首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A sensitive preconcentration methodology for Cd determination at trace levels in water samples was developed in this work. 1-Butyl-3-methylimidazolium hexafluorophosphate ([C4MIM][PF6]) room temperature ionic liquid (RTIL) was successfully used for Cd preconcentration, as cadmium-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol complex [Cd-5-Br-PADAP]. Subsequently, Cd was back-extracted from the RTIL phase with 500 μL of 0.5 mol L−1 nitric acid and determined by electrothermal atomic absorption spectrometry (ETAAS). A preconcentration factor of 40 was achieved with 20 mL of sample. The limit of detection (LOD) obtained under optimum conditions was 3 ng L−1 and the relative standard deviation (R.S.D.) for 10 replicates at 1 μg L−1 Cd2+ concentration level was 3.5%, calculated at peak heights. The calibration graph was linear from concentration levels near the detection limits up to at least 5 μg L−1. A correlation coefficient of 0.9997 was achieved. Validation of the methodology was performed by standard addition method and analysis of certified reference material (CRM). The method was successfully applied to the determination of Cd in river and tap water samples.  相似文献   

2.
A novel on-line preconcentration method based on liquid-liquid (L-L) extraction with room temperature ionic liquids (RTILs) coupled to flame atomic absorption spectrometry (FAAS) was developed for cadmium determination in plastic food packaging materials. The methodology is based on the complexation of Cd with 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP) reagent after sample digestion followed by extraction of the complex with the RTIL 1-butyl-3-methylimidazolium hexafluorophosphate ([C4mim][PF6]). The mixture was loaded into a flow injection analysis (FIA) manifold and the RTIL rich-phase was retained in a microcolumn filled with silica gel. The RTIL rich-phase was then eluted directly into FAAS. A enhancement factor of 35 was achieved with 20 mL of sample. The limit of detection (LOD), obtained as IUPAC recommendation, was 6 ng g−1 and the relative standard deviation (R.S.D.) for 10 replicates at 10 μg L−1 Cd concentration level was 3.9%, calculated at the peak heights. The calibration graph was linear and a correlation coefficient of 0.9998 was achieved. The accuracy of the method was evaluated by both a recovery study and comparison of results with direct determination by electrothermal atomic absorption spectrometry (ETAAS). The method was successfully applied for Cd determination in plastic food packaging materials and Cd concentrations found were in the range of 0.04-10.4 μg g−1.  相似文献   

3.
Dichlorodiphenyltrichloroethane (DDT) and its main metabolites are important environmental pollutants and have been in the focusing center. It is of great value to develop simple, rapid, sensitive and easy to operate method for monitoring them. Present work established a novel temperature controlled ionic liquid dispersive liquid phase microextraction method in combination with high performance liquid chromatography for the enrichment and determination of DDT and its metabolites. Proposed method used only ionic liquid 1-hexyl-3-methylimidazolium hexafluorophosphate ([C6MIM][PF6]) for the enrichment and overcame the demerits of conventional single drop liquid phase microextraction and dispersive liquid-liquid microextraction. Temperature has two functions here, one is to promote the dispersing of ionic liquid into the solution and forming infinitesimal micro-drop and increasing the chance of the analytes extracted into ionic liquid phase, and the other one is to perform phase-separation. A series of factors that would affect the extraction performance was systematically investigated and optimized. The experimental results indicated that the detection limits obtained for p,p′-DDD, p,p′-DDT, o,p′-DDT and p,p′-DDE were 0.24, 0.24, 0.45, 0.24 ng mL−1, respectively. The linear ranges for them were from 1.0 to 100 ng mL−1, and the precisions were between 3.8% and 6.7% (n = 6). The proposed method was validated with four real-world samples and excellent results were achieved.  相似文献   

