首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A simple and novel electrogenerated chemiluminescence (ECL) method for the determination of sulfite has been developed based on the energy transfer ECL process. It was found that a weak ECL signal of sulfite was electrochemically generated on a platinum electrode in neutral aqueous solution. The signal was strongly enhanced by rhodamine B as an energy receptor and further enhanced by the neutral surfactant Tween 80. In 0.10M phosphate buffer solution (pH=7.5) containing 2.0×10–6gmL–1 rhodamine B and 0.4% (v/v) Tween 80, the ECL response to the concentration of sulfite at a potential of 0.82V was linear over a range of 1.0×10–7gmL–1 to 8.0×10–6gmL–1, and the detection limit was 5×10–8gmL–1. The relative standard deviation (n=11, 1.0×10–6gmL–1) was 3.8%. The proposed method has been successfully applied to the determination of sulfite in pharmaceutical injections and white sugar samples.  相似文献   

2.
Mixed ligand complexes involving four aminoacid dithiocarbamates (RRdtc=glydtc (R=H; R=H), methdtc (R=H; R=C3H7S), sardtc (R=Me; R=H), trydtc (R=H; R=C9H8N), substituted phosphines [PPh3, Ph2PCH2CH2PPh2(dppe)] and nickel(II) are reported. All are diamagnetic. Thermal analyses of the complexes are in keeping with the proposed formulae. Thermal decomposition of the dithiocarbamate moiety proceeds through the formation of Ni(SCN)2. PPh3 and dppe are lost in the initial decomposition stages.  相似文献   

3.
A medium power radiofrequency capacitively coupled plasma (275W, 27.12MHz) with low argon consumption (0.5Lmin–1) was investigated to be used for the determination of aluminium in water samples pneumatically nebulised by atomic emission spectrometry. The plasma torch was operated in two geometric configurations, coaxial and coaxial-annular with single (SRTr.f.CCP) or double ring electrodes (DRTr.f.CCP), respectively. The optimum experimental parameters (observation height, Ar flow rate, distance between ring electrodes, matrix interference of Na+ and Ca2+ and anion nature) for Al 396.152nm emission were established. Under optimum operating conditions of the DRTr.f.CCP torch (6cm distance between annular electrodes), a detection limit of 70ngmL–1 aluminium was found. Both operating parameters and several figures of merit of the investigated plasmas were compared to those of microwave plasmas and inductively coupled plasma used in atomic emission spectrometry. The method was used to control the quality of drinking and industrial water. Samples were mineralised with 2mL of 1+1 HNO3 and 10mL of 1+1 HCl. In the range of 0.15–3.5mgL–1 Al3+ the relative standard deviation varied between 3.7 and 8.6% (n=3). For two certified drinking water samples containing 0.206 and 0.218mgL–1 Al3+ the recovery (n=5) was 97.6±6.8% and 98.6±7.3%, respectively.  相似文献   

4.
Electrogenerated chemiluminescences (ECLs) of quinolizidine alkaloids including matrine (MT), sophocarpine (SC), and sophoridine (SRI) are studied. The light emission is caused by an electro-oxidation reaction between Ru(bpy)32+ and the tertiary amino group on the alkaloid compounds. A thin-layer flow cell equipped with a glassy carbon disk electrode (22.1mm2) at the potential of +1.30V (vs. Ag/AgCl) was applied for ECL observation. MT, SC and SRI were separated and quantitatively determined within 25min by an ODS-80 Ts reversed-phase column with a mobile phase containing 80mmolL–1 NaH2PO4–K2HPO4 buffer+acetonitrile (7:3)+40mmolL–1 sodium dodecyl sulfate (pH 6.5). The determination limit at an S/N of 3 ranged from 3×10–9gmL–1 for MT, 6×10–9gmL–1 for SC and 1×10–9gmL–1 for SRI. The recoveries are from 92 to 108%, with repeatability ranging from 1.3 to 4.5% (relative standard deviation). The method was successfully applied to the determination of quinolizidine alkaloids in Sophora flavescens samples.  相似文献   

