首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A new technique for the determination of suspended particulate trace metals (P-metals >0.2 μm), such as Co, Ni, Cu, Zn, Cd and Pb, in open ocean seawater has been developed by using microwave digestion coupled with flow injection inductively coupled plasma mass spectrometry (FI-ICP-MS). Suspended particulate matter (SPM) was collected from 500 mL of seawater on a Nuclepore filter (0.2 μm) using a closed filtration system. Both the SPM and filter were completely dissolved by microwave digestion. Reagents for the digestion were evaporated using a clean evaporation system, and the metals were redissolved in 0.8 M HNO3. The solution was diluted with buffer solution to give pH 5.0 and the metals were determined by FI-ICP-MS using a chelating adsorbent of 8-hydroxyquinoline immobilized on fluorinated metal alkoxide glass (MAF-8HQ). The procedure blanks with a filter were found to be 0.048 ± 0.008, 10.3 ± 0.3, 0.27 ± 0.05, 3.3 ± 1.8, 0.02 ± 0.03 and 0.85 ± 0.09 ng L−1 for Co, Ni, Cu, Zn, Cd and Pb, respectively (n = 14). Detection limits defined as 3 times the standard deviation of the blanks were 0.023, 0.90, 0.14, 5.3, 0.078 and 0.28 ng L−1 for Co, Ni, Cu, Zn, Cd and Pb, respectively. Accuracy was evaluated using certified reference materials of chlorella (NES CRM No. 3) and marine sediment (HISS-1). The method was applied to the determination of vertical distributions for P-Co, Ni, Cu, Zn, Cd and Pb in the Western North Pacific.  相似文献   

2.
Inductively coupled plasma mass spectrometry (ICP-MS) and laser ablation ICP-MS (LA-ICP-MS) have been applied as the most important inorganic mass spectrometric techniques having multielemental capability for the characterization of solid samples in materials science. ICP-MS is used for the sensitive determination of trace and ultratrace elements in digested solutions of solid samples or of process chemicals (ultrapure water, acids and organic solutions) for the semiconductor industry with detection limits down to sub-picogram per liter levels. Whereas ICP-MS on solid samples (e.g. high-purity ceramics) sometimes requires time-consuming sample preparation for its application in materials science, and the risk of contamination is a serious drawback, a fast, direct determination of trace elements in solid materials without any sample preparation by LA-ICP-MS is possible. The detection limits for the direct analysis of solid samples by LA-ICP-MS have been determined for many elements down to the nanogram per gram range. A deterioration of detection limits was observed for elements where interferences with polyatomic ions occur. The inherent interference problem can often be solved by applying a double-focusing sector field mass spectrometer at higher mass resolution or by collision-induced reactions of polyatomic ions with a collision gas using an ICP-MS fitted with collision cell. The main problem of LA-ICP-MS is quantification if no suitable standard reference materials with a similar matrix composition are available. The calibration problem in LA-ICP-MS can be solved using on-line solution-based calibration, and different procedures, such as external calibration and standard addition, have been discussed with respect to their application in materials science. The application of isotope dilution in solution-based calibration for trace metal determination in small amounts of noble metals has been developed as a new calibration strategy. This review discusses new analytical developments and possible applications of ICP-MS and LA-ICP-MS for the quantitative determination of trace elements and in surface analysis for materials science.  相似文献   

3.
An analytical method using high-resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) for rapid simultaneous determination of 20 elements, including Na, Mg, Al, Ca, Ti, V, Mn, Fe, Co, Ni, Cu, Zn, Ga, As, Mo, Cd, Sn, Sb, Ba, and Pb elements, in residual oil was described. The sample was dissolved in HNO3 by microwave digestion, and then the above 20 elements in the solution were analyzed directly by HR-ICP-MS. Most of the spectral interferences could be avoided by measuring in the high-resolution mode. The matrix effect caused by the sample-digesting solution and corrected by Sc, Rh, and Bi as the internal standard elements was studied in detail. The optimum condition of the determination was also tested and discussed. The result showed that the detection limits of the method were in the range of 0.014 to 11.6 μg L−1; the relative standard deviation was less than 3.8% and recoveries in the samples were in the range of 88.4% to 108.0%. This method can be used to determine the trace elements in residual oil with the features of accurate, rapid, and convenient determination.  相似文献   

