首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 859 毫秒
1.
Gas chromatography coupled to ion trap tandem mass spectrometry (GC–ITMS-MS) is proposed for the analysis of methoxylated polybrominated diphenyl ethers (MeO-PBDEs) in fish and shellfish. MS–MS operating parameters related to the isolation and fragmentation of the precursor ions were optimized to achieve maximum sensitivity and selectivity. This new method allows the determination of both MeO-PBDEs and PBDEs in a single run. Low limits of detection (0.4–2.5 pg injected) and high precision (RSD < 13%) were achieved. A sample treatment based on a selective pressurized liquid extraction (PLE) using Florisil as fat retainer was applied for the analysis of these compounds in fish samples. Method limits of quantification ranged from 0.11 to 0.95 ng g−1 lipid weight for MeO-PBDEs and between 0.18 and 0.50 ng g−1 lipid weight for PBDEs. In addition, good repeatability of the whole method was achieved (RSD < 15%). The suitability of the method was evaluated by analyzing a certified reference material (SRM 1945, whale blubber) with satisfactory results. The developed method was applied to the simultaneous analysis of MeO-PBDEs and PBDEs in fish and shellfish samples from the Mediterranean Sea.  相似文献   

2.
Abstract

A method for the determination of toxaphene in whole blood using gas chromatography (GC)-electron capture negative ion ECNI/MS and pure polychlorobornane congerners has been evaluated. Blood samples were extracted with hexane/acetone (9:1), extracts defatted with sulfuric acid, analytes fractionated on Carbopack-C/ Florisil (or silica gel) SPE columns then concentrated to final volumes for GC-ECNI/MS analysis. For confirmation, interference from PCBs and other organochlorine pesticides were removed by nitration.  相似文献   

3.
An effective multi‐residue pretreatment technique, solid‐phase extraction (SPE) combined with dispersive liquid–liquid microextraction (DLLME), was proposed for the trace analysis of 14 polychlorinated biphenyls (PCBs) and polybrominated diphenyl ethers (PBDEs) in milk samples using gas chromatography–mass spectrometry (GC‐MS). Interesting analytes in milk samples were extracted with hexane after protein precipitation. The hexane extracts were loaded on an LC‐Florisil column to isolate analytes from the milk matrix. The elutes were dried and dissolved in acetone, which was used as the disperser solvent in subsequent DLLME procedures. The effects of several important parameters on the extraction efficiency were evaluated. Under the optimized conditions, a linear relationship was obtained in the range of 0.02–10.00 μg/L (PCBs) and 0.5–100.00 μg/L (PBDEs). The LOD (S/N=3) and relative standard deviations (RSDs, n=5) for all analytes were 0.01–0.4 μg/L and 0.6–8.5%, respectively. The recoveries of the standards added to raw bovine milk samples were 74.0–131.8%, and the repeatabilities of the analysis results were 1.12–17.41%. This method has been successfully applied to estimating PCBs and PBDEs in milk samples.  相似文献   

4.
Polybrominated diphenyl ethers (PBDEs) are a class of flame retardants used globally in many consumer products and industrial applications. Traditionally, gas chromatography–high resolution mass spectrometry (GC–HR-MS) is the method of choice for analysis of PBDEs in environmental samples because it offers high sensitivity and selectivity, resulting in less interferences. However, the specificity offered by gas chromatography-triple quadrupole tandem mass spectrometry (GC–QQQ-MS/MS), operated in selected reaction monitoring mode, provides a more affordable alternative to GC–HR-MS for the analysis of PBDEs in complex environmental samples. In this study, an analytical method was developed for the analysis of 41 PBDE congeners in fish using GC–QQQ-MS/MS. Results from the analysis of three fish species [lake trout (Salvelinus namaycush), yellow perch (Perca flavescens), and round goby (Neogobius melanostomus)] using GC–QQQ-MS/MS were compared with those obtained by GC–HR-MS. These species were selected because they represent varying levels of lipid-rich matrix and contaminant loads. Instrumental limits of detection for the GC–QQQ-MS/MS ranged from 0.04 pg to 41 pg, whereas those for the GC–HR-MS ranged from 5 pg to 85 pg. The PBDE values obtained from these two methods were highly correlated, R2 values >0.7, for all three fish species, supporting the suitability of GC–QQQ-MS/MS for analysis of PBDEs in fish with varying fat content.  相似文献   

