1.
The present technique describes the development of a simple sensitive spot optical test and the construction of a portable biosensor for the rapid one-shot detection of naphthalene acetic acid (NAA) using stabilized lipid films supported on a methacrylate polymer on a glass fiber filter with incorporated auxin-binding protein 1 receptor. The lipid films without the receptor provided fluorescence under a UV lamp. The use of the receptor in these films quenched this fluorescence and the colour became similar to that of the filters without the lipid films. A drop of aqueous solution of naphthalene acetic acid provided a “switching on” of the fluorescence which allows the rapid detection of this stimulant at the levels of 10−9 M concentrations. It was also possible to have quantitative data based on a calibration graph. The effect of potent interferences included a wide range of compounds. The results showed no interferences from these compounds in concentration levels usually found in real samples. The method was applied for the determination of NAA in fruits and vegetables and the reproducibility of the method was checked in about 50 samples. A quantitative method for the detection of NAA in crops that can be complimentary to HPLC methods is provided in the present paper. These lipid films can be used as portable biosensors for the rapid one-shot detection of NAA in fruits and vegetables by non-skilled personnel in the field.  相似文献   

2.
The present technique describes the preparation of a selective receptor for carbofuran and the development of a simple sensitive spot optical test for the rapid one-shot detection of carbofuran using stabilized lipid films supported on a methacrylate polymer on a glass fiber filter with incorporated artificial receptor. The selective receptor was synthesized by a chemical reaction using a resorcin[4]arene receptor by transforming all the –OH groups into phosphoryl groups. The lipid films without this receptor provided fluorescence under a UV lamp. The use of the receptor in these films quenched this fluorescence and the colour became similar to that of the filters without the lipid films. A drop of aqueous solution of carbofuran provided a “switching on” of the fluorescence which allows the rapid detection of this insecticide at the levels of 10−9 M concentrations. The effect of potent interferences included a wide range of compounds. The results showed no interferences from these compounds in concentration levels usually found in real samples. The effect of interference of proteins and lipids was also examined. The reproducibility of the method was checked in about 100 samples and all of them were found to provide similar results. The device was tested/evaluated in real samples of fruits, vegetables and dairy products. Note that the colours of the filters remain stable for periods of more than 2 months.  相似文献   

3.
An optical biosensor for urea based on urease enzyme immobilised on functionalised calcium carbonate nanoparticles (CaCO3-NPs) was successfully developed in this study. CaCO3-NPs were synthesised from discarded cockle shells via a simple and eco-friendly approach, followed by surface functionalisation with succinimide ester groups. The fabricated biosensor is comprised of two layers. The first (bottom layer) contained functionalised NPs covalently immobilised to urease, and the second (uppermost layer) was alginate hydrogel physically immobilised to the pH indicator phenolphthalein. The biosensor provided a colorimetric indication of increasing urea concentrations by changing from colourless to pink. Quantitative urea analysis was performed by measuring the reflectance intensity of the colour change at a wavelength of 633.16 nm. The determination of urea concentration using this biosensor yielded a linear response range of 30–1000 mM (R2 = 0.9901) with a detection limit of 17.74 mM at pH 7.5. The relative standard deviation of reproducibility was 1.14%, with no signs of interference by major cations, such as K+, Na+, NH?+, and Mg2+. The fabricated biosensor showed no significant difference with the standard method for the determination of urea in urine samples.  相似文献   

4.
Herein, we reported for the first time that gold nanoparticles-catalyzed 3,3′,5,5′-tetramethylbenzidine-H2O2 system can serve as an ultrasensitive colorimetric pH indicator. Gold nanoparticles acted as a catalyst and imitated the function of horseradish peroxidase. The absorbance at 450 nm of the yellow-color product in the catalytic reaction exhibited a linear fashion over the pH range of 6.40–6.60. On the basis of this property, we constructed a novel sensing platform for the determination of urea, urease, and urease inhibitor. The limit of detection for urea and urease was 5 μM and 1.8 U/L, respectively. The half-maximal inhibition value IC50 of acetohydroxamic acid was found to be 0.05 mM. Urea in human urine and urease in soil were detected with satisfied results.  相似文献   