4.
Headspace liquid-phase microextraction (HS-LPME) has been applied to efficient enrichment of phenols such as 2-nitrophenol, 4-chlorophenol, 2,4-dichlorophenol, and 2-naphthol from water samples based on 1-butyl-3-methylimidazolium hexafluorophosphate ([C4MIM][PF6]) as an extractant. Some parameters that may influence HS-LPME were investigated. The linear range was in the range of 0.5-100 microg/L, and the enrichment factors and repeatability (RSD, n = 6) of the proposed method were in the range of 17.2-160.7 and 5.4-8.9%, respectively. The detection limit for each analyte ranged from 0.3 to 0.5 microg/L. Complex matrices of environmental water samples had a small effect on the enrichment, and this problem could be resolved by the addition of sodium ethylene diamine tetraacetate (EDTA) into the samples. The spiked recoveries were in the range of 89.4-114.2%. All these facts demonstrated that the proposed method, with merits of low cost, simplicity, and easy operation, would be a competitive alternative procedure for the determination of such compounds at trace level.  相似文献   

5.
He L  Zhang K  Wang C  Luo X  Zhang S 《Journal of chromatography. A》2011,1218(23):3595-3600
An ionic liquid dispersive liquid–liquid microextraction high-performance liquid chromatography (IL-DLLME-HPLC) method for effective enrichment and determination of nitrite ion in water and biological samples was developed. The method was based on the reaction of nitrite ion with p-nitroaniline in the presence of diphenylamine in acid media and IL-DLLME of azo product. The optimization of reaction and extraction conditions, such as kind and concentration of acid, reaction time, volume of reaction solvent, temperature, kind of extraction and dispersive solvent, volume of extraction and dispersive solvent, addition of salt, extraction and centrifugal time were studied. Under the optimal conditions, 1-octyl-3-methylimidazolium bis[(trifluoromethyl)sulfonyl]imide IL-DLLME procedure provided high enrichment factor of 430 and good extraction recovery of 91.7% for nitrite ion. The linearity was observed in the range of 0.4–500.0 μg L−1 with good correlation coefficient (r2 = 0.9996). The relative standard deviations (RSDs) for five replicate measurements varied between 1.5% and 4.8%. The limit of detection of the method (S/N = 3) was 0.05 μg L−1. The interference effect of some anions and cations was also tested. The developed method allowed achieving an excellent enrichment factor, yielding a lower LOD in comparison with other methods. Moreover, the proposed method was able to analyze nitrite ion in water and biological samples with satisfactory recovery ranged from 96.5% to 107.3%.  相似文献   

6.
Room temperature ionic liquids (RTILs) have been used as novel solvents to replace traditional volatile organic solvents in organic synthesis, solvent extraction, and electrochemistry. The hydrophobic character and water immiscibility of certain ionic liquids allow their use in solvent extraction of hydrophobic compounds. In this work, a typical room temperature ionic liquid, 1-butyl-3-methylimidazolium hexafluorophosphate [C4mim][PF6], was used as an alternative solvent to study liquid/liquid extraction of heavy metal ions. Dithizone was employed as a metal chelator to form neutral metal-dithizone complexes with heavy metal ions to extract metal ions from aqueous solution into [C4mim][PF6]. This extraction is possible due to the high distribution ratios of the metal complexes between [C4mim][PF6] and aqueous phase. Since the distribution ratios of metal dithiozonates between [C4mim][PF6] and aqueous phase are strongly pH dependent, the extraction efficiencies of metal complexes can be manipulated by tailoring the pH value of the extraction system. Hence, the extraction, separation, and preconcentraction of heavy metal ions with the biphasic system of [C4mim][PF6] and aqueous phase can be achieved by controlling the pH value of the extraction system. Preliminary results indicate that the use of [C4mim][PF6] as an alternate solvent to replace traditional organic solvents in liquid/liquid extraction of heavy metal ions is very promising.  相似文献   

7.
离子液体顶空液相微萃取富集苯系物   总被引:9,自引:0,他引:9  
以水不互溶的离子液体1-丁基-3-甲基咪唑的六氟磷酸盐作为顶空液相微萃取的萃取剂,能够从水溶液中有效地萃取苯系物。当萃取时间为30min时,富集倍数在19~50之间。  相似文献   

