首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The reliability of analytical data is very important to forensic and clinical toxicologists for the correct interpretation of toxicological findings. This makes (bio)analytical method validation an integral part of quality management and accreditation in analytical toxicology. Therefore, consensus should be reached in this field on the kind and extent of validation experiments as well as on acceptance criteria for validation parameters. In this review, the most important papers published on this topic since 1991 have been reviewed. Terminology, theoretical and practical aspects as well as implications for forensic and clinical toxicology of the following validation parameters are discussed: selectivity (specificity), calibration model (linearity), accuracy, precision, limits, stability, recovery and ruggedness (robustness). Received: 16 June 2002 Accepted: 12 July 2002 Part of this review was published in the communications of the International Association of Forensic Toxicologists (TIAFT; TIAFT Bulletin 32 (2002): 16–23) and of the Society for Forensic and Toxicologic Chemistry (GTFCH; Toxichem and Krimitech 68 (2001): 116-126). Correspondence to F. T. Peters  相似文献   

2.
Green chemistry principles for developing methodologies have gained attention in analytical chemistry in recent decades. A growing number of analytical techniques have been proposed for determination of organic persistent pollutants in environmental and biological samples. In this light, the current review aims to present state-of-the-art sample preparation approaches based on green analytical principles proposed for the determination of polybrominated diphenyl ethers (PBDEs) and metabolites (OH-PBDEs and MeO-PBDEs) in environmental and biological samples. Approaches to lower the solvent consumption and accelerate the extraction, such as pressurized liquid extraction, microwave-assisted extraction, and ultrasound-assisted extraction, are discussed in this review. Special attention is paid to miniaturized sample preparation methodologies and strategies proposed to reduce organic solvent consumption. Additionally, extraction techniques based on alternative solvents (surfactants, supercritical fluids, or ionic liquids) are also commented in this work, even though these are scarcely used for determination of PBDEs. In addition to liquid-based extraction techniques, solid-based analytical techniques are also addressed. The development of greener, faster and simpler sample preparation approaches has increased in recent years (2003–2013). Among green extraction techniques, those based on the liquid phase predominate over those based on the solid phase (71% vs. 29%, respectively). For solid samples, solvent assisted extraction techniques are preferred for leaching of PBDEs, and liquid phase microextraction techniques are mostly used for liquid samples. Likewise, green characteristics of the instrumental analysis used after the extraction and clean-up steps are briefly discussed.  相似文献   

3.
《Analytica chimica acta》2004,512(2):287-295
The potential of non-aqueous capillary electrophoresis (NACE) was investigated for the simultaneous separation of paroxetine, tamoxifen, and their main metabolites. Baseline separation of the studied solutes was obtained on a  μm capillary using a non-aqueous buffer composed of 18 mM ammonium acetate and 1.1% acetic acid in 80:20 (v/v) methanol-acetonitrile, with a temperature and voltage of 22 °C and 15 kV, respectively. Clomipramine was used as internal standard. Aspects such as stability of the solutions, linearity, accuracy, precision and ruggedness were examined in order to validate the proposed method. Detection limits obtained for all the studied compounds ranged between 3.0 and 7.1 μg l−1. The developed method is sensitive and robust and was used to determine paroxetine, tamoxifen, and their metabolites at clinically relevant levels in human urine. Before NACE determination, the samples were purified and enriched by means of an extraction-pre-concentration step with a pre-conditioned C18 cartridge. Determination of these analytes in the urine of four females urines was demonstrated.  相似文献   

4.
Metabolomics is an emerging field dealing with the measurement and interpretation of small molecular byproducts of biochemical processes, or metabolites, which can be used to generate profiles from biological samples. Promising for use in pathophysiology, metabolomic profiles give the immediate biological state of a sample. These profiles are altered in diseases and are detectable in biological samples, such as tissue, blood, urine, saliva, and others. Most remarkably, metabolic profiles usually are altered before symptoms appear in a patient. For this reason, metabolomics has potential as a reliable method for an early diagnosis of diseases through disease biomarker identification. This application is most prevalent in cancer, such as head and neck cancer (HNC). Metabolomic studies offer avenues to improve on current medical techniques through the application of mass spectrometry (MS), nuclear magnetic resonance spectroscopy (NMR), and statistical analysis to determine better biomarkers than those currently known. In this review, we discuss the use of MS and NMR tools for detecting biomarkers in tissue and fluid samples, and the appropriateness of metabolomics in analyzing cancer. Advantages, disadvantages, and recent studies on metabolomic profiling techniques in HNC analysis are also discussed herein.  相似文献   

