共查询到20条相似文献,搜索用时 140 毫秒
1.
2.
建立了饲料和卧床土中雌三醇、雌二醇、雌酮、双酚A和己烯雌酚5种环境雌激素的固相萃取结合高效液相色谱-串联质谱(HPLC-MS/MS)测定方法。对色谱流动相、质谱条件、固相萃取柱等影响因素进行了优化,得到的最优化条件为:样品经乙腈提取后,用固相萃取柱(NH2-SPE)进行富集,采用Acquity UPLCTM HSS T3色谱柱分离,以乙腈-甲醇(4:1, v/v)与0.01%氨水为流动相,采用梯度洗脱,在负离子模式下进行MS/MS测定。在该优化条件下,5种环境雌激素的检出限(以信噪比为3计)为0.06~0.22 μg/kg,回收率为81.70%~102.20%,相对标准偏差小于10.00%。该方法用于饲料和卧床土中的5种环境雌激素残留量的测定具有简便、快速、灵敏的特点。 相似文献
3.
建立了化妆品中四环素、土霉素、金霉素、强力霉素、甲烯土霉素、去甲基金霉素、二甲胺四环素、脱水四环素和差相四环素含量的液相色谱串联质谱测定方法.对提取溶剂、流动相、流动相的梯度以及质谱参数进行了研究.采用乙腈-甲醇-草酸水溶液提取,LC-MS/MS分离测定,样品中被测物与干扰物能得到良好的分离.甲烯土霉素、去甲基金霉素在0.05 ~10.0 mg/L 范围内其质量浓度与峰面积均呈良好的线性关系,其余7种化合物在0.01 ~10.0 mg/L范围内其质量浓度与峰面积呈良好的线性关系.添加1.0 ~50.0 mg/kg时的加标回收率为73% ~99%,相对标准偏差低于13.2%.该法简便、快速、准确,可用于化妆品中上述9种四环素类药物的定性、定量检测. 相似文献
4.
5.
6.
建立了一种超高效液相色谱-串联质谱(UPLC-MS/MS)同时测定灰尘中26种双酚类化合物(BPs)的多残留分析方法。实验通过优化26种BPs的色谱-质谱参数,比较了不同色谱柱和流动相的分离效果,同时考察了提取溶剂、固相萃取(SPE)等前处理条件对目标化合物的提取效率和净化效果的影响,再结合同位素内标法进行定量,实现了对灰尘中26种BPs的定量分析。灰尘样品依次用3 mL乙腈和3 mL 50%甲醇水溶液进行超声萃取,合并两次提取液,用6 mL超纯水稀释后通过Oasis HLB(60 mg/3 mL)固相萃取小柱,0.5 mL 40%甲醇水溶液淋洗,2 mL甲醇洗脱。以甲醇-1 mmol/L氟化铵水溶液为流动相,流速为0.3 mL/min,经CORTECS? UPLC? C18色谱柱(100 mm×2.1 mm, 1.6μm)分离后,在电喷雾正、负离子多反应监测(MRM)模式下检测26种BPs。26种目标物在各自的范围内线性关系良好,相关系数(r2)>0.999,方法的检出限(LOD)为0.01... 相似文献
7.
建立了水果、蔬菜、粮谷、油料、动植物脂类、动物源性食品等6类食品中增效醚残留量快速测定的液相色谱-质谱/质谱(LC-MS/MS)方法。样品盐析并除水后,用三氯甲烷提取,氟罗里硅土填料固相萃取柱净化,丙酮-三氯甲烷混合溶剂洗脱,以乙腈-0.1%甲酸为流动相,在Zobax SB C18液相色谱柱完成分离,并于电喷雾正离子多反应监测模式下质谱测定。考察了提取溶剂、净化方法、柱容量、仪器条件、基质效应对分析结果的影响。增效醚质量浓度在0.5~100μg/L范围内,线性相关系数(r)为0.9976,方法定量限(LOQ)为10μg/kg。17种食品基质添加LOQ、低MRL、2倍MRL、高MRL 4个不同浓度水平时,回收率在80.3%~96.3%之间,相对标准偏差为2.7%~14%,方法可以满足多种食品基质中增效醚残留量的定性和定量检测要求。 相似文献
8.
9.
10.
11.
12.
建立了丹磺酰氯(DNS)柱前衍生-液相色谱-串联质谱(LC-MS/MS)测定葡萄和樱桃中单氰胺的方法。样品经破壁机匀浆,乙酸乙酯超声提取,无水硫酸钠除水,提取液经减压浓缩,在碱性条件下与丹磺酰氯进行衍生反应。色谱柱为岛津Shim-pack XR-ODS色谱柱(75 mm×2.0 mm,1.6 μm),流动相为甲醇和含0.05%(体积分数)甲酸的2 mmol/L醋酸铵水溶液,梯度洗脱,采用电喷雾离子源正离子多反应监测模式进行质谱检测。单氰胺在0.01~1.0 mg/L范围内,峰面积与质量浓度之间线性关系良好,相关系数不小于0.9990。在0.01、0.05和1.0 mg/kg的添加水平下,葡萄和樱桃中单氰胺的平均回收率为75%~81%,精密度为6.5%~9.8%,定量限为0.01 mg/kg。该方法简便、快速、可靠,可用于批量检测葡萄和樱桃中单氰胺残留。 相似文献
13.
