共查询到20条相似文献,搜索用时 15 毫秒
1.
《Journal of chromatography. A》1999,830(1):183-189
Capillary electrophoresis (CE) was applied as a fast method of siderophore separation. Siderophores are iron binding and regulating cell products, which facilitate iron transport into cells. A fast and efficient method of siderophore analysis is important for better understanding of the iron pathways in a sea environment or marine organisms. The best results of CE analysis were obtained using free zone CE in 25 mM phosphate buffer at basic pH using a constant voltage of 20 kV. Under these conditions it was possible to detect the presence of siderophores in seawater. 相似文献
2.
《Journal of separation science》2003,26(11):1045-1049
Differences in the surface charges of bacteria can be exploited for their separation by capillary electrophoresis. Because of their low electrophoretic mobility, the separation is not always easy to perform, especially in the presence of the electroosmotic flow. Elimination of electroosmotic flow by capillary wall modification with γ‐(trimethoxysilyl)propyl methacrylate followed by acrylamide bonding permits separation over a distance of 8.5 cm. 相似文献
3.
Summary Four phenothiazines, promethazine, dioxypromethazine, chlorpromazine, and trifluoperazine have been separated by capillary
electrophoresis using N,N,-dimethylformamide (DMF) as separation medium with UV absorbance detection. High voltage and concentrated
buffer were used with small current and low electroosmosis. Good resolution and high column efficiency were obtained. Separation
selectivity in DMF was different from that in water because of the different solvation interactions. The influence of buffer
composition on separation selectivities and electroosmosis were also studied. 相似文献
4.
A. Nilchi M. Edalat M. Taghiof S. Rasouli Garmarodi 《Journal of Analytical Chemistry》2012,67(4):378-385
Due to the importance of application of lanthanides in various industries especially the nuclear ones, and the advantages
of capillary electrophoresis method in separation of metal cations, this research was carried out in order to investigate
the separation potential of lanthanides using capillary electrophoresis via simulation method at laboratory scale. Since the
properties of various types of lanthanides are very similar, the separation of lanthanides using the usual approaches was
not possible. Thus, the separation of lanthanides was devised upon partial, competing complexation in order to differentiate
their properties. Salicylic acid was firstly used as the primary UV-absorbing ligand, whereas formic, acetic, lactic, tartaric
and citric acids, which showed no absorption in UV-spectrum and had weaker complexes in comparison to salicylic acid, were
used as auxiliary ligands. Upon the results of spectrometry, the wave length of 210 nm was selected for detecting lanthanides.
The properties and stability of lanthanides were examined and furthermore acetic and citric acids were selected as auxiliary
ligands. The simulation was carried out with respect to the transport phenomena in the unsteady state. The ion species dissociation
was found to be directly dependent upon the concentration, and was also used in complexation. The results of simulation showed
that the diffusion control of H+ and homogenizing electrical field promoted separation quality. The separation conditions were optimized by using the simulation
results as well as the tests obtained. In order to optimize the experimental conditions, variable factors such as voltage,
injection time, pH, temperature and ionic strength were examined. Also, methanol was used as dissolving modifier as well as
noise reducer on the base line. Sodium nitrate was used as ionic strength controller and sucrose for increasing viscosity
which optimized separation quality. 相似文献
5.
Separation of neutral carbohydrates by capillary electrophoresis 总被引:1,自引:0,他引:1
Susumu Honda 《Journal of chromatography. A》1996,720(1-2):337-351
The basic strategies for analysis of neutral carbohydrates by capillary electrophoresis are summarized. Neutral carbohydrates are dissociated in strong alkali to give anions, hence they can be separated directly by zone electrophoresis based on the difference between their dissociation constants. However, neutral carbohydrates are not electrically charged under normal conditions. Therefore, they should be converted to ions prior to or during analysis. Precapillary introduction of a basic or an acidic group to a neutral carbohydrate gives the derivative positive (in acidic media) or negative (in alkaline media) charge, respectively. The derivatives thus obtained can be separated by zone electrophoresis. Analysis of carbohydrates in a carrier containing an oxyacid salt (such as sodium borate) or an alkaline metal salt (such as calcium acetate) causes in situ conversion to anionic or cationic complexes, respectively, which are separated by zone electrophoresis. The effective uses of electrokinetic chromatography in sodium dodecyl sulfate micelles for hydrophobic derivatives (such as 1-phenyl-3-methyl-5-pyrazolone derivatives) and size-exclusion electrophoresis in gel-packed capillaris for size different oligosaccharides are also discussed. Each separation mode has its inherent method(s) for detection, which are also described here. 相似文献
6.
