首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
The use of absorbance and fluorescence spectrometers as liquid chromatography detectors is described. These detectors offer sensitive detection that can also identify the peaks in a chromatogram. Many examples, mainly from the separation of polycyclic aromatic hydrocarbons, are given that show the selectivity and usefulness of these detectors.  相似文献   

2.
The design of a beta-induced fluorescence detector based on a commercially available radioactive source is described. Results obtained with the detector attached to an hplc system operating in both normal and reverse phase modes are presented. The technique of quenched beta-induced fluorescence in normal phase chromatography is also described and some preliminary results presented.  相似文献   

3.
Selectivity of phase system is of primary concern when designing a 2-D separation, as it affects the 2-D system orthogonality and consequently the peak capacity controlling the number of peaks that can be separated in the available 2-D retention space limited by the time of analysis. Possibilities for characterization of LC phase system selectivity with respect to different polar and nonpolar structural units are compared, with special attention to multidimensional samples with various types of repeat groups, such as homopolymers, (co)polymers, fatty acid esters with various acyl lengths and number and position of double bonds, etc. Possibilities of the 2-D LC separations of these and other sample types, including pharmaceuticals, natural phenolic compounds, biopolymers, etc., using various combinations of separation modes are reviewed. Rules for design of comprehensive 2-D LC x LC systems are discussed, with respect to mobile phase compatibility in the two systems and modulation techniques suppressing band broadening connected with the sample fraction transfer from the first to the second dimension. Pitfalls connected with online connection of normal-phase and RP LC systems and their possible practical solutions are addressed and illustrated by practical examples.  相似文献   

4.
A sensitive assay method for tyrosine hydroxylase in rat brain and adrenal medulla by high-performance liquid chromatography with fluorescence detection is described. L-DOPA formed enzymatically from the substrate L-tyrosine and alpha-methyldopa (internal standard), after clean-up with small cartridges of an activated alumina and a cation exchanger, Toyopak IC-SP M, are converted into the corresponding fluorescent compounds by reaction with 1,2-diphenylethylenediamine. The derivatives are separated by reversed-phase chromatography on TSK gel ODS-120T. The detection limit for L-DOPA formed enzymatically is 2 pmol per assay tube.  相似文献   

5.
A detection system based on on-line post-column fluorescence derivatization is described for the determination of N-terminal tyrosine-containing peptides by reversed-phase high-performance liquid chromatography. The peptides are automatically converted into fluorescent derivatives by reaction with hydroxylamine, cobalt (II) and borate after peptide separation on a reversed-phase column (TSKgel ODS-120T) followed by passage through an ultraviolet absorbance detector. The reaction system permits the fluorescence detection at 435 nm (emission) with excitation at 335 nm for N-terminal tyrosine-containing synthetic peptides in as little as picomole amounts. The facile fluorescence detection of N-terminal tyrosine-containing fragments produced from methionine-enkephalin by enzymatic degradation using a rat brain homogenate was achieved by comparison with the ultraviolet absorption detection at 215 nm.  相似文献   

6.
7.
Azaspiracids (AZAs) are an important group of regulated lipophilic biotoxins that cause shellfish poisoning. Currently, the only widely available analytical method for quantitation of AZAs is liquid chromatography-mass spectrometry (LC-MS). Alternative methods for AZA analysis are needed for detailed characterization work required in the preparation of certified reference materials (CRMs) and by laboratories not equipped with LC-MS. Chemical derivatization of the amine and carboxyl groups on AZAs was investigated for the purpose of facilitating analysis by LC with fluorescence detection (FLD). Experiments towards chemical modification of AZA1 at the amine achieved only limited success. Derivatization of the carboxyl group, on the other hand, proved successful using the 9-anthryldiazomethane (ADAM) method previously applied to the okadaic acid (OA) group toxins. Extraction and clean-up methods were investigated for shellfish tissue samples and a post-reaction solid phase extraction procedure was developed for the AZA ADAM derivatives. Chromatographic separations were developed for the LC-FLD analysis of derivatized AZAs alone or in the presence of other derivatized toxins. This new analytical method for analysis of AZAs enabled verification of AZA1-3 concentrations in recently certified reference materials. The method demonstrated good linearity, repeatability and accuracy showing its potential as an alternative to LC-MS for measurement of AZAs.  相似文献   

