首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
《Analytica chimica acta》2003,484(1):45-51
Alkaline-phosphatase (ALP) catalyses the hydrolysis of 1-naphthyl phosphate to fluorescent 1-naphthol (λex=346 nm, λem=463 nm). This enzymatic reaction was investigated in presence of inhibitors: organochlorine (tetradifon), carbamate (metham-sodium) and organophosphorus pesticides (fenitrothion), heavy metal (Ag+) and CN. The fluorescent signal, which is inversely dependent on the inhibitor concentration, is related to the amount of the inhibitor. Detection limits between 4.1 μM for tetradifon and 91.2 μM for metham-sodium were found. The relative standard deviation (R.S.D.) was between 2.6 and 6.2%.Sol-gel matrices derived from tetramethyl orthosilicate were doped with ALP using microencapsulation. The response of the biosensor based ALP sol-gel encapsulated to 1-naphthyl phosphate was reproducible (R.S.D.=6.6%). Inhibition plots obtained for test pesticides (metham-sodium and tetradifon) display linear calibration in the ranges 194-774 μM and 3.5-28 μM, detection limits of 4.9 and 292.3 μM and R.S.D. of 3.9 and 7.3% for metham-sodium and tetradifon, respectively. The results show that the system is able to detect class compounds such as pesticides and inorganic compounds.  相似文献   

2.
A simple and reliable technique has been developed for the construction of an amperometric acetylcholinesterase biosensor based on screen-printed carbon electrodes. For the first time, one-step modification using single-walled carbon nanotubes and Co phtalocyanine has been proposed to decrease the working potential and to increase the signal of thiocholine oxidation. The biosensor developed made it possible to detect 5-50 ppb of paraoxon and 2-50 ppb of malaoxon with detection limits of 3 and 2 ppb, respectively (incubation 15 min). The biosensor showed high reproducibility when measurements of the substrate and inhibitor were performed (R.S.D. about 1% and 2.5%, respectively). The reliability of the inhibition measurements was confirmed by testing spiked samples of sparkling and tape waters.  相似文献   

3.
In the present paper, a comparative study using Co-phthalocyanine and Prussian Blue-modified screen-printed electrodes, has been performed. Both the electrodes have demonstrated an easiness of preparation together with high sensitivity towards thicoholine (LOD = 5 × 10−7 and 5 × 10−6 M for Co-phthalocyanine and Prussian Blue, respectively) with high potentialities for pesticide measurement. Prussian Blue-modified screen-printed electrodes were then selected for successive enzyme immobilization due to their higher operative stability demonstrated in previous works. AChE and BChE enzymes were used and inhibition effect of different pesticides was studied with both the enzymes. AChE-based biosensors have demonstrated a higher sensitivity towards aldicarb (50% inhibition with 50 ppb) and carbaryl (50% inhibition with 85 ppb) while BChE biosensors have shown a higher affinity towards paraoxon (50% inhibition with 4 ppb) and chlorpyrifos-methyl oxon (50% inhibition with 1 ppb). Real samples were also tested in order to evaluate the matrix effect and recovery values comprised between 79 and 123% were obtained.  相似文献   

4.
An amperometric biosensor based on tyrosinase immobilized in silicate/Nafion composite film has been developed for the determination of phenolic compounds. The Nafion polymer in the composite was used not only to overcome the brittleness of the pure sol-gel-derived silicate film but also to increase the long-term stability of the biosensor. Tyrosinase was immobilized by a thin film of silicate/Nafion composite on a glassy carbon electrode. Phenolic compounds were determined by the direct reduction of biocatalytically-liberated quinone species at −200 mV versus Ag/AgCl (3 M NaCl). The process parameters for the fabrication of the enzyme electrode and various experimental variables such as pH and operating potential were explored for optimum analytical performance of the enzyme electrode. The biosensor can reach 95% of steady-state current in about 15 s. The sensitivities of the biosensor for catechol and phenol were 200 and 46 mA/M, respectively. A detection limit of 0.35 mM catechol was obtained with a signal-to-noise ratio of 3. The enzyme electrode retained 74% of its initial activity after 2 weeks of storage in 50 mM phosphate buffer at pH 7.  相似文献   