5.
A sensitive derivative adsorption chronopotentiometric method was developed to determine trace amounts of Fe3+. The influence of preconcentration time, pH of solution and constant reducing current of the peak height is discussed. The detection limit and the linear range are 5.0×10–10 and 2.0×10–93.0×10–6molL–1, respectively. The method was used to determine trace Fe3+ in KH2PO4 crystals (KDP).  相似文献   

6.
This study aims to investigate the distribution of Na, K, Rb and Cs in human brains (5 individuals, 12 brain parts, mean age: 75 years). Distribution of the trace metals between lipid fraction and brain tissue was investigated in solvent extraction experiments. Determinations were carried out by instrumental neutron activation analysis. The present results show a rather non-homogeneous distribution for Na and a relatively uniform distribution for K, Rb and Cs. The mean concentrations found are 7440µgNag–1 dry weight, 12800µgKg–1, 14µgRbg–1 and 50ngCsg–1. A highly significant positive correlation was found between Rb and Cs. Solvent extraction experiments showed that 19% of Rb and 26% of Cs of the total content is located in lipid fraction.  相似文献   

7.
The fabrication and electrochemical characteristics of a penicillamine (PCA) self-assembled monolayer modified gold electrode were investigated. The self-assembled electrode shows obvious electrocatalytic activity for the oxidation of epinephrine (EP). In phosphate buffer (pH 7.73), a sensitive oxidation peak was observed at 0.190V with the PCA modified Au electrode. The peak current is proportional to the concentration of EP in the range of 2.0×10–56.0×10–4molL–1 and 5.0×10–6 2.0×10–4molL–1 for cyclic voltammetry (CV) and differential pulse voltammetry (DPV) with the detection limits of 1.8×10–7 and 1.3×10–7molL–1, respectively. The possible reaction mechanism is also discussed. The PCA self-assembled monolayer modified gold electrode is highly stable and can be applied to the determination of EP in practical injection samples. Application is simple, rapid and produces accurate results.  相似文献   

8.
The kinetics of formation and dissociation reactions of [Ru(CN)5L]3– with a series of heterocyclic ligands were studied in aqueous media. In this presence of an excess of heterocycle, the observed second order rate constants were calculated from the kobs versus [ligand] plot at =0.100m NaClO4. Activation parameters for the formation reactions (H=28±7kJmol–1 and S=140±35JK–1mol–1) are comparable for all systems, indicating a common mechanism. The kinetics of exchange of coordinated heterocycles for 1,3,5-triazine yielded a rate saturation typical of a limiting dissociative mechanism. Activation parameters of the limiting first order specific rate of dissociation reactions were H=85±7kJmol–1 and S=18±4JK–1mol–1. Equilibrium constants were calculated from the second order rates of formation and pseudo-first order rates of dissociation reaction.  相似文献   

9.
A carbon black microelectrode modified by -MnO2 has been prepared. The electrocatalytical oxidation of ascorbic acid (AA) at this microelectrode was investigated. The 2nd-order linear scan voltammograms of AA are recorded from –0.5 to 0.5V (vs. SCE). The relationship between the oxidation peak current of AA and its concentration in the range of 1.0×10–64.0×10–3molL–1 is linear. The detection limit (3) was found to be 6.0×10–7molL–1. Also, the determination of AA in samples is evaluated, and the results are satisfactory.  相似文献   