8.
In the present study an innovative tandem ionic liquid-based dispersive microextraction method using an in-syringe air-assisted vesicle system was developed to determine the ultra-trace levels of lead (PbII) and cadmium (CdII) ions in synthetic sweat extract of branded and nonbranded facial cosmetic products. This method is based on injecting 2-amino-3-sulfhydrylpropanoic acid (l -cysteine) (as an eco-friendly chelating agent), hexafluorophosphate ion [PF6] (as an ion pair agent) and 1-hexyl-3-methylimidazolium hexafluorophosphate [HMIM] [PF6] (as an acceptor phase) into the synthetic sweat extract of facial cosmetic products (branded and nonbranded). The acceleration of the dispersion process was carried out by rapid pressure in the syringe through the back-and-forth movement of plunger. The sediment phase was removed following centrifugation, and then hydrophobic complexes of analyte were back-extracted into HNO3 and finally injected into a flame atomic absorption spectrometer. Several factors were systematically optimized. The validity of the methodology was tested by analyzing spiked known standards of both metals in a real sample. The proposed method was applied to the artificial sweat extracts of face makeup products, indicating how much toxic metals from different cosmetics are directly absorbed into skin.  相似文献   

9.
Pei Liang  Linlin Zhang  Ehong Zhao 《Talanta》2010,82(3):993-2983
A novel displacement-dispersive liquid-liquid microextraction method was developed for the selective determination of trace silver in complicated samples by graphite furnace atomic absorption spectrometry. This method involves two steps of dispersive liquid-liquid microextraction (DLLME). Firstly, copper ion reacted with diethyldithiocarbamate (DDTC) to form Cu-DDTC complex and extracted with DLLME procedure using carbon tetrachloride (extraction solvent) and methanol (dispersive solvent); then, the sedimented phase was dispersed into the sample solution containing silver ion with methanol and another DLLME procedure was carried out. Because the stability of Ag-DDTC is larger than that of Cu-DDTC, Ag+ can displace Cu2+ from the pre-extracted Cu-DDTC and thus the preconcentration of Ag+ was achieved. Potential interference from co-existing transition metal ions with lower DDTC complex stability was largely eliminated as they cannot displace Cu2+ from Cu-DDTC complex. The tolerance limits for the co-existing ions were increased by a long way compared with conventional DLLME. Under the optimal conditions, the limit of detection was 20 ng L−1 (3σ) for silver with a sample volume of 5.0 mL, and an enhancement factor of 72 was achieved. The proposed method was successfully applied to determine of trace silver in some environmental and geological samples with satisfactory results.  相似文献   

10.
A new method was developed for the determination of cadmium in water samples using ionic liquid-based ultrasound-assisted dispersive liquid–liquid microextraction (IL-based USA-DLLME) followed by electrothermal atomic absorption spectrometry (ETAAS). The IL-based USA-DLLME procedure is free of volatile organic solvents, and there is no need for a dispersive solvent, in contrast to conventional DLLME. The ionic liquid, 1-hexyl-3-methylimidazolium hexafluorophosphate (HMIMPF6), was quickly disrupted by an ultrasonic probe for 1 min and dispersed in water samples like a cloud. At this stage, a hydrophobic cadmium–DDTC complex was formed and extracted into the fine droplets of HMIMPF6. After centrifugation, the concentration of the enriched cadmium in the sedimented phase was determined by ETAAS. Some effective parameters of the complex formation and microextraction, such as the concentration of the chelating agent, the pH, the volume of the extraction solvent, the extraction time, and the salt effect, have been optimized. Under optimal conditions, a high extraction efficiency and selectivity were reached for the extraction of 1.0 ng of cadmium in 10.0 mL of water solution employing 73 µL of HMIMPF6 as the extraction solvent. The enrichment factor of the method is 67. The detection limit was 7.4 ng L− 1, and the characteristic mass (m0, 0.0044 absorbance) of the proposed method was 0.02 pg for cadmium (Cd). The relative standard deviation (RSD) for 11 replicates of 50 ng L− 1 Cd was 3.3%. The method was applied to the analysis of tap, well, river, and lake water samples and the Environmental Water Reference Material GSBZ 50009-88 (200921). The recoveries of spiked samples were in the range of 87.2–106%.  相似文献   