5.
S. Losada  M.T. Galceran 《Talanta》2009,80(2):839-91
A fast and simple method for the analysis of polybrominated diphenyl ethers (PBDEs) in fish samples was developed using a one-step extraction and clean-up by means of pressurized liquid extraction (PLE) combined with gas chromatography-ion trap tandem mass spectrometry (GC-ITMS-MS). The selective PLE method provided to obtain ready-to-analyse extracts without any additional clean-up step, using a sorbent as fat retainer inside the PLE cell. Several PLE operating conditions, such as solvent type, extraction temperature and time, number of cycles and type of fat retainer, were studied. Using Florisil as fat retainer, maximum recoveries of PBDEs (83-108%) with minimum presence of matrix-interfering compounds were obtained using a mixture of n-hexane:dichloromethane 90:10 (v/v) as solvent, an extraction temperature of 100 °C and a static extraction time of 5 min in combination with three static cycles. Quality parameters of the method were established using standards and fish samples. Limits of detection and quantification ranged from 10 to 34 pg g−1 wet weight and between 34 and 68 pg g−1 wet weight, respectively. In addition, good linearity (between 1 and 500 ng ml−1) and high precision (RSD % < 15%) were achieved. The method was validated using the standard reference material SRM-1945 (whale blubber) and was then applied to the analysis of PBDEs in fish samples.  相似文献   

6.
The determination of target analytes such as nonyl- and octylphenols and 17β-estradiol in fish homogenate require of solid–liquid extraction step. In this work microwave-assisted extraction (MAE) and focused-ultrasound liquid extraction (FUSLE) were studied as two different alternatives for extraction of the target compounds in zebrafish (Danio rerio) homogenate. In this work solid phase extraction (SPE) using 5-g and 10-g Florisil cartridges and gel permeation chromatography (GPC) were studied for the clean-up of the MAE and FUSLE extracts due to the non-selective extraction step. Although good recoveries were obtained both for SPE (106% and 126% range) and GPC (79% and 100% range) clean-up procedures, cleaner chromatograms were obtained after SPE and finally 5-g Florisil cartridges were tested since no improvement was observed when 10-g Florisil cartridges were used. Under optimized clean-up conditions, MAE and FUSLE provided comparable results for 4nOP and NP, while more accurate results were obtained for 4tOP and E2 after FUSLE. Finally, the method was applied to the determination of alkylphenols and 17β-estradiol in zebrafish homogenate that had been exposed to known concentrations of the target analytes. In the case of alkylphenols two different isomers of nonyl- and octylphenol (4-(3′,6′-dimethyl-3′-hepthyl)phenol, 363-NP, and 4-(3′-methyl-3′-hepthyl)phenol, 33-OP) were studied.  相似文献   

7.
建立了凝胶渗透色谱(GPC)结合气相色谱-负化学源质谱(GC-NCI/MS)检测鱼肉及鱼油中8种多溴联苯醚(PBDEs)同系物及2种得克隆阻燃剂(DP)的分析方法。试样中加入内标物BDE-77和13C12-BDE-209后进行索氏提取,提取液经自动GPC系统除脂,多层硅胶层析柱净化后,在15 m长的毛细管气相色谱柱上分离,NCI/MS以选择离子监测方式检测目标化合物。以鱼肉样品为基质,当PBDEs的加标水平为0.2 ng/g和2 ng/g、BDE-209和DP的加标水平相应提高10倍时,其平均加标回收率为71.1%~121.4%,相对标准偏差为2.96%~13.31%(n=5);以信噪比(S/N)为3计算方法的检出限(LOD)为2.2~39.8 ng/kg。用该方法检测市售鱼肉及鱼油样品,其中多溴联苯醚总含量为2.18~15.93 ng/g,以BDE-209、BDE-47为主,两种DP均未检出。该方法准确、灵敏度高,能够满足富含脂质的动物性样品中痕量DP和PBDEs残留的分析要求。  相似文献   