Palmer ME Smith RF Chambers K Tetler LW 《Rapid communications in mass spectrometry : RCM》2001,15(3):224-231
The use of capillary zone electrophoresis (CZE) and capillary zone electrophoresis/mass spectrometry (CZE/MS) has been demonstrated, in principle, for the separation of nicotine and nicotine metabolites. The buffer system developed for separation and detection by CZE/UV was modified for use in CZE/MS analysis. Several of the metabolites are isobaric and tandem mass spectrometric (MS/MS) techniques have been used to differentiate such analytes. 相似文献
7.
High throughput means to detect and quantify low-frequency mutations (<10(-2) ) in the DNA-coding sequences of human tissues and pathological lesions are required to discover the kinds, numbers, and rates of genetic mutations that (i) confer inherited risk for disease or (ii) arise in somatic tissues as events required for clonal diseases such as cancers and atherosclerotic plaque.While throughput of linear DNA sequencing methods has increased dramatically, such methods are limited by high error rates (>10(-3) ) rendering them unsuitable for the detection of low-frequency risk-conferring mutations among the many neutral mutations carried in the general population or formed in tissue growth and development. In contrast, constant denaturing capillary electrophoresis (CDCE), coupled with high-fidelity PCR, achieved a point mutation detection limit of <10(-5) in exon-sized sequences from human tissue or pooled blood samples. However, increasing CDCE throughput proved difficult due to the need for precise temperature control and the time-consuming optimization steps for each DNA sequence probed. Both of these problems have been solved by the method of cycling temperature capillary electrophoresis (CTCE). The data presented here provide a deeper understanding of the separation principles involved in CTCE and address several elements of a previously presented two-state transport model. 相似文献
8.
The influence of buffer composition and pH on the electrophoretic behavior of diadenosine polyphosphates with a phosphate chain ranging from two to five phosphate groups has been examined. The electrophoretic mobility in carbonate buffer increases according to the number of phosphates, whereas in borate buffer the mobility changes in an irregular way as a function of pH. This finding can be rationalized by a well-known interaction of borate with ribose rings, which modifies the charge and the hydrodynamic radius of each diadenosine polyphosphate in a different way. Our study shows that the best separation of diadenosine polyphosphates can be achieved at the highest pH values of the range examined both in borate and carbonate buffers. 相似文献
9.
D. Kaniansky M. Masár J. Marák V. Madajová F. I. Onuska 《Journal of Radioanalytical and Nuclear Chemistry》1996,208(1):331-350
Separation conditions suitable to a rapid resolution of a group of eight nitrophenols by capillary zone electrophoresis (CZE) were found. Required differences in their effective mobilities were achieved via host-guest complexation of -cyclodextrin combined with intermolecular interactions involved by polyvinylpyrrolidone. When both additives were present in the carrier electrolyte at pH=9.1 nitrophenols could be separated in the column of a, 300 m I.D. and 180 mm in the length within 8–9 minutes. It is shown that the column of such an I.D. providing enhanced sample load capacity, can operate with high separation efficiencies as maintaining zone dispersions due to Joule heating on a tolerable level. CZE on-line coupled with isotachophoretic sample pretreatment is shown to provide the concentration limits of detection at low ppb concentrations by using an on-column photometric detector operating at 254 and 405 nm detection wavelengths. 相似文献
10.
A number of experimental parameters have been optimized for the separation of 26 metal ions, including alkali, alkaline earth, transition and lanthanide metal ions. Experimental parameters that were evaluated included nature of indirect-detection reagent, pH of electrolyte, concentration of complexing agent and nature of the surface of the capillary; unbonded and C1 and C18 bonded phases were studied. In addition the effect of internal diameter on linearity and signal-to-noise ratio was examined, and separation efficiency was determined for a variety of experimental conditions. Detection limits (signal-to-noise RATIO = 3) were ca. 1 μg/ml for the lanthanides, ca. 0.6 μg/ml for transition and alkaline earth ions and ca. 0.1–0.8 μg/ml for alkali metal ions. The average relative standard deviations of were 3.7, 5.1 and 2.5% on unbonded, C1 and C18 capillaries, respectively. Whereas conventional regression analysis suggested that the calibration curves were linear over the range of 1·10−5 to 4·10−4 mol/l, sensitivity plots showed that the results were actually linear to within 6% only over the range of 2.5·10−5 to 4·10−4 mol/l. 相似文献
11.