5.
Improving the reproducibility of electrochemical signal remains a great challenge over the past decades. In this work, i-motif oligonucleotide probe-based electrochemical DNA (E-DNA) sensor is introduced for the first time as a regenerated sensing platform, which enhances the reproducibility of electrochemical signal, for label-free detection of glucose and urea. The addition of glucose or urea is able to activate glucose oxidase-catalyzed or urease-catalyzed reaction, inducing or destroying the formation of i-motif oligonucleotide probe. The conformational switch of oligonucleotide probe can be recorded by electrochemical impedance spectroscopy. Thus, the difference of electron transfer resistance is utilized for the quantitative determination of glucose and urea. We further demonstrate that the E-DNA sensor exhibits high selectivity, excellent stability, and remarkable regenerated ability. The human serum analysis indicates that this simple and regenerated strategy holds promising potential in future biosensing applications.  相似文献   

6.
A new optical sensor for urea determination is presented. It is based on the enzymatic reaction with urease, which is first photoimmobilized with polyacrylamide onto a chemically polymerized polypyrrole (PPy) film. The main advantage of this sensor is that no indicator dye or pH indicator is needed, because PPy itself acts as the support and the indicator. These PPy films show an absorbance spectrum in the near IR range which is pH dependent. The variation of absorbance is thus directly related to the change of pH caused during the enzymatic reaction, which is also dependent on the urea concentration. The linear range of the sensor is from 0.06 to 1 M of urea, which is the common level of urea concentration found in blood and urine samples.  相似文献   

7.
高灵敏的生物传感器在痕量真菌毒素污染的快速检测中备受关注.适配体除具有与抗体类似的高选择性外,还具有可体外合成和易修饰等独特优势,已成为现阶段生物传感器中常用的识别元件.随着指数富集的配体系统进化(SELEX)技术的发展,筛选获得的真菌毒素适配体越来越多,为不同真菌毒素的检测提供了基础条件,而适配体结合现代新型纳米材料...  相似文献   

8.
9.
A novel application of an electrochemical biosensor is here employed as analytical method for the detection and presumptive identification of antimicrobial drug residues in milk. The measurement was based on carbon dioxide production rate in relation to inhibition of microbial grow (Escherichia coli ATCC 11303). In this pilot study quinolone and tetracycline residues have been taken into consideration because use of these last in livestock production has been identified as area of particular concern. The experimental approach and analytical method developed appear adequate for the purpose, and compared to older screening methods as, for example, the microbial inhibition assays and immunoassays, offers the advantages of (i) very short analysis time (about 120 min); (ii) smaller sample amount (approximately 0.5 mL); (iii) no sample treatment (iv) good precision; and (v) the possibility of following, in a continuous manner, the inhibition process. Moreover, sensitivity of electrochemical biosensor system is resulted very high considering that for all quinolones and tetracyclines investigated it has been possible detect a residue concentration below or equal to 25 μg L−1. Under this point of view, it must be considered that the maximum residue limits fixed by UE for quinolones and tetracyclines in milk are, at present, all higher of this concentration.  相似文献   