10.
Solvent sublation was studied as a method of separating and pre-concentrating traces of Zn(II), Cd(II) and Cu(II) as diphenylthiocarbazone (dithizone) complexes for their determination. The experimental conditions, such as pH of solution, amount of dithizone as ligand, stirring time, gas flow rate and flotation time, were optimized. Different non-ionic surfactants and types of organic solvents were optimized for efficient sublation. The analyte ions in a 350mL sample were complexed as metal-dithizone complexes by adding 10mL of 0.084% dithizone, 0.5mL of 0.1% nonylphenol polyoxyethylene ether (NP) and 10mL of pH 4.3 potassium hydrogen phthalate-sodium hydroxide buffer solution. The solution was stirred with a mechanical stirrer for 30min. It was transferred to a flotation cell, and the complexes were floated by bubbling air and extracted into 10mL of methylisobutyl ketone (MIBK) on the surface of the aqueous solution. The analytes in the organic phase were determined by flame atomic absorption spectrometry (F-AAS) for Zn(II) and by graphite furnace atomic absorption spectrometry (GF-AAS) for Cd(II) and Cu(II). The proposed method was applied to determine Zn(II), Cd(II) and Cu(II) in real water samples; the enrichment factor was more than 37, the RSD was less than 4.26%, recoveries ranged from 92.7 to 107.3%, and the detection limits were 1.0µgL–1 for Zn(II), 0.006µgL–1 for Cd(II) and 0.06µgL–1 for Cu(II). The results obtained were satisfactory.  相似文献   

11.
A -mercaptopropionic acid (MPA) self-assembled monolayer modified electrode (MPA/SAM/Au) on a gold electrode has been fabricated. The characterization of the MPA/SAM/Au was investigated using attenuated total reflection-fourier transform infrared (ATR-FTIR) and A.C. impedance. The electrochemical behaviors of p-aminophenol (p-AP) were studied at the MPA/SAM/Au by cyclic voltammetry and semi-derivative voltammetry (SDV) in BR buffer solution. The modified electrode shows excellent electrocatalytic activity for the redox of p-AP and accelerates the electron transfer rate. The diffusion coefficient (D) is 4.55×10–6cm2s–1. The oxidative peak current increases linearly with the concentration of p-AP in the range of 4.0×10–88×10–6molL–1 and 1.0×10–52×10–4molL–1 by square wave voltammetry response, respectively. The detection limit (three times the signal blank/slope) is up to 1.2×10–8molL–1. The modified electrode is able to eliminate the interference of p-benzenediol, o-benzenediol and o-AP at a 40-, 90- or 70-fold concentration of p-AP, and it has been satisfactorily used for the determination of the real sample.  相似文献   

12.
A novel electroanalytical method for the determination of physcion is described for the first time. Physcion yields an adsorption catalytic voltammetric peak at –0.74V (vs. SCE) in 0.4molL–1 NH4Cl–NH3·H2O buffer solution (pH 10.5) at a carbon paste electrode (CPE). The experimental results indicated that physcion is efficiently accumulated at a CPE by adsorption. In the subsequent potential scan, physcion was reduced to a homologous anthrahydroquinone compound. The compound was then immediately oxidized to physcion by the dissolved oxygen in the solution, and then physcion was again reduced at the CPE. As a result, a cyclic catalytic reaction was established. The second-order derivative peak current is proportional to the physcion concentration in the ranges of 2.0×10–104.0×10–9molL–1 (accumulation 90s) and 4.0×10–92.0×10–8molL–1 (accumulation 60s). The limit of detection is 8×10–11molL–1 (S/N=3) for a 120s accumulation time. The method was applied to the direct determination of physcion in the medicinal plant polygonum multiflorum Thumb with satisfactory results.  相似文献   