Giovanni Dinelli Alberto Vicari Alessandra Bonetti 《Journal of chromatography. A》1995,700(1-2):195-200
The potential of capillary electrophoresis (CE) for the separation and detection of the metabolites of nine sulfonylurea herbicides in aqueous solution was evaluated. A relationship between the structure of the sulfonylureas tested and the metabolites formed was found: the non-o-benzene-substituted sulfonylurea rimsulfuron gave only one metabolite, whereas the other eight, o-benzene-substituted, sulfonylureas gave 4–6 metabolites. CE was confirmed to be a very efficient separation technique, suitable for the determination of sulfonylurea herbicides and their metabolites formed during hydrolysis. 相似文献
12.
CZE with UV-absorption detection has been used for the separation and determination of enkephalin-related peptides. The experimental conditions, such as pH and concentration of running buffer, applied voltage, injection method, and time, were investigated in detail. Excellent separation efficiency could be obtained for ten enkephalin-related peptides with a 50 microm (ID) x 58 cm capillary using sodium dihydrogen phosphate as the running buffer (pH 3.11) when 20 kV of applied voltage was used. The concentration detection limits were found to be in the range of 0.31-1.94 microg/mL (defined as S/N = 3). The proposed method has been applied to analyze the spiked cerebrospinal fluid (CSF) sample, and the results showed that CZE is a powerful technique for separation and detection of the above biological peptides. 相似文献
13.
Suntornsuk L 《Electrophoresis》2001,22(1):139-143
This study demonstrates the separation of cold medicine ingredients (e.g., phenylpropanolamine, dextromethorphan, chlorpheniramine maleate, and paracetamol) by capillary zone electrophoresis and micellar electrokinetic chromatography. Factors affecting their separations were the buffer pH and the concentrations of buffer, surfactant and organic modifiers. Optimum results were obtained with a 10 mM sodium dihydrogen-phosphate-sodium tetraborate buffer containing 50 mM sodium dodecyl sulfate (SDS) and 5% methanol (MeOH), pH 9.0. The carrier electrolyte gave a baseline separation of phenylpropanolamine, dextromethorphan, chlorpheniramine maleate, and paracetamol with a resolution of 1.2, and the total migration time was 11.38 min. 相似文献
14.
Separation of derivatized carbohydrates by co-electroosmotic capillary electrophoresis 总被引:2,自引:0,他引:2
Summary The separation of derivatized carbohydrates has been performed by co-electroosmotic capillary electrophoresis. Derivatization
was performed by reductive amination of the carbohydrates with ethylp-aminobenzoate or withp-aminobenzonitrile. Separation selectivity is optimized using buffer electrolytes containing high concentrations of borate,
organic solvents, and mixtures thereof; this enabled separation of the carbohydrate derivatives then direct UV detection.
Co-directional migration of the anionic analytes with the electroosmotic flow was achieved by adding a cationic polyer (hexadimethrine
bromide, HDB) to the electrolyte. With this method it is possible to determine specific carbohydrates, such as arabinose,
mannose, and glucose, which are difficult to separate by other CE methods. The applicability of the method is demonstrated
for the analysis of plant hydrolyzates 相似文献
15.
Hsiu-Li Su Wan-Chun KaoCheng-yu Lee Shih-Ching ChuangYou-Zung Hsieh 《Journal of chromatography. A》2010,1217(26):4471-4475
In this study, nonaqueous capillary electrophoresis (NACE) was used to separate three open-cage fullerenes. Trifluoroacetic acid (TFA) was used as the nonaqueous background electrolyte to change the analytes’ mobilities. The selectivity and separation efficiency were critically affected by the nature of the buffer system, the choice of organic solvent, and the concentrations of TFA and sodium acetate (NaOAc) in the background electrolyte. The optimized separation occurred using 200 mM TFA/20 mM NaOAc in MeOH/acetonitrile (10:90, v/v), providing highly efficient baseline separation of the open-cage fullerenes within 5 min. The migration time repeatability for the three analytes was less than 1% (relative standard deviation). Thus, NACE is a rapid, useful alternative to high-performance liquid chromatography for the separation of open-cage fullerenes. 相似文献
16.