糖链结构的质谱解析是今后糖蛋白分析中的重要研究内容,其中完整糖肽的分析,由于可以同时获得糖基化位点和对应糖链的结构信息,更具有重要意义和研究前景。本工作对质谱软电离技术在完整糖肽分析中的应用进行了研究,其中包括了基质辅助激光解吸电离(matrix-assisted laser desorption ionization, MALDI)和电喷雾电离(electrospray ionization, ESI)技术。通过平行使用两种串联质谱(tandem mass spectrometry, MS/MS)分析策略: MALDI-MS/MS和ESI-MS/MS对目标糖蛋白——辣根过氧化物酶进行分析,并讨论了其互补性。结果表明,MALDI和ESI技术各有优劣,结合串联质谱分析,可获得糖肽的糖链结构信息;两条路线互补使用,在揭示蛋白质糖基化修饰(位点和结构)的研究中十分必要。 相似文献
14.
通过比较不同吸附剂的净化效果,建立了油茶籽中18种多氯联苯(PCBs)的气相色谱-三重四极杆质谱(GCQQQ-MS/MS)检测方法。油茶籽样品用乙腈提取,加氯化钠盐析,离心分层后提取液加无水硫酸镁、C18、N-丙基二乙胺(PSA)和多壁碳纳米管(NANO)进行多管漩涡振荡分散固相净化,GC-QQQ-MS/MS多反应监测(MRM)模式进行检测。结果表明,油茶籽中18种多氯联苯具有良好的线性关系,检出限为5μg/kg,平均回收率为109.2%,相对标准偏差为2.9%~6.2%(n=3)。方法应用于3个油茶主产省份油茶籽监测,48个油茶籽样品中18种多氯联苯均未检出。 相似文献
15.
L-羟脯氨酸寡肽混合物的高效液相色谱分离与质谱分析 总被引:3,自引:0,他引:3
研究了三氯氧磷辅助下L-羟脯氨酸的成肽反应,建立了采用反相高效液相色谱-质谱/质谱联用技术分离鉴定羟脯氨酸寡肽混合物的方法,优化了L-羟脯氨酸寡肽混合物的色谱分离条件。实验以YWG C8柱(10 μm,250 mm×10 mm)为分离柱,以乙腈-0.06%三氟乙酸水溶液(体积比为2∶98)为流动相进行等度洗脱,在正离子模式下对洗脱物进行了电喷雾电离串联质谱鉴定。结果显示,分离出的各组分分别为L-羟脯氨酸二肽、L-羟脯氨酸环二肽和L-羟脯氨酸三肽。 相似文献
16.
采用了一种高效基质脂肪吸附剂(EMR-Lipid)去除水产品基质中的脂肪和磷脂等杂质,利用超高效液相色谱-四极杆/静电场轨道阱高分辨质谱法(UPLC-Q Orbitrap HRMS)的同时定性定量功能,建立了水产品中25种药物残留的检测方法。样品经乙腈提取,EMR-Lipid净化,同时加入3 g氯化钠和3 g无水硫酸钠进行盐析,采用ACQUITY UPLC BEH C18色谱柱(100 mm×2.1 mm,1.7 μm)分离,以含0.1%(v/v)甲酸的乙腈溶液和0.1%(v/v)甲酸水溶液为流动相进行梯度洗脱,在加热电喷雾离子(HESI)源、全扫描/实时二级质谱扫描(Full MS/dd-MS2)监测模式下进行检测。结果表明,25种目标化合物的质量浓度与母离子峰面积间的线性关系良好,相关系数(r)均大于0.997;25种目标化合物的检出限为0.1~1.0 μg/kg,其平均加标回收率为70.1%~108.9%,相对标准偏差为2.1%~13.8%。该法具有操作简单快捷、灵敏度高等优点。 相似文献
17.
建立了固相萃取-超高效液相色谱-串联质谱测定乳粉和果冻中氯化胆碱的分析方法。样品在10 mL 0.02mol/L乙酸铵溶液(冰乙酸调节pH至3.0)中水解3 h后离心,上清液经DIKMA ProElut PLS固相萃取柱(60 mg/3 mL)净化后,用Agilent ZORBAX 300 SCX色谱柱(150 mm×2.1 mm,5μm)进行分离,通过电喷雾正离子(ESI~+)模式电离,多反应监测(MRM)模式进行定性和定量分析。方法的检出限(LOD,S/N=3)和定量限(LOQ,S/N=10)分别为0.15 mg/kg和0.50 mg/kg,加标回收率为70.8%~100.2%,相对标准偏差(RSD)均不大于6.83%(n=6)。目标化合物在0.05~8.0 mg/L范围内线性关系良好,线性方程为Y=2.05×10~5X+3.24×10~4,相关系数(r)为0.996。对市售乳粉和果冻中的氯化胆碱进行检测,结果表明,乳粉和果冻中氯化胆碱的含量分别为251.0~2 448 mg/kg和0.261~0.314 mg/kg。该法准确可靠、灵敏度高,适用于乳粉和果冻中氯化胆碱的测定。 相似文献
18.
