首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Qian Cao  Lixi Zeng  Rui Wang  Yujian He 《Talanta》2009,80(2):484-488
A novel and simple electrochemical method for determination of melamine is developed based on oligonucleotides film modified gold electrodes. The electrochemical probe of ferricyanide was used to investigate the interactions between oligonucleotides and melamine. Results of cyclic voltammetries, differential pulse stripping voltammetries, electrochemical impedance spectrometry and atomic force microscope, proved that melamine might interact with oligonucleotides mainly through electrostatic and hydrogen-bonding interactions. The interactions between oligonucleotides and melamine lead to the increase in the peak currents of ferricyanide, which could be used for electrochemical sensing of melamine. The redox peak currents of ferricyanide were linear with the concentration of melamine in the range from 3.9 × 10−8 to 3.3 × 10−6 M with a linear coefficiency of 0.990. The detection limit was 9.6 × 10−9 M. The proposed electrochemical biosensor is rapid, convenient and low-cost for effective sensing of melamine. Particularly, the proposed method was applied successfully to the determination of melamine in milk products, and the recovery was 95%.  相似文献   

2.
Poly(3,4-ethylenedioxythiophene-co-(5-amino-2-naphthalenesulfonic acid)) (PEDOT-PANS) film modified glassy carbon electrode was prepared by electrochemical polymerization technique. The properties of modified electrode was studied. It was found that the electrochemical properties of modified electrode was very much dependent on the experimental conditions, such as monomer oxidation potential and pH. The modified electrode surface was characterized by scanning electron microscopy (SEM). The PEDOT-PANS film modified electrode shows electrocatalytic activity toward oxidation of dopamine (DA) in acetate buffer solution (pH 5.0) and results in a marked enhancement of the current response. The linear sweep voltammetric (LSV) peak heights are linear with DA concentration from 2 × 10−6 to 1 × 10−5 M. The detection limit is 5 × 10−7 M. More over, the interferences of ascorbic acid (AA) and uric acid (UA) were effectively diminished. This work provides a simple and easy approach for selective determination of dopamine in the presence of ascorbic acid and uric acid.  相似文献   

3.
Screen-printed electrodes modified with carbon paste that consisted of graphite powder dispersed in ionic liquids (IL) were used for the electrochemical determination of dopamine, adrenaline and dobutamine in aqueous solutions by means of cyclic voltammetry. The IL plays a dual role in modifying compositions, acting both as a binder and chemical modifier (ion-exchanger); ion-exchange analyte pre-concentration increases analytical signal and improves the sensitivity. Calibration graphs are linear in concentration range 3.9 × 10−6 to 1.0 × 10−4 M (dopamine), 2.9 × 10−7 to 1.0 × 10−4 M (adrenaline) and 1.7 × 10−7 to 1.0 × 10−4 M (dobutamine); detection limits are (1.2 ± 0.1) × 10−6, (1.3 ± 0.1) × 10−7 and (5.3 ± 0.1) × 10−8 M, respectively. Using an additive of Co (III) tetrakis-(tert-butyl)-phthalocyanine leads to the increase of signal and lowering detection limit. Some practical advises concerning both the sensor design and selectivity of catecholamine determination are provided.  相似文献   

4.
The oxidation of selected clinically important neurotransmitter metabolites with acidic potassium permanganate in the presence of polyphosphates evokes chemiluminescence of sufficient intensity to enable the sensitive determination of these species. Limits of detection for 5-hydroxyindole-3-acetic acid (5-HIAA), vanilmandelic acid (VMA; α,4-dihydroxy-3-methoxybenzeneacetic acid), 4-hydroxy-3-methoxyphenylglycol (MHPG), homovanillic acid (HVA, 4-hydroxy-3-methoxyphenylacetic acid) and 3,4-dihydroxyphenylacetic acid (DOPAC) were between 5 × 10−9 and 4 × 10−8 M, using flow-injection analysis methodology. In addition, we demonstrate the rapid determination of homovanillic acid and 5-hydroxyindole-3-acetic acid in human urine - without the need for extraction procedures - using monolithic column chromatography with chemiluminescence detection.  相似文献   

