首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
In the framework of developing analyses for exogenous contaminants in food matrices such as honey, we have compared data obtained by high-performance liquid chromatography coupled with mass spectrometry (LC–MS) to those provided by high-performance liquid chromatography and tandem mass spectrometry (LC–MS–MS). Initial results obtained with LC–MS showed that the technique lacked selectivity, which is why the method was validated by LC–MS–MS. This method involves a solid-phase extraction (SPE) of nitrofuran metabolites and nitrofuran parent drugs, a derivatization by 2-nitrobenzaldehyde for 17 h, and finally a clean-up by SPE. The data obtained show that the limits of detection varied between 0.2 and 0.6 μg kg−1 for the metabolites and between 1 and 2 μg kg−1 for nitrofuran parent drugs. The method was applied to different flower honeys. The results showed that nitrofurans (used as antibiotics) are consistently present in this matrix, the predominant compound being furazolidone. Figure Working bees  相似文献   

3.
The presence of a dynamic and balanced equilibrium between the production of reactive oxygen (ROS) and nitrogen (RNS) species and the in-house antioxidant defense mechanisms is characteristic for a healthy body. During oxidative stress (OS), this balance is switched to increased production of ROS and RNS, exceeding the capacity of physiological antioxidant systems. This can cause damage to biological molecules, leading to loss of function and even cell death. Nowadays, there is increasing scientific and clinical interest in OS and the associated parameters to measure the degree of OS in biofluids. An increasing number of reports using LC–MS/MS methods for the analysis of OS biomarkers can be found. Since bioanalysis is usually complicated by matrix effects, various types of cleanup procedures are used to effectively separate the biomarkers from the matrix. This is an essential part of the analysis to prepare a reproducible and homogenous solution suitable for injection onto the column. The present review gives a summary of the chromatographic methods used for the determination of OS biomarkers in both urine and plasma, serum, and whole blood samples. The first part mainly describes the biological background of the different OS biomarkers, while the second part reports examples of chromatographic methods for the analysis of different metabolites connected with OS in biofluids, covering a period from 2015 till early 2020. The selected examples mainly include LC–MS/MS methods for isoprostanes, oxidized proteins, oxidized lipoproteins, and DNA/RNA biomarkers. The last part explains the clinical relevance of this review.  相似文献   

4.
4-Hydroxy isoleucine is one of the potent hypoglycemic active constituents of fenugreek seeds. A method capable of reducing biological interferences is required for bioavailability studies. An isocratic separation of 4-hydroxy isoleucine from endogenous interferences was achieved in ZIC-cHILIC column using 0.1% formic acid in water and acetonitrile (20:80, % v/v) pumped at 0.5 ml/min. Quantification was performed in multiple reaction monitoring mode using the transitions of m/z 148.1→102.1 and m/z 276.1→142.2 for 4-hydroxy isoleucine and homatropine (as internal standard), respectively. After full method validation, 4-hydroxy isoleucine levels in human plasma and commercial fenugreek formulations were determined. This method showed good linearity in the range of 50–2000 ng/mL. Intra- and interday accuracies were in the range of 90.64–109.0% and precision was <4.82% CV. The mean (SD) plasma concentration of 4-hydroxy isoleucine in healthy individuals at 2 h after oral administration of fenugreek tablet was found to be 1590 (260) ng/mL. Half of marketed formulations were found to contain <0.05% of 4-hydroxy isoleucine content. We developed a rapid hydrophilic interaction liquid chromatography–tandem mass spectrometry method for analysis of 4-hydroxy isoleucine in human plasma. This method can be applied directly to conduct the clinical pharmacokinetics studies of 4-hydroxy isoleucine in human population.  相似文献   

5.
Melarsoprol is the only currently available drug for treatment of the late stage of African trypanosomiasis (sleeping sickness). Unfortunately, the arsenic-containing drug causes serious side effects, for which the mechanisms have not been elucidated so far. This investigation describes the study of the melarsoprol biotransformation processes by electrochemical (EC) techniques. Based on EC, potential oxidation reactions of melarsoprol are examined. Moreover, the reactivity of melarsoprol, its metabolite melarsen oxide, and their oxidation products toward the tripeptide glutathione and the proteins hemoglobin and human serum albumin is evaluated. The combination of different analytical techniques allows the identification as well as the quantification of the biotransformation products. The hyphenation of liquid chromatography (LC) and electrospray ionization mass spectrometry (ESI–MS) is applied for identification and structure elucidation, which implies the determination of exact masses and fragmentation patterns. For the selective detection of arsenic containing metabolites, LC coupled to inductively coupled plasma mass spectrometry is utilized. Based on the obtained data, the oxidative biotransformation of melarsoprol can be predicted, revealing novel species which have been suspected, but not been identified up to now. The results of the protein studies prove that melarsen oxide, the active derivative of melarsoprol, strongly binds to human hemoglobin and forms different adducts via the free cysteinyl groups of the hemoglobin α- and β-chain.  相似文献   

