共查询到20条相似文献,搜索用时 15 毫秒
1.
Carbon screen-printed electrodes (CSPE) modified with gold nanoparticles present an interesting alternative in the determination of antimony using differential pulse anodic stripping voltammetry. Metallic gold nanoparticles deposits have been obtained by direct electrochemical deposition. Scanning electron microscopy measurements show that the electrochemically synthesized gold nanoparticles are deposited in aggregated form. Any undue effects caused by the presence of foreign ions in the solution were also analyzed to ensure that common interferents in the determination of antimony by ASV. The detection limit for Sb(III) obtained was 9.44 × 10−10 M. In terms of reproducibility, the precision of the above mentioned method in %R.S.D. values was calculated at 2.69% (n = 10). The method was applied to determine levels of antimony in seawater samples and pharmaceutical preparations. 相似文献
2.
Carbon screen-printed electrodes (CSPE) modified with silver nanoparticles present an interesting alternative in the determination of lamotrigine (LTG) using differential pulse adsorptive stripping voltammetry.Metallic silver nanoparticle deposits have been obtained by electrochemical deposition. Scanning electron microscopy measurements show that the electrochemically synthesized silver nanoparticles are deposited in aggregated form.The detection limit for this analytical procedure was 3.72 × 10−7 M. In terms of reproducibility, the precision of the above mentioned method in %R.S.D. values was calculated at 2.58%.The method was applied satisfactorily to the determination of LTG in pharmaceutical preparations. 相似文献
3.
4.
This work exploited a sequential injection lab-on-valve (LOV) system for the determination of cadmium by anodic stripping voltammetry (ASV). A miniaturized electrochemical flow cell (EFC) was fabricated in LOV, in which a nafion coated bismuth film electrode was used as working electrode. The cadmium was electrodeposited on the electrode surface in bismuth solution, and measured with the subsequential stripping scan. Under optimal conditions, the proposed system responded linearly to cadmium concentrations in a range 2.0-100.0 μg L−1. The detection limit of this method was found to be 0.88 μg L−1. By loading a sample volume of 800 μL, a sampling frequency of 22 determinations h−1 was achieved. The repeatability expressed as relative standard derivation (R.S.D.) was 3.65% for 20 μg L−1 cadmium (n = 11). The established method was applied to analysis of trace cadmium in environmental water samples and the spiked recoveries were satisfactory. 相似文献
5.
Carbon and gold microdisc electrodes (30 and 10 μm, respectively) have been tested as substrates for in situ bismuth film plating from unstirred solutions of variable acetate buffer content and were subsequently used in the anodic stripping voltammetry determination of Pb(II) and Cd(II) ions. The effects of Bi(III) concentration, analyte accumulation time, stirring as well as supporting electrolyte content have been studied. Under optimal conditions good voltammetric responses were obtained by means of square wave anodic stripping voltammetry in unstirred analyte solutions of 5 × 10−8 to 10−6 M, even in the absence of added buffer. In an indicative application, Pb(II) ion levels were determined in tap water using bismuth-plated carbon microdisc electrodes. 相似文献
6.
Determination of trace metoclopramide by anodic stripping voltammetry with nafion modified glassy carbon electrode 总被引:4,自引:0,他引:4
A novel method is described for determination of metoclopramide (MCP) by second-derivative adsorptive anodic stripping voltammetry with a nafion-modified electrode. The stripping peak current is proportional to the concentration of MCP over the range 1.2×10−9–4.6×10−7 M. The detection limit is 8.0×10−11 M with 4-min accumulation. The method has been successfully applied to the determination of MCP in human serum. 相似文献
7.