5.
Bioanalytical methods for the determination of antipsychotic drugs   总被引:1,自引:0,他引:1  
Antipsychotic drugs are popular for the treatment of schizophrenia and other psychoses. In general, antipsychotics are administered in oral doses of only a few milligrams per day and they are widely metabolized in the body. Therefore, the concentration of these drugs in plasma is very low (pg-ng/mL levels). In addition, therapeutic drug monitoring (TDM) of antipsychotic drugs has proven to be of notable value for determining poor compliance of patients and addressing the challenges associated with considerable genetic variability in their metabolism. Thus, in order to conduct pharmacology and toxicology studies and clinical TDM of antipsychotics, as well as address the challenges associated with polypharmacy and drug metabolism, highly sensitive, selective and accurate bioanalytical methods are essential. The most recent studies on the determination of antipsychotics will be reviewed, including separation techniques, sample pretreatment, detectors and validation.  相似文献   

6.
7.
The measurement of catecholamines and their metabolites in biological samples remains a current analytical challenge, in spite of the great diversity of methodologies that have been developed throughout the years. High-performance liquid chromatography is the standard method for their separation and quantification in biological samples, either coupled with electrochemical, fluorescence, chemiluminescence or mass spectrometry detection. This review summarizes the most important physicochemical properties of catecholamines, the wide panoply of sample preparation techniques and the main issues to consider during the development of chromatographic methods. The major difficulties encountered during the optimization of these procedures are related with the high tendency of catecholamines to oxidize and the very low quantities at which they exist in biological matrices. Herein, the most important aspects that ought to be considered during collection, treatment and storage of fluid and tissue samples intended for catecholamine analysis are underlined, the chromatographic conditions are compared and the technical advantages and limitations of each detection system are discussed.  相似文献   

8.
Recent advances in analytical techniques have enabled the detection of drugs and drug metabolites in oral fluid specimens. Although GC–MS is still commonly used in practice, many laboratories have developed and successfully validated methods for LC–MS(–MS) that can detect a large number of compounds in the limited sample volume available. In addition, several enzyme immunoassays have been commercialized for the detection of drugs of abuse in oral fluid samples, enabling the fast screening and selection of presumably positive samples. A number of concerns are discussed, such as the variability in the volume of sample collected and its implications in terms of quantitative measurements, and the drug recoveries of the many different specimen collection systems on the market. Additional considerations that also receive attention are the importance of providing complete validation data with respect to analyte stability, matrix effect, and the choice of collection method.  相似文献   

9.
3,4-Methylenedioxymethamphetamine (MDMA) is a racemic drug of abuse and its R- and S-enantiomers are known to differ in their dose-response curve. The S-enantiomer was shown to be eliminated at a higher rate than the R-enantiomer most likely explained by stereoselective metabolism that was observed in various in vitro experiments. The aim of this work was the development and validation of methods for evaluating the stereoselective elimination of phase I and particularly phase II metabolites of MDMA in human urine. Urine samples were divided into three different methods. Method A allowed stereoselective determination of the 4-hydroxy-3-methoxymethamphetamine (HMMA) glucuronides and only achiral determination of the intact sulfate conjugates of HMMA and 3,4-dihydroxymethamphetamine (DHMA) after C18 solid-phase extraction by liquid chromatography-high-resolution mass spectrometry with electrospray ionization. Method B allowed the determination of the enantiomer ratios of DHMA and HMMA sulfate conjugates after selective enzymatic cleavage and chiral analysis of the corresponding deconjugated metabolites after chiral derivatization with S-heptafluorobutyrylprolyl chloride using gas chromatography-mass spectrometry with negative-ion chemical ionization. Method C allowed the chiral determination of MDMA and its unconjugated metabolites using method B without sulfate cleavage. The validation process including specificity, recovery, matrix effects, process efficiency, accuracy and precision, stabilities and limits of quantification and detection showed that all methods were selective, sensitive, accurate and precise for all tested analytes.  相似文献   