6.
Two methods were developed for the quantitative analysis of phenolic acids in herb extracts. The methods were based on liquid chromatography–time-of-flight mass spectrometry (LC–TOFMS) and gas chromatography–mass spectrometry (GC–MS). The methods were compared in terms of their linearity, repeatability, selectivity, sensitivity and the speed of the analysis. The sensitivity was good for both methods, with limits of detection of <80 ng/ml for most of the compounds. The relative standard deviations (RSD) of the peak areas were on average 7.2% for the LC–TOFMS method and 1.4% for the GC–MS method. Both methods were found to be suitable for the determination of the target analytes, although GC–MS was better suited to the quantitative determination of compounds present at low concentrations.  相似文献   

7.
The presence of coccidiostats in meat products represents an important topic because of the animal administration of these substances, authorized as feed additives for targeted species, in order to prevent and inhibit coccidiosis. Coccidiostats include both ionophores and synthetic molecules characterized by different chemical–physical properties such as polarity. Meat is a matrix characterized by many interfering compound groups, such as proteins, phospholipids, and fats. High-performance liquid chromatography (HPLC) coupled to mass spectrometry (MS) analysis allows the required selectivity and sensitivity for discriminating analytes and matrix interferences. For these reasons, an LC–MS/MS method for the analysis of coccidiostats in meat products was developed without SPE purification steps. The correct analyte quantification is allowed by matrix-matched calibration. The method validation was performed by the replicated analysis of spiked meat samples at two different concentration levels (limit of quantification—LOQ—and a 10 times LOQ) in order to evaluate method recovery and repeatability, plus spiked samples at higher concentrations up to 10,000 μg/kg. Moreover, the metrological approach was used for the calculation of method uncertainty. The application of the developed method to real samples evidenced the presence of some non-ionophores coccidiostats in the meat and liver of chicken and rabbit species. Although, the determined concentration was below the established MRLs, the monitoring of coccidiostats in the meat supply chain is confirmed as a good strategy in order to safeguard consumer health.  相似文献   

8.
Acetaldehyde adducts of hemoglobin have been regarded as potential biochemical markers of alcohol exposure. In this study a novel sensitive method using liquid chromatography coupled to time-of-flight mass spectrometry (LC–TOF MS) has been used to investigate changes in adduct levels in alcohol detoxification patients. Hemoglobin and authentic blood samples from 66 adults with an alcohol-dependence syndrome and from 12 children were analyzed for acetaldehyde modifications with and without trypsin digestion using LC–TOF MS. After in-vitro incubation of hemoglobin with increasing concentrations of acetaldehyde, followed by tryptic digestion, 21 modified peptide fragments could be identified from their accurate mass and retention time shift. Eight of these could also be detected in authentic human blood samples. Trace amounts in children’s blood were indicative of an endogenous source. Modified peptide levels in patients’ samples with and without ethanol were significantly different, as also were levels in samples from admission and from five days later. Samples obtained 5, 10, or 15 days after admission did not differ in adduct levels. The LC–TOF MS method was sensitive enough to detect acetaldehyde-modified hemoglobin peptides in blood samples from patients with an alcohol-dependence syndrome. However, elevated levels were only observed after recent ethanol consumption and decreased during five days of abstinence, suggesting that acetaldehyde-modified tryptic peptides of hemoglobin are potential biomarkers only for short-term ethanol ingestion.  相似文献   

9.
10.
Olive oil polyphenols have important biological properties which closely depend on their bioavailability; it is, therefore, essential to understand how polyphenols are absorbed, metabolized, and eliminated from the body. An analytical method based on rapid-resolution liquid chromatography (RRLC) coupled with mass spectrometric detection with a time-of-flight analyzer (RRLC–ESI-TOF MS) has been developed for analysis of the main olive oil phenolic compounds and their metabolites in human urine. Urine samples from ten healthy volunteers were collected before and 2, 4, and 6 h after intake of 50 mL extra-virgin olive oil. The proposed method includes liquid–liquid extraction with ethyl acetate, which provides extraction recoveries of the phenolic compounds studied between 35 and 75% from spiked urine samples. Good repeatability was obtained—the relative standard deviations (RSDs) of peak areas in intra-day and inter-day studies were 4.3 and 6.5%, respectively. Statistical studies enabled us to discriminate between urine samples before and after intake, and facilitated the search for m/z values enabling this discrimination. Based on the very accurate mass information and the isotopic pattern provided by the TOF MS analyzer, together with other available information, ten of these biomarkers and more than 50 metabolites, obtained through phase I and phase II biotransformation reactions, were tentatively identified. Additionally, kinetic studies were conducted on the metabolites identified as possible biomarkers; for most of the compounds concentrations were maximum in the first two hours.  相似文献   