8.
New highly sensitive and moderately reactive derivatization reagents for hydroxysteroids have been developed. Two derivatization reagents, 1-anthroyl nitrile and 9-anthroyl nitrile, were readily prepared from the corresponding anthracenecarboxylic acid in two steps. The hydroxysteroid was condensed with the anthroyl nitrile in the presence of triethylamine under mild conditions. The resulting ester showed a single peak of the theoretical shap on the chromatogram and provided excellent sensitivity. The detection limit of the C-21 ester formed from cortisol was 10 pg in normal-phase chromatorgraphy.  相似文献   

9.
A method using high-performance liquid chromatography with fluorescence detection was developed for the determination of beta-carboline compounds norharman, harman, norharmol, and harmol in lung. Aqueous derivatization with acetic anhydride was used to facilitate the isolation and separation of the phenolic compounds and to reduce the fluorescence background of the biological samples. Harman was identified and quantitated in rat lung (1.88 +/- 0.55 ng/g) using this method and its identity confirmed by means of gas chromatography-negative-ion chemical ionization mass spectrometry.  相似文献   

10.
Reversed-phase liquid chromatography (RP-LC) retention data for 23 additional solutes have been acquired to further test and evaluate a general relationship from part I: log alpha = log (k/kref) = eta'H(i) + sigma'S(ii) beta'S(iii) + alpha'B(iv) +kappa'C(v) The physico-chemical origin of terms i-v above is examined here by comparing values of (a) the solute parameters of Eq. (1) (eta', sigma', etc.) vs. solute molecular structure, and (b) the column parameters (H, S, etc.) vs. column properties (ligand length and concentration, pore diameter, end-capping). We conclude that terms i-v correspond, respectively, to hydrophobic (i), steric (ii), hydrogen bonding (iii, iv) and ionic (v) interactions between solute and stationary phase. While steric interaction (term ii) is superficially similar to what previously has been defined as "shape selectivity", the role of the solute and column in determining steric selectivity (term ii) appears more complex than previously proposed for "shape selectivity". Similarly, what has previously been called hydrogen bonding between donor solutes and an acceptor group in the stationary phase (term iv) is very likely an oversimplification.  相似文献   

11.
A fluorogenic substrate with an unsymmetrical carbonyl for the sensitive assay of mammalian carbonyl reductase activities, 4-(6-methoxy-2-benzoxazolyl)acetophenone (I), has been prepared. The fluorescence quantum yield of I in acetonitrile is 0.12 at the emission maximum of 448 nm. The corresponding racemic alcohol produced by the chemical reduction of I, (+/-)-sec.-[4-(6-methoxy-2-benzoxazolyl)]phenethyl alcohol (II), exhibits ca. three- to fourteen-fold higher fluorescence at a shorter wavelength emission maximum of 370 nm in conventional solvents. Each enantiomer of II is sufficiently resolved on a chiral cellulose high-performance liquid chromatographic column without derivatization and quantified with high reproducibility. The detection limit for II is 20 fmol per injection at a signal-to-noise ratio of 3. The validity and applicability of I are evaluated with cytosols of mammalian tissues. The optimal pH for metabolic reduction of I in rabbit liver cytosol preparations is 6.2 in the presence of NADPH. The metabolism is proved to be highly stereoselective. The resulting alcohol produced by mammalian tissue preparations, except rabbit kidney, is predominantly of the S-(-)-configuration.  相似文献   

12.
A high performance liquid chromatography (HPLC) method is described for the determination of agmatine, an endogenous neuromodulator. The method involves pre-column derivatization of the sample with a fluorescent tagging reagent, 7-fluoro-4-nitrobenzoxadiazole (NBD-F). The resulting agmatine derivative is stable and can be readily extracted into ethyl acetate at pH 8.5. The extraction enhances the quantification of low level agmatine because it eliminates chromatographic peaks caused by endogenous amino acids. The HPLC separation is carried out on a C8 reversed phase column and completed in less than 10 min. With laser-induced fluorescence (LIF) detection, the detection limit is 5×10−9 M agmatine. Method precision (coefficient of variation) is 5% for agmatine in human plasma at the sub-μM level. This method has been validated by determination of agmatine in biological samples including human plasma and rat brain and stomach tissues.  相似文献   

