首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A method to quantify sub-ppm levels of formaldehyde in acetone has been developed and it is reported here. In this method, the different reactivities and stabilities of sulfite with formaldehyde and acetone are used to separate the two carbonyl compounds. Sulfite reacts with formaldehyde to form hydroxymethanesulfonate (HMS), the non-volatile and stable nature of which allows its separation from bulk acetone solvent. The resulting HMS is then converted back to formaldehyde under basic conditions, and formaldehyde is derivatized with 2,4-dinitrophenylhydrazine (DNPH) and quantified in its DNP hydrazone form using high-performance liquid chromatography-UV detection. The method detection limit at the 99% confidence level was 0.051 mg L−1. A batch of samples can be processed within 4 h. The method has been applied to quantify the amount of formaldehyde in an analytical-grade acetone and in a commercial nail polish remover and the level of formaldehyde was found to be 0.175 and 0.184 mg L−1, respectively.  相似文献   

2.
Liu JF  Peng JF  Chi YG  Jiang GB 《Talanta》2005,65(3):705-709
Using ionic liquid as extraction solvent and 2,4-dinitrophenylhydrazine (DNPH) as derivative agent, formaldehyde in shiitake mushroom was determined by liquid-phase microextraction coupled with high-performance liquid chromatography (HPLC). Shiitake mushroom was leached with water and filtrated, then the formaldehyde in filtrate was derivatized with DNPH and extracted simultaneously into a 10 μl drop of ionic liquid suspended on the tip of the microsyringe, and finally injected into the HPLC system for determination. The proposed procedure has a detection limit of 5 μg l−1 formaldehyde in extraction solution, thus the mushroom sample filtrate could be diluted with a large ratio to eliminate the influence of sample matrix. The method has a relative standard deviation of 3.5% between days for 53.5 μg l−1 formaldehyde standards. High contents of formaldehyde (119-494 μg g−1 wet weight), which is harmful for human beings, were detected in shiitake mushroom. Therefore, strategies must be taken to prevent the accumulation and strictly control the content of formaldehyde in shiitake mushroom.  相似文献   

3.
In this paper, a novel detection reagent for formaldehyde determination is proposed, and is applied to a simple and highly sensitive flow injection method for the spectrophotometric determination of formaldehyde. The method is based on the reaction of formaldehyde with methyl acetoacetate in the presence of ammonia. The increase in the absorbance of the reaction product was measured at 375 nm. An inexpensive light emitting diode (LED)-based UV detector (375 nm) was, for the first time, used. Under the optimized experimental conditions, formaldehyde in an aqueous solution was determined over the concentration range from 0.25 to 20.0 × 10−6 M with a liner calibration graph; the limit of detection (LOD) of 5 × 10−8 M (1.5 μg L−1) was possible. The relative standard deviation of 12 replicate measurements of 5 × 10−6 M formaldehyde was 1.2%. Maximum sampling throughput was about 21 samples/h. The effect of potential interferences such as metals, organic compounds and other aldehyde was also examined. The analytical performance for formaldehyde determination was compared with those obtained by the conventional acetylacetone method, which uses visible absorption spectrophotometry. Finally, the proposed method was successfully applied to the determination of formaldehyde in natural water samples.  相似文献   

4.
A modification of the Trautz-Schorigin reaction into a flow-injection analysis configuration is described. Different approaches were used at the optimization of chemiluminescence determination of formaldehyde in water based on the reaction of formaldehyde, gallic acid and hydrogen peroxide in an alkaline solution. Detection system with a 218 μl chemiluminescence cell was optimized by both a one-variable-at-a-time method, and a modified simplex method. A calibration graph is linear in the concentration range 4 × 10−8 to 1 × 10−5 M HCHO. The detection limit of formaldehyde for a signal-to-noise ratio of 3 is 4 × 10−8 M. The relative standard deviations for 15 repeated measurements of 1 × 10−6 and 5 × 10−6 mol l−1 HCHO are 4.32 and 3.33%, respectively. The analysis time is 1.5 min. The method was applied to the determination of formaldehyde in urban rainwater. A comparison of results found by proposed method with those obtained by fluorimetric reference method provided a good agreement.  相似文献   