Anodic stripping voltammetry at a new type of disposable bismuth-plated carbon paste mini-electrodes
A new type of disposable carbon paste mini-electrodes (CPmEs), with dimensions in the 50-300 μm range, have been fabricated by heat-shrinking the end-tip of plastic micropipette tips and filling them with carbon paste. The CPmEs have been characterized by microscopic and electrochemical means and tested as substrates for in situ plated Bi film electrodes (BiF-CPmEs), used in the determination of heavy metals by square wave anodic stripping voltammetry (SWASV). It was found that this new class of CPmEs combines the advantages of carbon paste electrodes (readily renewable surface and high surface area) with those of near-microelectrode behaviour (no stirring or electrolyte excess needed). During SWASV experiments in unstirred Pb(II) and Cd(II) solutions well-shaped stripping peaks were obtained whose height varied linearly with analyte concentration in the wide 1 × 10−8 to 10−6 M range, both in acetate buffer and unbuffered solutions. Under optimal conditions detection limits of 8 × 10−10 and 1.3 × 10−9 M were achieved for Pb(II) and Cd(II), respectively and in a trial application, these metal ions have been determined in a spiked tap water sample using a BiF-CPmE. 相似文献
8.
Clara Pérez-Ràfols Núria SerranoJosé Manuel Díaz-Cruz Cristina AriñoMiquel Esteban 《Analytica chimica acta》2016
Three different commercial carbon nanomaterial-modified screen-printed electrodes based on graphene, carbon nanotubes and carbon nanofibers were pioneeringly tested as electrode platforms for the plating with Sb film. They were microscopically and analytically compared to each other and to the most conventional unmodified carbon screen-printed electrode (SPCE). The obtained detection and quantification limits suggest that the in-situ antimony film electrode prepared from carbon nanofibers modified screen-printed electrode (SbSPCE-CNF) produces a better analytical performance as compared to the classical SPCE modified with antimony for Pb(II) and Cd(II) determination, approving its appropriateness for measuring low μg L−1 levels of the considered metals. In-situ SbSPCE-CNF was successfully used for the simultaneous determination of Pb(II) and Cd(II) ions, by means of differential pulse anodic stripping voltammetry, in a certified reference estuarine water sample with a very high reproducibility and good trueness. 相似文献
9.
Two sequential injection systems have been developed for adsorptive stripping voltammetric measurement. One is for substances adsorbing at mercury, e.g. riboflavin. In this case, a simple arrangement with only sample aspiration is needed. Reproducibility was 3% and detection limit 0.07 μM. The measuring system was applied to determination of riboflavin in vitamin pills and to study the photodegradation process of riboflavin in aqueous solutions. In the second case, metal ions were determined. They have to be complexed before deposition on the mercury surface. Thus, both the sample and the ligand have to be aspirated in the system. In this case, the reproducibility was ≈6% and the detection limit <0.1 ppm for cadmium, lead and copper when complexation with oxine was used. Dimethylglyoxime was used in determination of nickel and cobalt and nioxime complexes were used in determination of nickel and copper. With these complexing agents, the reproducibility was the same as with oxine, but the metals could be determined at concentrations lower than 0.01 ppm. Application of two ligands in a SIA system with AdSV detection was also studied. Simultaneous determination of copper, lead, cadmium and cobalt was possible by using oxine and dimethylglyoxime. Copper and nickel were simultaneously determined by using dimethylglyoxime and nioxime. 相似文献
10.
A sensitive voltammetric method is presented for the determination of tract levels of Mn (II) using carbon film electrodes fabricated from carbon resistors of 2 Ω. Determination of manganese was made by square wave cathodic stripping voltammetry (CSV), with deposition of manganese as manganese dioxide. Chronoamperometric experiments were made to study MnO2 nucleation and growth. As a result, it was found to be necessary to perform electrode conditioning at a more positive potential to initiate MnO2 nucleation. Under optimised conditions the detection limit obtained was 4 nM and the relative standard deviation for eight measurements of 0.22 nM was 5.3%. Interferences from various metal ions on the response CSV of Mn(II) were investigated, namely Cd(II), Ni(II), Cu(II), Cr(VI), Pb(II), Zn(II) and Fe(II). Application to environmental samples was demonstrated. 相似文献
11.