5.
利用溶胶 凝胶法制备壳聚糖 二氧化硅有机无机复合杂化膜,用于对辣根过氧化酶进行固定,制得测定H2O2的电流型生物传感器。以1mmol/LK4Fe(CN)6作为电子媒介体。研究了各种因素如壳聚糖与二氧化硅的比率、pH、温度、工作电位等对传感器响应电流的影响。计时电流法测定H2O2的线性范围为2.0×10-6~6.8×10-4mol/L,检出限为8.0×10-7mol/L。测得酶催化动力学参数米氏常数Km=0 87mmol/L。用该法对实际样品进行了测定。  相似文献   

6.
We report results of the studies relating to controlled deposition of the amino-functionalized silica-coated zinc oxide (Am-Si@ZnO) nano-assemblies onto an indium tin oxide (ITO) coated glass substrate using Langmuir-Blodgett (LB) technique. The monolayers have been deposited by transferring the spread solution of Am-Si@ZnO stearic acid prepared in chloroform at the air-water interface, at optimized pressure (16 mN/m), concentration (10 mg/ml) and temperature (23 °C). The high-resolution transmission electron microscopic studies of the Am-Si@ZnO nanocomposite reveal that the nanoparticles have a microscopic structure comprising of hexagonal assemblies of ZnO with typical dimensions of 30 nm. The surface morphology of the LB multilayer observed by scanning electron microscopy shows uniform surface of the Am-Si@ZnO film in the nanometer range (<80 nm). These electrodes have been utilized for chronic myelogenous leukemia (CML) detection by covalently immobilizing the amino-terminated oligonucleotide probe sequence via glutaraldehyde as a crosslinker. The response studies of these fabricated electrodes carried out using electrochemical impedance spectroscopy show that this Am-Si@ZnO LB film based nucleic acid sensor exhibits a linear response to complementary DNA (10−6–10−16 M) with a detection limit of 1 × 10−16 M. This fabricated platform is validated with clinical samples of CML positive patients and the results demonstrate its immense potential for clinical diagnosis.  相似文献   

7.
An acetylcholinesterase (AChE) purified from maize seedlings was immobilized covalently onto iron oxide nanoparticles (Fe3O4NP) and carboxylated multi walled carbon nanotubes (c-MWCNT) modified Au electrode. An organophosphorus (OP) biosensor was fabricated using this AChE/Fe3O4/c-MWCNT/Au electrode as a working electrode, Ag/AgCl as standard and Pt wire as an auxiliary electrode connected through a potentiostat. The biosensor was based on inhibition of AChE by OP compounds/insecticides. The properties of nanoparticles modified electrodes were studied by scanning electron microscopy (SEM), Fourier transform infrared (FTIR), cyclic voltammograms (CVs) and electrochemical impedance spectroscopy (EIS). The synergistic action of Fe3O4NP and c-MWCNT showed excellent electrocatalytic activity at low potential (+0.4 V). The optimum working conditions for the sensor were pH 7.5, 35 °C, 600 μM substrate concentration and 10 min for inhibition by pesticide. Under optimum conditions, the inhibition rates of OP pesticides were proportional to their concentrations in the range of 0.1–40 nM, 0.1–50 nM, 1–50 nM and 10–100 nM for malathion, chlorpyrifos, monocrotophos and endosulfan respectively. The detection limits were 0.1 nM for malathion and chlorpyrifos, 1 nM for monocrotophos and 10 nM for endosulfan. The biosensor exhibited good sensitivity (0.475 mA μM−1), reusability (more than 50 times) and stability (2 months). The sensor was suitable for trace detection of OP pesticide residues in milk and water.  相似文献   

8.
The paper describes a controllable layer-by-layer (LBL) self-assembly modification technique of multi-walled carbon nanotubes (MWNTs) and poly(diallyldimethylammonium chloride) (PDDA) towards glassy carbon electrode (GCE), Acetylcholinesterase (ACHE) was immobilized directly to the modified GCE by LBL self-assembly method, the activity value of AChE was detected by using i-t technique based on the modified Ellman method. Then the composition of carbaryl were detected by the enzyme electrode with 0.01U activity value and the detection limit of carbaryl is 10^- 12 g L ^-1 so the enzyme biosensor showed good properties for pesticides residue detection.  相似文献   