5.
R. Brimecombe 《Talanta》2007,71(3):1298-1303
Amitraz is a formamide acaracide used in the control of ticks and mites in livestock. An electrochemical method for the determination of total amitraz residues and its final breakdown product, 2,4-dimethylaniline, is presented. Cyclic voltammetry at a glassy carbon electrode showed the irreversible oxidation of amitraz and of 2,4-dimethylaniline. A linear current response was obtained with an extrapolated limit of detection of 2 × 10−8 M for amitraz and 1 × 10−8 M for 2,4-dimethylaniline. The biological degradation of amitraz and subsequent formation of 2,4-dimethylaniline was readily monitored in spent cattle dip. Amitraz and 2,4-dimethylaniline was also monitored in milk and honey samples.  相似文献   

6.
Imipenem shows a fast chemical conversion to a more stable imin form (identical to that of biochemical dehydropeptidase degradation) in aqueous solutions and stabilizing agents used avoid its electrochemical study and determination.The aim of this work is the proposal of urea as stabilizing agent which allows the electrochemical study of imipenem and the proposal of electrochemical methods for the determination of imipenem and its primary metabolite (M1) in human urine samples. Electrochemical studies were realized in phosphate buffer solutions over pH range 1.5-8.0 using differential-pulse polarography, DC-tast polarography, cyclic voltammetry and adsorptive stripping voltammetry. In acidic media, a non-reversible diffusion-controlled reduction involving a two steps mechanism which involves one electron and one proton in the first step and two electrons and two protons in the second step occurs and the mechanism for the reduction was suggested.A differential-pulse polarographic method for the determination of imipenem in the concentration range 3.2 × 10−6 to 2 × 10−5 M (0.95-3.4 mg/L) and its primary metabolite in the concentration range 1.4 × 10−6 to 10−4 M (0.43-26.1 mg/L) with detection limits of 9.6 × 10−7 M (0.28 μg/L imipenem) and 4.3 × 10−7 M (0.14 μg/L M1) was proposed. Also, a method based on controlled adsorptive pre-concentration of imipenem on the hanging mercury drop electrode followed by voltammetric measure, allows imipenem determination in the concentration range 1.8 × 10−8 to 1.2 × 10−6 M (5.42-347 μg/L) with a detection limit of 5.4 × 10−9 M (1.63 μg/L). The proposed methods have been used for the direct determination of the analytes in a pharmaceutical formulation and human urine.  相似文献   

7.
An indirect voltammetric method is described for determination of cyanide ions and hydrogen cyanide, using the effect of cyanide on cathodic adsorptive stripping peak height of Cu-adenine. The method is based on competitive Cu complex formation reaction between adenine at the electrode surface and CN ions in solution. Under the optimum experimental conditions (pH=6.42 Britton-Robinson buffer, 1×10−4 M copper and 8×10−7 M adenine), the linear decrease of the peak current of Cu-adenine was observed, when the cyanide concentration was increased from 5×10−8 to 8×10−7 M. The detection limit was obtained as 1×10−8 M for 60 s accumulation time. The relative standard deviations for six measurements were 4 and 2% for the cyanide concentrations of 5×10−8 and 2×10−7 M, respectively. The method was applied to the determination of cyanide in various industrial waste waters such as electroplating waste water and also for determination of hydrogen cyanide in air samples.  相似文献   

8.
The Sonogel-Carbon electrode is a special class of sol-gel electrode that exhibits favourable mechanic and electric properties to be used as electrochemical sensor. In this study, Sonogel-Carbon modified with l-Cysteine was used to prepare a novel electrochemical sensor. The objective of this novel electrode modification was to seek new electrochemical performances for detection of epinephrine in the presence of uric acid. The response of catalytic current with epinephrine concentration shows a linear relation in the range from 1 × 10−7 to 5 × 10−4 M with a correlation coefficient of 0.998, and a detection limit of 8.7 × 10−8 M. The modified electrode had also been applied to the determination of epinephrine and uric acid in biological samples with satisfactory results. A surface characterisation of this modified electrode was carried out helped by scanning electron microscopy (SEM) and X-Ray energy dispersive spectroscopy (EDS).  相似文献   