8.
Shi Z  Wang Y  Feng J  Huang P  Wu Y 《色谱》2011,29(6):543-548
建立了凝胶渗透色谱(GPC)结合气相色谱-负化学源质谱(GC-NCI/MS)检测鱼肉及鱼油中8种多溴联苯醚(PBDEs)同系物及2种得克隆阻燃剂(DP)的分析方法。试样中加入内标物BDE-77和13C12-BDE-209后进行索氏提取,提取液经自动GPC系统除脂,多层硅胶层析柱净化后,在15 m长的毛细管气相色谱柱上分离,NCI/MS以选择离子监测方式检测目标化合物。以鱼肉样品为基质,当PBDEs的加标水平为0.2 ng/g和2 ng/g、BDE-209和DP的加标水平相应提高10倍时,其平均加标回收率为71.1%~121.4%,相对标准偏差为2.96%~13.31%(n=5);以信噪比(S/N)为3计算方法的检出限(LOD)为2.2~39.8 ng/kg。用该方法检测市售鱼肉及鱼油样品,其中多溴联苯醚总含量为2.18~15.93 ng/g,以BDE-209、BDE-47为主,两种DP均未检出。该方法准确、灵敏度高,能够满足富含脂质的动物性样品中痕量DP和PBDEs残留的分析要求。  相似文献   

9.
This paper describes the development and validation of an analytical methodology to determine 28 polybrominated diphenyl ethers (PBDEs) in European eel (Anguilla anguilla) tissues using matrix solid-phase dispersion (MSPD) and gas chromatography coupled to triple quadrupole mass spectrometry (GC-QQQ-MS/MS). A total of 28 PBDEs were targeted, including tri- to deca-brominated congeners.The robustness and effectiveness of the proposed sample preparation procedure was demonstrated in lipid-rich eel tissues. The use of batch MSPD with activated silica gel and H2SO4-impregnated silica gel, followed by H2SO4 digestion and multilayer cartridge clean-up allowed for complete lipid removal and eliminated matrix effects during GC-QQQ-MS/MS analysis. The average PBDE recoveries from eel muscle samples spiked with PBDEs at two levels were in the range 56.2-119.0%. Precision was satisfactory since relative standard deviations were lower than 19.6%, regardless of spike level, and method quantification limits ranged between 1 and 170 pg g−1 (wet weight).The method demonstrated its successful application for the analysis of eel samples from two coastal lagoons located on the western French Mediterranean coast. All samples tested positive, but for tri- to hexa-brominated congeners only and total PBDE levels observed in this study were in the range 0.08-1.80 ng g−1 wet weight.  相似文献   

10.
建立了气相色谱-负离子化学电离质谱法(GC-NCI/MS)同时分析深海鱼油食品中5种多溴联苯醚残留的分析方法。深海鱼油食品用正己烷超声提取、中性与酸性硅胶色谱柱净化和正己烷洗脱后,以PCB103为内标物,采用GC-NCI/MS的选择离子监测方式(SIM)分析;同时探讨了5种多溴联苯醚的NCI/MS特征离子的断裂机理。当空白深海鱼油食品的加标浓度为20.0和100.0 μg/kg时,加标回收率为88.6%~111.3%,相对标准偏差为3.8%~13.5%,方法的检测限为0.77~1.34 μg/kg,线性范围为1.0~500.0 μg/kg,相关系数均大于0.9992。此方法已成功地应用于深海鱼油食品中5种痕量多溴联苯醚残留的同时分析。  相似文献   

11.
Liu H  Zhang Q  Song M  Jiang G  Cai Z 《Talanta》2006,70(1):20-25
A comprehensive method was developed for quantitative analysis of polybrominated diphenyl ethers (PBDEs), polychlorinated biphenyls (PCBs) and polychlorinated dibenzo-p-dioxins and dibenzo-furans (PCDD/Fs) in one single extract of environmental samples. The sample preparation procedure included two fractionation steps using silver nitrate silica chromatography to separate PBDEs from PCBs and PCDD/Fs and florisil column to separate PCBs from PCDD/Fs. Acidic silica, acidic alumina and gel permeation chromatography (GPC, for PCBs) or activated carbon column (for PCDD/Fs) were used for further clean-up. The sample extracts were analyzed by using high-resolution gas chromatography/high-resolution mass spectrometry. The entire method was validated from the analysis of mixed standards of PBDEs, PCBs and PCDD/Fs (n = 3); the analysis of certified reference biota (WMF-01). The method was applied for the analysis of 10 sediment samples collected from Haihe River and Dagu Drainage River in Tianjin City. No significant PBDEs pollution was found in the areas.  相似文献   