4.
 The aim of this intercomparison exercise was to assess the comparability of trace metal analyses of blank filters and of marine suspended particulate matter (SPM) on filters performed by laboratories in ICES member countries. Fifteen experts from the United Kingdom, Canada, France, Germany, the Netherlands, Norway, Poland, Russia, and the United States were invited to participate in this exercise for trace metal analyses of Cu, Pb, Zn, Cd, Al, Li, Fe, Mn, Ni and Co (tentative) in SPM. Each filter analysed in this project was an individual sample, the absolute loadings on the filters varying from 0.8 to 2 mg of SPM. The inter-laboratory means and the relative standard deviations (RSD) from the grand mean for the metals determined were: Al 67.5 mg/g, 8.3%, Fe 51.7 mg/g, 10.9%, Cd 1.5 μg/g, 22.7%, Cu 39 μg/g, 13.3%, Pb 38 μg/g, 34.7%, Mn 1060 μg/g, 13%, Ni 49.2 μg/g, 29%, Zn 182 μg/g, 32.5%, Li 52.8 μg/g, 26.1%, Co 15.4 μg/g, 23.6%. In general, the exercise demonstrated that it is possible for the various participants to collect very small amounts of SPM and analyse it by the different determination techniques. Compared to earlier exercises, comparability between laboratories was still difficult to achieve and limited. Received: 27 June 1996 Accepted: 15 August 1996  相似文献   

5.
A procedure to prepare crude oil samples as detergentless microemulsions was optimized and applied for the determination of Mo, Zn, Cd, Si, Ti, Ni, V, Fe, Mn, Cr and Co by ICP OES. Propan-1-ol was used as a co-solvent allowing the formation of a homogeneous and stable system containing crude oil and water. The optimum composition of the microemulsion was crude oil / propan-1-ol / water / concentrated nitric acid, 6 / 70 / 20 / 4 w/w/w/w. This simple sample preparation procedure together with an efficient sample introduction (using a Meinhard K3 nebulizer and a twister cyclonic spray chamber) allowed a fast quantification of the analytes using calibration curves prepared with analyte inorganic standards. In this case, Sc was used as internal standard for correction of signal fluctuations and matrix effects. Oxygen was used in the nebulizer gas flow in order to minimize carbon building up and background. Limits of detection in the ng g− 1 range were achieved for all elements. The methodology was tested through the analysis of one standard reference material (SRM NIST 1634c, Residual Fuel Oil) with recoveries between 97.9% and 103.8%. The method was also applied to two crude oil samples and the results were in good agreement with those obtained using the acid decomposition procedure. The precision (n = 3) obtained was below 5% and the results indicated that the method is well suited for oil samples containing low concentrations of trace elements.  相似文献   

6.
7.
High resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) in combination with a micro concentric nebulizer was studied in order to evaluate its suitability for the certification of the content of trace elements in high-purity metals. About 30 trace elements (analytes) were determined using solutions of high-purity Cd, Cu, Ga and Zn. The concentration levels of these matrices were varied as an experimental parameter. HR-ICP-MS was demonstrated to be very versatile and of high analytical performance. Effects of matrix concentrations on the analytical sensitivities and on the detection limits were investigated to find out optimal working conditions and to distiguish between different sources of matrix influences on sensitivities. As an example the gallium matrix was studied to obtain information about the matrix depositions on the cones of the mass spectrometer inlet system, using scanning electron microscopy and spectroscopical methods, including Raman spectroscopy.  相似文献   