9.
Wang K  Wang L  Jiang W  Hu J 《Talanta》2011,84(2):400-405
A sensitive and selective method for the paraoxon detection based on enzyme inhibition and fluorescence quenching was presented in this study. Under the catalytic effect of acetylcholinesterase (AChE), acetylthiocholine (ATCh) hydrolysis released thiocholine (TCh) which could react with N-(7-dimethylamino-4-methylcoumarin-3-yl) maleimide (DACM) to produce a blue fluorescence compound. Subsequently, AChE catalytic activity was inhibited with the addition of paraoxon, which caused TCh decreased, leading to a significant decrease of the blue fluorescent compound. Meanwhile, p-nitrophenol, the hydrolysis product of paraoxon, would lead to a quenching of the fluorescence. Therefore, fluorescence intensity of the system would decrease dramatically by a combined effect of enzyme inhibition and fluorescence quenching. Under optimal experimental conditions, an excellent linear relationship between the decrease of fluorescence intensity and paraoxon concentration over the range from 5.5 × 10−12 to 1.8 × 10−10 mol L−1 was obtained. Fluorescence background caused by nonenzymatic hydrolysis of ATCh or other matters was relatively low, the proposed approach offered adequate sensitivity for the detection of paraoxon at 3.5 × 10−12 mol L−1.  相似文献   

10.
This paper presents an analysis method for organophosphorus insecticides based on AChE biosensors coupled with a preconcentration and oxidation on a solid phase column. Three organic solvents, acetonitrile (ACN), ethanol and methanol were tested for their influence on AChE activity, insecticide inhibition and their ability to elute the adsorbed insecticides. Our results showed that ACN in a concentration of 5% (v/v) had the less negative effect on biosensor analysis and was the most appropriate organic solvent for the column elution. The presence of the organic solvent in the incubation media of the biosensor was found to induce a reduction of the inhibition percentages. The inhibition of the biosensors was performed in phosphate buffer with 5% (v/v) ACN, while the initial and remaining response of the biosensors were measured in PBS. In these conditions, the LODs of paraoxon and dichlorvos were measured with or without a preconcentration step. The LODs of the AChE biosensor without sample preconcentration were 8 × 10−8 M for paraoxon and 1 × 10−7 M dichlorvos and the LOD obtained after the preconcentration step were 2.5 × 10−8 M for paraoxon and 2.5 × 10−8 M for dichlorvos. Moreover, the use of the column allowed the heterogeneous oxidation of organophosphorus insecticides for improved LOD.  相似文献   

11.
An amperometric pesticides inhibition biosensor has been developed and used for determination of pesticides in vegetable samples. To eliminate the interference of ascorbic acid, multilayer films of polyelectrolyte (chitosan/polystyrensulfonate) were coated on the glass carbon electrode. Then, acetylcholinesterase was immobilized on the electrode based on surface-treated nanoporous ZrO2/chitosan composite film as immobilization matrix. As a modified substrate, acetylthiocholine was hydrolysed by acetylcholinesterase and produced thiocholine which can be oxidized at +700?mV vs. SCE. Pesticides inhibit the activity of enzyme with an effect of decreasing of oxidation current. The experimental conditions were optimized. The electrode has a linear response to acetylthiocholine within 9.90?×?10?6 to 2.03?×?10?3?M. The electrode provided a linear response over a concentration range of 6.6?×?10?6 to 4.4?×?10?4?M for phoxim with a detection limit of 1.3?×?10?6?M, over a range of 1.0?×?10?8 to 5.9?×?10?7?M for malathion, and over a range of 8.6?×?10?6 to 5.2?×?10?4?M for dimethoate. This biosensor has been used to determine pesticides in a real vegetable sample.  相似文献   