11.
A highly sensitive and selective fluorescence quenching method has been developed for the determination of trace tungsten in environmental samples using dibromohydroxyphenylfluorone (DBHPF) as an emission reagent. In the presence of 0.04?mol/L of sulphuric acid and acetyltrimethylammonium bromide, tungsten(VI) reacts with DBHPF to form a 1?:?3 red complex within 5.0?min. In order for the DBHPF–tungsten(VI) complex to form, the fluorescence intensity of the reagent solution was quenched linearly by adding 0.1 to 1.0?µg of tungsten(VI) in 25?mL of solution. This was measured at 528?nm with excitation at 495?nm. In this work, a standard addition method was investigated and used for sample analysis. The decrease in fluorescence intensity of the reagent solution (ΔF) was linear for 0?~?0.9?µg of tungsten(VI) in 25?mL of solution, and the detection limit (3?s) of the standard addition method was found to be 0.012?ng/mL of tungsten(VI). The effects of various metal and nonmetal ions were studied in detail. The experiments clearly showed that most foreign ions can be tolerated in considerable amounts; in particular, 50-fold Mo(VI), V(V), Zr(VI) and Ti(IV) do not interfere, and the selectivity of the proposed method is better than other previously described methods. Moreover, the method proposed here is very stable and simple, the fluorescence intensity of the solution can remain almost unchanged for 2.0?h at room temperature, and the method has been used successfully to determine tungsten in environmental samples.  相似文献   

12.
In this work, a procedure for preconcentration of cobalt using dispersive liquid–liquid microextraction (DLLME) with the reagent Br-TAO as complexing reagent was developed. The procedure is based on a ternary system of solvents, where appropriate amounts of the extraction solvent, disperser solvent and the chelating agent Br-TAO are directly injected into an aqueous solution containing Co(II). A cloudy mixture is formed and the ions are extracted in the fine droplets of the extraction solvent. After extraction, the phase separation is performed with a rapid centrifugation, and cobalt is determined in the enriched phase by FAAS. Under the optimized conditions, the detection limit obtained was 0.9 µg L− 1. The enrichment factor and the consumptive index were 16 and 0.31 mL, respectively. The accuracy of the method was tested by the determination of cobalt in certified reference material of spinach leaves, NIST 1570a. The proposed procedure was successfully applied to the determination of cobalt in water samples.  相似文献   

13.
In the present study, a rapid, highly efficient and environmentally friendly sample preparation method named temperature-controlled ionic liquid dispersive liquid-phase microextraction (TC-IL-DLPME), followed by high performance liquid chromatography (HPLC) was developed for the extraction, preconcentration and determination of four benzophenone-type ultraviolet (UV) filters (viz. benzophenone (BP), 2-hydroxy-4-methoxybenzophenone (BP-3), ethylhexyl salicylate (EHS) and homosalate (HMS)) from water samples. An ultra-hydrophobic ionic liquid (IL) 1-hexyl-3-methylimidazolium tris(pentafluoroethyl)trifluorophosphate ([HMIM][FAP]), was used as the extraction solvent in TC-IL-DLPME. Temperature served two functions here, the promotion of the dispersal of the IL to the aqueous sample solution to form infinitesimal IL drops and increase the interface between them and the target analytes (at high temperature), and the facilitation of mass transfer between the phases, and achievement of phase separation (at low temperature). Due to the ultra-hydrophobic feature and high density of the extraction solvent, complete phase separation could be effected by centrifugation. Moreover, no disperser solvent was required. Another prominent feature of the procedure was the combination of extraction and centrifugation in a single step, which not only greatly reduced the total analysis time for TC-IL-DLPME but also simplified the sample preparation procedure. Various parameters that affected the extraction efficiency (such as type and volume of extraction solvent, temperature, salt addition, extraction time and pH) were evaluated. Under optimal conditions, the proposed method provided good enrichment factors in the range of 240–350, and relative standard deviations (n = 5) below 6.3%. The limits of detection were in the range of 0.2–5.0 ng/mL, depending on the analytes. The linearities were between 1 and 500 ng/mL for BP, 5 and 1000 ng/mL for BP-3, 10 and 1000 ng/mL for HMS and 5 and 1000 ng/mL for EHS. Finally, the proposed method was successfully applied to the determination of UV filters in swimming pool and tap water samples and acceptable relative recoveries over the range of 88.0–116.0% were obtained.  相似文献   