9.
Preparation and application of gold 2-mercaptosuccinic acid self-assembled monolayer (Au-MSA SAM) electrode for determination of iron(III) in the presence of iron(II) is described by cyclic voltammetry, electrochemical impedance spectroscopy, and Osteryoung square wave voltammetry. The square wave voltammograms showed a sharp peak around positive potentials +0.250 V that was used for construction of the calibration curve. Parameters influencing the method were optimized. A linear range calibration curve from 1.0 × 10−10 to 6.0 × 10−9 M iron(III) with a detection limit of 3.0 × 10−11 M and relative standard deviation (R.S.D.) of 6.5% for n = 8 at 1.0 × 10−9 M iron(III) was observed in the best conditions. Possible interferences from the coexisting ions were also investigated. The results demonstrated that sensor could be used for determination of iron(III) in the presence of various ions. The validity of the method and applicability of the sensor were successfully tested by determining of iron(III) in natural waters (tap and mineral waters) and in a pharmaceutical sample (Venofer® ampoule) without interference from sample matrix. The experimental data are presented and discussed from which the new sensor is characterized.  相似文献   

10.
Qu F  Shi A  Yang M  Jiang J  Shen G  Yu R 《Analytica chimica acta》2007,605(1):28-33
Prussian blue nanowire array (PBNWA) was prepared via electrochemical deposition with polycarbonate membrane template for effective modification of glassy carbon electrode. The PBNWA electrode thus obtained was demonstrated to have high-catalytic activity for the electrochemical reduction of hydrogen peroxide in neutral media. This enabled the PBNWA electrode to show rapid response to H2O2 at a low potential of −0.1 V over a wide range of concentrations from 1 × 10−7 M to 5 × 10−2 M with a high sensitivity of 183 μA mM−1 cm−2. Such a low-working potential also substantially improved the selectivity of the PBNWA electrode against most electroactive species such as ascorbic acid and uric acid in physiological media. A detection limit of 5 × 10−8 M was obtained using the PBNWA electrode for H2O2, which compared favorably with most electroanalysis procedures for H2O2. A biosensor toward glucose was then constructed with the PBNWA electrode as the basic electrode by crosslinking glucose oxidase (GOx). The glucose biosensor allowed rapid, selective and sensitive determination of glucose at −0.1 V. The amperometric response exhibited a linear correlation to glucose concentration through an expanded range from 2 × 10−6 M to 1 × 10−2 M, and the response time and detection limit were determined to be 3 s and 1 μM, respectively.  相似文献   

11.
A chemically modified carbon paste electrode with 3,4-tetra pyridinoporphirazinatocobalt(II) (Co(3,4 tppa) was applied to the determination of free cyanide ion. The electrode has a linear range between 1.5 × 10−5 M and 1.0 × 10−2 M with a Nernstian slope of 60 ± 1.5 mV/decade and its detection limit is 9 × 10−6 M. The response time of electrode is 5 min. The proposed electrode was applied successfully for the determination of cyanide in commercially available spring water. Some anions, such as SCN, I, Cl, Br and oxalate that are usually serious interfering species for most of cyanide selective electrodes, did not have any interfering effect for this proposed electrode.  相似文献   

12.
The influence of the boron-doping levels in boron-doped diamond film electrodes on the electrochemical response of nitrofurantoin (NFT) and the development of an electroanalytical procedure for NFT determination were investigated. The investigations were carried out using the techniques of cyclic voltammetry and square wave voltammetry on diamond film electrodes with different boron-doping levels (i.e., 5000, 10,000 and 20,000 mg L−1). The level of boron-doping in the diamond film electrodes influenced the electrochemical reduction of NFT. The appropriate cyclic voltammetric response of NFT was obtained with Britton-Robinson buffer at pH 4 and for diamond films doped with 10,000 and 20,000 mg L−1 of boron. These two films were selected for the development of the electroanalytical procedure. The use of square wave voltammetry with the optimized parameters demonstrated a good linear relationship between the peak current and the NFT concentration for a wide range of concentration. The lower limit of detection for the electrodes doped with 10,000 and 20,000 mg L−1 of boron were 2.69 × 10−8 mol L−1 (6.40 μg L−1) and 8.15 × 10−9 mol L−1 (1.94 μg L−1), respectively, while the lower limits of quantification were 8.96 × 10−8 mol L−1 (21.33 μg L−1) and 2.72 × 10−8 mol L−1 (6.47 μg L−1), respectively. The applicability of the proposed procedure was tested using a commercial pharmaceutical formulation of NFT, and the results were compared with the procedure recommended by the British Pharmacopeia. The proposed procedure was sensitive, accurate and precise for analysis of NFT and did not require complex preparations or renovations of the electrode surface. This presents the advantage of eliminating mercury waste and minimizing the adsorptive problems related to the use of other electrodic solid surfaces.  相似文献   