10.
Selenium speciation from food source to metabolites: a critical review   总被引:4,自引:0,他引:4  
Especially in the last decade, a vast number of papers on Se and its role in health issues have been published. This review gives a brief, critical overview of the main analytical findings reported in these papers. Of particular interest is the Se content in different food sources worldwide and the extent to which their consumption is reflected in the Se content of human tissues and body fluids. Several food sources, both natural (Brazil nuts, garlic, Brassica juncea) and Se-enriched (yeast-based supplements), are discussed as to origin, characteristics, Se metabolism and impact of their consumption on the human body. The continuous development of new and improvement of existing analytical techniques has provided different powerful tools to unravel the Se species and their function. An up-to-date literature study on Se speciation analysis is given, illustrating how analytical chemistry in its different facets aids in the identification of Se compounds and provides insight into the complete metabolic pathway of Se throughout the human body. This review includes a detailed image of the current state-of-the-art of Se speciation analysis in these food sources and in human tissues and body fluids.  相似文献   

11.
Zeng D  Shen X  He L  Ding H  Tang Y  Sun Y  Fang B  Zeng Z 《Journal of separation science》2012,35(10-11):1327-1335
A rapid liquid chromatography tandem mass spectrometric method was developed for the simultaneous determination of mequindox and its five metabolites (2-isoethanol mequindox, 2-isoethanol 1-desoxymequindox, 1-desoxymequindox, 1,4-bisdesoxymequindox, and 2-isoethanol bisdesoxymequindox) in porcine muscle, liver, and kidney, fulfilling confirmation criteria with two transitions for each compound with acceptable relative ion intensities. The method involved acid hydrolysis, purification by solid-phase extraction, and subsequent analysis with liquid chromatography tandem mass spectrometry using electrospray ionization operated in positive polarity with a total run time of 15 min. The decision limit values of five analytes in porcine tissues ranged from 0.6 to 2.9 μg/kg, and the detection capability values ranged from 1.2 to 5.7 μg/kg. The results of the inter-day study, which was performed by fortifying porcine muscle (2, 4, and 8 μg/kg), liver, and kidney (10, 20, and 40 μg/kg) samples on three separate days, showed that the accuracy of the method for the various analytes ranged between 75.3 and 107.2% with relative standard deviation less than 12% for each analyte.  相似文献   

12.
The detection and quantification of biomarkers have gained more attention in the medical discipline to evaluating disease progression to manage medical treatment. Biomarkers range from gases to biological macromolecules. Because of the nanomolar range levels of typical biomarkers in plasma, blood, urine, exhalation samples, and other biological fluids as well as complex matrix of biological media, adequate sample preparation methods should be used for quantification of biomarkers. Biomarkers are discussed here generally classified mainly into two subgroups which arisen from disease or exposure compounds. The analytical method is critical for the validity/reliability of a biomarker. Accuracy, precision, reproducibility, recovery, sensitivity, and specificity all have high influence to the consistency with the limit and reference values concerned. In this paper, developments in well-established liquid-phase microextraction techniques for the clinical analysis of biological samples will be reviewed and discussed. This article presents an overview of microextraction methods for biological samples, focusing especially on biomarkers.  相似文献   

13.
We have developed a method for the determination of tamoxifen (tam) and its metabolites 4-hydroxytamoxifen (4OHtam), N-demethyltamoxifen (NDtam), N-dedimethyltamoxifen (NDDtam), tamoxifen-N-oxide (tamNox), and 4-hydroxy-N-demethyltamoxifen (4OHNDtam) in 50 microl human serum. Serum proteins were precipitated with acetonitrile. Deuterated-tamoxifen (D5 tam) was added as internal standard. Sample supernatant was injected into an on-line reversed-phase extraction column coupled with a C18 analytical column and analytes were detected by tandem mass spectrometry. The lower limits of quantification were 0.25 ng/mL for 4OHtam, NDtam and tam, 1.0 ng/mL for NDDtam and tamNox. Ranges of within- and between-day variation were 2.9-15.4% and 4.4-12.9%, respectively.  相似文献   