12.
There is an increasing need to develop biosensors for the detection of harmful pesticide residues in food and water. Here, we report on a versatile strategy to synthesize functionalized graphene oxide nanomaterials with abundant affinity groups that can capture histidine (His)-tagged acetylcholinesterase (AChE) for the fabrication of paraoxon biosensors. Initially, exfoliated graphene oxide (GO) was functionalized by a diazonium reaction to introduce abundant carboxyl groups. Then, Nα,Nα-bis(carboxymethyl)-l-lysine hydrate (NTA-NH2) and Ni2+ were anchored onto the GO based materials step by step. AChE was immobilized on the functionalized graphene oxide (FGO) through the specific binding between Ni-NTA and His-tag. A low anodic oxidation potential was observed due to an enhanced electrocatalytic activity and a large surface area brought about by the use of FGO. Furthermore, a sensitivity of 2.23 μA mM−1 to the acetylthiocholine chloride (ATChCl) substrate was found for our composite covered electrodes. The electrodes also showed a wide linear response range from 10 μM to 1 mM (R2 = 0.996), with an estimated detection limit of 3 μM based on an S/N = 3. The stable chelation between Ni-NTA and His-tagged AChE endowed our electrodes with great short-term and long-term stability. In addition, a linear correlation was found between paraoxon concentration and the inhibition response of the electrodes to paraoxon, with a detection limit of 6.5 × 10−10 M. This versatile strategy provides a platform to fabricate graphene oxide based nanomaterials for biosensor applications.  相似文献   

13.
This study was aimed at the development of a conductometric biosensor based on acetylcholinesterase considering the feasibility of its application for the inhibitory analysis of various toxicants. In this paper, the optimum conditions for enzyme immobilization on the transducer surface are selected as well as the optimum concentration of substrate for inhibitory analysis. Sensitivity of the developed biosensor to different classes of toxic compounds (organophosphorus pesticides, heavy metal ions, surfactants, aflatoxin, glycoalkaloids) was tested. It is shown that the developed biosensor can be successfully used for the analysis of pesticides and mycotoxins, as well as for determination of total toxicity of the samples. A new method of biosensor analysis of toxic substances of different classes in complex multicomponent aqueous samples is proposed.  相似文献   

14.
Hemoglobin (Hb) was entrapped in a titania sol-gel matrix and used as a mimetic peroxidase to construct a novel amperometric biosensor for hydrogen peroxide. The Hb entrapped titania sol-gel film was obtained with a vapor deposition method, which simplified the traditional sol-gel process for protein immobilization. The morphologies of both titania sol-gel and the Hb films were characterized using scanning electron microscopy (SEM) and proved to be chemically clean, porous, homogeneous. This matrix provided a biocompatible microenvironment for retaining the native structure and activity of the entrapped Hb and a very low mass transport barrier to the substrates. H2O2 could be reduced by the catalysis of the entrapped hemoglobin at −300 mV without any mediator. The reagentless H2O2 sensor exhibited a fast response (less than 5 s) and sensitivity as high as 1.29 mA mM−1 cm−2. The linear range for H2O2 determination was from 5.0×10−7 to 5.4×10−5 M with a detection limit of 1.2×10−7 M. The apparent Michaelis-Menten constant of the encapsulated hemoglobin was calculated to be 0.18±0.02 mM. The stability of the biosensor was also evaluated.  相似文献   

15.
A new high-sensitivity surface plasmon resonance (SPR) biosensor based on biofunctional gold nanostars (AuNSs) and carboxyl-functionalized graphene oxide (cGO) sheets was described. Compared with spherical gold nanoparticles (AuNPs), the anisotropic structure of AuNSs, which concentrates the electric charge density on its sharp tips, could enhance the local electromagnetic field and the electronic coupling effect significantly. cGO was obtained by a diazonium reaction of graphene oxide (GO) with 4-aminobenzoic acid. Compared with GO, cGO could immobilize more antibodies due to the abundant carboxylic groups on its surface. Testing results show that there are fairly large improvements in the analytical performance of the SPR biosensor using cGO/AuNSs-antigen conjugate, and the detection limit of the proposed biosensor is 0.0375 μg mL−1, which is 32 times lower than that of graphene oxide-based biosensor.  相似文献   

16.
Organophosphate pesticides (OPs) have been intensively used as insecticides in agriculture; after entering the aquatic environment, they may affect a wide range of organisms. A conductometric enzymatic biosensor based on lipase extracted from Candida rugosa (CRL) has therefore been developed for the direct and rapid quantitative detection of organophosphate pesticides: diazinon, methyl parathion and methyl paraoxon in water. The biosensor signal and response time were obtained under optimum conditions, the enzyme being immobilised in the presence of gold nanoparticles. Under these conditions, the enzymatic biosensor was able to measure concentrations as low as 60 µg/L of diazinon, 26 µg/L of methyl parathion and 25 µg/L of methyl paraoxon very rapidly (response time: 3 min). Moreover, this CRL biosensor was not sensitive to interferences such as carbamates. It presented good storage stability for 21 days when kept at 4°C and it was successfully applied to real samples.  相似文献   