5.
In this article, a new ligandless dispersive liquid-liquid microextraction method has been developed for preconcentration of trace quantities of silver as a prior step to its determination by flame atomic absorption spectrometry. In the proposed approach, carbon tetrachloride and ethanol were used as extraction and dispersive solvents. Several factors that may be affected on the extraction process, like, extraction solvent, disperser solvent, the volume of extraction and disperser solvent, pH of the aqueous solution and extraction time were optimized. Under the optimal conditions, the calibration curve was linear in the range of 5.0 ng mL−1 to 2.0 μg mL−1 of silver with R2 = 0.9995 (n = 9) and detection limit based on three times the standard deviation of the blank (3Sb) was 1.2 ng mL−1 in original solution. The relative standard deviation for eight replicate determination of 0.5 μg mL−1 silver was ±1.5%. The high efficiency of dispersive liquid-liquid microextraction to carry out the determination of silver in complex matrices was demonstrated. The proposed method has been applied for determination of trace amount of silver in standard and water samples with satisfactory results.  相似文献   

6.
A simple solvent microextraction method termed vortex-assisted liquid–liquid microextraction (VALLME) coupled with gas chromatography micro electron-capture detector (GC-μECD) has been developed and used for the pesticide residue analysis in water samples. In the VALLME method, aliquots of 30 μL toluene used as extraction solvent were directly injected into a 25 mL volumetric flask containing the water sample. The extraction solvent was dispersed into the water phase under vigorously shaking with the vortex. The parameters affecting the extraction efficiency of the proposed VALLME such as extraction solvent, vortex time, volumes of extraction solvent and salt addition were investigated. Under the optimum condition, enrichment factors (EFs) in a range of 835–1115 and limits of detection below 0.010 μg L−1 were obtained for the determination of target pesticides in water. The calculated calibration curves provide high levels of linearity yielding correlation coefficients (r2) greater than 0.9958 with the concentration level ranged from 0.05 to 2.5 μg L−1. Finally, the proposed method has been successfully applied to the determination of pesticides from real water samples and acceptable recoveries over the range of 72–106.3% were obtained.  相似文献   

7.
Manju Gupta 《Talanta》2009,80(2):526-385
A simple and rapid method has been reported for the determination of carbonyl compounds involving reaction with 2,4-dinitrophenylhydrazine and extraction of hydrazones with water-miscible organic solvent acetonitrile when the phase separation occurs by addition of ammonium sulphate, a process called salt-assisted liquid-liquid microextraction. The extract was analyzed by high-performance liquid chromatography with UV detection at 360 nm. The procedure has been optimized with respect to solvent suitable for extraction, salt for phase separation between water and organic solvent, reaction temperature and reaction time. The method has been validated when a linear dynamic range was obtained between the amount of analyte and peak area of hydrazones in the range 7 μg-15 mg L−1, the correlation coefficient over 0.9964-0.9991, and the limit of detection in the range 0.58-3.2 μg L−1. Spiked water samples have been analyzed with adequate accuracy, and application of the method has been demonstrated in the analysis of benzaldehyde formed as oxidation product in pharmaceutical preparation where benzyl alcohol is used as preservative, and for a keto drug dexketoprofen.  相似文献   

8.
A new continuous method for the determination of formaldehyde in air is described. A cylindrical wet effluent diffusion denuder is used for the collection of formaldehyde from air into a thin film of absorption liquid (distilled-deionized water). Formaldehyde in the denuder concentrate is on-line detected employing a chemiluminescence flow method based on a reaction of formaldehyde and gallic acid with hydrogen peroxide in an alkaline solution. The collection efficiency of formaldehyde is quantitative at the air flow rate of 0.5 L min−1 (absorption liquid flow rate of 336 μL min−1). The limit of detection (S/N = 3) is 0.60 μg m−3 HCHO (0.49 ppb). The calibration graph is linear up to 300 μg m−3 HCHO (244 ppb). The relative standard deviations of chemiluminescence method for 1 × 10−6 and 5 × 10−6 M HCHO are 2.87% and 1.49%, respectively. Acetaldehyde interferes negligible, other compounds do not interfere. The method was employed for formaldehyde measurement in ambient air. The comparison measurement illustrates the good agreement of results obtained by proposed method with those obtained by reference fluorimetric method.  相似文献   

9.
A simple and rapid method has been reported for the determination of carbonyl compounds involving sample preparation by headspace single drop microextraction using 1-butanol as extraction solvent containing 2,4-dinitrophenylhydrazine for hydrazone formation, and direct transfer of the drop into the injector for high-performance liquid chromatography with diode array detection. An angle-cut polytetrafluoroethylene sleeve, 3 mm × 0.5 mm, was fixed at the tip of the syringe needle and this allowed the use of 7 μL drop of solvent drop for extraction and derivatization. The procedure has been optimized with respect to suitable solvent for headspace drop formation, drop volume, concentration of reagent, sample temperature, reaction time, and headspace-to-sample volume ratio. The method has been validated when rectilinear relationship was obtained between the amount of analyte and peak area ratio of hydrazones in the range 0.01-15 mg L−1, the correlation coefficient over 0.996-0.999, and the limit of detection in the range 1.7-24.1 μg L−1. Spiked real samples have been analyzed with adequate accuracy, and application has been demonstrated of the method for analysis of carbonyl compounds formed as oxidation products.  相似文献   