13.
Yan Wang  Zhen-zhen Chen 《Talanta》2010,82(2):534-621
This report described the direct voltammetric detection of peroxynitrite (ONOO) at a novel cyanocobalamin modified glassy carbon electrode prepared by electropolymeriation method. The electrochemical behaviors of peroxynitrite at the modified electrode were studied by cyclic voltammetry. The results showed that this new electrochemical sensor exhibited an excellent electrocatalytic activity to oxidation of peroxynitrite. The mechanism of catalysis was discussed. Based on electrocatalytic oxidation of peroxynitrite at the poly(cyanocobalamin) modified electrode, peroxynitrite was sensitively detected by differential pulse voltammetry. Under optimum conditions, the anodic peak current was linear to concentration of peroxynitrite in the range of 2.0 × 10−6 to 3.0 × 10−4 mol L−1 with a detection limit of 1.0 × 10−7 mol L−1 (S/N of 3). The proposed method has been applied to determination of peroxynitrite in human serum with satisfactory results. This poly(cyanocobalamin) modified electrode showed high selectivity and sensitivity to peroxynitrite determination, which could be used in quantitative detection of peroxynitrite in vivo and in vitro.  相似文献   

14.
A competitive enzyme-linked immunosorbent assay for dopamine (DA) has been optimized and characterized. DA is sensitive to oxygen and light according to a function of the pH on the DA oxidation process. The phenolic groups in DA are readily oxidisable to a quinoid form and thus, free DA deteriorates in alkaline media. Thus, effect of factors such as pH, enzyme-label with substrate, ionic strength and reaction time was considered on performance of ELISA. Assay was performed with 5 μg mL−1 of BSA-DA and 1/7500 dilution of anti-DA antibody. A dose-response curve was constructed, and a limit of detection and a dynamic range for DA were accomplished to 1.0 × 10−9 M (0.19 μg L−1) and five orders (3.2 × 10−8 M to 3.2 × 10−3 M) of magnitude, respectively. The correlation diagram of the absorbance obtained both in buffer and in serum has shown good agreement with correlation coefficient (R2 = 0.9947): Abs. (in serum) = 0.6128 × Abs. (in buffer) + 0.2926. The cross-reactivity was examined with the structurally similar compounds. And the results demonstrated that epinephrine and 3-methoxytyramine showed cross-reactivity (18.9% each), whereas 3,4-dihydroxyphenylacetic acid and homovanillic acid showed low cross-reactivity (<1%). And percent recoveries of DA in serum were quite satisfactory. This provides usefulness of the present assay to monitor DA in serum.  相似文献   

15.
The cyclic voltammogram of the anti-coagulant drug warfarin sodium at the hanging mercury drop electrode exhibited a well-defined single two-electron irreversible peak over the pH range 4-7, which may be attributed to the reduction of the CO double bond of the drug molecule. Based on the interfacial adsorptive character of the drug onto the mercury electrode surface, a square-wave cathodic stripping procedure was optimized for its trace determination. The calibration plot was linear over the concentration range of 5×10−9 to 4×10−7 M warfarin sodium in Britton-Robinson (B-R) buffer of pH 5, with limits of detection and quantitation of 6.5×10−10 and 2.1×10−9 M warfarin sodium, respectively. The proposed procedure was successfully applied for assay of warfarin sodium in its pharmaceutical formulation “hemofarin tablets”, human serum and urine without the necessity for sample pretreatment or time-consuming extraction or evaporation steps, prior to assay of the drug. Limits of detection of 1.1×10−9 and 1.3×10−8 M warfarin sodium were achieved, while limits of quanitation of 3.7×10−9 and 4.3×10−8 M warfarin sodium were estimated in human serum and urine, respectively. The pharmacokinetic profiles of the drug were studied and the estimated pharmacokinetic parameters were favorably compared with those reported in literature.  相似文献   

16.
Liu AL  Zhang SB  Chen W  Huang LY  Lin XH  Xia XH 《Talanta》2008,77(1):314-318
The electrochemical behavior of isorhamnetin (ISO) at a glassy carbon electrode was studied in a phosphate buffer solution (PBS) of pH 4.0 by cyclic voltammetry (CV) and differential pulse voltammetric method (DPV). A well-defined redox wave of ISO involving one electrons and one proton appeared. The electrode reaction is a reactant weak adsorption-controlled process with a charge transfer coefficient (α) of 0.586. Based on the understanding of the electrochemical process of ISO at the glassy carbon electrode, analysis of ISO can be realized. Under optimal conditions, the oxidation peak current showed linear dependence on the concentration of ISO in the range of 1.0 × 10−8 to 4.0 × 10−7 M and 1.0 × 10−6 to 1.0 × 10−5 M. The detection limit is 5.0 × 10−9 M. This method has been successfully applied to the detection of ISO in tablets.  相似文献   

