首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A sensitive and efficient solid-phase microextraction (SPME) method for the determination of seven pyrethroid insecticides including fenpropathrin, λ-cyhalothrin, deltamethrin, fenvalerate, permethrin, τ-fluvalinate and bifenthrin in cucumber and watermelon samples using high performance liquid chromatography combined with post-column photochemically induced fluorimetry derivatization and fluorescence detection (SPME-HPLC-PIF-FD) was developed and validated. The optimum SPME conditions were used for the extraction of samples of both matrices (extraction time 30 min, stirring rate 1100 rpm, extraction temperature 65 °C, sample pH 3, soaking time 7 min, desorption time 5 min, ACN content 25%, desorption and soaking solvent was the mobile phase and in static mode). The method was validated in terms of limits of detection (LODs) and the limits of quantification (LOQs) in both IUPAC and EURACHEM criteria. LODs and LOQs were achieved in values lower than the maximum residue levels (MRLs) established in the Spanish regulations for all pesticides in this study (MRLs range between 0.01 and 0.1 mg kg−1 for all pyrethroid insecticides in both matrices). LOQs according to the second criterion were between 1.5 and 5 μg kg−1 for cucumber; and between 1.3 and 5 μg kg−1 for watermelon samples. Precision and recovery studies were evaluated at two concentration levels for each matrix. Good precision was obtained and relative standard deviation values were less than 10% in all cases. Recovery values were calculated at 0.05 and 0.5 mg kg−1 levels (n = 6) and they ranged between 93% and 108% for cucumber and between 91% and 110% for watermelon samples. Applicability of the method to pyrethroids in cucumber and watermelon of commercial samples was demonstrated.  相似文献   

2.
A solid-phase microextraction (SPME) method has been developed for the determination of six benzoylureas (diflubenzuron, triflumuron, hexaflumuron, teflubenzuron, lufenuron, and flufenoxuron) in natural orange juice based on the direct immersion mode of a 60 microm polydimethylsiloxane/divinylbenzene fiber. An orange juice was obtained from blended, homogenized, and diluted ecological natural orange juice samples. An aliquot of 3 mL of a spiked sample was extracted under optimum SPME conditions. The determination of benzoylureas was carried out using HPLC combined with post-column photochemically induced fluorimetry derivatization and fluorescence detection. The limits of quantification obtained in matrix were within the range of 0.02 to 0.04 mg/kg and these limits are lower than the maximum residue levels established in Spanish regulations for all pesticides in this study. Recoveries in juice samples ranged between 85 and 110% and relative standard deviations between 1.8 and 7.4%.  相似文献   

3.
This study examines the application of solid-phase microextraction coupled with high performance liquid chromatography combined with post-column photochemically induced fluorimetry derivatization and fluorescence detection (SPME-HPLC-PIF-FD) for the determination of four phenylurea herbicides (monolinuron, diuron, linuron and neburon) and propanil in groundwater. Direct immersion (DI) SPME was applied using a 60 μm polydimethylsiloxane/divinylbenzene (PDMS/DVB) fiber for the extraction of the pesticides from groundwater samples. An AQUASIL C18 column (150 mm × 4.6 mm i.d., 5 μm) was used for separation and determination in HPLC. The method was evaluated with respect to the limits of detection (LODs) and the limits of quantification (LOQs) according to IUPAC. The limits of detection varied between 0.019 μg L−1 and 0.034 μg L−1. Limits of quantification ranged between 0.051 μg L−1 and 0.088 μg L−1. These values meet the recommended limits for individual pesticides in groundwater (0.1 μg L−1) established by the EU. Recoveries ranged between 86% and 105% and relative standard deviation values between 2% and 8%.  相似文献   

4.
This study reports the first application of coupled-column liquid chromatography–photochemically induced fluorimetry–fluorescence detection (LC-LC-PIF-FD), demonstrating its potential for the quantitative and selective detection of seven pyrethroids in vegetable samples such as cucumber, green bean, tomato and aubergine. An internal surface reversed-phase (ISRP) column coupled to a C18 column for analyte clean-up and determination were used, respectively. In comparison with a C18 column, the ISRP substantially improved the separation between analytes and interferences from the vegetable matrix. The limits of detection ranged from 0.01 to 0.22 g kg–1 in the vegetable samples (equivalent to 0.01 and 0.13 g L–1 in the extract injected), and limits of determination ranged from 0.56 to 8.33 g kg–1 in the vegetable samples (equivalent to 0.34 and 5.00 g L–1 in the extract injected). Samples were extracted into dichloromethane to yield mean recoveries at two levels of concentration between 72.8 and 110.0% in all cases. Relative standard deviations were lower than 11%.  相似文献   

