments, which led to significant underestimate of the RF flip angle. To our knowledge this is the first report of radiation damping in a birdcage resonator with samples hyperpolarised or otherwise. Experimental observation of radiation damping could be used as means of measuring coil efficiency as an alternative to the geometrical filling factor (eta) the definition of which is open to question for a birdcage resonator. Estimates of the birdcage filling factor from the measured damping time constants (eta(RD)=0.4%) are compared to those derived from electromagnetic energy ratios (eta(E)=1.6%) and metallic sphere frequency shift methods (eta(fs)=1.4%). These figures are much lower than the simple volume geometrical upper limit of eta(v)=3.7% derived from the ratio of cell volume to total coil volume (shield included). The physical explanation for this shortfall is that the bulk of the magnetic energy stored in the birdcage is spatially distributed predominantly between the rungs and the shield, and not in the coil centre where the sample is placed and where the B1+ field has its highest spatial homogeneity.  相似文献   

15.
廖庆洪  叶杨  李红珍  周南润 《物理学报》2018,67(4):40302-040302
研究了金刚石氮空位中心(NV色心)同时耦合腔场和机械振子系统中声子场的方差压缩动力学特性,分析了金刚石NV色心初态和NV色心与机械振子耦合强度对声子场方差压缩影响.结果发现:可以制备压缩时间长、压缩幅度大的声子场压缩态,其物理原因是机械振子具有最大相干性,并且通过调控NV色心初态以及磁场梯度可以实现对机械振子方差压缩非经典特性的操控,从而在理论上提供了一种调控声子场方差压缩的方式.  相似文献   

16.
In this work, an eight-element by eight-element dual-tuned quadrature volume coil with a mix of capacitor terminated half-wavelength (λ/2) and quarter-wavelength (λ/4) microstrip resonators is proposed for multinuclear magnetic resonance imaging/spectroscopy studies at 7 T. In the proton channel, λ/2 microstrip resonators with capacitive terminations on both ends are employed for operation at higher frequency of 298.1 MHz; in the heteronucleus channel, capacitor-terminated λ/4 resonators, suitable for low frequency operations, are used to meet the low frequency requirement. This mixed structure design is particularly advantageous for high field heteronuclei magnetic resonance applications with large difference in Larmor frequency of the nuclei in question. The proposed design method makes it much easier to perform frequency tuning for heteronucleus channel using a variable capacitor with a practical capacitance range. As an example, a dual-tuned volume coil for (1)H/(13)C mouse spectroscopic imaging was proposed to demonstrate the feasibility of this method. The finite-difference time-domain method is first used to model this dual-tuned volume coil and calculate the B(1) field distributions at two frequencies. Transmission parameters (S(21)) measured between the proton channel and the carbon channel are -50 dB at 75 MHz and -35 dB at 298 MHz, showing the excellent isolation between the two channels at 7 T. The proton image and (13)C FIDCSI image of a corn oil phantom on the axial plane at 7 T demonstrate the feasibility of the proposed method. A preliminary proton image of a mouse on the sagittal plane is also acquired using the proposed dual-tuned volume coil at 7 T, illustrating a fairly uniform B(1) field and sufficient image coverage for imaging in mice.  相似文献   

17.
MRI is proving to be a very useful tool for sodium quantification in animal models of stroke, ischemia, and cancer. In this work, we present the practical design of a dual-frequency RF surface coil that provides (1)H and (23)Na images of the rat head at 4 T. The dual-frequency RF surface coil comprised of a large loop tuned to the (1)H frequency and a smaller co-planar loop tuned to the (23)Na frequency. The mutual coupling between the two loops was eliminated by the use of a trap circuit inserted in the smaller coil. This independent-loop design was versatile since it enabled a separate optimisation of the sensitivity and RF field distributions of the two coils. To allow for an easy extension of this simple double-tuned coil design to other frequencies (nuclei) and dimensions, we describe in detail the practical aspects of the workbench design and MRI testing using a phantom that mimics in vivo conditions. A comparison between our independent-loop, double-tuned coil and a single-tuned (23)Na coil of equal size obtained with a phantom matching in vivo conditions, showed a reduction of the (23)Na sensitivity (about 28 %) because of signal losses in the trap inductance. Typical congruent (1)H and (23)Na rat brain images showing good SNR ((23)Na: brain 7, ventricular cerebrospinal fluid 11) and spatial resolution ((23)Na: 1.25 x 1.25 x 5mm(3)) are also reported. The in vivo SNR values obtained with this coil were comparable to, if not better than, other contemporary designs in the literature.  相似文献   

18.
Neuronal currents produce weak transient magnetic fields, and the hypothesis being investigated here is that the components of these parallel to the B0 field can potentially modulate the MR signal, thus providing a means of direct detection of nerve impulses. A theory for the phase and amplitude changes of the MR signal over time due to an external magnetic field has been developed to predict this modulation. Experimentally, a fast gradient-echo EPI sequence (TR = 158 ms, TE = 32.4 ms) was employed in an attempt to directly detect these neuronal currents in the adult human optic nerve and visual cortex using a 280-mm quadrature head coil at 1.5 T. A symmetrical intravoxel field distribution, which can be plausibly hypothesized for the axonal fields in the optic nerve and visual cortex, would result in phase cancellation within a voxel, and hence, only amplitude changes would be expected. On the other hand, an asymmetrical intravoxel field distribution would produce both phase and amplitude changes. The in vivo magnitude image data sets show a significant nerve firing detection rate of 56%, with zero detection using the phase image data sets. The percentage magnitude signal changes relative to the fully relaxed equilibrium signal fall within a predicted RMS field range of 1.2-2.1 nT in the optic nerve and 0.4-0.6 nT in the visual cortex, according to the hypothesis that the axonal fields create a symmetrical Lorentzian field distribution within the voxel.  相似文献   

19.
A flexible quadrature radiofrequency coil that maximizes the signal-to-noise ratio over the field of view of the human brain has been integrated into a head immobilization and visor system for fMRI at 1.5 T. Head motion is reduced by the visor that incorporates a head clamp and a simple visual sighting system that provides feedback on head position. This system is demonstrated in serial images by correction of deliberate head motions. The sensitivity at the cortical surface of fMRI using blood oxygenation level dependent contrast is increased significantly above that of the commercial rigid volume RF coil under the same acquisition conditions. This improved performance is demonstrated using visual activation and eye movement paradigms.  相似文献   

20.
This work presents new eddy current measurements in pulsed fields. A commercial point pick-up coil is used to detect the induction signal along the radius of Cu and Al samples with cylindrical shape and diameters between 5 and 35 mm. Local eddy current measurements were performed on the surface of conducting materials due to the small dimensions of the coil. A simple electrical circuit, used as a model, is proposed to describe the local eddy current effect in pulsed fields. The proposed model allows to calculate the phase shift angle between the signal proportional to eddy currents and the applied external field in a pulsed field magnetometer.  相似文献   