14.
张文慧  姜廷福  吕志华  王远红 《色谱》2013,31(7):656-660
建立了基于离子液体的单滴微萃取-毛细管电泳联用测定溴酚类化合物的方法。考察了萃取剂种类与体积、萃取时间、有机溶剂、盐浓度及萃取温度对萃取效率的影响。确定了最佳萃取条件为:以1-丁基-3-甲基咪唑六氟磷酸盐([C4MIM]PF6])离子液体作为萃取剂,萃取时间为8 min,样品溶液中NaCl浓度为10%(质量分数),萃取温度为20 ℃。在最佳条件下,3种溴酚(4-溴酚、2,6-二溴酚和2,4,6-三溴酚)在1~100 mg/L范围内呈良好的线性关系,线性相关系数为0.9939~0.9988;检出限为0.3 mg/L (S/N=3);该方法对3种溴酚的富集倍数分别为115.8、327.0和569.8; 6次平行测定的相对标准偏差为5.21%~6.47%;对本地区自来水、河水和湖水的加标回收率为87.8%~96.7%。结果表明,该方法稳定可靠,适合于水体中溴酚类污染物的测定。  相似文献   

15.
Ionic liquid-based dispersive liquid-liquid microextraction was developed for the extraction and preconcentration of aromatic amine from environmental water. A suitable mixture of extraction solvent (100 μL, 1-butyl-3-methylimidazolium hexafluorophoshate) and dispersive solvent (750 μL, methanol) were injected into the aqueous samples (10.00 mL), forming a cloudy solution. After centrifuging, enriched analytes in the sediment phase were determined by HPLC-UV. The effect of various factors, such as the extraction and dispersive solvent, sample pH, extraction time and salt effect were investigated. Under optimum conditions, enrichment factors for 2-anilinoethanol, o-chloroaniline and 4-bromo-N,N-dimethylaniline were above 50 and the limits of detection (LODs) were 0.023, 0.015 and 0.026 ng/mL, respectively. Their linear ranges were 0.8-400 ng/mL for 2-anilinoethanol, 0.5-200 ng/mL for o-chloroaniline and 0.4-200 ng/mL for 4-bromo-N,N-dimethylaniline, respectively. Relative standard deviations (RSDs) were below 5.0%. The relative recoveries from samples of environmental water were in the range of 82.0-94.0%. Compared with other methods, dispersive liquid-liquid microextraction is simple, rapid, sensitive and economical.  相似文献   

16.
制备了离子液体[BMIM]PF6修饰碳糊电极(CILE), 并对其形貌和电化学行为进行了表征. 采用涂布法利用壳聚糖-皂土有机-无机复合膜将血红蛋白(Hb)固定于CILE电极表面, 利用紫外可见光谱、红外光谱和电化学方法等手段对包埋于膜内的Hb的性质进行了表征. 结果表明, Hb在薄膜内保持了其原始构象与生物活性, 循环伏安实验表明, 在pH=7.0的Britton-Robinson (B-R)缓冲液中, Hb表现出一对峰形良好的准可逆氧化还原峰, 为Hb Fe(III)/Fe(II)电对的特征峰, 对其直接电化学行为进行了研究, 求出式电位为-0.352 V(vs SCE), 电子转移数为0.885, 电荷传递系数为0.578, 表观异相电子转移速率常数为0.149 s-1.  相似文献   