5.
A simple and accurate cleanup procedure using polymeric sorbent was developed for the determination of oxytetracycline (OTC) and tetracycline (TC) residues in salmon muscle. It was applied to the analysis of 20 salmon samples during a month period. The OTC and TC residues were extracted with ethylenediaminetetracetic acid (EDTA)-McIlvaine buffer acidified at pH 4.0 and cleaned up by solid-phase extraction with a polymeric sorbent. The advantages of the polymeric sorbent over the silica-based sorbent in the cleanup of salmon muscle samples are described. A liquid chromatographic method with post-column derivatization and fluorescence detection is proposed because of its sensitivity and specificity. The average recoveries of OTC and TC from muscle salmon tissue fortified at 50, 100, and 200 microg/kg levels, ranged from 83.9 to 93.4% with a coefficient of variation between 4.09 and 5.80%. The limit of quantitation for OTC and TC in salmon muscle was 50 microg/kg.  相似文献   

6.
Coquet  A.  Haerdi  W.  Degli Agosti  R.  Veuthey  J. -L. 《Chromatographia》1994,38(1-2):12-16
Summary A method for the determination of reducing sugars such as fructose and glucose and nonreducing sugar such as sucrose by high performance liquid chromatography followed by an acidic hydrolysis and a derivatization with benzamidine has been developed. After separation of sugars on a gel column packed with a polymer-based cation exchange material (Sugar-Pak I, Waters-Millipore), the sucrose is first hydrolysed in a solid phase reactor to convert it into reducing subunits. A post-column fluorigenic reaction with benzamidine under alkaline condition allows the selective determination of both natural and converted reducing carbohydrates.This procedure has proven to be selective (fluorigenic detection) and highly sensitive (allowing detection as little as picomoles amounts), reproducible and linear over a broad range of concentrations: 5×10–4 to 1.0×10–2 M.The applicability of this method to natural matrices such as plant extracts and beverages is also described. The sugar content of a barley extract has been determined and compared with a specific enzymatic test. The determined sugar content of natural and commercial lemon juices as well as of Cola beverages has been compared with those found by the conventional LC refractive index analytical procedure. In all cases, the results were comparable and were within the experimental errors of the methods.  相似文献   

7.
Artemisinin (an antimalaric compound) is isolated as the active compound of the medicinal plant Artemisia annua L. A simple, rapid, and high-efficient method of extraction is developed, in which it is extracted by matrix solid-phase dispersion (MSPD) and directly analyzed by post-column derivatization high-performance liquid chromatography (HPLC). The quantitation results from the MSPD method are compared with two conventional liquid solvent extraction processes, Soxhlet and ultrasonic wave by F-test, and the result indicates no significant difference. The production rate of Artemisinin during wild plant growth (tested over two years, acquired from Yunnan, provincial Yuan Yan country) is determined. The recovery range of determination is 88.1-91.2%. The relative standard deviation (RSD) is 4.55-6.43%. The limits of detection are 0.1 microg/mL, and the limits of quantitation are 0.5 microg/mL.  相似文献   

8.
This study examines the application of coupled-column LC-photochemically induced fluorimetry-fluorescence detection (LC-LC-PIF-FD), demonstrating its potential for the quantitative and selective detection of six herbicides, including propanil and the phenylureas monuron, monolinuron, chlorotoluron, diuron and neburon in groundwater samples. An AQUASIL C18 50 x 4.6 mm(2) id column coupled to an AQUASIL C18 150 x 4.6 mm(2) id column for analyte clean-up and determination were used, respectively. A simple SPE with Cl8 cartridges was carried out, yielding average recoveries between 80 and 112% (n = 6) with RSDs between 0.5 and 9%. The LODs ranged from 0.0083 to 0.0833 microg/L in the groundwater samples.  相似文献   

9.
Summary The use of solid-phase reactors for post-column derivatization in narrow-bore HPLC (1.0mm i.d. analytical columns) is evaluated. Two systems are described, viz. for the determination of N-methylcarbamate pesticides and for that of urea and ammonia. The solid-phase reactor is packed with a strong anion exchange resin and urease immobilized on silica, respectively, to effect the catalytic hydrolysis of the solutes eluting from the analytical column. In both systems, the hydrolysis product is reacted with o-phthalaldehyde followed by fluorescence monitoring. Analytical data are presented and band broadening from various parts of the reaction detector system is discussed. An on-line trace enrichment procedure via a micro precolumn is descried for the trace level determination of N-methylcaramates in surface water samples.  相似文献   

