首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Two methods were developed for the quantitative analysis of phenolic acids in herb extracts. The methods were based on liquid chromatography–time-of-flight mass spectrometry (LC–TOFMS) and gas chromatography–mass spectrometry (GC–MS). The methods were compared in terms of their linearity, repeatability, selectivity, sensitivity and the speed of the analysis. The sensitivity was good for both methods, with limits of detection of <80 ng/ml for most of the compounds. The relative standard deviations (RSD) of the peak areas were on average 7.2% for the LC–TOFMS method and 1.4% for the GC–MS method. Both methods were found to be suitable for the determination of the target analytes, although GC–MS was better suited to the quantitative determination of compounds present at low concentrations.  相似文献   

2.
An analytical procedure involving solid-phase extraction (SPE) and gas chromatography–mass spectrometry (GC–MS) has been developed for determination of pharmaceutical compounds (aspirin, caffeine, carbamazepine, diclofenac, ketoprofen, naproxen, ibuprofen, clofibrate, clofibric acid, and gemfibrozil) in a variety of aqueous samples (wastewater and surface water). After filtration, samples were extracted and concentrated using C18 or HLB cartridges, depending on the type of compound. Sample storage conditions were checked and optimized to ensure preservation of the pharmaceutical substance, taking into consideration environmental sampling conditions. For most of the pharmaceuticals monitored, recovery was in the range 53 to 99% and the variability was below 15% for the complete procedure, with limits of detection ranging from 0.4 to 2.5 ng L−1, depending on the compound. The methods were successfully applied to monitoring of pharmaceutical contamination of the Seine estuary. Concentrations varied from several dozens of nanograms per liter for surface waters to several hundreds of nanograms per liter for wastewaters.  相似文献   

3.
4.
The aim of the present study was to develop a novel ultrasound-assisted derivatization method for analysis of urine that can be used for preliminary screening and monitoring of metabolic disorders. Here we describe an ultrasound-assisted derivatization method followed by GC–MS analysis to quantify 26 organic acids in urine. The optimum levels of the variables affecting the yield of derivatization were investigated, including urease doses, derivatization reagents and derivatization conditions (duration time, reaction temperature and sonic power). The method exhibited the best results with 80 μl urease. The optimal reaction conditions were 100 μl BSTFA, 80% ultrasound power, 70°C and 40 min. This method showed satisfactory linearity, good reproducibility and an acceptable limit of detection and accuracy. Therefore, it could potentially be used to as a standard method to enable comparisons between laboratories. Finally, we applied our method to urine samples from pregnant rats administered 2 or 10 mg/kg folic acid supplementation.  相似文献   

5.
6.
Isotope-dilution analysis in combination with GC-ICP-MS detection has been applied to the determination of butyltin species in environmental samples. Different spikes containing the isotopically labeled butyltin species have been synthesized in the laboratory after optimization of the reaction conditions. The isotopic compositions of the tin species in the different spike solutions were determined by GC-ICP-MS after derivatization by aqueous ethylation with sodium tetraethylborate. Reverse isotope-dilution analysis was used for quantitation of the spike solutions by means of natural MBT, DBT, and TBT standards. The mixed spikes were used for simultaneous analysis of MBT, DBT and TBT in the certified reference materials, PACS-2, CRM 462, and CRM 646, with satisfactory results. The excellent agreement of the different speciation results obtained by use of the different spikes is a good indicator of the precision, accuracy, and reliability which can be achieved by using isotope-dilution analysis for trace metal speciation.Application of a double spike containing (119)Sn-enriched MBT (79.7 At%), (118)Sn-enriched DBT (86.7 At%), and (119)Sn-enriched TBT (83.1 At%) also enabled evaluation of the conditions resulting in quantitative extraction of the species from the solid matrix, in combination with possible alterations depending on the different extraction procedures used (mechanical shaking, ultrasounds, and microwaves). Mathematical equations used for this purpose computed the correct species concentrations directly and, additionally, the decomposition factors (from TBT to DBT and from DBT to MBT) after precise measurement of the (119)Sn/(120)Sn and (118)Sn/(120)Sn ratios for all butyltin species by GC-ICP-MS.  相似文献   

7.
8.
9.
10.
This work validated an automated, fast, and low solvent- consuming methodology suited for routine analysis of tributyltin (TBT) and degradation products (dibutyltin, DBT; monobutyltin, MBT) in biota samples. The method was based on the headspace solid-phase microextraction methodology (HS-SPME), coupled with gas chromatographic separation and tandem mass-spectrometry (GC–MS/MS). The effectiveness of the matrix-matched signal ratio external calibration was tested for quantification purposes. The exclusion of matrix influences in the calibration curves proved the suitability of this versatile quantification method. The method detection limits obtained were of 3 ng Sn g−1 dw for all the analytes. The analysis of references materials showed satisfying accuracy under optimum calibration conditions (% recovery between 87–111%; |Z-scores|<2). The repeatability RSD% and intra-laboratory reproducibility RSD% were lower than 9.6% and 12.6%, respectively. The work proved the remarkable analytical performances of the method and its high potential for routine application in monitoring organotin compounds (OTC).  相似文献   