17.
A new simple and rapid dispersive liquid–liquid microextraction has been applied to preconcentrate trace levels of cobalt as a prior step to its determination by spectrophotometric detection. In this method a small amount of chloroform as the extraction solvent was dissolved in pure ethanol as the disperser solvent, then the binary solution was rapidly injected by a syringe into the water sample containing cobalt ions complexed by 1-(2-pyridylazo)-2-naphthol (PAN). This forms a cloudy solution. The cloudy state was the result of chloroform fine droplets formation, which has been dispersed in bulk aqueous sample. Therefore, Co-PAN complex was extracted into the fine chloroform droplets. After centrifugation (2 min at 5000 rpm) these droplets were sedimented at the bottom of conical test tube (about 100 µL) and then the whole of complex enriched extracted phase was determined by a spectrophotometer at 577 nm. Complex formation and extraction are usually affected by some parameters, such as the types and volumes of extraction solvent and disperser solvent, salt effect, pH and the concentration of chelating agent, which have been optimised for the presented method. Under optimum conditions, the enhancement factor (as the ratio of slope of preconcentrated sample to that obtained without preconcentration) of 125 was obtained from 50 mL of water sample, and the limit of detection (LOD) of the method was 0.5 µg L?1and the relative standard deviation (RSD, n = 5) for 50 µg L?1 of cobalt was 2.5%. The method was applied to the determination of cobalt in tap and river water samples.  相似文献   

18.
In this review, the wide spectrum of the techniques of isolation and/or preconcentration and final determination of halogenated volatile organic compounds (HVOCs) in water, air, soil, sediment and biological fluids are presented and discussed. The techniques discussed are solvent microextraction, solid phase extraction, gas extraction (static and dynamic techniques), membrane processes and passive sampling. Also, direct techniques, such as direct aqueous injection into gas chromatography (GC) column and membrane inlet mass spectrometry, are presented. Main attention is paid to the practical application of these techniques during all HVOCs determination.  相似文献   

19.
A method for the analysis of clotrimazole was developed with dispersive liquid–liquid microextraction for sample pre‐concentration and HPLC–MS/MS for analysis. A linear ion trap was used for the confirmation of clotrimazole identity in the samples. The developed method enables the analysis of clotrimazole in river water and sewage effluent from wastewater treatment plants with a LOQ of 0.7 ng/L. Environmental monitoring of clotrimazole was undertaken. Samples from river water and sewage effluents were analysed over a one‐year period. Clotrimazole was found in every tested sample with concentration range from 1 to 31 ng/L. The amount of clotrimazole in tested samples was highly dependent on sampling season. The highest results were obtained in summer and autumn.  相似文献   

20.
《Analytica chimica acta》2002,460(1):111-122
Direct cold vapour generation from aqueous slurries of environmental (marine sediment, soil, coal) and biological (human hair, seafood) samples have been developed using a batch mode generation system coupled with electrothermal atomic absorption spectroscopy. The effects of several variables affecting the cold vapour generation efficiency from solid particles (hydrochloric acid and sodium tetrahydroborate concentrations, argon flow rate, acid solution volume and mean particle size) have been evaluated using a Plackett-Burman experimental design. In addition, variables affecting cold vapour trapping and atomisation efficiency on Ir-treated graphite tubes (trapping and atomisation temperatures and trapping time) have been also investigated. Atomisation and trapping temperatures, trapping time and hydrochloric acid concentration were the significant variables. The 22+star and 23+star central composite designs have been used to obtain optimum values of the variables selected. The accuracy of methods have been verified by using several certified reference materials (PACS-1, GBW-07410, NIST-1632c, CRM-397 and DORM-2). A characteristic mass of 390 pg were achieved. The detection limits of methods were in the range of 40-600 ng g−1. A particle size less than 50 μm is adequate to obtain total cold vapour generation of Hg content in the aqueous slurry particles.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号