11.
The surface heterogeneity of calcite and apatite was investigated by high resolution adsorption isotherms of argon and nitrogen. The use of the derivative isotherm summation procedure reveals the presence of high energy adsorption sites for nitrogen molecules. These sites are assigned to surface calciums and monohydrogenophosphate groups for calcite and apatite respectively. The comparison of gas adsorption results with experiments at solid–liquid interfaces shows that nitrogen probes the same surface sites as benzoic acid on calcite and decylammonium chloride on apatite.  相似文献   

12.
A sensitive LC–MS–MS method with electrospray ionization has been developed for determination of nikethamide in human plasma. After addition of atropine as internal standard, liquid–liquid extraction was used to produce a protein-free extract. Chromatographic separation was achieved on a 150 mm × 2.1 mm, 5 μm particle, Agilent Zorbax SB-C18 column, with 45:55 (v/v) methanol–water containing 0.1% formic acid as mobile phase. LC–MS–MS was performed in multiple reaction monitoring mode using target fragment ions m/z 178.8 → 107.8 for nikethamide and m/z 289.9 → 123.8 for the internal standard. Calibration plots were linear over the range of 20.0–2,000 ng mL?1. The lower limit of quantification was 20.0 ng mL?1. Intra-day and inter-day precisions were better than 4.2 and 6.1%, respectively. Mean recovery of nikethamide from human plasma was in the range 65.3–71.1%.  相似文献   

13.
A sensitive and selective liquid chromatography–tandem mass spectrometry method for the determination of memantine was developed and validated over the linearity range 0.1–25 ng mL?1 with 0.5 mL of plasma using procainamide as the internal standard. This analysis was carried out on a Cosmosil 5C18-MS column and the mobile phase was composed of methanol: 0.5% formic acid (50:50, v/v). Detection was performed on a triple–quadrupole tandem mass spectrometer using positive ion mode electrospray ionization and quantification was performed by multiple reaction monitoring mode. The MS–MS ion transitions monitored were m/z 180 → 107 and 236 → 163 for memantine and procainamide, respectively. The between- and within-day precision was less than 10.9% and accuracy was less than 2.5%. The lower limit of quantification (LLOQ) was 0.1 ng mL?1. The method proved to be accurate and specific, and was applied to the pharmacokinetic study of memantine in healthy Chinese volunteers.  相似文献   

14.
In antibody-based drug research, a complete characterization of antibody proteoforms covering both the amino acid sequence and all posttranslational modifications remains a major concern. The usual mass spectrometry-based approach to achieve this goal is bottom-up proteomics, which relies on the digestion of antibodies but does not allow the diversity of proteoforms to be assessed. Middle-down and top-down approaches have recently emerged as attractive alternatives but are not yet mastered and thus used in routine by many analytical chemistry laboratories. The work described here aims at providing guidelines to achieve the best sequence coverage for the fragmentation of intact light and heavy chains generated from a simple reduction of intact antibodies using Orbitrap mass spectrometry. Three parameters were found crucial to this aim: the use of an electron-based activation technique, the multiplex selection of precursor ions of different charge states, and the combination of replicates.  相似文献   

15.
A rapid and efficient analysis and screening method is adopted for cell affinity capture coupled with HPLC–MS (CAC–HPLC–MS) analysis of bioactive components that have possible efficiency against cardiovascular diseases. This method involves affinity capture, concentration, and separation of bioactive components from Danshen library using oxidatively damaged endothelial cells induced by H2O2, as well as analysis and identification of targeted compounds with HPLC and MS. It combines the specific interaction between cell membrane receptors and bioactive components with the powerful analysis and identification function of HPLC–MS. The CAC–HPLC–MS method was also used for analysis and screening of bioactive components from crude extracts of Danshen. A total of 19 components were found to be bound to oxidatively damaged endothelial cells with seven of these identified. Existing literature confirms that these seven components have many activities related to cardioprotective diseases. Therefore, the combination of biological affinity capture with HPLC–MS should be regarded as an attractive method with great potential for rapid and efficient screening of bioactive components related to anti-cardiovascular diseases from natural product libraries.  相似文献   