10.
A novel optical chemosensor was fabricated based on 1-amino-8-naphthol-3,6-disulfonic acid sodium (H-acid) intercalated layered double hydroxide (LDH) film via the electrophoretic deposition (EPD) method. The film of H-acid/LDH with the thickness of 1 μm possesses a well c-orientation of the LDH microcrystals confirmed by X-ray diffraction (XRD) and scanning electron microscopy (SEM). The fluorescence detection for Hg(II) in aqueous solution was performed by using the H-acid/LDH film sensor at pH 7.0, with a linear response range in 1.0 × 10−7 to 1.0 × 10−5 mol L−1 and a detection limit of 6.3 × 10−8 mol L−1. Furthermore, it exhibits excellent selectivity for Hg(II) over a large number of competitive cations including alkali, alkaline earth, heavy metal and transitional metals. The specific fluorescence response of the optical sensor is attributed to the coordination between Hg(II) and sulfonic group in the H-acid immobilized in the LDH matrix, which was verified by NMR spectroscopy and UV–vis spectra. In addition, density functional theory (DFT) calculation further confirms that the coordination occurs between one Hg2+ and two O atoms in the sulfonic group, which is responsible for the significant fluorescence quenching of the H-acid/LDH film. The results indicate that the H-acid/LDH composite film can be potentially used as a chemosensor for the detection of Hg2+ in the environmental and biomedical field.  相似文献   

11.
This work describes an electrochemical technique that is suitable for the rapid and sensitive screening of atenolol based on surface-stabilized bilayer lipid membranes (s-BLMs) composed from egg phosphatidylcholine (PC). The interactions of atenolol with s-BLMs produced electrochemical ion current increases that reproducible appeared within a few seconds after the exposure of the membranes to the drug. The current signal increase was related to the concentration of atenolol in bulk solution in the micromolar range. The present lipid film-based sensor provided fast response (i.e. on the order of a few seconds) to alterations of atenolol concentration (20 to 200 micro M) in electrolyte solution. ssDNA incorporated into s-BLMs can interact with atenolol, and decreased the detection limit of this drug by one order of magnitude. The oligomers used were single stranded deoxyribonucleic acids: thymidylic acid icosanucleotide terminated with a C-16 alkyl chain to assist incorporation into s-BLMs (5'-hexadecyl-deoxythymidylic acid icosanucleotide, dT(20)-C(16)). The electrochemical transduction of the interactions of atenolol with s-BLMs was applied in the determination of these compounds in pharmaceutical preparations by using the present minisensor.  相似文献   

12.
An ultrasensitive and highly selective electrochemical sensor for the determination of p-nitrophenol (p-NP) was developed based on electrochemically treated nano polypyrrole/sodium dodecyl sulphate film (ENPPy/SDS film) modified glassy carbon electrode. The nano polypyrrole/sodium dodecyl sulphate film (NPPy/SDS film) was prepared and treated electrochemically in phosphate buffer solution. The surface morphology and elemental analysis of treated and untreated NPPy/SDS film were characterized by FESEM and EDX analysis, respectively. Wettability of polymer films were analysed by contact angle test. The hydrophilic nature of the polymer film decreased after electrochemical treatment. Effect of the pH of electrolyte and thickness of the ENPPy/SDS film on determination of p-NP was optimised by cyclic voltammetry. Under the optimised conditions, the p-NP was determined from the oxidation peak of p-hydroxyaminophenol which was formed from the reduction of p-NP in the reduction segment of cyclic voltammetry. A very good linear detection range (from 0.1 nM to 100 μM) and the best LOD (0.1 nM) were obtained for p-NP with very good selectivity. This detection limit is below to the allowed limit in drinking water, 0.43 μM, proposed by the U.S. Environmental Protection Agency (EPA) and earlier reports. Moreover, ENPPy/SDS film based sensor exhibits high sensitivity (4.4546 μA μM−1) to p-NP. Experimental results show that it is a fast and simple sensor for p-NP.  相似文献   

13.
This paper describes a new gas-chrormatography with electron capture detection (GC-ECD) method for determination of some pyrethroids in milk samples. The extraction of the pyrethroids was carried out by liquid–liquid extraction with clean-up by precipitation at low temperature, without additional stages for removal of fat interferences. The method was efficient with recoveries of 93.0 ± 0.1% for cipermethrin and 84.0 ± 0.3% for deltamethrin. The quantification limits were 0.75 μg L−1 for both pyrethroids. The method was simple, of easy execution, and used only small quantities of organic solvent. After optimization and validation, the method was used for the determination of residues of the pyrethroids cipermethrin and deltamethrin in milk and in lactea drink commercialized in Viçosa (MG, Brazil). Some samples presented contamination with deltamethrin at levels below the maximum contamination limits established by the FAO.  相似文献   