8.
A simple and accurate low-blank method has been developed for the analysis of total dissolved copper, cadmium, lead, and iron in a small volume (1.3-1.5 mL per element) of seawater. Pre-concentration and salt-separation of a stable isotope spiked sample are achieved by single batch extraction onto nitrilotriacetate (NTA)-type Superflow(?) chelating resin beads (100-2400 beads depending on the element). Metals are released into 0.1-0.5 M HNO(3), and trace metal isotope ratios are determined by ICPMS. The benefit of this method compared to our previous Mg(OH)(2) coprecipitation method is that the final matrix is very dilute so cone-clogging and matrix sensitivity suppression are minimal, while still retaining the high accuracy of the isotope dilution technique. Recovery efficiencies are sensitive to sample pH, number of resin beads added, and the length of time allowed for sample-resin binding and elution; these factors are optimized for each element to yield the highest recovery. The method has a low procedural blank and high sensitivity sufficient for the analysis of pM-nM open-ocean trace metal concentrations. Application of this method to samples from the Bermuda Atlantic Time-Series Study station provides oceanographically consistent Cu, Cd, Pb, and Fe profiles that are in good agreement with other reliable data for this site. In addition, the method can potentially be modified for the simultaneous analysis of multiple elements, which will be beneficial for the analysis of large number of samples.  相似文献   

9.
Trace metals in fuels, except in the case of additives, are usually undesirable and normally they occur in very low concentrations in gasoline, requiring sensitive techniques for their determination. Coupling of electrothermal vaporization with inductively coupled plasma mass spectrometry minimizes the problems related to the introduction of organic solvents into the plasma. Furthermore, sample preparation as oil-in-water emulsions reduces problems related to gasoline analysis. In this work, a method for determination of Cu, Mn, Ni and Sn in gasoline is proposed. Samples were prepared by forming a 10-fold diluted emulsion with a surfactant (Triton X-100), after treatment with concentrated HNO3. The sample emulsion was pre-concentrated in the graphite tube by repeated pipetting and drying. External calibration was used with aqueous standards in a purified gasoline emulsion. Six samples from different gas stations were analyzed, and the analyte concentrations were found to be in the μg l−1 range or below. The limits of detection were 0.22, 0.02, 0.38 and 0.03 μg l−1 for Cu, Mn, Ni and Sn, respectively. The accuracy of the method was estimated using a recovery test.  相似文献   

10.
Menegário AA  Packer AP  Giné MF 《The Analyst》2001,126(8):1363-1366
Trace elements in small sample volumes of saliva were determined by coupling a high efficiency direct injection nebulizer to inductively coupled plasma mass spectrometry and employing quantification by isotope dilution. Aliquots of 0.4 ml of human saliva were mixed with 0.1 ml of concentrated nitric acid and diluted to 2 ml with water. Sample solutions were spiked with an isotopic solution enriched in 135Ba, 112Cd, 65Cu, 206Pb and 66Zn. The amount of each isotope added to the samples and the measurement procedure were adjusted to attain precise analytical results calculated from the isotope ratios 135Ba/138Ba, 112Cd/114Cd, 65Cu/63Cu, 206Pb/208Pb and 66Zn/68Zn. Data acquisition for Ba, Cu and Zn isotopes was performed for a single sample injection of 50 microl and in another sample injection the Cd and Pb isotopes were measured. Concentrations ranging from 5.0 to 16 microg l(-1) for Ba, from 0.50 to 1.1 microg l(-1) for Cd, from 6.0 to 50 microg l(-1) for Cu, from 0.8 to 18.8 microg l(-1) for Pb and from 46.0 to 230 microg l(-1) for Zn were found in saliva samples. Detection limits of 0.11, 0.03, 0.40, 0.05 and 0.59 microg l(-1) were determined for Ba, Cd, Cu, Pb and Zn, respectively. The concentrations found by isotope dilution were in agreement with those of the completely digested samples quantified by external calibration. The direct analysis of 30 samples per hour was attained with the proposed procedure, avoiding time-consuming digestion steps, contamination risks and matrix effects.  相似文献   