17.
The electrochemical properties of valacyclovir, an antiviral drug, were investigated in pH range 1.8-12.0 by cyclic, differential pulse and square-wave voltammetry. The drug was irreversibly oxidized at a glassy carbon electrode in one or two oxidation steps, which are pH-dependent. For analytical purposes, a very resolved diffusion controlled voltammetric peak was obtained in Britton-Robinson buffer at pH 10.0 using differential pulse and square-wave modes. Limits of detection were 1.04 × 10−7 and 4.60 × 10−8 M for differential pulse and square-wave voltammetry, respectively. The applicability to direct assays of tablets, spiked human serum and simulated gastric fluid, was described.  相似文献   

18.
Shervedani RK  Babadi MK 《Talanta》2006,69(3):741-746
Fabrication and application of a voltammetric sensor based on gold 2-mercaptobenzothiazole self-assembled monolayer (Au-MBT SAM) for determination of silver ion is described. Preliminary experiments were performed to characterize the monolayer. The surface pKa determined for the MBT monolayer is 7.0. This value was obtained by impedimetric titration of the monolayer in the presence of Fe(CN)63−/4− as a redox probe. The extent of surface coverage was evaluated as 1.52 × 10−9 mol cm−2 based on charged consumed for reductive desorption of the monolayer in the 0.50 M NaOH solution. Then the sensor was used for determination of Ag(I) by square wave voltammetry. The parameters affecting the sensor response, such as pH and supporting electrolyte, were optimized. A dynamic calibration curve with two linear parts was obtained in the concentration ranges of 5 × 10−8-8 × 10−7 and 1 × 10−6-1 × 10−5 M of Ag(I). The detection limit adopted from cathodic striping square wave voltammetry was as 1 × 10−8 M for n = 7. Furthermore, the effect of potential interfering ions on the determination of Ag(I) was studied, and an appropriate method was used for the elimination of this effect.  相似文献   

19.
This paper describes a potentiometric method for determination of l-histidine (l-his) in aqueous media, using a carbon paste electrode modified with tetra-3,4-pyridinoporphirazinatocopper(II) (Cu (3,4tppa)). The electrode exhibits linear response to the logarithm of the concentration of l-histidine from 2.4 × 10−5 to 1.0 × 10−2 M, with a response slope of −49.5 ± 1 mV and response time of about 1.5 min. The detection limit according to IUPAC recommendation was 2.0 × 10−5 M. The proposed electrode shows a good selectivity for l-his over a wide variety of anions. This chemically modified carbon paste electrode was successfully used for the determination of l-his in a synthetic serum and RANDOX control serum solutions.  相似文献   

20.
Saumya V  Prathish KP  Rao TP 《Talanta》2011,85(2):1056-1062
Organic-inorganic hybrids are promising functional materials as they combine the special characteristics of both organic (polymer) and inorganic phases. Among different existing approaches for the preparation of such polymer-inorganic hybrid coatings, in situ electrochemical methods are very advantageous because of their high sensitivity and simplicity. In the present study, voltammetric sensors for tyrosine are designed and developed via various modifications on glassy carbon electrode such as polypyrrole coated GCE, molecularly imprinted polypyrrole coated GCE (MIPPy) and in situ copper oxide modified MIPPy coated GCE. Of these, in situ copper oxide modified MIPPy coated GCE sensor responds to tyrosine concentrations in the range 1 × 10−8 to 1 × 10−6 and 2 × 10−6 to 8 × 10−6 M with a very low detection limit of 4.0 × 10−9 M and by far the most sensitive one. Detailed linear sweep voltammetric and chronoamperometric experiments were undertaken to investigate the electrocatalytic behavior of tyrosine. The electron transfer coefficient, diffusion coefficient and charge transfer rate constants involved in the sensing process using in situ copper oxide modified MIPPy film coated GCE are 0.47, 1.88 × 10−6 cm2 s−1, 4.7 × 106 L mol−1 s−1, respectively. Furthermore, the designed sensor is highly selective and has been applied successfully for the analysis of synthetic and real samples of human urine.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号