共查询到19条相似文献,搜索用时 140 毫秒
1.
2.
3.
4.
多管排大管径翅管式换热器传热与阻力特性的试验研究 总被引:1,自引:0,他引:1
为考察不同翅片型式对空气侧强化传热的影响,对12排分别带平直、开缝、纵向涡、开缝与纵向涡混合、圆形共5个翅片型式的翅片管换热器元件空气侧的传热及阻力性能进行了试验研究,并在相同质量流木结流量、相同压降及相同泵功率下进行了综合性能评价.在三种比较准则下,圆形翅片的换热综合性能最差,开缝与纵向涡混合翅片的换热综合性能比纵向涡翅片的好,而当Re数较大时开缝翅片的换热综合效果最好.在试验的Re数范围内针对各个试件整理出了传热和阻力的经验关联式,为相关的理论研究和工程应用提供了参考. 相似文献
5.
6.
N─甲基吡咯烷酮两相闭式热虹吸管传热特性的实验研究 总被引:2,自引:0,他引:2
本文报道了用N—甲基吡咯烷酮(C5H9NO3)为工质以光滑管与三维内翅片管为管壳制成的两相闭式逆流热虹吸管的传热特性。实验结果表明在工作温度为220~350℃,热负荷为8.2~17.3kW/m2范围内光滑热虹吸管蒸发段与凝结段换热系数的积分平均值分别约为1700W/m2·℃和1600W/m2·℃。由于三维翅片的强化传热作用,使三维内翅片热虹吸管蒸发段与凝结段换热系数分别比光滑管增大了20%~40%和70%~160%。实验表明N—甲基吡咯烷酮综合传热性能优于萘,可望作为中温热管工质使用。 相似文献
7.
8.
为了研究改变翅片材料对套片式翅片管换热器性能的影响,分别对采用铝翅片和黄铜翅片的套片式翅片管换热器(结构参数基本相同)进行传热特性与空气流动阻力特性的试验。试验得到了试件在一系列试验工况下的传热数据与管外空气流动阻力数据,通过计算得出了相应的传热准则关系式与管外空气流动阻力准则关系式,绘制了传热系数和管外空气流动阻力的有关图线。结果表明:黄铜翅片套片式换热器与铝翅片套片式换热器相比,换热性能优势明显,其原因主要是铝材比铜材软,与铜管胀接后的接触热阻大,因此换热性能更弱。 相似文献
9.
10.
采用数值模拟方法对室外微通道换热器翅片侧空气流动换热性能进行仿真计算, 探讨了在制冷工况下,不同百叶窗结构对微通道换热器空气侧传热及流动特性的影响. 结果表明j 因子的模拟结果与实验关联式之间的平均偏差在7.8% 以内,f 因子的平均误差在7.35 % 以内, 符合工程应用要求. 雷诺数较低时, 传热因子j 和阻力因子f 都随Fp 的增大而减小, 雷诺数较高时,Fp 对两者的影响不明显; 随着开窗角度增加换热器换热系数会呈现先增加后减小的趋势, 同时压降会随开窗角度的增大而有所升高. 相似文献
11.
为研究变角度百叶窗结构对平行流蒸发器换热性能的影响,文中建立了一种均匀角度百叶窗和两种变角度百叶窗的计算模型;采用fluent软件数值模拟了空气侧的传热和流动过程,得到了百叶窗翅片的速度场、温度场及压力场;将数值模拟结果与相关文献实验关联式结果进行对比,验证了数值模拟的可行性,分析了迎面风速对换热和压降特性的影响;并利用公式j/f1/3,比较了三种翅片的综合性能,发现变角度百叶窗翅片综合性能优于均匀角度百叶窗翅片。 相似文献
12.
13.