11.
This paper describes methods for the determination of low-molecular-weight (LMW) dicarboxylic acids in atmospheric aerosols as important chemical tracers for source apportionment of aerosol organics and for studying atmospheric processes leading to secondary organic aerosol formation. The two derivatization procedures most widely used in GC analysis of dicarboxylic acids were compared: esterification using BF3/alcohol reagent and silylation using N,O-bis(trimethylsilyl)-trifluoroacetamide (BSTFA). The advantages and drawbacks of the two methods are investigated and compared in terms of (1) precision and accuracy of the results and (2) sensitivity and detection limit of the procedure. The comparative investigation was performed on standard solutions containing target C3–C9 dicarboxylic acids and on experimental particulate matter (PM) samples. Attention was focused on low-volume sampling devices that collect small amounts of sample for organic speciation. The results show that, overall, both the techniques appear suitable for the analysis of LMW dicarboxylic acids in atmospheric aerosols since they provide low detection limits (≤4 ng m−3) and satisfactory reproducibility (RSD% ≤ 15%). Between them, BSTFA should be the reagent of choice under the most limiting conditions of PM filters collected by low-volume air samplers: It provides determination of all the target C3–C9 dicarboxylic acids with lower detection limits (≤2 ng m−3) and higher reproducibility (RSD% ≤ 10%)   相似文献   

12.
Isoprostanoids are a group of non-enzymatic oxygenated metabolites of polyunsaturated fatty acids. It belongs to oxylipins group, which are important lipid mediators in biological processes, such as tissue repair, blood clotting, blood vessel permeability, inflammation and immunity regulation. Recently, isoprostanoids from eicosapentaenoic, docosahexaenoic, adrenic and α-linolenic namely F3-isoprostanes, F4-neuroprostanes, F2-dihomo-isoprostanes and F1-phytoprostanes, respectively have attracted attention because of their putative contribution to health. Since isoprostanoids are derived from different substrate of PUFAs and can have similar or opposing biological consequences, a total isoprostanoids profile is essential to understand the overall effect in the testing model. However, the concentration of most isoprostanoids range from picogram to nanogram, therefore a sensitive method to quantify 20 isoprostanoids simultaneously was formulated and measured by liquid chromatography-tandem mass spectrometry (LC–MS/MS). The lipid portion from various biological samples was extracted prior to LC–MS/MS evaluation. For all the isoprostanoids LOD and LOQ, and the method was validated on plasma samples for matrix effect, yield of extraction and reproducibility were determined. The methodology was further tested for the isoprostanoids profiles in brain and liver of LDLR−/− mice with and without docosahexaenoic acid (DHA) supplementation. Our analysis showed similar levels of total F2-isoprostanes and F4-neuroprostanes in the liver and brain of non-supplemented LDLR−/− mice. The distribution of different F2-isoprostane isomers varied between tissues but not for F4-neuroprostanes which were predominated by the 4(RS)-4-F4t-neuroprostane isomer. DHA supplementation to LDLR−/− mice concomitantly increased total F4-neuroprostanes levels compared to F2-isoprostanes but this effect was more pronounced in the liver than brain.  相似文献   

13.
Sucralose (1,6-dichloro-1,6-dideoxy-β-d-fructofuranosyl-4-chloro-4-deoxy-α-d-galactopyranoside) is a high-intensity non-nutritive sweetener derived from sucrose. Determination of sucralose in food is important to ensure consistent product quality. The authors have developed a new method for determination of sucralose. The sucralose was converted into its trimethylsilyl (TMS) ether and qualitative and quantitative analysis were achieved by GC–MS and GC–FID, respectively, using myo-inositol ester as the internal standard. A good linear relationship between response and amount of sucralose TMS ether was obtained in the range 0.005–0.06 mg mL?1 (r = 0.9994). The detection limit was 0.25 ng.  相似文献   

14.
Methylisothiocyanate (MITC) is the main degradation product of metam sodium, a soil disinfectant widely used in agriculture, and is responsible for its disinfectant properties. Because MITC is highly toxic and volatile, metam sodium has to be applied in a manner that tries to reduce atmospheric emissions but still maintains adequate concentration of MITC in soil to ensure its disinfectant effect. Thus, monitoring of MITC concentrations in soil is required, and to this end sensitive, fast, and reliable analytical methods must be developed. In this work, a headspace solid-phase microextraction (HS-SPME) method was developed for MITC determination in water and soil samples using gas chromatography-tandem mass spectrometry (GC–MS–MS) with a triple-quadrupole analyzer. Two MS–MS transitions were acquired to ensure the reliable quantification and confirmation of the analyte. The method had linear behavior in the range tested (0.026–2.6 ng mL?1 in water, 1–100 ng g?1 in soil) with r 2 over 0.999. Detection limits were 0.017 ng mL?1 and 0.1 ng g?1 in water and soil, respectively. Recoveries for five replicates were in the range 76–92 %, and RSD was below 7 % at the two spiking levels tested for each matrix (0.1 and 1 ng mL?1 for water, 4 and 40 ng g?1 for soil). The potential of using multiple HS-SPME for analyzing soil samples was also investigated, and its feasibility for quantification of MITC evaluated. The developed HS-SPME method was applied to soil samples from experimental plots treated with metam sodium following good agriculture practices. Figure
?  相似文献   