11.
Based on carbon nanofibers (CNFs) as a solid phase extraction adsorbent, a microcolumn preconcentration method coupled to inductively coupled plasma mass spectrometry (ICP–MS) was developed for the determination of trace elements (Mn, Co and Ni). The effect of various experimental parameters such as pH, sample flow rate and volume, elution solution and interfering ions on the retention of the studied ions have been investigated systematically. During all the steps of the experimental process, Mn, Co and Ni could be quantitatively sorbed on the microcolumn containing CNFs in the range of pH 6.0–9.0, and then eluted completely with 0.5 mol ml− 1 HNO3. A preconcentration factor of 150-fold was obtained. The detection limits for Mn, Co and Ni were 40, 0.4 and 8.0 pg ml− 1, respectively, with relative standard deviations less than 6.0%. In order to validate the proposed method, two certified reference materials of human hair (GBW 07601) and mussel (GBW 08571), and water sample were analyzed with satisfactory results. The recoveries were between 95.0 and 114%.  相似文献   

12.
A method is described for quantification of sulfur at low concentrations on the order of mg kg−1 in biodiesel and diesel fuels using isotope dilution and sector field inductively coupled plasma mass spectrometry (ID-SF-ICP-MS). Closed vessel microwave-assisted digestion was employed using a diluted nitric acid and hydrogen peroxide decomposition medium to reduce sample dilution volumes. Medium resolution mode was employed to eliminate isobaric interferences at 32S and 34S related to polyatomic phosphorus and oxygen species, and sulfur hydride species. The method outlined yielded respective limits of detection (LOD) and limits of quantification (LOQ) of 0.7 mg kg−1 S and 2.5 mg kg−1 S (in the sample). The LOD was constrained by instrument background counts at 32S but was sufficient to facilitate value assignment of total S mass fraction in NIST SRM 2723b Sulfur in Diesel Fuel Oil at 9.06 ± 0.13 mg kg−1. No statistically significant difference at a 95% confidence level was observed between the measured and certified values for certified reference materials NIST SRM 2773 B100 Biodiesel (Animal-Based), CENAM DRM 272b and NIST SRM 2723a Sulfur in Diesel Fuel Oil, validating method accuracy.  相似文献   

13.
Ion exclusion chromatograph (IEC) isotope dilution (ID) inductively coupled plasma mass spectrometry (ICP–MS) (IEC–ID–ICP–MS) was developed for measurement of dissolved silica in seawater, which was applied to production of certified reference materials (CRMs) of three concentration levels of nutrients (high, medium and low levels). IEC–ICP–MS has been employed to separate dissolved silica from seawater matrix. In the present study, in order to solve substantial problems due to spectral interference in ICP–MS and to improve the accuracy of IEC–ICP–MS beyond standard addition or conventional calibration methods, ID method was coupled with ICP-sector field mass spectrometry (operated under medium resolution,i.e., mm = 4000). In addition, effects of various operating parameters in ICP–MS on a silicon background level were also investigated to obtain lower background equivalent concentration (BEC). As a result, 3 ng g−1 of the BEC and 0.5 % of relative standard uncertainties were achieved in the analyses of dissolved silica in seawater samples at concentration levels from 4.0 mg kg -1 to 0.8 mg kg−1 as silicon. The developed method was successfully validated by analyses of an artificial seawater containing a known amount of silicate and the seawater certified reference material MOOS-2 produced by the National Research Council Canada.  相似文献   