14.
In the past years, it has been recognised that the levodopa therapy may be improved with therapeutic regimens including a catechol-O-methyltransferase (COMT) inhibitor. At the present time, tolcapone and entacapone are the only two COMT inhibitors available in the market. However, further COMT inhibitors are under development for Parkinson's disease, namely nebicapone and opicapone (formerly known as BIA 9-1067). In addition, the nitecapone, another well-known COMT inhibitor, is also in preclinical development but for neuropathic pain. Since the 1990s different liquid chromatography methods have been developed and validated to quantify tolcapone, entacapone, nitecapone, nebicapone and some metabolites in biological samples, particularly in plasma samples obtained from rodent and human species. These bioanalytical methods have been primarily used to support pharmacokinetic assays with such COMT inhibitors in non-clinical and clinical studies. As these inhibitors present hydrophobic groups in their chemical structures, reversed-phase liquid chromatography has been used as the major approach for the determination of such compounds, especially high-performance liquid chromatography coupled to ultraviolet detection (HPLC-UV), electrochemical detection (HPLC-ECD) and mass spectrometry detection (HPLC–MS). Regarding the sample preparation, the traditional liquid–liquid extraction (LLE) and solid-phase extraction (SPE) were also the most widely used procedures for extraction of the analytes of interest prior to the analysis of samples. Thus, this review aimed to gather, for the first time, sufficient background information about the bioanalytical chromatographic methods which have been already developed and applied for the determination of tolcapone, entacapone, nitecapone, nebicapone and their metabolites. Moreover, some pharmacokinetic aspects of the COMT inhibitors with interest from a bioanalytical perspective were also addressed.  相似文献   

15.
A procedure based on solid phase extraction (SPE) has been developed for the simultaneous pre-concentration of herbicide mefenacet (MN) and its three photolysis degradation products. Three metabolites studied were hydroxylbenzothiazole (HBT), N-methylaniline (N-MA) and 2-benzothiazoloxyacetic acid (2-BAA). A trimethylsilylation derivatization method was applied for the analysis of HBT and 2-BAA which were derivatized to be corresponding derivatives D-1 and D-2, respectively, and a rapid resolution liquid chromatography-electrospray ionization mass spectrometry (RRLC-ESI-MS) system was used for the separation, identification and quantification of these four analytes. In the SPE pre-concentration step, three types of cartridges and four kinds of eluents were investigated. The mean recoveries of these four analytes were between 78.6% and 101.2% and relative standard deviations were between 3.2% and 9.2%. The limits of detection (LODs) obtained were 0.02 ng l−1 for MN and N-MA and 0.1 ng l−1 for HBT and 2-BAA which were less than the maximum residue limits (MRLs) in drinking water established by European legislation (0.1 μg l−1). The proposed method was applied to evaluate the presence and evolution with time of herbicide mefenacet and its degradation products in samples of Songhuajiang River of Heilongjiang province, China. The analyses, conducted from April to July of 2008, pointed to the presence of MN, 2-BAA, HBT and N-MA at maximum levels 1.0, 0.08, 0.1 and 0.3 μg l−1.  相似文献   

16.
Liquid-phase microextraction based on polypropylene hollow fibers and CE were applied for the chiral determination of hydroxychloroquine (HCQ) and its metabolites (desethylchloroquine, DCQ; desethylhydroxychloroquine, DHCQ; bisdesethylchloroquine, BDCQ) in human urine. The analytes were extracted from 3 mL of urine spiked with the internal standard (metoprolol) and alkalinized with 250 muL of 2 M NaOH. The analytes were extracted into 1-octanol impregnated in the pores of the hollow fiber, and into an acid acceptor solution inside the hollow fiber. The electrophoretic separations were carried out in 100 mmol/L Tris buffer (pH adjusted to 9.0 with phosphoric acid) containing 1% w/v S-beta-CD and 30 mg/mL HP-beta-CD with a constant voltage of +18 kV. The method was linear over the concentration range of 10-1000 ng/mL for each HCQ stereoisomer and 21-333 ng/mL for each metabolite stereoisomer. Within-day and between-day assay precision and accuracy for the analytes were studied at three concentration levels for each stereoisomer and were lower than 15%. The developed method was applied for the determination of the cumulative urinary excretion of HCQ, DCQ, and DHCQ after oral administration of rac-HCQ to a health volunteer. The results obtained are in agreement with previous literature data.  相似文献   