10.
The coupled-column (LC-LC) system, consisting of a first column packed with internal surface reversed phase (ISRP) (50 x 4.6mm ID) and a Chrompack C18 (100 x 4.6 mm ID) as second column, allowed the simultaneous determination of five benzoylurea insecticides in dichloromethane (CH2Cl2) extracts of vegetable samples without any clean-up step. This system was combined with a photochemically induced fluorescence (PIF) post-column derivatization in order to provide strongly fluorescent photoproducts from the non-fluorescent benzoylureas. Limits of detection ranged from 0.21 to 0.98 microg L(-1) of pesticide (equivalent to 0.14-0.65 microg kg(-1) in vegetable samples) and limits of determination ranged from 4.0 to 10.0 microg L(-1) (equivalent to 2.7-6.7 microg kg(-1)). Linearity of the method was established between 2 and 1800 microg L(-1), depending upon the compound. Validation of the total method was performed by randomly analyzing recoveries of four vegetable samples (aubergine, cucumber, green bean, and tomato) spiked at two levels of concentration (10.0 and 33.3 microg kg(-1)). The combination of the LC-LC system with PIF detection provides a sensitive, selective, and rapid method for the determination of pesticides in vegetable samples at levels lower than the maximum residue levels (MRLs) established for these compounds by Spanish legislation.  相似文献   

11.
A styrene/divinylbenzene polymer column and an amino column are compared for the non-aqueous separation of primary, secondary and tertiary alkylamines. Post-column derivatization with o-phthalaldehyde/2-mercaptoethanol is selective for primary amines and derivatization with 7-chloro-4-nitrobenzo-2-oxa-1,3-diazole (NBD-Cl) is selective for secondary amines after on-line masking of primary amines. This procedure can tolerate 0.4 M butylamine. The limit of detection is 18.5 mM for dioctylamine (with NBD-Cl) and 0.18 mM for decylamine and tetraethylenepentamine (with o-phthalaldehyde/2-mercaptoethanol).  相似文献   

12.
A reliable and sensitive procedure is presented for the analysis of streptomycin (STP) in food of animal origin, like meat, milk and honey. The method is based on a separation by ion-pair liquid chromatography with β-naphthoquinone-4-sulfonate (NQS) postderivatization and fluorescence detection. The clean-up of the extract is done by solid-phase extraction, firstly with a cation-exchange cartridge and secondly with an octadecyl cartridge. The selectivity is very good and not many interfering peaks are observed for various food matrices. The streptomycin recovery of the total procedure is superior to 80%. The procedure is quantitatively characterized and repeatability, linearity, detection and quantification limits are very satisfactory. A special focus is given to STP residues in honeys and a survey on 64 commercial honeys is presented. For honey analysis, the HPLC method is compared with an immunoassay test (ELISA), and the possibility of using this test for screening with and without solid-phase extraction clean-up is also discussed.  相似文献   

13.
A new method for the determination of aflatoxins B1, B2, G1, and G2 (AFB1, AFB2, AFG1, AFG2) in cereal flours based on solid-phase microextraction (SPME) coupled with high performance liquid chromatography with post-column photochemical derivatization and fluorescence detection (SPME–HPLC–PD–FD) has been developed. Aflatoxins were extracted from cereal flour samples by a methanol:phosphate buffer (pH 5.8, I = 0.1) (80:20, v/v) solution, followed by a SPME step. Different SPME and HPLC–PD–FD parameters (fiber polarity, temperature, pH, ionic strength, adsorption and desorption time, mobile phase) have been investigated and optimized. This method, which was assessed for the analysis of different cereal flours, showed interesting results in terms of LOD (from 0.035 to 0.2 ng g−1), LOQ (from 0.1 to 0.63 ng g−1, respectively), within and inter-day repeatability (2.27% and 5.38%, respectively) linear ranges (up to 20 ng g−1 for AFB1 and AFG1 and 6 ng g−1 for AFB2 and AFG2), and total raw extraction efficiency (in the range 55–59% at concentrations in the range 0.3–1 ng g−1 and 49–52% at concentrations in the range 1–10 ng g−1). The results were also compared with the purification step carried out by conventional immunoaffinity columns.  相似文献   

14.
A HPLC/fluorescence method with on-line post-column derivatization by a photoreactor was developed, where alpha-, beta + gamma- and delta-tocopherolquinone (TQ) are separated on a 250 mm x 4.6 mm RP-18 column. The LOD is about 250 pg for all TQs. In combination with a two-step sample preparation procedure, this method was successfully employed for measurement of alpha-TQ in human serum samples. Recovery for alpha-TQ from spiked serum was excellent (99 +/- 5%) and results of alpha-TQ determinations in 111 serum samples are reported. Additionally, possibilities for determination of other TQs in serum and alternative derivatization with a zinc reduction column are discussed.  相似文献   