12.
Zhang Z  Rhind SM 《Talanta》2011,84(2):487-493
We describe a solid-phase extraction (SPE) method, followed by gas chromatography-mass spectrometry (GC-MS), for the simultaneous determination of polybrominated diphenyl ethers (PBDEs) and polychlorinated biphenyls (PCBs) in sheep serum samples. The denaturation of serum proteins by formic acid, water-1-propanol and water-2-propanol were compared and optimized. Seven different solid-phase sorbents were tested and it was found that Strata-X cartridge (200 mg, 6 mL) gave the best recoveries (92-106%, SD < 6%, n = 3) for all the target analytes. The different extraction solvents (iso-hexane and dichloromethane), either alone or in combination, were used to extract these persistent organic compounds from spiked serum samples by SPE. Removal of co-extracted biogenic materials was achieved using adsorption chromatography with acid modified silica and activated silica. Iso-hexane was found to be the most appropriate solvent for clean-up providing good recoveries and clear chromatographic separation; its use is preferable to that of DCM because it is less environmentally toxic. The limits of detection (LOD) of the proposed method were 47-105 pg g−1 and 16-24 pg g−1 for the different PBDEs and PCBs studied, respectively. The developed method was linear over the range from 0.05 to 30 ng g−1, for all PBDEs except PBDE 183 (0.10-30 ng g−1), and from 0.02 to 30 ng g−1 for all tested PCB congeners. The established method was successfully applied to sheep serum samples from Scotland, UK, for the determination of the target PBDEs and PCBs.  相似文献   

13.
A rapid analytical method has been developed for the determination of polybrominated diphenyl ethers (PBDEs) in human hair. PBDEs were determined by gas chromatography with electron ionization mass spectrometric detection in the selected ion monitoring mode (GC-MS-SIM). A 200 mg amount of hair samples was overnight digested in 3N HCl and then PBDEs extracted with n-hexane. After clean up of extracts in a Florisil column, PBDEs were analyzed by GC-MS. The method has been validated by spiking human hair at five concentration levels, in the range from 5 to 25 ng/g for most compounds, and PBDEs were quantified using labelled compounds as internal standards. Recoveries of PBDEs were higher than 90%, repeatability was equal or lower than 12.5%, and reproducibility lower than 14%, expressed as relative standard deviation (RSD). Limits of detection (LOD) were in the range 0.08-0.9 ng/g and limits of quantification (LOQ) were between 0.27 and 3.0 ng/g. This method was applied to the determination of PBDEs in hair samples from 16 individuals and 5 PBDE congeners were detected in most of the samples. BDE-209 was the dominant compound found, followed by BDE-47, BDE-99, BDE-100, and BDE-190. BDE-209 was found in 12 out of 16 hair samples, and the total levels of PBDEs ranged from 1.4 to 19.9 ng/g.  相似文献   

14.
Dongli Wang  Zongwei Cai 《Talanta》2007,72(2):668-674
A column chromatography procedure was developed for the clean-up of solvent-extracted sediment samples for the fractionation of polybrominated diphenyl ethers (PBDEs) and polybrominated dibenzo-p-dioxins and dibenzofurans (PBDD/Fs). The procedure included multiple column chromatography steps for clean-up for the separation of PBDEs from PBDD/Fs. The separation of the two chemical groups overcame the mutual interfering problem during the GC-ion trap MS analysis. The method was validated with the analysis of quality control samples. The method accuracy represented with relative error was less than 16% for all targeted PBDEs and PBDD/Fs congeners. Recoveries of the 13C-labeled standards ranged from 64% to 117% with relative standard deviation from 7.3% to 15%. Results from the analysis of environmental sediment samples collected in the vicinity of a recycling site for electronic wastes showed high levels of PBDEs (1.5-12 ng/g, dry weight), trace levels of PBDFs (0.025-0.92 ng/g, dry weight) and non-detectable PBDDs.  相似文献   