14.
We report on recent advances of our immunoassay for the hormone progesterone in cows milk. Detection is based on total internal reflectance fluorescence (TIRF), the binding-inhibition assay with an immobilized progesterone derivative, and a commercially available monoclonal antibody to progesterone as biological recognition element. The fully automated River Analyzer (RIANA) biosensor for unattended, cost-effective, and continuous monitoring of environmental pollution therefore was adapted for sensitive determination of progesterone in milk. First, the sensitivity and robustness of the existing progesterone assay for water analysis were improved, resulting in a detection limit (LOD) of only 0.2 pg mL–1 and a quantification limit (LOQ) of only 2.0 pg mL–1. These extraordinary results are the lowest detection and quantification limits for progesterone determination using biosensors yet reported in the literature. Second, the accurate indicator of ovulation was calibrated and detected in three different types of milk (UHT milk, fresh milk, and raw milk). For commercial milk and randomly procured raw milk nominal levels of progesterone are typically in the range 5–15 ng mL–1. Limits of detection (LOD) achieved for added progesterone (i.e. spiked samples) were between 45.5 and 56.1 pg mL–1 depending on milk type. Having in mind the 1:10 dilution factor, these results are still a success. For the first time a commercially available antibody was incorporated into an immunoassay for progesterone detection in bovine milk, giving a detection limit below 1 ng mL–1 for a fully automated biosensor. Thus the outstanding progress made with this biosensor in environmental monitoring and water analysis has now been successfully adapted to milk analysis for use in the field of reproduction management.Dedicated to the memory of Wilhelm Fresenius.  相似文献   

15.
A simple electrochemical sensor based on a molecularly imprinted polymer film as the recognition element was developed for ractopamine (RAC) detection. This is the first report of a RAC-imprinted film on a gold electrode surface, synthesized through an electrochemical method using o-aminothiophenol as the functional monomer. The imprinting mechanism and experimental parameters affecting the capability of the imprinted film are discussed here. The sensor was successfully applied with constant potential amperometry for RAC detection in an indirect process with potassium ferricyanide as an electrochemical probe. The sensor had a rapid equilibrium time (120?s), high binding affinity and selectivity towards RAC, and with good reproducibility and stability. Under the experimental conditions applied, a linear relationship between the relative amperometric response and RAC ranged from 2.0?×?10(-7) to 1.4?×?10(-6)?mol?L(-1), with a lower limit of detection (LOD) of 2.38?×?10(-8)?mol?L(-1) (signal to noise ratio?=?3). The sensor was tested with feed samples spiked with trace amounts of RAC, with good recoveries between 87.4 and 90.5?%.  相似文献   

16.
Huang H  Li L  Zhou G  Liu Z  Ma Q  Feng Y  Zeng G  Tinnefeld P  He Z 《Talanta》2011,85(2):1013-1019
Melamine that can cause serious damage to the organs of animal or human beings was found to bind to polythymine via hydrogen bonding. With this novel discovery, colorimetric detection of melamine based on label-free and labeled gold nanoparticles was developed, respectively. Both of the methods revealed good selectivity for melamine over other components that may exist in milk and good anti-influence ability. The raw milk samples were pretreated according to the National standard method combined with a solid phase extraction monolithic column. The accurate quantification of melamine as low as 41.7 nM and 46.5 nM was obtained, respectively. It also guarantees fast and reliable readout with naked eyes, making visual detection possible. Further comparison between label-free and labeled based methods was discussed in this paper.  相似文献   