13.
In an effort to gain insight into the relationship between stationary phase solvation and selectivity, the use of short- and medium-chained-length alcohols (methanol, n-propanol, n-butanol, and n-pentanol) as mobile phase modifiers in reversed-phase liquid chromatography (RPLC) was investigated to determine their impact on chromatographic selectivity. A wide range of mobile phase compositions was evaluated because of the large effect exerted by solvent strength on selectivity. Employing a set of six vanillin compounds as retention probes, evidence is presented to support the view that an increase in the hydrophobicity of the organic modifier used in RPLC can increase the selectivity of the C18 alkyl bonded phase while simultaneously decreasing the retention time of the eluting solutes. Thus, we are presented with an interesting paradox: higher selectivity and shorter retention times, which can be attributed to changes in either solvent selectivity and/or stationary phase solvation by the organic modifier.  相似文献   

14.
In this work we present some applications of near-UV laser-induced fluorescence (LIF) with micro-HPLC (microHPLC) and HPLC. To test the sensitivity of the detection, we used pyrene and aflatoxins, because both of these molecules exhibit native fluorescence. Then we studied catecholamines derivatized with 1,2-diphenylethylenediamine. The results show that we were able to reach better sensitivity levels than previously described in LIF studies. For catecholamines, a 50-fold increase in sensitivity compared to conventional fluorescence was obtained. These results indicate that LIF detection associated with HPLC or microHPLC can be used to detect very low concentrations of substances that can be excited in the near-UV range after labeling at nanomolar concentrations.  相似文献   

15.
Vapour phase chromatography is a highly efficient analytical technique for the separation of gases and volatile liquids. The stationary phase in this percolation process is a liquid supported by an inert solid carrier material of a suitable particle size. The important role played by this liquid in the separation of a mixture into its components is discussed.  相似文献   

16.
17.
A liquid chromatography (LC) method is described for the determination of oxytetracycline (OTC) in farmed Atlantic salmon muscle tissue. The method involves homogenization of salmon tissue, extraction of OTC into Mcllvaine-EDTA buffer, acid precipitation of proteins, cleanup through tandem solid-phase extraction cartridges (Strata-X and aminopropyl), elution with mobile phase containing slightly alkaline buffer and Mg2+, and LC separation with metal-chelate induced fluorescence detection. Salmon tissue was fortified with 0.10, 0.25, 0.50, 0.75, and 1.0 microg/g (ppm) oxytetracycline. Average absolute recoveries were 84, 76, 70, 76, and 85%, respectively, with relative standard deviation (RSD) values all less than 9%. The interassay average recovery was 78%, with a 4.2% RSD. Determination was based on a standard graph using peak areas with standard solutions equivalent to 0.0625, 0.125, 0.25, 0.50, and 1.0 ppm in tissue. A set of 5 matrix controls (unfortified salmon tissue) were also analyzed, in which no OTC was detected. The lowest standard was used as the limit of quantitation.  相似文献   

18.
19.
A method was developed to determine 4-hexylresorcinol in shrimp meat. The procedure is based on extraction of test portions with methanol followed by liquid chromatographic analysis of the extracts, using a reversed-phase column and fluorimetric detection (excitation: 280 nm, and emission: 310 nm). The confidence interval of the recovery in working range of 1.5-2.5 mg/kg was 81.6 +/- 0.8%. The relative standard deviation in the working range was 2.1%. Limits of quantitation and detection were 6.59 and 1.98 ng/mL extract, respectively, corresponding to 0.26 and 0.08 mg/kg in shrimp.  相似文献   

20.
A sensitive and selective high-performance liquid chromatographic method has been developed for the determination of tianeptine (Tia) in tablets. The method is based on derivatization of Tia with 4-chloro-7-nitrobenzofurazan (NBD-CI). A mobile phase consisting of acetonitrile-10 mM orthophosphoric acid (pH 2.5; 77 + 23) was used at a flow rate of 1 mL/min on a C18 column. The Tia-NBD derivative was monitored using a fluorescence detector, with emission set at 520 nm and excitation at 458 nm. Gabapentin was selected as an internal standard. Linear calibration graphs were obtained in the concentration range of 45-300 ng/mL. The lower limit of detection (LOD) was 10 ng/mL at a signal-to-noise ratio of 4. The lower limit of quantitation (LOQ) was 45 ng/mL. The relative standard values for intra- and interday precision were <0.46 and <0.57%, respectively. The recovery of the drug samples ranged between 98.89 and 99.85%. No chromatographic interference from the tablet excipients was found. The proposed method was validated in terms of precision, robustness, recovery, LOD, and LOQ. All the validation parameters were within the acceptance range. The proposed method was applied for the determination of Tia in commercially available tablets. The results were compared with those obtained by an ultraviolet spectrophotometric method using t- and F-tests.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号