13.
A flow injection hydride generation graphite furnace atomic absorption spectrometric (FI-HG-GFAAS) method was applied to the determination of Se in Se-doped and undoped cereals and bakery products. For the purpose of doping, the soils used for the cultivation of the cereals were dosed with Se-doped foliar fertilizers. The samples were dissolved in a mixture of HNO3 and H2O2 solutions using microwave-assisted digestion. The decomposition of H2Se generated from the sample solutions and the trapping of elemental Se were performed at a temperature of 300°C on an Ir-pretreated integrated graphite platform of a transversally heated graphite atomizer (THGA). For release of the trapped Se within a fairly short atomization time (5s), an atomization temperature of 2200°C was observed to be optimal. The overall efficiency of hydride generation, transport and trapping was 86%.The upper limit of the linear dynamic range of calibration was 10µgL–1, which corresponds to 0.5µgg–1 for solid samples. Recovery of the samples spiked with SeVI solutions was found to be 93±6% on average. The relative standard deviation of the determinations was less than 8%. The limit of detection was found to be 0.06µgL–1, corresponding to 3ngg–1 for solid samples. The accuracy of the method was verified with the use of IAEA-155 (whey powder) certified reference material. End-capped THGA tubes resulted in an extension of the linear calibration range compared to that of standard THGAs.The Se content in bakery products made of undoped cereals ranged from 7.7 to 68ngg–1 (wet weight) in 18 samples, whereas the Se content of the corresponding cereals was found to be below 100ngg–1 (wet weight). The Se level of cereals grown on soils treated with Se-doped fertilizers ranged from 128 to 1046ngg–1 (wet weight), and it depended linearly on the Se concentration of the corresponding foliar fertilizer.  相似文献   

14.
A new approach, based on non-aqueous capillary electrophoresis separation and indirect photometric detection, was established for the determination of the transition metal ions Pb2+, Zn2+ and Cd2+. Under optimized conditions, the method produced baseline separation of these three metal ions. The linear range and detection limits were 1050µM, 1.9µM for Cd2+; 1050µM, 2.1µM for Zn2+; and 20100µM, 3.8µM for Pb2+, respectively.  相似文献   

15.
A sensitive chemiluminescence method for the determination of acetylspiramycin is presented. It is based on the greatly enhancive effect of acetylspiramycin on the chemiluminescence reaction between luminol and hydrogen peroxide in the flow system. The increase in chemiluminescence intensity was linearly proportional to the acetylspiramycin concentration in the range from 10pg·mL–1 to 2.0ng·mL–1 (r2=0.9979). The detection limit was 3pg·mL–1 (3). At a flow rate of 2.0mL·min–1, the process of determination, including sampling and washing, could be performed in 0.5 min, and the relative standard deviations of seven replicates are less than 5.0%. The proposed method was applied successfully to the determination of acetylspiramycin in pharmaceutical preparations, human urine and serum without pre-treatment. It was found that the excretive ratio of acetylspiramycin reached its maximum 2.0 hours after having been administered orally, and the excretive ratio in 12.0 hours was 8.4.  相似文献   

16.
Cinnamtannin B1 (trimeric proanthocyanidin), which is identified and isolated from the effective fraction of the root of Lindera aggregata (Sims) Kosterm, is one kind of condensed tannin used as an effective antipyrotic and antitumor agent. Its electrochemical response can be obtained at a pyrolytic graphite electrode. Consequently, an easily performed and sensitive method for the determination of cinnamtannin B1 is developed. The detection limit is estimated to be 1.0×10–7M with the linear determination range of 2.0×10–7M to 1.8×10–6M. Five replicate analyses of 1.0×10–6M cinnamtannin B1 yields an RSD value of 2.1%. Since the working electrode does not need to be modified with any other species, it is very stable, repeatable and easily treated, and this method therefore potentially useful in real sample analysis.  相似文献   

17.
Nanometer-sized L-cysteine-capped ZnS particles were synthesized by a colloidal aqueous method. The functionalized nanoparticles are water-soluble and suitable for biological applications. In Tris-HCl buffer solution, nucleic acids combine with cysteine-capped nano-ZnS particles by intermolecular forces to form larger nanoparticles. There are two resonance light scattering peaks at 304.5nm and 373.8nm, respectively. The enhanced RLS is related to the concentration of nucleic acids in the range of 0.04 to 1.2µgmL–1 for calf thymus DNA and 0.2 to 1.0µgmL–1 for fish sperm DNA. The detection limits (3) are 19ngmL–1 for calf thymus DNA and 23ngmL–1 for fish sperm DNA, respectively. Four synthetic samples were analyzed satisfactorily.  相似文献   