15.
Petroleum hydrocarbons (oil) are common environmental contaminants. For risk assessment purposes, their concentrations in environmental matrixes, such as biota and soils/sediments are frequently determined by solvent extraction and subsequent analysis with gas chromatography (GC) equipped with flame ionization detection (FID) or mass spectrometry (MS). Because the total GC detector response is labeled as total petroleum hydrocarbon (TPH) concentration and matrix compounds (lipids, organic matter) will contribute to this response, proper extract clean-up is crucial. Still, the choice for a specific clean-up material during open column chromatography often seems arbitrary, since no comparative study on clean-up agents for TPH analysis is available. Here, such a study is described and it is demonstrated that none of the commonly used agents fulfills the requirements of complete matrix compound removal and TPH recovery. A novel column filled with (top-down) 1 g of 33% (w/w) 1 M NaOH-impregnated and 2.2 g of 7% (w/w) H2SO4-impregnated silica gel is recommended for cleaning-up biota extracts, as it fully removes extracted lipids and yields acceptable TPH recoveries of around 90%, based on a certified oil reference standard. For sediment extracts, most columns tested resulted in a negligibly low contribution of matrix compounds to the overall detector response, but 5% deactivated Florisil or 10% deactivated aluminum oxide are preferable, because these materials yield the highest (∼95%) TPH recoveries.  相似文献   

16.
The potential of gas chromatography coupled to tandem mass spectrometry (GC/MS/MS) with a triple quadrupole analyzer (QqQ) has been investigated for the quantification and reliable identification of sixteen polycyclic aromatic hydrocarbons (PAHs) from the EPA priority list in animal and vegetable samples from aquaculture activities, whose fat content ranged from 5 to 100%. Matrices analyzed included fish fillet, fish feed, fish oil and linseed oil. Combining optimized saponification and solid‐phase extraction led to high efficiency in the elimination of interfering compounds, mainly fat, from the extracts. The developed procedure minimized the presence of these interfering compounds in the extracts and provided satisfactory recoveries of PAHs. The excellent sensitivity and selectivity of GC/(QqQ)MS/MS in selected reaction monitoring (SRM) allowed to reach limits of detection at pg/g levels. Two SRM transitions were acquired for each analyte to ensure reliable identification of compounds detected in samples. Confirmation of positive findings was performed by GC coupled to high‐resolution time‐of‐flight mass spectrometry (GC/TOFMS). The accurate mass information provided by GC/TOFMS in full acquisition mode together with its high mass resolution makes it a powerful analytical tool for the unequivocal confirmation of PAHs in the matrices tested. The method developed was applied to the analysis of real‐world samples of each matrix studied with the result of detecting and confirming the majority of analytes at the µg/kg level by both QqQ and TOF mass spectrometers. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

17.
A. Hibberd 《Talanta》2009,77(4):1315-8272
This paper describes an improved method for the extraction and analysis of seven endocrine disrupting chemicals with wide-ranging polarities from water and sediments using gas chromatography-tandem mass spectrometry (GC-MS/MS). The analytes were 4-tert-octylphenol, 4-nonylphenol, bisphenol A, estrone, 17β-estradiol, 17α-ethynylestradiol and 16α-hydroxyestrone. The optimised GC-MS/MS method produces increased selectivity and sensitivity compared to GC-MS, with limit of detection ranging from 0.01 to 0.49 ng L−1 in water and from 0.05 to 0.14 ng g−1 in sediment. Extraction from aqueous samples was performed by solid-phase extraction (SPE) and from sediment samples by microwave-assisted extraction (MAE). The improved method for the clean-up of sediment extracts carried out by SPE enhanced EDC recovery (86-102%) while reducing matrix interference and sample drying time. Derivatisation of final sample extracts was achieved using N,O-bis(trimethylsilyl)trifluoroacetamide and pyridine, and their stability was enhanced by reconstituting the derivatised extracts with hexane. The method was validated by spiking experiments which showed good recovery and reproducibility. The method was applied to samples taken from the Medway estuary in Kent, UK, where non-conservative behaviour of EDCs was demonstrated.  相似文献   