Mercury-thin film electrodes coated with a thin film of poly(ester sulphonic acid) (PESA) have been investigated for application in the analysis of trace heavy metals by square wave anodic stripping voltammetry using the batch injection analysis (BIA) technique. Different polymer dispersion concentrations in water/acetone mixed solvent are investigated and are characterised by electrochemical impedance measurements on glassy carbon and on mercury film electrodes. The influence of electrolyte anion, acetate or nitrate, on polymer film properties is demonstrated, acetate buffer being shown to be preferable for stripping voltammetry applications. Although stripping currents are between 30 and 70% less at the coated than at bare mercury thin film electrodes, the influence of model surfactants on stripping response is shown to be very small. The effect of the composition of the modifier film dispersion on calibration plots is shown; however, detection limits of around 5 nM are found for all modified electrodes tested. This coated electrode is an alternative to Nafion-coated mercury thin film electrodes for the analysis of trace metals in complex matrices, particularly useful when there is a high concentration of non-ionic detergents. 相似文献
12.
Roa G Ramírez-Silva MT Romero-Romo MA Galicia L 《Analytical and bioanalytical chemistry》2003,377(4):763-769
This work reports the use of and -cyclodextrin-modified carbon paste electrodes (CPE-CD and CPE-CD) to determine simultaneously Pb(II) and Cd(II) by means of the electrochemical technique known as anodic stripping voltammetry (ASV). Both modified electrodes displayed good resolution of the oxidation peaks of the said metals. Statistic analysis of the results strongly suggests that the CPE-CD exhibited a better analytical response that the CPE-CD, while the detection limits obtained for Pb(II) were 6.3×10–7 M for the CPE-CD and 7.14×10–7 M for the CPE-CD, whereas for Cd(II) they were 2.51×10–6 M for the CPE-CD and 2.03×10–6 M for the CPE-CD. 相似文献
13.
The applicability of commercial screen-printed gold electrodes (SPGEs) for the determination of Hg(II) in ambient water samples by square wave anodic stripping voltammetry has been demonstrated. Electrode conditioning procedures, chemical and instrumental variables have been optimized to develop a reliable method capable of measuring dissolved mercury in the low ng mL−1 range (detection limit 1.1 ng mL−1), useful for pollution monitoring or screening purposes. The proposed method was tested with the NIST 1641d Mercury in Water Standard Reference Material (recoveries 90.0–110%) and the NCS ZC 76303 Mercury in Water Certified Reference Material (recoveries 82.5–90.6%). Waste water samples from industrial origin and fortified rain water samples were assayed for mercury by the proposed method and by a reference ICP-MS method, with good agreement. Screen printing technology thus opens a useful way for the construction of reliable electrochemical sensors for decentralized or even field Hg(II) testing. 相似文献
14.
Determination of trace metals in Nile River and ground water by differential pulse stripping voltammetry 总被引:1,自引:0,他引:1
Zanaty R. Komy 《Mikrochimica acta》1993,111(4-6):239-249
The determination of trace metals in river water and ground water by DPSV is seriously disturbed by the presence of organic complexes. The influence of these substances can be eliminated by acidification of the samples with acids. Cd, Pb and Cu were determined at pH 1.1 (HNO3 medium) and Zn, Cd, Pb and Cu at pH 2 (HCl medium), in both the Nile river and ground water. Zn was determined at pH 3.5 in HCl and pH 4.5 in HNO3, after neutralizing the samples with NH3/NH4Cl buffer. Manganese could then be determined, after further addition of ammoniacal buffer solution up to pH 7.5 and 8.5. Ni and Co were determined in the adsorptive mode after formation of dimethylglyoximates at pH 9.2. The effect of pH on the stripping peaks of manganese was studied. Good agreement was observed between DPSV and AAS results for Zn, Cd, Pb, Cu and Mn, but the concentrations of Ni and Co were below the detection limits for AAS. Good agreement was obtained between DPSV results in HCl and HNO3 for Ni and Co. The results indicate that decomposition of organic complexes by acidification with HNO3 is better than in the case with HCl for Zn, Pb, Cu, Ni and Co, but HCl is better than HNO3 for Cd and Mn. 相似文献
15.