15.
A simple, rapid, sensitive, and non-consuming solvent method for the determination of cotinine in urine was developed, based on sample preparation by the relatively new technique microextraction in packed sorbent (MEPS) and analysis by GC–MS. This optimized method was compared with conventional solid-phase extraction/liquid–liquid extraction method used as reference. The wide linear range (5–5,000 ng/mL) and high sensitivity of the MEPS method (limit of detection 0.8 ng/mL) allow application to analysis of urine from smokers as well as non-smokers susceptible to passive smoking.  相似文献   

16.
Qin-Bao Lin  Hui-Juan Shi  Ping Xue 《Chromatographia》2010,72(11-12):1143-1148
A novel and simple method for determination of 15 organic nitrogen-containing pesticides in vegetables using matrix solid-phase dispersion (MSPD) coupled with gas chromatography tandem mass spectrometry (GC–MS–MS) has been developed. The efficiencies of different sorbents (florisil, silicone, neutral alumina) for the MSPD were compared. Mean recoveries of the method using neutral alumina varied from 73.26 to 111.83% with relative standard deviations of 0.79–15.33% in the concentration range of 0.01, 0.02 and 0.05 mg kg?1. The limits of detection were typically in the 0.0007–0.0320 mg kg?1 range, which were 10–100 times lower than the maximum residue levels established by the European Union. This method was applied to residue detection in vegetables, in which organic nitrogen-containing compounds were detected at low concentrations.  相似文献   

17.
In this paper we report a method based on solid-phase extraction (SPE) and subsequent analysis by gas chromatography combined with mass spectrometry for determination of chloroform in potable water. The affinity of chloroform for the resin enables almost complete recovery of the analyte. The analytical method proposed enables evaluation of chloroform levels down to 0.295 g L–1. The procedure is characterized by lack of interferences, in fact the GC–MS analysis reveals the presence of only one peak, that of chloroform. Use of CDCl3 as labelled internal standard also makes the procedure suitable for use as a reference analytical method for quantification of chloroform in drinking water.  相似文献   

18.
This paper presents the development, optimization and validation of a methodology to determine nine key steroid hormones (viz. pregnenolone, progesterone, dehydroepiandrosterone, androstenedione, testosterone, dihydrotestosterone, estrone, 17α-estradiol and 17β-estradiol) expressed in the steroidogenesis in biological fluids. The analytical method allows for the determination of steroid hormones in blood plasma and serum down to 0.08–0.16 ng/mL for estrogens, 0.20–0.36 ng/mL for androgens and 0.36–0.43 ng/mL for progestagens. These limits of detection were obtainable using a two-step solid-phase clean-up for fractionation and elimination of interfering lipids (fatty acids, phospholipids, glycerides and sterols) from the steroid hormones. The accuracy of the method was 50–112% in the range 0.10 to 2.00 ng/mL.  相似文献   

19.
Static headspace sampling, headspace solid-phase microextraction, and direct immersion solid-phase microextraction coupled with gas chromatography–tandem mass spectrometry have been developed for determination of the volatile components in Radix bupleuri injection. A total of 78 compounds were identified from Radix bupleuri injection. Direct immersion solid-phase microextraction gave a better extraction efficiency for polar compounds, including organic acids and alcohols, than headspace solid-phase microextraction or static headspace sampling. Product ion isotope pattern analysis was applied to determine the elemental composition of the precursor ion, which could make the qualitative analysis more accurate and reliable.  相似文献   

20.
This work presents a sensitive and rapid analytical method for the determination of oxcarbazepine in human plasma and urine samples. A vortex-assisted switchable hydrophilicity solvent-based liquid phase microextraction (VA–SHS–LPME) was used to preconcentrate oxcarbazepine from the samples before the determination by gas chromatography mass spectrometry. The switchable hydrophilicity solvent was synthesized by protonating N,N-dimethylbenzylamine with carbon dioxide to make it totally miscible with an equivalent volume of water. Parameters of the VA–SHS–LPME method including volume of switchable hydrophilicity solvent, concentration/volume of sodium hydroxide and vortex period were systematically optimized. Under the optimum conditions, good linearity ranging from 27.03 to 353.47 μg/kg was obtained for the analyte. Limit of detection and quantitation values were found to be 6.2 and 21 μg/kg (mass base), respectively. The relative standard deviation was calculated as 6.9% for six replicate measurements of the lowest concentration of the calibration plot. Satisfactory recovery results were calculated in the range of 97–100% for human plasma and urine samples spiked at five different concentrations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号