17.
Zinc oxide nanoparticles (NanoZnO) uniformly dispersed in chitosan (CHIT) have been used to fabricate a hybrid nanocomposite film onto indium-tin-oxide (ITO) glass plate. Cholesterol oxidase (ChOx) has been immobilized onto this NanoZnO-CHIT composite film using physiosorption technique. Both NanoZnO-CHIT/ITO electrode and ChOx/NanoZnO-CHIT/ITO bioelectrode have been characterized using Fourier transform-infrared (FTIR), X-ray diffraction (XRD), cyclic voltammetry (CV), scanning electron microscopy (SEM) and electrochemical impedance spectroscopy (EIS) techniques, respectively. The ChOx/NanoZnO-CHIT/ITO bioelectrode exhibits linearity from 5 to 300 mg dl−1 of cholesterol with detection limit as 5 mg dl−1, sensitivity as 1.41 × 10−4 A mg dl−1 and the value of Michaelis-Menten constant (Km) as 8.63 mg dl−1. This cholesterol biosensor can be used to estimate cholesterol in serum samples.  相似文献   

18.
李峰  王振  冯艳 《中国科学B辑》2009,39(7):640-645
利用一步电沉积法,以含有环氧基团的γ-环氧丙氧丙基三甲氧基硅烷(GPTMS)为无机杂化试剂和功能性交联试剂,通过壳聚糖(Chitosan,CS)、辣根过氧化物酶(HRP)和葡萄糖氧化酶(GOD)分子中-NH2与环氧基团的反应,在金电极表面原位制备交联型有机-无机生物杂化膜,得到共固定HRP和GOD的新型双酶生物传感器.实验证实了这种有机-无机生物杂化膜在不同酸、碱条件下都具有高的稳定性和耐用性,克服了CS酸溶的不足,从而扩大了其使用范围.在葡萄糖检测中,交联型双酶传感器HRP-GOD/GPTMS/CS,Au比无交联的双酶传感器HRP-GOD/CS/Au具有更高的灵敏度、更宽的线性范围,其线性范围为1μmol/L-351μmol/L,检期4限为0.3μmol/L.  相似文献   

19.
Herein, the fabrication and electrochemical characterization of a novel clorsulon (CLO) sensor were evaluated. Among the different tested metal oxides nanostructures, bulk modification of the carbon paste working electrode with zinc oxide exhibited the proper electrocatalytic activity towards CLO with irreversible anodic oxidation peak at 1.02 in universal buffer pH 7.0. Clorsulon molecule showed diffusion–reaction mechanism through the involvement of one-electron and one proton as illustrated by the sweep rate, pH studies, and sustained by the molecular orbital calculations. The fabricated sensors showed linear calibration curves within the CLO concentration range from 0.45 to 10.13 × 10?9 mol L?1 with LOD value of 0.14 × 10?9 mol L?1. Enhanced sensitivity with good measurement reproducibility and long operational lifetime were cited as shining futures of the fabricated sensor. The constructed sensors were utilized for clorsulon quantification in veterinary formulations and milk samples with high accuracy and precision compared with the traditional methods.  相似文献   

20.
In this paper, we report a versatile synthetic method of ordered rare-earth metal (RE) oxide nanotubes. RE (RE=Y, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Yb) oxide nanotubes were successfully prepared from corresponding RE nitrate solution via the sol-gel method assisted with porous anodic aluminum oxide (AAO) templates. Scanning electron microscopy (SEM), transmission electron microscopy (TEM), high-resolution TEM, and X-ray diffraction (XRD) have been employed to characterize the morphology and composition of the as-prepared nanotubes. It is found that as-prepared RE oxides evolve into bamboo-like nanotubes and entirely hollow nanotubes. A new possible formation mechanism of RE oxide nanotubes in the AAO channels is proposed. These high-quantity RE oxide nanotubes are expected to have promising applications in many areas such as luminescent materials, catalysts, magnets, etc.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号