Capillary electrophoresis (CE) has recently emerged as a highly promising technique consuming an extremely small amount of sample and capable of the rapid, high-resolution separation, characterization, and quantitation of analytes. CE has been used for the separation of biopolymers, including acidic carbohydrates. Since CE is basically an analytical method for ions, acidic carbohydrates that give anions in weakly acid, neutral, or alkaline media are often the direct objects of this method. The scope of this review is limited to the use of CE for the analysis of carbohydrates containing carboxylate, sulfate, and phosphate groups as well as neutral carbohydrates that have been derivatized to incorporate strongly acidic functionality, such as sulfonate groups. 相似文献
17.
Summary A new buffer system for the separation of cations with capillary electrophoresis using indirect UV-detection is described. p-Aminopyridine can be used in the wide pH-range between 3 and 10. High-speed separations of positively charged non-UV absorbing ions are possible. Separation of ions with similar mobilities can be achieved by the addition of complexation reagents. The separation of potassium and ammonium is possible either with the addition of crown ether or at high pH-values. Transition metals can be separated by adding 2-hydroxybutyric acid to the buffer.Dedicated to Professor Dr. Wilhelm Fresenius on the occasion of his 80th birthday 相似文献
18.
We describe a method for the simultaneous determination of the five fibrinopeptide forms derived from the thrombin-promoted activation of human fibrinogen by capillary zone electrophoresis (CZE). The fibrinopeptide mixture was first desalted by a solid-phase extraction (SPE) step. The analysis was performed in reversed polarity in a highly cross-linked polyethylene glycol (PEG)-coated capillary with UV-light absorption detection at 200 nm. Several parameters including buffer concentration and pH, presence of an organic modifier, temperature, and applied voltage, have been tested. The best separations were obtained within 20 min, utilizing a 20 mM sodium phosphate buffer without organic modifier, in the narrow 6.1-6.2 pH range, at 25 degrees C, with an applied voltage of 20 kV. Quantitative analysis is made possible by the use of sheep fibrinopeptide A as an internal standard to correct for both extraction and injection errors. 相似文献
19.
Cañada-Cañada F Kasselouri A Prognon P Maillard P Grierson DS Descroix S Taverna M 《Journal of chromatography. A》2005,1068(1):123-130
The nonaqueous capillary electrophoresis mode which includes a preconcentration step based on a transient pseudo-isotachophoresis to the simultaneous separation of seven glucoconjugated and hydroxylated porphyrins and chlorins, exhibiting very close structures, is reported. A high methanol content, of the buffer solution, was necessary in order to prevent self-assembly of the compounds and to enhance their solubility during separation. With the addition of 66% (v/v) methanol and 1% (w/v) NaCl in the aqueous sample solution, large volumes could be injected (44% capillary volume) without a loss in resolution. Sensitivity of detection was therefore improved by a 100-fold factor with regard to the method employing normal injection (2% capillary volume). Optimum electrophoretic conditions, in terms of sensitivity and performance, were obtained by using 20 mM phosphoric acid buffer, pH 2.2 and 50% methanol. The method was validated and applied to qualitative analysis of glucoconjugates in serum samples. 相似文献
20.
A simple and rapid capillary electrophoresis method has been developed for the quantitative analysis of three active compounds: (3R)-7,2'-dihydroxy-3',4'-dimethoxy-isoflavan, kaempferol, and quercetin in Ixeridium gracile. The buffer solution used in this method is 20 mmol/L borate at pH 9.5. The effects of pH value, borate concentration, and applied voltage on migration behavior are systematically investigated. Regression equations reveal good linear relationships (correlation coefficients: 0.9986, 0.9997, and 0.9999) between the peak area of each compound and its concentration. The relative standard deviations of the migration time and peak area are less 1.12% and 3.11% (intraday), and 1.43% and 3.52% (interday), respectively, under the optimized separation conditions. The contents of the three flavonoids in I. gracile are successfully determined within 7.8 min, with satisfactory repeatability and recovery. 相似文献