14.
A novel automated off-line preconcentration system for trace metals (Al, Mn, Fe, Co, Ni, Cu, Zn, Cd, and Pb) in seawater was developed by improving a commercially available solid-phase extraction system SPE-100 (Hiranuma Sangyo). The utilized chelating resin was NOBIAS Chelate-PA1 (Hitachi High-Technologies) with ethylenediaminetriacetic acid and iminodiacetic acid functional groups. Parts of the 8-way valve made of alumina and zirconia in the original SPE-100 system were replaced with parts made of polychlorotrifluoroethylene in order to reduce contamination of trace metals. The eluent pass was altered for the back flush elution of trace metals. We optimized the cleaning procedures for the chelating resin column and flow lines of the preconcentration system, and developed a preconcentration procedure, which required less labor and led to a superior performance compared to manual preconcentration (Sohrin et al. [5]). The nine trace metals were simultaneously and quantitatively preconcentrated from ∼120 g of seawater, eluted with ∼15 g of 1 M HNO3, and determined by HR-ICP-MS using the calibration curve method. The single-step preconcentration removed more than 99.998% of Na, K, Mg, Ca, and Sr from seawater. The procedural blanks and detection limits were lower than the lowest concentrations in seawater for Mn, Ni, Cu, and Pb, while they were as low as the lowest concentrations in seawater for Al, Fe, Co, Zn, and Cd. The accuracy and precision of this method were confirmed by the analysis of reference seawater samples (CASS-5, NASS-5, GEOTRACES GS, and GD) and seawater samples for vertical distribution in the western North Pacific Ocean.  相似文献   

15.
A method is described for determination of selenium in sediment by isotope-dilution inductively coupled plasma mass spectrometry with an octapole reaction cell (ID–ICP–ORCMS). Sediment samples were digested with HNO3, HClO4, and HF, and the digestion included an elaborate evaporation process to remove bromine from the digested solution. Simple strong cation-exchange disk filtration was used to remove rare earth elements (REE) from the digested solution, because REE2+ seriously interfere with Se isotopes (i.e. 156Gd2+ with 78Se+, 160Gd2+ with 80Se+). Addition of acetic acid to the filtrate was examined to improve the sensitivity of ICP–ORCMS measurement of Se+ by means of a carbon-enhancement effect. The interfering for selenium isotopes were almost eliminated by use of H2 as reaction gas. Interference from BrH+ formed in the reaction cell was negligible because the Br was removed in the evaporation process. Approximately 99.5% of REE were removed by cation-exchange disk filtration yet more than 99% of Se remained in the filtrate solution. The intensity for Se+ was enhanced approximately fourfold by addition of 5% (v/v) of acetic acid whereas that for was barely enhanced. Measured 80Se/78Se ratios in unspiked digested solutions of the sample were in good agreement with that for an Se standard solution. The analytical results for Se in the certified reference materials MESS-3 and PACS-1 were in good agreement with their certified values, with small uncertainties.   相似文献   

16.
A robust and rapid method for the determination of natural levels of beryllium (Be) in seawater was developed to facilitate mapping Be concentrations in the ocean. A solid-phase extraction method using a silica gel column was applied for preconcentration and purification of Be in seawater prior to determination of Be concentrations with inductively coupled plasma mass spectrometry (ICP-MS). Be was quantitatively adsorbed onto silica gel from solutions with pH values ranging from 6.3 to 9, including natural seawater. The chelating agent ethylenediamine tetraacetic acid was used to remove other ions in the seawater matrix (Na, Mg, and Ca) that interfere with the ICP-MS analysis. The reproducibility of the method was 3% based on triplicate analyses of natural seawater samples, and the detection limit was 0.4 pmol kg−1 for 250 mL of seawater, which is sufficient for the analysis of seawater in the open ocean. The method was then used to determine the vertical profile of Be in the eastern North Pacific Ocean, which was found to be a recycled-type profile in which the Be concentration increased with depth from the surface (7.2 pmol kg−1 at <200 m) to deep water (29.2 pmol kg−1 from 3500 m to the bottom).  相似文献   