Jan Kratzer Zoltán Mester Ralph E. Sturgeon 《Spectrochimica Acta Part B: Atomic Spectroscopy》2011,66(8):594-603
Three plasma-based ambient pressure ion sources were investigated; laboratory constructed dielectric barrier and rf glow discharges, as well as a commercial corona discharge (DART source). All were used to desorb and ionize a model analyte, providing sampling techniques for ambient mass spectrometry (MS). Experimental parameters were optimized to achive highest signal for acetaminophen as the analyte. Insight into the mechanisms of analyte desorption and ionization was obtained by means of emission spectrometry and ion current measurements. Desorption and ionization mechanisms for this analyte appear to be identical for all three plasma sources. Emission spectra differ only in the intensities of various lines and bands. Desorption of solid analyte requires transfer of thermal energy from the plasma source to sample surface, in the absence of which complete loss of MS response occurs. For acetaminophen, helium was the best plasma gas, providing 100- to 1000-fold higher analyte response than with argon or nitrogen. The same trend was also evident with background ions (protonated water clusters). MS analyte signal intensity correlates with the ion density (expressed as ion current) in the plasma plume and with emission intensity from excited state species in the plasma. These observations support an ionization process which occurs via proton transfer from protonated water clusters to analyte molecules. 相似文献
19.
建立了微波辅助萃取结合气相色谱-飞行时间质谱(GC-TOF MS)技术在负化学电离(NCI)源和电子轰击电离(EI)源两种模式下测定烟草中24种农药残留的分析方法。烟叶样品于100℃下用二氯甲烷-正己烷(3:1, v/v)混合溶剂微波萃取10 min,萃取液经弗罗里硅土固相萃取柱净化后进行检测分析。在NCI源和EI源质谱模式下,24种农药的线性关系均良好(r2>0.99),相对标准偏差分别小于8.6%和9.1%,定量限分别为0.3~6.9 μg/kg和10.2~44.9 μg/kg,加标回收率分别为75.2%~94.8%和75.0%~95.1%。比较两种离子源模式下的色谱图和质谱图,NCI源模式较EI源模式的选择性好、灵敏度高、基质干扰小、图谱简单易于解析,检出限低一个数量级以上,在分析低含量、复杂基质的样品时更具优势。 相似文献
20.
Mass spectrometric behavior of anabolic androgenic steroids using gas chromatography coupled to atmospheric pressure chemical ionization source. Part I: Ionization
下载免费PDF全文
![点击此处可从《Journal of mass spectrometry : JMS》网站下载免费的PDF全文](/ch/ext_images/free.gif)
M. Raro T. Portolés J. V. Sancho E. Pitarch F. Hernández J. Marcos R. Ventura C. Gómez J. Segura O. J. Pozo 《Journal of mass spectrometry : JMS》2014,49(6):509-521
The detection of anabolic androgenic steroids (AAS) is one of the most important topics in doping control analysis. Gas chromatography coupled to (tandem) mass spectrometry (GC–MS(/MS)) with electron ionization and liquid chromatography coupled to tandem mass spectrometry have been traditionally applied for this purpose. However, both approaches still have important limitations, and, therefore, detection of all AAS is currently afforded by the combination of these strategies. Alternative ionization techniques can minimize these drawbacks and help in the implementation of a single method for the detection of AAS. In the present work, a new atmospheric pressure chemical ionization (APCI) source commercialized for gas chromatography coupled to a quadrupole time‐of‐flight analyzer has been tested to evaluate the ionization of 60 model AAS. Underivatized and trimethylsylil (TMS)‐derivatized compounds have been investigated. The use of GC–APCI–MS allowed for the ionization of all AAS assayed irrespective of their structure. The presence of water in the source as modifier promoted the formation of protonated molecules ([M+H]+), becoming the base peak of the spectrum for the majority of studied compounds. Under these conditions, [M+H]+, [M+H‐H2O]+ and [M+H‐2·H2O]+ for underivatized AAS and [M+H]+, [M+H‐TMSOH]+ and [M+H‐2·TMSOH]+ for TMS‐derivatized AAS were observed as main ions in the spectra. The formed ions preserve the intact steroid skeleton, and, therefore, they might be used as specific precursors in MS/MS‐based methods. Additionally, a relationship between the relative abundance of these ions and the AAS structure has been established. This relationship might be useful in the structural elucidation of unknown metabolites. Copyright © 2014 John Wiley & Sons, Ltd. 相似文献