基于空气源热泵在低温寒冷地区运行中遇到的结霜问题,对不同风速工况下,结霜过程中设备性能的变化进行分析,以换热量、换热系数为指标对不同翅型换热器的换热特性进行研究。实验结果显示:换热器结霜过程中,换热过程主要分为初始增加段、换热平稳段、缓慢衰减段、后期平稳等四段,结晶体在增加空气湍流度强化换热的同时,也增加了换热热阻使换热效果变差,因此换热效果本质而言是两种换热效果的综合体现;空气阻力随风速的增大、结霜量的增加而增大,而蒸发压力随着风速的增加而升高、随结霜量的增大而减小;百叶窗翅片表面结霜量大于平翅片,因此平翅片翅型当量换热系数更大,翅片结霜量、当量换热系数随风速的增加而增大,风速由1 m/s增至4 m/s时,结霜量、当量换热系数增加约三倍。 相似文献
14.
An investigation of heat transfer and pressure drop from some louvered surfaces is presented. The test rig and the measuring as well as the data evaluating procedures are described. The measured data are transferred and presented in a nondimenswnal form. The heal transfer data are provided mainly as Stanton numbers versus Reynolds number, and the pressure drop is given as Darcy friction factors versus Reynolds number. For comparing the performance of the various louvered surfaces, the flow area goodness factors and the so-called volume goodness factors are presented. All the louvered surfaces have been found to be more efficient than the corresponding smooth surface. The standard multilouvered fin surfaces were found to be most efficient, but one of the new surfaces also performed very well. 相似文献
15.
The flow patterns and wall stresses in a two‐dimensional louvered moving granular filter bed of quartz sand were investigated. The flow pattern histories of granular solids in the filter bed were recorded using a digital camcorder and a pressure gauge for simultaneously measuring the normal stresses as well as shear stresses of the granular solids. The static wall stress distributions produced by the granular solids were measured, and agreed with a theoretical prediction formed using the differential slice and Runge‐Kutta (order four) methods. The variations in the dynamic wall stresses with time in a moving granular filter bed were obtained and the effect of the louver angle upon the flow patterns and wall stresses was also investigated. Employing the results obtained by stress measurements and image processing, the wall pressure pulsation phenomena in a moving granular filter bed may be further understood. The results reported here provide fundamental information for the design of moving granular filter beds to act as high‐temperature flue gas cleanup filters. 相似文献
16.
提出一种新的针肋结构,采用直径为0.25 mm的圆柱型针肋,在一定的错排和顺排相结合的优化布置方式下,能获得较高的换热效率.在三维空间上的对流换热模拟表明,铜制的针肋结构的换热系数要高出百叶窗翅片24%~34%,而流阻仅高出10%~16%.总换热量取决于翅片材料的导热性能,导热系数越高,针肋的强化作用约明显.本文提出的针肋翅片结构可以用来制造紧凑性更高的换热器. 相似文献
17.
带间断性矩肋的平行平板通道中三维流动与换热的数值模拟 总被引:1,自引:0,他引:1
1数学描述与计算方法周期性变化的几何结构是广泛应用的一种强化换热形式*‘]。文献中有关的数值研究多限于二维清形,三维的研究相对较少。本文针对沿流向周期性布置矩肋的平行平板通道,对层流周期性充分发展的流动与换热进行了三维数值模拟。计算单元如图1所示。对于不可压缩流体,忽略体积力时的控制方程为:图1矩助通道计算单元表1式(l)中各乡变量的含义式中d取不同值的对应关系见表1。设通道几何周期长度为S,则对充分发展状态的计算单元进出边界有如下关系:据文献*,周期性充分发展流动的压力可以分解为两部分:式中o为一个周… 相似文献
18.
19.
本文利用传热传质之间的比拟关系研究了错排环布圆管换热板芯的平均传热特性及阻力特性。实验中我们采用了三种翅片间距(Tp)、三种管排数(Nrow)以及三种管数(Ntube)组成的27种板芯结构,传质实验采用萘升华的方法来进行。然后通过三种限制条件对不同翅片间距、不同管排数和不同管数下的换热板芯的传热性能进行了比较。最后利用最小二乘法得出了具有工程指导意义的准则关联式。 相似文献