Flow injection (FI) and sequential injection (SI) systems with anodic stripping voltammetric detection have been exploited for simultaneous determination of some metals. A pre-plated mercury film on a glassy carbon disc electrode was used as a working electrode in both systems. The same film can be repeatedly applied for at least 50 analysis cycles, thus reducing the mercury consumption and waste. A single line FI voltammetric system using an acetate buffer as a carrier and an electrolyte solution was employed. An injected standard/sample zone was mixed with the buffer in a mixing coil before entering a flow cell. Metal ions were deposited on the working electrode by applying a potential of −1.1 V vs Ag/AgCl reference electrode. The stripping was performed by anodically scanning potential of working electrode to +0.25 V, resulting a voltammogram. Effects of acetate buffer concentration, flow rate and sample volume were investigated. Under the selected condition, detection limits of 1 μg l−1 for Cd(II), 18 μg l−1 for Cu(II), 2 μg l−1 for Pb(II) and 17 μg l−1 for Zn(II) with precisions of 2–5% (n=11) were obtained. The SI voltammetric system was similar to the FI system and using an acetate buffer as a carrier solution. The SI system was operated by a PC via in-house written software and employing an autotitrator as a syringe pump. Standard/sample was aspirated and the zone was then sent to a flow cell for measurement. Detection limits for Cd(II), Cu(II), Pb(II) and Zn(II) were 6, 3, 10 and 470 μg l−1, respectively. Applications to water samples were demonstrated. A homemade UV-digester was used for removing organic matters in the wastewater samples prior to analysis by the proposed voltammetric systems. 相似文献
16.
T.V. Titova 《Analytica chimica acta》2009,653(2):154-5628
A novel electrochemical methods namely standard free anodic stripping voltammetry and anodic stripping voltammetric titration are proposed for determination of dissolved sulfide concentration. 2Ag+ + S2− → Ag2S reaction is used to provide the information. The anodic stripping voltammetric response of unreacted silver-ions at the glassy carbon electrode is used as analytical signal. Results reliability and accuracy are confirmed by analysis of model solutions, spiked natural and tap waters and recovery study, with a recovery of 100 ± 5% (n = 7) obtained. The approaches show the detection limit (3σblank) of 2-5 × 10−10 mol L−1 and the relative standard deviation of 2-5% for repeated measurements. 相似文献
17.
Metal ion analysis in contaminated water samples using anodic stripping voltammetry and a nanocrystalline diamond thin-film electrode 总被引:1,自引:0,他引:1
Prerna Sonthalia 《Analytica chimica acta》2004,522(1):35-44
Boron-doped nanocrystalline diamond thin-film electrodes were employed for the detection and quantification of Ag (I), Cu (II), Pb (II), Cd (II), and Zn (II) in several contaminated water samples using anodic stripping voltammetric (ASV). Diamond is an alternate electrode that possesses many of the same attributes as Hg and, therefore, appears to be a viable material for this electroanalytical measurement. The nanocrystalline form has been found to perform slightly better than the more conventional microcrystalline form of diamond in this application. Differential pulse voltammetry (DPASV) was used to detect these metal ions in lake water, well water, tap water, wastewater treatment sludge, and soil. The electrochemical results were compared with data from inductively coupled plasma mass spectrometric (ICP-MS) and or atomic absorption spectrometric (AAS) measurements of the same samples. Diamond is shown to function well in this electroanalytical application, providing a wide linear dynamic range, a low limit of quantitation, excellent response precision, and good response accuracy. For the analysis of Pb (II), bare diamond provided a response nearly identical to that obtained with a Hg-coated glassy carbon electrode. 相似文献
18.
茜素红S/多壁碳纳米管修饰碳糊电极阳极溶出伏安法测定痕量铜 总被引:2,自引:0,他引:2
制备了茜素红S/多壁碳纳米管修饰碳糊电极,提出了一种灵敏的溶出伏安法测定痕量铜的新方法.在极谱分析仪上采用二阶导数线性扫描伏安法进行分析,在0.1 moL/L的HAc-NaAc缓冲溶液(pH 4.1)中,Cu与修饰电极表面的茜素红S(ARS)形成Cu(Ⅱ)-ARS络合物而富集于电极表面,于-400 mV处还原后,再进行阳极化扫描,于64 mV处获得一灵敏的铜的阳极溶出峰,峰电流与Cu(Ⅱ)浓度在2×10-11 mol/L~6×10-7 mol/L范围内呈良好的线性关系,检出限(S/N=3) 为8.0×10-12 mol/L(富集时间240 s).方法应用于人发中铜含量的测定,回收率为98%~102%. 相似文献
19.