18.
Thallium in natural water samples was determined by electrothermal atomic absorption spectrometry after 1000-fold enrichment by mini solid-phase extraction from a 100-mL sample solution. A Tl-pyrrolidine-1-carbodithioate complex formed in a sample solution of pH 1.6 was extracted on fine particles of a cellulose nitrate resin dispersed in the sample solution. The cellulose nitrate resin was then collected on a membrane filter (25mmø) by filtration under suction using a glass funnel with an effective filtration area of 0.64cm2. As a result, a circular thin layer of the resin phase with a diameter of 9mm was obtained. Then the resin phase was carved out by an acrylate resin puncher with a 10-mmø hole to put it into a sample cup containing 100µL of 10mM HNO3 containing 0.5mM NaCl. The resin phase was suspended in the solution by ultrasonication. 1000-fold enrichment was thus attained within 15min, and the suspension was delivered to electrothermal atomic absorption spectrometry. The linear calibration graph was obtained in the range of 0–4ng of Tl in 100mL of a sample solution. The detection limit obtained by 3 method was 0.19ng. The proposed method was applied to the determination of Tl in natural water samples. The results showed the concentration of Tl in seawater was 12.1±1.8pgmL–1 for the calibration graph method and 12.6±1.4pgmL–1 for the standard addition method. A snowmelt sample contained 20.7±1.0pgmL–1 of Tl.  相似文献   

19.
A microcolumn on-line preconcentration and separation system was developed for the flame atomic absorption spectrometric (FAAS) determination of trace levels of gold and palladium. The analytes were selectively adsorbed onto the microcolumn packed with 2-mercaptothiazole immobilized silica gel (MBTSG) in an acidity range of 0.1 to 6.0M HCl at a sampling flow rate of 4.0mLmin–1. The analytes adsorbed could be desorbed by a thiourea solution with a flow rate of 2.0mLmin–1. Most of the common coexisting metal ions at a concentration of 25.0mgmL–1 and anions at a concentration of 50.0mgmL–1 did not interfere with the preconcentration and determination of Au and Pd. The limits of detection (LOD), defined as three times the standard deviation of the blank (3), of Au and Pd are 10ngmL–1 and 26ngmL–1, respectively, with a preconcentration time of 60s. The relative standard deviation (RSD) is about 2.0% for 0.20µgmL–1 Au and 0.30µgmL–1 Pd. With a sample loading time of 30min, 6.7ngmL–1 Au and 10ngmL–1 Pd can be preconcentrated quantitatively. A geological sample, an anode slime and a secondary nickel alloy were successfully determined with the proposed method, and the results obtained showed good agreement with the certified values.Received December 23, 2002; accepted May 14, 2003 Published online August 8, 2003  相似文献   

20.
A sensitive and fast analytical method using purge-and-trap on-line coupling with gas chromatography was developed for the determination of trace volatile sulfur compounds including dimethyl sulfide (DMS), ethyl-methyl sulfide (EMS), and dimethyl disulfide (DMDS) in beverage and coffee samples. The analytes were purged for 12min from the sample by high purity nitrogen at a flow rate of 35KPa and preconcentrated in the cooled fused-silica capillary trap at –75°C. The NaCl content in the samples was maintained at 10%. The volatile sulfur compounds were separated with an Agilent-6890 gas chromatograph by a suitable temperature program and detected by means of a flame photometric detector (FPD). The detection limits were 80ngL–1 for DMS, 80ngL–1 for EMS, and 100ngL–1 for DMDS, respectively. This method was successfully applied to the determination of volatile sulfur compounds in different beverage and coffee samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号