15.
A simple high-performance liquid chromatographic method for the determination of 2-deoxy-D-glucose and D-glucose in rat serum is described; this method is based on a post-column fluorescence derivatization. The sugars are automatically converted into fluorescent derivatives by reaction with meso-1,2-bis(4-methoxyphenyl)ethylenediamine in an alkaline medium after their separation on a strong anion exchanger column (TSK gel Sugar AXG). The detection limits (S/N = 3) for 2-deoxy-D-glucose and D-glucose in rat serum are 0.52 and 0.56 nmol/ml, respectively.  相似文献   

16.
The determination of imidacloprid and its main metabolite (6-chloronicotinic acid) in honeybees was performed by liquid chromatography with post-column photochemical derivatisation in alkaline medium and fluorescence detection. The compounds were extracted from honeybees with acetone under ultrasound conditions prior to liquid-liquid partition with dichloromethane. The separation of extract components was performed using a 50 mm x 4.6 mm i.d. short column packed with 5 microm Aquasil C(18) using an acetonitrile:water gradient program as mobile phase. Injection of samples in 0.1 mol L(-1) H(3)PO(4)/KH(2)PO(4) buffer solution (pH 3) improved the chromatographic separation between the most polar components of matrix and the 6-chloronicotinic acid. Matrix components were removed to waste using an on-line clean-up method previously to post-column reaction. Limits of quantification were 0.3 and 5.0 microg L(-1) (corresponding to 1.2 and 20.0 microg kg(-1) in the honeybee sample) for imidacloprid and 6-chloronicotinic acid, respectively. The recovery was ranged from 80.2 to 91.7% with a relative standard deviation lower than 9.0%.  相似文献   

17.
18.
A fast, specific and sensitive high-performance liquid chromatographic procedure for the determination of cefatrizine, an orally active cephalosporin, in serum and urine is proposed. The drug is determined by the internal standard method, using cephradine as the internal standard. The separation is carried out on a reversed-phase column, filled with octadecylsilane chemically bonded microparticles. The eluent is a mixture of acetonitrile with 0.025 M sodium phosphate buffer (pH 7). Quantitation is effected by fluorescence detection of the fluorophores formed after post-column derivatization with fluorescamine in a packed-bed reactor. The chromatographic conditions and the conditions for the post-column derivatization are discussed. The method has been applied to serum and urine samples, which were analysed after deproteinization with trichloroacetic acid and injection of the clear supernatant. The accuracy and reproducibility of the procedure were investigated by the determination of the cefatrizine content in spiked serum and urine samples.  相似文献   

19.
A method to determine the content of free pantothenic acid in various foods by reverse phase liquid chromatography-fluorimetry is reported. It includes a purification of the samples by successive passages through anion and cation exchange cartridges and a post-column derivatization of pantothenic acid as the fluorescent 1-alkylthio-2-alkylisoindole (reaction of beta-alanin, formed by hot alkaline hydrolysis of pantothenic acid, with orthophthaldialdehyde in the presence of 3-mercaptopropionic acid). An enzymatic hydrolysis prior to the purification step (pepsin at 50 degrees C for 3 h, then pantetheinase and alkaline phosphatase at 20 degrees C for 18 h) made it possible to release the bound pantothenic acid and thus to obtain the total Vitamin B5 content of these foodstuffs. The method proposed for the determination of free and bound pantothenic acid gives a good recovery rate (96-101%) and a satisfactory repeatability (R.S.D.r less than 8%). Owing to its low detection limit (0.65 microg g(-1)) and the good resolution of the pantothenic acid peak, it could most probably be applied to the determination of this vitamin in any foodstuff.  相似文献   

20.
A new method for the determination of Ochratoxin A (OTA) in green coffee beans by solid-phase microextraction (SPME) coupled to liquid chromatography with fluorescence detection (LC-FD) is described for the first time. Coffee samples were extracted by a 5% NaHCO(3) solution, followed by a clean-up step of the extract by chloroform partition. The aqueous extract was then acidified and finally subjected to SPME-LC-FD analysis. The investigated linear range in coffee was 2-32 ng/g. Within-day RSD% in coffee spiked at 2 and 32 ng/g levels were 3.3 and 2.7, respectively, whereas the between-days RSD% were 4.1 and 3.8, respectively. The limits of detection (LOD) and quantitation (LOQ), calculated at a signal-to-noise ratio of 3 and 10 (noise calculated peak to peak on a blank chromatogram at the OTA retention time), were 0.3 and 2 ng/g, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号