Legeai S Soropogui K Cretinon M Vittori O Heeren De Oliveira A Barbier F Grenier-Loustalot MF 《Analytical and bioanalytical chemistry》2005,383(5):839-847
Stripping analysis has been widely recognised as a powerful tool in trace metal analysis. Its remarkable sensitivity is attributed
to the combination of a preconcentration step coupled with pulse measurements that generate an extremely high signal-to-background
ratio. Mercury-based electrodes have traditionally been used to achieve high reproducibility and sensitivity in the stripping
technique. Because of the toxicity of mercury, however, new alternative electrode materials are highly desired, particularly
for on-site monitoring. Use of thin films of bismuth deposited on platinum or glassy-carbon substrates has recently been proposed
as a possible alternative to mercury—bismuth is “environmentally friendly”, of low toxicity, and is in widespread pharmaceutical
use. In this paper the preparation of economic bismuth-film microelectrodes by electrodeposition on a copper substrate and
their application to heavy metal analysis are described. Bismuth-film electrodes were prepared by potentiostatic electrodeposition.
Optimum conditions for chemical and electrochemical deposition to obtain an adherent, reproducible, and robust deposit were
determined. The suitability of such microelectrodes for analysis of heavy metals was evaluated by anodic stripping voltammetry
of cadmium. The analytical performance of bismuth-film electrodes for anodic stripping voltammetry of heavy metals was evaluated
for non-deaerated solutions containing Cd2+, Pb2+, and Zn2+ ions. Well-defined peaks with low background current were obtained by use of differential pulse voltammetry. Linear calibration
plots were obtained for Cd2+ in acidified tap water at concentrations ranging from 2×10−8 to 1×10−7 mol L−1 and from 1×10−7 to 1×10−6 mol L−1 with relative standard deviations of 5% (n=15) at the 1×10−7 mol L−1 level. The method was then successfully used to monitor the Cd2+content of plant extracts and validated by polarographic and ICP−MS measurements. These results open the possibility of using
bismuth-coated copper electrodes as an alternative to mercury-based electrodes for analysis of heavy metals. The main problem
remaining, which prevents on-site monitoring of heavy metals, is the need to use slightly acidic media, because formation
of bismuth hydroxide on the film surface above pH 4.3 leads to non-reproducible measurements. Further experiments will be
performed to discover whether electrode conditioning can be used to enable reproducible measurement in on-site monitoring
of cadmium in natural waters. Moreover, further study should be conducted to evaluate the potential of BiFE for analysis of
several pollutants of interest that are usually determined electrochemically by using mercury-based electrodes.
Presented at the 9th FECS Conference on Chemistry and the Environment, Bordeaux , 29 August to 1 September, 2004 相似文献
20.
The possibility of applying antimony-film modified glassy carbon electrode in sequential-injection analysis (SIA) was investigated with the objective of determining Pb(II) and Cd(II) by anodic stripping voltammetry (ASV). The conditions of antimony-film deposition concerning composition of the plating/carrier solutions, concentrations of Sb(III) and hydrochloric acid, effects of different supporting electrolyte salts, and plating potential were optimized. It was found that the antimony-film deposition on glassy carbon substrate in a sample solution consisting of 750 μg L−1 Sb(III), 0.5 mol L−1 HCl at −1.5 V (vs. Ag/AgCl/3 mol L−1 KCl) yielded a modified electrode suitable for the determination of Pb(II) and Cd(II) at the μg L−1 level. The reproducibility of the analytical signals was characterized by a relative standard deviation lower than 2.8%, and the calculated values of detection limits were 1.2 μg L−1 for Pb(II) and 1.4 μg L−1 for Cd(II). The presence of KSCN in the sample solution offers the possibility of detecting ions with more negative oxidation potentials like Zn(II), Mn(II) or Cr(III). The developed SIA-ASV procedure was compared with the commonly used batch method, and its applicability was tested on a spiked tap water sample. 相似文献