18.
The purpose of this study is to establish an easy and accurate method for the determination of bisphenol A (BPA) in the human serum. The samples were applied to the C18 solid phase extraction (SPE) column for clean up of samples. The BPA is conjugated with tetrabutylammonium hydrogen sulfate as the counter ion in alkali solution. The ion paired BPA is moves from the aqueous phase to the organic phase as an ion paired extraction. BPA extracted from human serum were derivatized with pentafluorobenzyl bromide (PFBBr). The derivative was analyzed by gas chromatography (GC)/mass spectrometry (MS) using negative chemical ionization (NCI). The instrumental detection limit of BPA was 5 pg/ml (10 fg). The instrumental response between 0.01 and 100 pg/ml of BPA standards was linear (r2=0.998). The recovery of BPA spiked into human serum was 101.0±4.63 (1 pg/ml) and 100.9±3.75 (10 pg/ml), respectively. The concentration of BPA in the human serum from 20 individuals was 0.54 pg/ml.  相似文献   

19.
We report here an efficient and comprehensive analytical methodology based on gas chromatography with high resolution mass spectrometry (GC–HRMS) to simultaneously determine PBDEs from mono to deca brominated and hydroxy (OH-) and methoxy (MeO-) PBDE metabolites in environmental samples, particularly, sediment, fish tissue and milk. Among a number of extraction and clean-up methods tested, pressurized liquid extraction followed by gel permeation chromatography and florisil clean-up proved to be simple, robust and optimized so that all target analytes (parent compounds and metabolites) were collected in a single fraction. Extracts were analyzed by GC–HRMS to identify PBDEs. Following, the same extracts were derivatized and re-analyzed by GC–HRMS to determine 11 target and 35 non-target OH- and MeO-PBDEs. Monitoring of the M+ for MeO-PBDEs and the [M−CH2CO]+ ions for derivatized OH-PBDEs at 10,000 resolution permitted unequivocal identification of the PBDE metabolites in the environmental matrices examined. The method was validated in terms of accuracy, precision, detection limits and long-term stability. The analytical precision obtained with this method was between 0.3 and 17%, and the limits of quantification were lower than 3.28 pg/g dry weight, 20.5 and 41.4 pg/g lipid weight in sediment, milk and fish, respectively. The method was applied to determine PBDEs and target and non-target metabolites in all three matrices.  相似文献   

20.
Musk xylene (MX) is frequently used as a fragrance in commercial toiletries. Biotransformation of MX into 4-amino-MX (4-AMX) and 2-amino-MX (2-AMX) metabolites in rainbow trout haemoglobin (Hb) has been described. The dose–response relationship and toxicokinetics of the metabolites as adducts in the Hb were determined by gas chromatography (GC)–electron capture negative chemical ionization (NCI)–mass spectrometry (MS), and GC–electron ionization (EI)–MS/MS, using selected ion monitoring (SIM). The trout were subjected to a single exposure of 0.010, 0.030, 0.10, and/or 0.30?mg?MX/g of fish. Hb samples were collected from exposed and control fish, and analysed subsequent to exposure at intervals of 24, 72, and 168?h. Alkaline hydrolysis released 4-AMX and 2-AMX metabolites from the Hb, and the solutes were extracted into n-hexane. The extracts were preconcentrated and analysed. The presence of the metabolites in the Hb extracts was confirmed based on agreement of similar mass spectral features from NCI/MS and EI-MS/MS spectra, and retention times of the metabolites with standards. The NCI/MS results were used for dose–response and toxicokinetics measurements. For dose–response, the concentrations of adducts of the metabolites increased with dosage, and a maximum adduct formation was observed at 0.10?mg?g?1, beyond which it decreased. The average concentrations of 4-AMX and 2-AMX at a dosage of 0.10?mg?g?1 were 700 and 7.4?ng?g?1, respectively. For toxicokinetics, the concentration of the metabolites in the Hb reached a maximum in the 3 day sample after administration of MX. Further elimination of the metabolites exhibited kinetics with a half-life estimated to be 1–2 days, assuming first-order kinetics. Quantitations were made based on an internal standard and a calibration plot. In control samples, non-hydrolysed Hb, and reagent blank extracts, the metabolites were not detected. The limits of detection for 4-AMX and 2-AMX in the Hb were approximately 1.7 and 1.4?µg?L?1, respectively, based on a signal-to-noise ratio of 3 with NCI/MS.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号