17.
Recent research has looked to develop innovative and powerful novel biofunctionalized nanometer-sized silica particles, controlling and tailoring their properties in a very predictable manner to meet the needs of specific applications. The silica shells of these particles facilitate a wide variety of surface reactions and allow conjugation with biomolecules like proteins and DNA. There exist a multitude of possible applications of fabricated nanoparticles in biotechnology and medicine. In particular, they have proved to be highly useful for biosensing, assay labelling, bioimaging, and in research on a variety of molecular tags in cellular and molecular biology. Techniques commonly rely on the use of silica-coated semiconductor quantum dots, organic dyes, magnetic particles, and Raman active particles. Inorganic-biological hybrid particles combine the properties of both materials, i.e., the spectroscopic characteristics of the entrapped nanocrystal, and the biomolecular function of the conjugated entity. Rather than being exhaustive, this review focuses on selected examples to illustrate novel concepts and promising applications. Approaches described include the encoding of silica nanoparticles with different groups, and conjugation with various biological entities. Further, promising applications in bioanalysis are considered and discussed.  相似文献   

18.
The enantioselective analysis of hydroxychloroquine (HCQ) and its major metabolites was achieved by HPLC and solid-phase microextraction. The chromatographic separation was performed on a Chiralcel OD-H column using hexane/methanol/ethanol (96:2:2, v/v/v) plus 0.2% diethylamine as the mobile phase, at the flow rate of 1.3 mL/min. The main extraction parameters were optimized. The best condition was achieved by the addition of 10% NaCl and 1 mL phosphate buffer 1 mol/L pH 11 to 3 mL human urine. The extraction was conducted for 40 min at 25 degrees C and the desorption time was 3 min using methanol (100%). PDMS-DVB 60 microm fiber was used in this study. The mean recoveries were 9.3, 9.2, and 14.4% for HCQ, desethylhydroxychloroquine (DHCQ), and desethylchloroquine (DCQ), respectively. The method was linear over the range of 50-1000 ng/mL for HCQ enantiomers and over the range of 42-416 ng/mL for DCQ and DHCQ enantiomers. Within-day and between-day precision and accuracy assays for HCQ and its metabolites were lower than 15%. The preliminary 48 h urinary excretion study performed in human urine showed to be stereoselective. The amount of (+)-(S)-enantiomer excreted was higher than its antipode.  相似文献   

19.
The bioanalysis of the oral anticancer drug capecitabine and its metabolites has been investigated extensively over the past years. This paper reviews methods for the bioanalysis of capecitabine and its metabolites. The focus of this review will be on sample pre-treatment, chromatography and detection. Furthermore, the choice of standards and analytical problems encountered during analysis of capecitabine and its metabolites in biological matrices will be discussed. The major challenges in the bioanalysis of capecitabine and its metabolites are the simultaneous extraction and analysis due to the differences in polarity of the analytes. Furthermore we evaluate currently described methods for the quantification of capecitabine and its metabolites. Future wishes and perspectives are stated that could serve as an inspiration for further development of assays for the quantification of capecitabine and its metabolites.  相似文献   

20.
Sastry CS  Rao JS  Rao KR 《Talanta》1995,42(10):1479-1485
Three simple and sensitive spectrophotometric methods for the determination of tamoxifen citrate have been developed. They are based on the formation of an ion-association complex between the drug and a dye, Erioglaucine A, which is extractable into chloroform and has an absorption maximum at 625 nm (method A), oxidation with excess potassium permanganate and the determination of unconsumed permanganate using Fast Green FCF (method B), or by the formation of a coloured cobalt thiocyante coordination complex which is extracted into benzene and measured at 635 nm (method C). Beer's law limits for methods A, B, and C are 0.5-3.0 mug ml(-1), 1.0-6.0 mug ml(-1) and 100-500 mug ml(-1), respectively. No interference was observed from tableting additives and the applicability of the methods was examined by analysing tablets containing tamoxifen. The quantities determined were 99.0-100.03% of the exptected values.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号