10.
A simple, rapid, and efficient method, based on surfactant assisted dispersive liquid-liquid microextraction (SA-DLLME), followed by high performance liquid chromatography (HPLC) has been developed for the extraction and determination of chlorophenols as model compounds in environmental water samples. A conventional cationic surfactant called cethyltrimethyl ammonium bromide (CTAB) was used as a disperser agent in the proposed approach. Thirty-five microliter of 1-octanol as an extraction solvent was injected rapidly into 11 mL aqueous sample containing 0.09 mmol L−1 of CTAB, the mixture was then shaken for 3 min to disperse the organic phase. Having the extraction procedure been completed, the mixture was centrifuged and 20 μL of collected phase was injected into HPLC for subsequent analysis. Some parameters such as the type and volume of the extraction solvent, the type and concentration of surfactant, pH, ionic strength, shaking time, extraction temperature and centrifugation time were optimized. The preconcentration factors (PFs) in a range of 187-353 were obtained under the optimum conditions. The linear range, detection limit (S/N = 3), and precision (n = 5) were 0.2-200, 0.1 μg L−1, and 4.7-6.9%, respectively. Tap water, sea water and mineral water samples were successfully analyzed for the existence of chlorophenols using the proposed method.  相似文献   

11.
Farajzadeh MA  Djozan D  Khorram P 《Talanta》2011,85(2):1135-1142
A novel sample preparation technique, the microextraction method based on a dynamic single drop in a narrow-bore tube, coupled with gas chromatography-flame ionization detection (GC-FID) is presented in this paper. The most important features of this method are simplicity and high enrichment factors. In this method, a microdrop of an extraction solvent assisted by an air bubble was repeatedly passed through a narrow-bore closed end tube containing aqueous sample. It has been successfully used for the analysis of some pesticides as model analytes in aqueous samples. Parameters affecting the method's performance such as selection of extraction solvent type and volume, number of extractions, volume of aqueous sample (tube length), and salt effect were studied and optimized. Under the optimal conditions, the enrichment factors (EFs) for triazole pesticides were in the range of 141-214 and the limits of detection (LODs) were between 2 and 112 μg L−1. The relative standard deviations (C = 1000 μg L−1, n = 6) were obtained in the range of 2.9-4.5%. The recoveries obtained for the spiked well water and grape juice samples were between 71 and 106%. Low cost, relatively short sample preparation time and less solvent consumption are other advantages of the proposed method.  相似文献   

12.
In this work, a solid phase spectrophotometric method in association with flow injection analysis for formaldehyde determination has been developed with direct measurement of light-absorption in C18 material. The 3,5-diacetyl-1,4-dihydrolutidine produced from the reaction between formaldehyde and fluoral P was quantitatively retained on C18 support and the spectrophotometric detection was performed simultaneously at 412 nm. The retained complex was quickly eluted from C18 material with the eluent stream consisting of a 50% (v/v) ethanol solution. The results showed that the proposed method is simple, rapid and the analytical response is linear in the concentration range of 0.050-1.5 mg L−1. The limit of detection was estimated as 30 μg L−1 and the R.S.D. 2.2% using a sample volume of 625 μL. The system presented an analytical throughput of 20 determinations per hour. The method was successfully applied in the determination of formaldehyde in ethanol fuel.  相似文献   

13.
Ultrasound-assisted dispersive liquid–liquid microextraction coupled with high-performance liquid chromatography-fluorescence detection was used for the extraction and determination of three biogenic amines including octopamine, tyramine and phenethylamine in rice wine samples. Fluorescence probe 2,6-dimethyl-4-quinolinecarboxylic acid N-hydroxysuccinimide ester was applied for derivatization of biogenic amines. Acetonitrile and 1-octanol were used as disperser solvent and extraction solvent, respectively. Extraction conditions including the type of extraction solvent, the volume of extraction solvent, ultrasonication time and centrifuging time were optimized. After extraction and centrifuging, analyte was injected rapidly into high-performance liquid chromatography and then detected with fluorescence. The calibration graph of the proposed method was linear in the range of 5–500 μg mL−1 (octopamine and tyramine) and 0.025–2.5 μg mL−1 (phenethylamine). The relative standard deviations were 2.4–3.2% (n = 6) and the limits of detection were in the range of 0.02–5 ng mL−1. The method was applied to analyze the rice wine samples and spiked recoveries in the range of 95.42–104.56% were obtained. The results showed that ultrasound-assisted dispersive liquid–liquid microextraction was a very simple, rapid, sensitive and efficient analytical method for the determination of trace amount of biogenic amines.  相似文献   