16.
A sensitive method for quantification of citric, fumaric, malic, malonic, oxalic, trans aconitic, and succinic acid in soil- and root-related samples is presented. The method is based on a novel, fast, and simple esterification procedure and subsequent analysis via liquid chromatography–mass spectrometry. Derivatization comprises in situ generation of HCl, which catalyzes the Fischer esterification with benzyl alcohol. As a key advance, the esterification with the aromate allows reversed-phase separation and improves electrospray ionization efficiency. The method provided procedural detection limits of 1 nM for citric, 47 nM for fumaric, 10 nM for malic, 10 nM for malonic, 16 nM for oxalic, 15 nM for succinic, and 2 nM for aconitic acid utilizing 500 μL of liquid sample. The working range was 3 nM to 10 μM for citric acid, 158 nM to 10 μM for fumaric acid, 34 nM to 10 μM for malic acid, 33 nM to 10 μM for malonic acid, 53 nM to 10 μM for oxalic acid, 48 nM to 10 μM for succinic acid, and 6 nM to 10 μM for aconitic acid. Quantification of the analytes in soil-related samples was performed via external calibration of the entire procedure utilizing 13C-labeled oxalic and citric acid as internal standards. The robustness of the method was tested with soil extracts and samples from hydroponic experiments. The latter concerned the regulation of phosphorus solubilization via plant root exudation of citric, malic, and oxalic acid.  相似文献   

17.
Erianin is one of the bibenzyl ingredients isolated from Dctidrobium chrysotoxum Lindl. In recent years, erianin has attracted attention owing to its antitumor activity. In this study, an LC–MS/MS method was established to measure erianin in rat plasma. Gigantol was used as the internal standard. A Waters Acquity UPLC BEH C18 column was employed for chromatographic separation. The mobile phase consisted of water containing 0.1% formic acid and acetonitrile with a gradient elution at the flow rate of 0.4 ml/min. Selective reaction monitoring mode was used for quantitative analysis of erianin in positive electrospray ionization. In the concentration range of 0.1–1200 ng/ml, erianin in rat plasma was linear with correlation coefficient >0.999. The lowest limit of quantification was 0.1 ng/ml. The intra- and inter-day RSDs were <9.69%, while the RE was in the range of −8.59–11.24%. The mean recovery was >85.37%. Erianin was stable in rat plasma after storage under certain conditions. The validated method was demonstrated to be selective, sensitive and reliable, and has been successfully applied to pharmacokinetic study of erianin in rat plasma. Erianin was rapidly eliminated from rat plasma with a short half-life (〜1.5 h) and low oral bioavailability (8.7%).  相似文献   

18.
Xin Hu  Yun-Feng Lv  Kai-Shun Bi 《Chromatographia》2009,69(9-10):1073-1076
A rapid and simple high-performance liquid chromatographic tandem mass spectrometric method has been developed and validated for analysis of strictosamide in rat plasma. Chromatographic separation was achieved on a C18 column by gradient elution with mixtures of methanol, water, and acetonitrile containing 0.05% acetic acid. Digoxin was used as internal standard. Selected reaction monitoring (SRM) was used for MS quantitation. Linearity was good in the range 0.05–20 ng mL?1 in rat plasma. The lower limit of quantitation was 0.04 ng mL?1. The method is precise and reliable and can be applied to pharmacokinetic studies.  相似文献   

19.
Determination of ten sulfonamides (SAs) in egg and honey has been compared using column liquid chromatography (LC) and ultra-performance liquid chromatography (UPLC) coupled to tandem mass spectrometry (MS–MS). A liquid–liquid extraction with acetonitrile followed by solid-phase extraction on a Strata-X cartridge was developed for sample preparation. The analytical performance of both methods was compared applying the alternative matrix-comprehensive in-house validation approach using specially designed software InterVal?. Using UPLC the separation time was shortened about 30% reducing the run time by 8 min and a better resolution was achieved compared to LC. Due to higher peak efficiency achieved with UPLC, the decision limit values obtained by both techniques were almost equal (6.61–9.43 μg kg?1 and 7.25–11.9 μg kg?1 for UPLC and LC, respectively), despite the fact that in UPLC twice lower sample volumes were injected. Satisfactory and comparable recoveries (80–110%) were obtained by UPLC and LC for all the SAs, except for sulfacetamide by LC and sulfabenzamide by both methods. For a majority of the spiked compounds, UPLC gave significantly better precision.  相似文献   

20.
A simple and rapid LC–MS–MS assay was developed and validated for the quantitative determination of pitavastatin in human plasma. Sample pretreatment involved simple protein precipitation by addition of acetonitrile. Separation was on an Agilent 1.8 μm Zorbax SB-C18 column (150 mm × 4.6 mm) at 25 °C using isocratic elution with methanol–0.1% formic acid in water (85:15, v/v) at a flow rate of 0.4 mL min?1. Detection was performed using electrospray ionization in positive ion multiple reaction monitoring mode by monitoring the ion transitions m/z 422.0 → 290.1 for pitavastatin, and m/z 330.1 → 192.1 for paroxetine (IS). LC–MS–MS was found to improve the quantitation of pitavastatin in plasma and was successfully applied in pharmacokinetic studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号