17.
采用同位素稀释电感耦合等离子体质谱(ID-ICP-MS)法测定了铅的含量,通过对茶叶标准物质(GBW-07605)中铅的测定,考察了方法的准确度和精密度,比较了同位素稀释法与普通外标定量法的测定结果。在5mLHNO3~0.5mLHF~1mLH2O2的消解体系中,ID-ICP-MS法测量茶叶中铅的回收率可达97.7%,相对标准偏差(RSD)小于1.2%。实验对市售的12种茶叶和10种蔬菜中Pb进行测定,铅含量符合相应国家标准的样品分别占总样品数的83%和90%。该法适合于植物样品中微量铅的测定。  相似文献   

18.
Slurry sampling electrothermal vaporization dynamic reaction cell inductively coupled plasma mass spectrometry (ETV-DRC-ICP-MS) has been applied to determine Fe, Co, Ni, Cu, and Zn in biological samples. The influences of instrument operating conditions and slurry preparation on the ion signals were reported. Pd was used as the modifier. The effectiveness of the ETV sample introduction technique and dynamic reaction cell in alleviating various spectral interferences in ICP-MS analysis has been demonstrated. This method has been applied to determine Fe, Co, Ni, Cu, and Zn in NIST SRM 1573a tomato leaves reference material and NRCC DORM-2 dogfish muscle reference material and also real samples such as a tea and a swordfish sample purchased locally. Since the sensitivities of the elements studied in slurry and aqueous solution were different, an analyte addition technique was used for the determinations. The analytical results of the reference materials agreed with the certified values. The precision between sample replicates was better than 6% for all determinations. The method detection limit estimated from analyte addition curves was 0.01, 0.006, 0.007, 0.004, and 0.006 μg g−1 for Fe, Co, Ni, Cu, and Zn, respectively, in the original biological samples.  相似文献   

19.
Inductively coupled plasma mass spectrometry (ICP-MS) was used in an isotope dilution mode to assay small-volume (0.25 ml) sediment pore waters for their uranium contents, using 236U as the spike. The only pretreatment required was a simple dilution by a factor of 20, which gave sufficient volume for three replicate analyses per sample. Rapid and accurate results were obtained for a variety of samples and standards, ranging in concentration from 0.05 to 10 ng U ml?1. A suite of 30 samples can be analysed in less than 6 h by this method. The relative standard deviation was better than 1.9%, with a detection limit, based on 3σ background, of 2 pg U ml?1 in solution (40 pg ml?1 in samples). Sea water is a difficult matrix for ICP-MS and thus the method is generally suitable for uranium determinations in many other sample solutions.  相似文献   

20.
A simple method is described for the determination of Cd, Cu, Mn, Ni, Pb and Zn in nails by using inductively coupled plasma mass spectrometry (ICP-MS) or electrothermal atomic absorption spectrometry (ETAAS). Prior to analysis, 10-20 mg of nail samples were accurately weighed into (15 mL) conical tubes. Then, 1 mL of 25% (w/v) tetramethylammonium hydroxide (TMAH) solution was added to the samples, incubated at room temperature overnight and then further diluted to 10 mL with 1% (v/v) HNO(3). After that, samples were directly analyzed. Rhodium was used as internal standard for ICP-MS analysis. Method detection limits (3 s, n=20) were 0.1, 3.0, 1.0, 4.5, 1.5, 5.0 ng g(-1) for Cd, Cu, Mn, Ni, Pb and Zn, respectively for ICP-MS, and 24, 26, 30, 143, 130 and 1000 ng g(-1), respectively for ETAAS. The key issue addressed here is the elimination of the acid digestion prior to analysis. Moreover, with the use of the proposed method there is a considerable improvement in the sample throughput comparing to the traditional methods using microwave-assisted acid sample digestion prior to analysis. For validation purposes, six ordinary nail samples were solubilized and then directly analyzed by ICP-MS and ETAAS, with no statistical difference between the two techniques at 95% level on applying the t-test.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号