14.
Dichlorodiphenyltrichloroethane,1,1,1-trichloro-2,2-bis(p-chlorophenyl)ethane (DDT) and its main metabolites have been paid much more attention, and present paper describes a new process for the rapid determination of such pollutants in environmental water samples based on dispersive liquid–liquid microextraction (DLLME) and high performance liquid chromatography with ultraviolet detector, which has merits such as high enrichment factor and sensitivity, low cost and easy to operate. Significant parameters such as extraction solvent and dispersive solvent type and volume, pH, extraction time and centrifuging time, which would have important impact on the enrichment of target pollutants, have been investigated in detail. The results exhibited that excellent performance could be achieved with carbon tetrachloride and acetonitrile as the extraction solvent and dispersive solvent, respectively. Under the optimal conditions, excellent linear relationship was gained in the range of 1.0–50 μg L−1, and detection limits were in the range of 0.32–0.51 μg L−1. The precisions of the proposed method were in the range of 2.80–7.50% (RSD). The proposed method was validated with real water samples, and the results indicated the spiked recoveries were in the range of 85.58–119.6% and the established method was very good and competitive in the determination of DDT and its metabolites.  相似文献   

15.
A rapid and effective preconcentration method for extraction of rhodamine 6G was developed by using a dispersive liquid-liquid microextraction (DLLME) prior to UV-vis spectrophotometry. In this extraction method, a suitable mixture of acetone (disperser solvent) and chloroform (extractant solvent) was injected rapidly into a conical test tube containing aqueous solution of rhodamine 6G. Therefore, a cloudy solution was formed. After centrifugation of the cloudy solution, sedimented phase was evaporated, reconstituted with methanol and measured by UV-vis spectrophotometry. Different operating variables such as type and volume of extractant solvent, type and volume of disperser solvent, pH of the sample solution, salt concentration and extraction time were investigated. The optimized conditions (extractant solvent: 300 μL of chloroform, disperser solvent: 3 mL of acetone, pH: 8 and without salt addition) resulted in a linear calibration graph in the range of 5-900 ng mL−1 of rhodamine 6G in initial solution with R2 = 0.9988 (n = 5). The Limits of detection and quantification were 2.39 and 7.97 ng mL−1, respectively. The relative standard deviation for 50 and 250 ng mL−1 of rhodamine 6G in water were 2.88% and 1.47% (n = 5), respectively. Finally, the DLLME method was applied for determination of rhodamine 6G in different industrial waste waters.  相似文献   

16.
Dispersive liquid-liquid microextraction (DLLME) coupled with high-performance liquid chromatography-variable wavelength detector (HPLC-VWD) was developed for extraction and determination of chloramphenicol (CAP) and thiamphenicol (THA) in honey. In this extraction method, 1.0 mL of acetonitrile (as dispersive solvent) containing 30 μL 1,1,2,2-tetrachloroethane (as extraction solution) was rapidly injected by syringe into a 5.00-mL water sample containing the analytes, thereby forming a cloudy solution. After extraction, phase separation was performed by centrifugation and the enriched analytes in the sedimented phase were determined by HPLC-VWD. Some important parameters, such as the nature and volume of extraction solvent and dispersive solvent, extraction time, sample solution pH, sample volume and salt effect were investigated and optimized. Under the optimum extraction condition, the method yields a linear calibration curve in the concentration range from 3 to 2000 μg kg−1 for target analytes. The enrichment factors for CAP and THA were 68.2 and 87.9, and the limits of detection (S/N = 3) were 0.6 and 0.1 μg kg−1, respectively. The relative standard deviations (RSDs) for the extraction of 10 μg kg−1 of CAP and THA were 4.3% and 6.2% (n = 6). The main advantages of DLLME-HPLC method are simplicity of operation, rapidity, low cost, high enrichment factor, high recovery, good repeatability and extraction solvent volume at microliter level. Honey samples were successfully analyzed using the proposed method.  相似文献   