17.
A high-performance liquid chromatography-fluorescence detection method was optimized and validated to determine tetracyclines residues in bovine milk. Post-column derivatization using metal complexation in non-aqueous reagent increased the fluorescence of chelates by a factor up to 2.54 compared to water (signal-to-noise ratio enhancement). Overall recoveries ranged from 61 to 115%, with RSDr from 5 to 15% (n = 54). Detection limits ranged from 5 to 35 μg kg−1. Limits of quantification were established at 50 μg kg−1. Decision limits (CCα) were 109, 108 and 124 μg kg−1 and detection capabilities (CCβ) 119, 117 and 161 μg kg−1 for oxytetracycline, tetracycline and chlortetracycline, respectively. The method was applied successfully in a national monitoring program.  相似文献   

18.
A global optimizer has been developed, capable of computing the optimal configuration in a probe for spatially resolved reflectance spectroscopy (SRS). The main objective is to minimize the number of detection fibers, while maintaining an accurate estimation of both absorption and scattering profiles. Multiple fibers are necessary to robustify the estimation of optical properties against noise, which is typically present in the measured signals and influences the accuracy of the inverse estimation. The optimizer is based on a robust metamodel-based inverse estimation of the absorption coefficient and a reduced scattering coefficient from the acquired SRS signals. A genetic algorithm is used to evaluate the effect of the fiber placement on the performance of the inverse estimator to find the bulk optical properties of raw milk. The algorithm to find the optimal fiber placement was repeatedly executed for cases with a different number of detection fibers, ranging from 3 to 30. Afterwards, the optimal designs for each considered number of fibers were compared based on their performance in separating the absorption and scattering properties, and the significance of the differences was tested. A sensor configuration with 13 detection fibers was found to be the combination with the lowest number of fibers which provided an estimation performance which was not significantly worse than the one obtained with the best design (30 detection fibers). This design resulted in the root mean squared error of prediction (RMSEP) of 1.411 cm−1 (R2 = 0.965) for the estimation of the bulk absorption coefficient values, and 0.382 cm−1 (R2 = 0.996) for the reduced scattering coefficient values.  相似文献   

19.
A new resistance-type sensor based on Prussian blue film has been fabricated for the detection of chlorobenzene vapor. The effect of Prussian blue preparation conditions on the response of sensor was studied. The sensor exhibited good response and selectivity to chlorobenzene vapor. The sensor prepared with Fe2(SO4)3 at 298 K has response 8.5 at operating voltage of 10 V. The selectivity of the sensor to chlorobenzene against all other tested gases is exceeding almost by 5.6 times. The sensor showed linear response to chlorobenzene vapor in the concentration range of 24–169 ppm at room temperature and at a 10 V operating voltage. The response and recovery time of the sensor was about 18 and 12 s, respectively. Sensor stability test indicated the sensor had a good stability. Furthermore, seven real samples of chlorobenzene vapor was measured using the sensor. The relative error was in the range of about ±1.3%.  相似文献   

20.
A novel piezoelelctric biosensor has been developed for cholera toxin (CT) detection based on the analyte-mediated surface-agglutination of ganglioside (GM1)-functionalized liposomes. To achieve a CT-specific agglutination at the surface, the gold electrode is modified by a GM1-functionalized supported lipid membrane via spontaneous spread of the liposomes on a self-assembled monolayer of a long-chain alkanethiol. In the presence of CT, the GM1-incorporated liposomes in assay medium will rapidly specifically agglutinate at the electrode surface through the binding of CT to GM1 on the electrode surface and the liposome interface. This results in an enormous mass loading on the piezoelelctric crystal as well as a significant increase of density and viscosity at the interface, thereby generating a decrease in frequency of the piezoelelctric crystal. The combination of mass loading with interfacial change in the surface-agglutination reaction allows the developed piezoelelctric biosensor to show substantial signal amplification in response to the analyte CT. The detection limit can be achieved as low as 25 ng mL−1 CT. This is the first demonstration on CT detection based on specific surface-agglutination of GM1-modified liposomes. The supported lipid layer based sensing interface can be prepared readily and renewably, making the developed technique especially useful for simple, reusable and sensitive determination of proteins.  相似文献   