17.
Zhao RS  Lao WJ  Xu XB 《Talanta》2004,62(4):751-756
In the present work, a novel method for the determination of trihalomethanes (THMs) such as chloroform, dichlorobromomethane, chlorodibromomethane and bromoform in drinking water has been described. It is based on coupling headspace liquid-phase microextraction (HS-LPME) with gas chromatography-electron capture detector (GC-ECD). A microdrop of organic solvent at the tip of a commercial microsyringe was used to extract analytes from aqueous samples. Three organic solvents—xylene, ethylene glycol and 1-octanol—were compared and 1-octanol was the most sensitive solvent for the analytes. Extraction conditions such as headspace volume, extraction time, stirring rate, content of NaCl and extraction temperature were found to have significant influence on extraction efficiency. The optimized conditions were 15 ml headspace volume in a 40 ml vial, 10 min extraction time and 800 rpm stirring rate at 20 °C with 0.3 g ml−1 NaCl. The linear range was 1-100 μg l−1 for THMs. The limits of detection (LODs) ranged from 0.15 μg l−1 (for dichlorobromomethane and chlorodibromomethane) to 0.4 μg l−1 (for chloroform); and relative standard deviations (RSD) for most of THMs at the 10 μg l−1 level were below 10%. Real samples collected from tap water and well water were successfully analyzed using the proposed method. The recovery of spiked water samples was from 101 to 112%.  相似文献   

18.
A sensitive FIA method was developed for the selective determination of formaldehyde in alcoholic beverages. This method is based on the reaction of Fluoral-P (4-amine-3-pentene-2-one) with formaldehyde, leading to the formation of 3,5-diacetyl-1,4-dihydrolutidine (DDL), which fluoresces at λex = 410 nm and λem = 510 nm. The analytical parameters were optimized by the response surface method using the Box-Behnken design. The proposed flow injection system allowed for the determination of up to 3.33 × 10−5 mol L−1 of formaldehyde with R.S.D. < 2.5% and a detection limit of 3.1 ng mL−1. The method was successfully applied to determine formaldehyde in alcoholic beverages, without requiring any sample pretreatment, and the results agreed with the reference at a 95% confidence level by paired t-test. In the optimized condition, the FIA system proved able to analyze up to 60 samples/h.  相似文献   

19.
A novel method, dispersive liquid-liquid microextraction (DLLME) coupled with high-performance liquid chromatography-variable wavelength detector (HPLC-VWD), has been developed for the determination of three phthalate esters (dimethyl phthalate (DMP), diethyl phthalate (DEP), and di-n-butyl phthalate (DnBP)) in water samples. A mixture of extraction solvent (41 μL carbon tetrachloride) and dispersive solvent (0.75 mL acetonitrile) were rapidly injected into 5.0 mL aqueous sample for the formation of cloudy solution, the analytes in the sample were extracted into the fine droplets of CCl4. After extraction, phase separation was performed by centrifugation and the enriched analytes in the sedimented phase were determined by HPLC-VWD. Some important parameters, such as the kind and volume of extraction solvent and dispersive solvent, extraction time and salt effect were investigated and optimized. Under the optimum extraction condition, the method yields a linear calibration curve in the concentration range from 5 to 5000 ng mL−1 for target analytes. The enrichment factors for DMP, DEP and DnBP were 45, 92 and 196, respectively, and the limits of detection were 1.8, 0.88 and 0.64 ng mL−1, respectively. The relative standard deviations (R.S.D.) for the extraction of 10 ng mL−1 of phthalate esters were in the range of 4.3-5.9% (n = 7). Lake water, tap water and bottled mineral water samples were successfully analyzed using the proposed method.  相似文献   

20.
Ultrasound-assisted emulsification-microextraction (USAEME) procedure was developed for the determination of selected polychlorinated biphenyls (PCBs) in 10 mL of water samples by gas chromatography-mass-selective detection. After determination of the most suitable solvent and extraction time, several other parameters including solvent volume, centrifugation time and ionic strength of the sample were optimized using a 23 factorial experimental design. The optimized USAEME procedure used 200 μL of chloroform as extraction solvent, 10 min of extraction with no ionic strength adjustment at 25 °C and 5 min of centrifugation at 4000 rpm. The limits of detection ranged from 14 ng L−1 (for PCB153) to 30 ng L−1 (for PCB101). Recoveries of PCBs from fortified distilled water are over 80% for three different fortification levels between 0.1 and 5 μg L−1 and relative standard deviations of the recoveries are below 10%. The performance of the proposed method was compared with those involving traditional liquid-liquid extraction (LLE) and solid phase extraction (SPE) on the real water samples (i.e., tap and well water as well as domestic and industrial wastewaters, etc.) and comparable efficiencies were obtained. The proposed USAEME procedure has been demonstrated to be viable, simple, rapid and easy to use for residue analysis of PCBs in water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号